| Plan Review Stops For Permit 08020593 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-05-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-03 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-03 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-09 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-09 |
Time |
07:14 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-05 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-03-05 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2008-03-05 17:41:37 | BUILDING PLAN REVIEW | | | PERMIT: 08020593 | | | ADD: 580 VILLAGE BLVD. #304 | | | CONT: BIEBER CONST. | | | TEL: (561)276-9966 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3-5-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)F.S 481.221 ALL FINAL CONSTRUCTION DOCUMENTS AND | | | INSTRUMENTS OF SERVICE WHICH INCLUDE DRAWINGS, PLANS, | | | SPECIFICATIONS, OR REPORTS PREPARED OR ISSUED BY THE | | | REGISTERED ARCHITECT AND BEING FILED FOR PUBLIC RECORD | | | SHALL BEAR THE SIGNATURE AND SEAL OF THE REGISTERED | | | ARCHITECT WHO PREPARED OR APPROVED THE DOCUMENT AND THE | | | DATE ON WHICH THEY WERE SEALED. THE SIGNATURE, DATE, | | | AND SEAL SHALL BE EVIDENCE OF THE AUTHENTICITY OF THAT | | | TO WHICH THEY ARE AFFIXED. THE DATE IS MISSING ON THE | | | SEAL. THE CERTIFICATE OF AUTHORIZATION FOR THE | | | DIFFERENT ENGINEERING AND ARCHITECTURAL FIRMS INDICATED | | | ON THE PLANS IS REQUIRED TO BE SHOWN ON THE PLANS. | | | 61G1-16.004 TITLE BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | | | | 3)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 4)WHAT IS THE OCCUPANT LOAD OF THE SPACE? INDICATE | | | THE SQUARE FOOTAGE OF THE NEW SPACE AND GIVE THE | | | OCCUPANT LOAD USING TABLE 1004.1.2. | | | | | | 5)FBC 11-7.2(2) (I) A PORTION OF THE RECEPTIONIST | | | WINDOW SHALL BE A MINIMUM LENGTH OF 36 INCHES AND A | | | MAXIMUM HEIGHT OF 36 INCHES. DETAILS #2 AND #4 ON SHEET | | | A7.0 SHOW A HEIGHT OF 3'6" AT THE RECEPTIONIST WINDOW. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | FAX (561)805-6676 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-22 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-22 |
Time |
09:12 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-08 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-08 |
Time |
06:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-29 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-28 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2008-02-29 15:52:30 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} INDICATE WHAT THE PRIMARY OCP IS FOR TRANSFORMER | | | "TLM". IF THE 60 AMP RATED DISCONNECT HAS IN FACT A 60 | | | AMP OCP INSTALLED, IT WOULD NOT COMPLY WITH 450.3(B). | | | 125% OF A 30000 WATT TRANSFORMER WOULD ALLOW A 50 AMP | | | OCP MAXIMUM. | | | | | | 2} THERE IS NO SECONDARY OCP FOR "TLM" AS PANEL "LM" IS | | | LISTED AS MAIN LUG ONLY. SEE 408.36 AND 450.3(B). | | | | | | 3} THE LIGHTING CIRCUITS ARE NOT ON THE PANEL SCHEDULE | | | AND DO NOT APPEAR TO BE CALCULATED AT 125% (CONTINUOUS | | | LOAD) PER 215.2. | | | | | | 4} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK | | | MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 | | | FAC. THE DATE IS MISSING. | | | | | | 5} THE ENGINEERING FIRM LISTED ON THE TITLE BLOCK SHALL | | | INDICATE THE CERTIFICATE OF AUTHORIZATIONNUMBER PER | | | 61G15-23.002FLORIDA ADMINISTRATIVE CODE.. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-05-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-06 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-05-06 |
Time |
11:39 |
Sent To |
B1 |
|
| Notes |
| 2008-05-06 11:55:59 | *****APPROVED***** | | | | | | PLAN SHEETS AN-3, A1.0, A5.0, AND E2 WERE PREVIOUSLY | | | FIRE-STAMPED ON 4/08/2008;NEW SHEET A1.0 WAS STAMPED, | | | INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-08 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-08 |
Time |
15:30 |
Sent To |
B1 |
|
| Notes |
| 2008-04-08 16:09:32 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEETS AN-3, A1.0, A5.0, AND E2 | | | WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-10 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-10 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2008-03-10 16:10:44 | *****DENIED***** | | | | | | 1.THE SCOPE OF WORK SHALL NOT INTERFERE OR HINDER | | | ACCESS TO AND/OR EGRESS FROM OTHER TENANT SPACES ON THE | | | FLOOR OR THE BUILDING. | | | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 3.PLEASE INDICATE IF THE BUILDING IS TO BE OCCUPIED | | | DURING THE SCOPE OF WORK.IF SO, MEANS OF EGRESS AND | | | AND REQUIRED FIRE PROTECTION FEATURES ARE TO BE IN | | | PLACE AND CONTINUOUSLY MAINTAINED. | | | | | | 4.PLEASE LIST THE OCCUPANT LOAD FOR THIS NEW TENANT | | | SPACE. | | | | | | 5.SHOW THE LOCATION OF THE 2A10:BC FIRE | | | EXTINGUISHER(S) WHICH SATISFIES THE 75' TRAVEL | | | DISTANCE. | | | | | | 6.SHOW A LAYOUT OF THE FIRE SPRINKLER HEADS FOR THIS | | | SCOPE OF WORK.IF THE ALTERATION HAS CAUSE FOR THE | | | SPRINKLER SYSTEM BE REMODELED, SEPARATE PLANS AND | | | PERMIT WILL BE REQUIRED ONCE THE MASTER PERMIT HAS BEEN | | | ISSUED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER, INDICATING WHERE (ON THE PLAN) EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-16 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-16 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2008-05-16 15:38:53 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-22 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-22 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2008-04-22 10:37:46 | TO "BOB"#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-31 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-31 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2008-03-31 09:15:08 | TO "BOB"#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-10 |
Time |
15:16 |
Rev Time |
|
| Received By |
mawillia |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-21 |
Time |
08:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-05-21 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2008-05-21 08:44:54 | *** PROVISO *** | | | 1) HAVE PRODUCT APPROVAL OR AN NOA FOR PER-ENGINEERED | | | CONDENSER STANDS ON JOB SITE FOR CITY INSPECTOR, PER FS | | | 553.842(1) AND FAC RULE 9B-72, 9B-72.005, AND FAC | | | 9B-72.010(31)(G). | | | | | | ** PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW STAMP AND | | | SIGNATURE WILL MEET THIS REQUIREMENT). SEE W.P.B. | | | AMEND. 106.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-04-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-03 |
Time |
14:24 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-03 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-28 |
Time |
15:15 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-02-28 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2008-02-28 15:40:36 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE ARCHITECTURAL FIRM LICENSE NUMBER MUST APPEAR IN | | | THE TITLE BLOCK OF EACH ARCHITECTURAL PLAN, SEE FAC | | | 61G1-16.004. | | | | | | 2) THE ARCHITECT (ANGELO LUIS LEBRON) MUST HAVE HIS | | | PRINTED NAME IN THE TITLE BLOCK, SEE SAME. | | | | | | 3) THE ARCHITECT MUST ALSO PUT THE DATE WHEN SIGNING | | | AND SEALING PLANS, SEE FAC 61G1-16.003. | | | | | | 4) THE ENGINEER MUST ALSO PUT THE DATE WHEN SIGNING AND | | | SEALING PLANS, SEE FAC 61G15-23.002. | | | | | | 5) THE ENGINEERING FIRM (MAY-BLANKENBEKER, INC.) MUST | | | HAVE THEIR CERTIFICATE OF AUTHORIZATION NUMBER IN THE | | | TITLE BLOCK OF EACH ENGINEERING PLAN, SEE FAC | | | 61G-23.002. | | | | | | 6) SEE PLAN M-2 TELECOM ROOM CRAC-1 UNIT HAS A NOTE #3 | | | NEXT TO IT. DO YOU WANT TO REMOVE DUCK AND CAP? PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-28 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-28 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-04 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-04 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2008-04-04 08:36:32 | DENIED; | | | 1. PAGE P1, DWV RISER; NO DEAD ENDS PERMITED IN THE | | | SANITARY DRAINAGE SYSTEM LONGER THAN 2'. FBC-PLUMBING | | | SECTION 704.5. | | | 2. PAGE A1.0 CLEAR FLOOR UNDER BREAK SINK TO COMPLY | | | WITH FBC-BUILDING SECTION 11-4.24.5 THE CLEAR FLOOR | | | SPACE SHALL EXTEND 19" UNDER THE SINK. | | | 3. PAGE A7.0 DETAIL 3; NO DOORS OR BASE PERMITED IN | | | FRONT OF BREAK ROOM SINK. SEE SECTION 11-4.24.3 KNEE | | | CLEARANCE 19"DEEP SHALL BE PROVIDED UNDERNEATH THE | | | SINK. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-02-29 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-02-29 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2008-02-29 10:04:40 | DENIED; | | | 1. WATER RISER DIAGRAM; WATER HAMMER ARRESTOR IS | | | REQUIRED AT BREAKICE BOX SEE FBC PLUMBING SECTION | | | 604.9. SPEC OUT SIZE AND MANUFACTURE ON PLANS. | | | 2. CONDENSATE FROM COMPUTER A/C TO DISCHARGE TO THE | | | OUTSIDE, STORM DRAINS OR TO CONDENSATE DRAINS. NOT | | | PERMITED TO GO TO SANITARY. WEST PALM BEACH UTILITY | | | ORD. | | | 3. BREAK SINK TO MEET ACCESSIBILITY CODE CHAPTER 11 OF | | | THE FBC BUILDING CODE. SEE SECTIONS 11-4.24.1 THRU | | | 11-4.24.7. SHOW THE FRONTAL CLEAR FLOOR SPACE ON FLOOR | | | PLANS . | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-27 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-27 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2008-02-27 13:26:59 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|