| Plan Review Stops For Permit 08020633 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-15 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-03-21 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-03-12 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-03-12 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2008-03-12 12:14:56 | 2004 FBC W/2007 REVISIONS | | | LEVEL 2 ALTERATIONS | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO (2) COPIES OF OF PRODUCT APPROVALS FOR | | | STORM PANELS FOR THE NEW NON-IMPACT WINDOW. SPECIFY | | | CONNECTION TYPE, FASTENER TYPE AND SPACING, EDGE | | | DISTANCE, ETC. CIRCLE THE APPROPRIATE ITEMS ON THE | | | PRODUCT APPROVAL. FBC R301.2.1.2 | | | | | | 2) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-29 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-03-06 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2008-03-06 15:47:48 | 2004 FBC W/2007 REVISIONS | | | LEVEL 2 ALTERATIONS | | | | | | DENIED BY BUILDING | | | | | | 1)SHOW THAT THE NEW BEDROOM COMPLIES WITH R310.1 | | | EMERGENCY ESCAPE AND RESCUE REQUIRED. | | | BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM | | | SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND | | | RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE | | | SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS | | | SHALL BE REQUIRED IN EACH SLEEPING ROOM, BUT SHALL NOT | | | BE REQUIRED IN ADJOINING AREAS OF THE BASEMENT. WHERE | | | EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY | | | SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES | | | (1118 MM) ABOVE THE FLOOR. WHERE A DOOR OPENING HAVING | | | A THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES | | | AS AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS | | | PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEAD | | | ENCLOSURE SHALL COMPLY WITH SECTION 310.3 . THE NET | | | CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL | | | BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY | | | ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY | | | ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT | | | BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED | | | WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2 . | | | THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE | | | PERMITTED TO OPEN INTO A SCREEN ENCLOSURE, OPEN TO THE | | | ATMOSPHERE, WHERE A SCREEN DOOR IS PROVIDED LEADING | | | AWAY FROM THE RESIDENCE. | | | | | | 2) IF A NEW EXTERIOR WINDOW OR DOOR IS INSTALLED TO | | | COMPLY WITH COMMENT #1, SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS THAT HAVE BEEN REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD FOR THE ITEM AND FOR | | | STORM PANELS IF REQUIRED. FAC RULE 9B-72, FBC 106.3.3* | | | CITY AMENDMENTS AND FBC R301.2.1.2 | | | | | | 3) SPECIFY THE WOOD CONNECTORS THAT WILL BE USED TO | | | ATTACH THE NEW STUDS TO THE EXISTING WOOD BEAM AT THE | | | TOP OF THE NEW WOOD BEARING WALL TO COMPLETE THE | | | CONTINUOUS LOAD PATH REQUIRED BY R301.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-02 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-02 |
Time |
10:27 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-15 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-15 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
| 2008-04-15 14:56:49 | | | | | | | REVISION DENIED/INCOMPLETE INFORMATION | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | 1} THE REVISION SUBMITTED FOR ELECTRICAL REVIEW HAS A | | | RELOCATED WALL, DOOR (EGRESS), SINK, WATER HEATER, | | | RANGE, REFRIGERATOR, WASHER, DRYER AND ELECTRICAL PANEL | | | ALL NOTED AS EXISTING, BUT NOT THE SAME AS THE | | | "EXISTING" CONDITIONS ON THE PERMIT SET.REVISE SHEET | | | A-1 TO INDICATE FIELD CONDITIONS FOR ALL TRADES | | | IMPACTED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-21 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-21 |
Time |
10:39 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-18 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-18 |
Time |
14:02 |
Sent To |
P |
|
| Notes |
| 2008-03-18 14:14:46 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | | FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH | | | THE FOLLOWING: | | | | | | THIS COMMENT WAS FROM THE PREVIOUS TWO REVIEWS, AND NOT | | | ADDRESSED: | | | | | | 2/29/08 REVIEW: 1} THE RISER DIAGRAM ON SHEET A-2 | | | INDICATES "EXISTING", BUT NOTES PERTAINING TO THE RISER | | | INDICATE LOCATION OF THE METER TO BE UNKNOWN. CLARIFY | | | TO INDICATE IF EXISTING OR TO BE INSTALLED, ALSO LOCATE | | | THE SERVICE EQUIPMENT ON THE PLAN. 3/11/08 REVIEW: * | | | THIS COMMENT WAS OVERLOOKED. PLEASE LOCATE ALL SERVICE | | | EQUIPMENT IN THE FLOOR PLAN, A-1..** 3/18/08 REVIEW- | | | THE METER AND DISCONNECT SHOWN ON THE RISER STILL HAVE | | | NOT BEEN LOCATED ON THE PLAN. NOW ON THIS PLAN THE THE | | | PANEL IS SHOWN AS "EXISTING", THE WALL IT'S SHOWN IN IS | | | A NEW WALL, OBVIOUSLY THE PANEL CANNOT BE IN THAT | | | LOCATION. THE PERSON TAKING RESPONSIBILITY FOR THIS | | | PLAN SHOULD VISIT THE SITE TO DETERMINE THESE | | | LOCATIONS. | | | | | | NEW COMMENT : | | | | | | 2} THE LOCATION SHOWN FOR THE PANEL IS IN VIOLATION OF | | | THE CLEARANCE REQUIREMENTS OF 110.26, 2005 NEC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-11 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-11 |
Time |
15:23 |
Sent To |
P |
|
| Notes |
| 2008-03-11 15:56:58 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | | FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH | | | THE FOLLOWING: | | | | | | THIS COMMENT WAS FROM THE PREVIOUS REVIEW, AND NOT | | | ADDRESSED: | | | | | | 1} THE RISER DIAGRAM ON SHEET A-2 INDICATES "EXISTING", | | | BUT NOTES PERTAINING TO THE RISER INDICATE LOCATION OF | | | THE METER TO BE UNKNOWN. CLARIFY TO INDICATE IF | | | EXISTING OR TO BE INSTALLED, ALSO LOCATE THE SERVICE | | | EQUIPMENT ON THE PLAN* THIS COMMENT WAS OVERLOOKED. | | | PLEASE LOCATE ALL SERVICE EQUIPMENT IN THE FLOOR PLAN, | | | A-1.. | | | | | | 2} THE RESUBMITTAL NOW INDICATES A 150 AMP RATED PANEL | | | WITH A 200 AMP MAIN BREAKER. THE RISER. SEE 408.36 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-29 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-29 |
Time |
13:13 |
Sent To |
M |
|
| Notes |
| 2008-02-29 13:53:23 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | | FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH | | | THE FOLLOWING: | | | | | | 1} THE RISER DIAGRAM ON SHEET A-2 INDICATES "EXISTING", | | | BUT NOTES PERTAINING TO THE RISER INDICATE LOCATION OF | | | THE METER TO BE UNKNOWN. CLARIFY TO INDICATE IF | | | EXISTING OR TO BE INSTALLED, ALSO LOCATE THE SERVICE | | | EQUIPMENT ON THE PLAN. | | | | | | 2} THE EQUIPMENT GROUND BETWEEN THE METER AND | | | DISCONNECT ON THE RISER DIAGRAM CREATES A PARALLEL PATH | | | TO GROUND WITH THE NEUTRAL AND MUST BE REMOVED. AN | | | ISOLATED NEUTRAL AND EQUIPMENT GROUND ARE TO BE RAN | | | FROM THE FIRST MEANS OF DISCONNECT. 250.6. IF IT IS | | | DETERMINED TO BE AN EXISTING SERVICE THIS ISSUE MUST BE | | | CORRECTED AS IT IS A LIFE SAFETY ISSUE. | | | | | | 3}RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) | | | AND 210.52(A)(2). 2005 NEC. SEE REVIEWED PLAN FOR | | | DEFICIENCIES IN THE NEW BEDROOM AND KITCHEN. | | | | | | 4} A RECEPTACLE IS REQUIRED IN THE HALL/ENTRY PER | | | 210.52(H). | | | | | | 5}210.52(E) OUTDOOR OUTLETS FOR A ONE-FAMILY DWELLING | | | AND EACH UNIT OF A TWO-FAMILY DWELLING THAT IS AT GRADE | | | LEVEL, AT LEAST ONE RECEPTACLE OUTLET ACCESSIBLE AT | | | GRADE LEVEL AND NOT MORE THAN 2.0 M (6 1/ 2 FT) ABOVE | | | GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF THE | | | DWELLING. | | | | | | FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN THE | | | FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE INDICATE | | | THE CODE CYCLES UNDER WHICH THIS PLAN WAS DESIGNED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-02 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-02 |
Time |
09:47 |
Sent To |
E |
|
| Notes |
| 2008-05-02 09:48:29 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-14 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-14 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2008-03-14 08:51:27 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-07 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-07 |
Time |
16:30 |
Sent To |
Z |
|
| Notes |
| 2008-03-07 16:30:33 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-03-06 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-02-26 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2008-02-26 16:38:13 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-03 |
Time |
11:55 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2008-03-03 |
Time |
11:55 |
Sent To |
P |
|
| Notes |
| 2008-03-03 11:55:48 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-20 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-20 |
Time |
08:12 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-12 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-12 |
Time |
09:15 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-04 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-04 |
Time |
08:19 |
Sent To |
B |
|
| Notes |
| 2008-03-04 08:43:01 | DENIED; | | | AUTOMATIC CLOTHES WASHER CANNOT BE DELETED. SEE FBC | | | PLUMBING TABLE 403.1(R3) MINIMUM PLUMBING FIXTURES | | | REQUIRES A WASHING MACHINE HOOK UP. ALSO SEE SECTION | | | 406.3 THE BRANCH DRAIN SHALL BE 3". | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-18 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-18 |
Time |
10:31 |
Sent To |
E |
|
| Notes |
| 2008-03-18 10:32:17 | ***APPROVED - RESUB #2 (RESTAMPED PLANS)*** | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-10 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-10 |
Time |
15:50 |
Sent To |
E |
|
| Notes |
| 2008-03-10 15:50:57 | ***APPROVED - RESUB #1 (RESTAMPED PLANS)*** | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-27 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-27 |
Time |
14:31 |
Sent To |
E |
|
| Notes |
| 2008-02-27 14:34:11 | ***APPROVED*** |
|
|