Plan Review Details - Permit 08020529
Plan Review Stops For Permit 08020529
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2008-02-26 Cont ID  
Sent By lursu Date 2008-02-26 Time 09:49 Rev Time 0.00
Received By lursu Date 2008-02-22 Time 14:31 Sent To  
Notes
2008-02-26 09:52:55FOR THE NEW HOUSE TO BE BUILT ON THIS PROPERTY THE NEW
 SITE ADDRESS TO USE IS 3630 NORTH SHORE DR , WEST PALM
 BEACH, FL 33407
  
 QUESTIONS/COMMENTS:
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]
2008-02-22 14:32:15COPY OF APPL. SENT TO LILLI

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-27 Cont ID  
Sent By lmartine Date 2008-10-27 Time 14:15 Rev Time 0.00
Received By lmartine Date 2008-10-27 Time 14:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-08-09 Cont ID  
Sent By amorse Date 2008-08-09 Time 07:39 Rev Time 0.00
Received By amorse Date 2008-08-09 Time 07:39 Sent To PC
Notes
2008-08-09 08:06:26 
  
 DENIED
  
 1)PROVIDE INSULATION VALUE FOR RAISED CONCRETE DECK
 ABOVE BREAKFAST AREA (BETWEEN CONDITIONED AND
 UNCONDITIONED SPACES). INCLUDE THIS AREA IN THE ENERGY
 CALCULATIONS.
  
 2)SHOW METHOD OF OF WATERPROOFING OR MEMBRANE TO BE
 USED ON TERRACE DECK, IF A MEMBRANE SUCH AS MODIFIED
 BITUMEN ROOF PRODUCT IS USED SUBMIT PRODUCT APPROVAL
 WITH APPROPRIATE METHOD TO BE USED.
  
 3)PRODUCT APPROVALS FOR THE PGT FIXED AND SINGLE HUNG
 WINDOWS ARE MISSING THE VALIDATION/INSTRUCTIONS THAT
 ARE PART OF THE STATE APPROVAL (IN THIS CASE MIAMI-DADE
 NOA), THEY ARE ALSO MISSING FOR THE PGT FRENCH DOORS
 AND THE GLASS BLOCK PRODUCTS.
  
 4)PLEASE NOTE THAT THE ID MARK "A"USED FOR THE
 SECOND FLOOR TIE DOWN STRAP ON ENTRY ROOF IS A POURED
 IN TYPE STRAP AND THE WALLS ARE WOOD FRAME.
  
 5)THE FLORIDA PRODUCT APPROVAL NUMBER FOR MGT GIRDER
 ANCHOR IS INCORRECT
  
 6)INSERT THE STRAP/TIEDOWN INFORMATION SHEETS INTO
 THE PRODUCT APPROVAL SETS (SEE ATTACHED COPIES OF
 STRAPS BEING USED)
  
 7)NO CONNECTOR WERE PROVIDED FOR EXTERIOR WOOD FRAME
 WALLS.
  
 8)THE APPROVED ENGINEERED TRUSS DRAWINGS ARE DESIGNED
 FOR 140 MPH EXPOSURE B BUT THE BUILDING IS DESIGNED TO
 140 MPH EXPOSURE C PLEASE CORRECT THE TRUSS DRAWINGS TO
 REFLECT DESIGNERS PARAMETERS. PLEASE NOTE THAT THE
 TRUSS DRAWINGS ARE NOT REQUIRE FOR PERMIT TO BE ISSUED
 BUT SIGNED AND SEALED APPROVED DRAWING ARE REQUIRED BY
 INSPECTOR BEFORE TRUSSES ARE SET.
  
 9)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS
 WITH REVISIONS.PLEASE RE-SUBMIT ANY PAGES WITH THE
 IMPACT FEE STAMP ALONG WITH COPY OF COUNTY RECEIPT
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-03-06 Cont ID  
Sent By amorse Date 2008-03-06 Time 14:07 Rev Time 0.00
Received By amorse Date 2008-03-06 Time 14:07 Sent To PC
Notes
2008-03-06 15:21:57 
  
 DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $1,047.92 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 3)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER
 AND OWNER/AGENT PRIOR
 TO SUBMITTAL. ALSO NO WALL TYPE AND R-VALUE WAS GIVEN
 FOR THE 2ND FLOOR EXTERIOR WOOD FRAME WALLS AT THE
 MASTER BEDROOM BALCONY AREA
  
 4)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 5)THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 6)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL SHEETS WHEN AVAILABLE. THEY CAN
 BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.WHEN
 AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED
  
 7)NO PRODUCT APPROVALS WERE SUBMITTED FOR GLASS
 BLOCK, MULLIONS, LINTELS, AND CONNECTORS AND STRAPS. IN
 LUE OF PRODUCT APPROVALS STRAPS/CONNECTORS MAY BE
 LISTED IN A SCHEDULE ON THE DRAWINGS COMPLETE WITH THE
 STATEWIDE PRODUCT APPROVAL NUMBERS OR SUBMIT SIMPSON
 TIE?S COMPLETE FLORIDA INDEX WITH CONNECTORS TO BE USED
 HIGHLIGHTED
  
 8)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH
 R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE
 INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD
  
 9)PLEASE NOTE THAT MORTAR JOINED GLASS BLOCK ONLY
 MEETS THE REQUIREMENT OF SMALL MISSILE IMPACT AND NOT
 LARGE MISSILE AS REQUIRED WHEN OPENINGS ARE WITHIN 30
 FEET OF GRADE
  
 10)DOES THE FIXED WINDOW PRODUCT APPROVAL COVER THE
 HALF CIRCLE ABOVE THE SINGLE HUNG UNITS AND THE FULL
 ROUND WINDOW AS THERE IS NO INFORMATION IN NOA
  
 11)THE NOA FOR THE ROOF TILES HAS EXPIRED, IT HAS
 BEEN RENEWED UNDER MIAMI-DADE NOA #07-0914.13
  
 12)PROVIDE INFORMATION THAT SHOWS BEDROOM 2 AND 3
 WINDOWS WILL MEET EGRESS REQUIREMENTS, MASTER BEDROOM
 DOES NOT REQUIRE EGRESS WINDOW AS DOORS ARE PROVIDED,
 ALSO NOTE THAT WINDOW SCHEDULE SHOWS DIFFERENT SIZES
 FOR THESE WINDOWS BUT ELEVATION SHOWS THEM AS IDENTICAL
 IN SIZE
  
 13)SECTION 2 ON SHEET S-3DOES NOT CORRESPOND WITH
 THE DESIGNATION FROM S-2, TRUSS JOISTS RUN
 PERPENDICULAR TO THE BEAM, ALSO BEAM IS SHOWNAS TYPE
 B2 ON PLAN AND TYPE B4 ON SECTION
  
 14)SECTION 3 ON S-3 SHOWS BEAM AS TYPE B4 AND THE
 PLAN ON S-2 SHOWS IT AS TYPE B5
  
 15)PROVIDE A DETAIL FOR REINFORCING STEEL LAYOUT IN
 ARCHED TIE BEAMS
  
 16)CORRECT NOTE #1 IN THE BEAM NOTES ON SHEET S-3 FOR
 ON CENTER SPACING
  
 17)CORRECT CHIMNEY CRICKET AND ROOF SHEATHING TO MEET
 THE REQUIREMENTS OF R1001.17 FBC RES. AND FIRE BLOCK
 GIRDER TRUSS AT CHIMNEY PER R1001.16 FBC RES. ON SHEET
 A-7 SECTION 3
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006
 AMENDMENTS
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 W/2006 AMENDMENTS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-10-22 Cont ID  
Sent By btrobaug Date 2008-10-22 Time 10:13 Rev Time 0.00
Received By btrobaug Date 2008-10-22 Time 09:21 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-07-21 Cont ID  
Sent By btrobaug Date 2008-07-21 Time 14:29 Rev Time 0.00
Received By btrobaug Date 2008-07-21 Time 13:15 Sent To M
Notes
2008-07-21 14:26:54 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS
 AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE
 FOLLOWING:
  
 THE FOLLOWING COMMENTS ARE FROM THE PREVIOUS REVIEW:
  
 3} 250.122(F)(1) BASED ON RATING OF OVERCURRENT
 PROTECTIVE DEVICE EACH PARALLEL EQUIPMENT GROUNDING
 CONDUCTOR SHALL BE SIZED ON THE BASIS OF THE AMPERE
 RATING OF THE OVERCURRENT DEVICE PROTECTING THE CIRCUIT
 CONDUCTORS IN THE RACEWAY OR CABLE IN ACCORDANCE WITH
 TABLE 250.122.SEE TABLE, THE #4 IN THE RISER DIAGRAM
 DOES NOT COMPLY.***SEE TABLE, A#3 IS REQUIRED FOR
 400AMP OCP.
  
 4} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT
 CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE
 EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS
 EQUAL TO OR GREATER THAN THE AVAILABLE FAULT.
  
 5} THE SERVICE GROUNDING ELECTRODE SYSTEM MUST BE RAN
 TO FOOTER STEEL TO COMPLY WITH 250.52(A)(3).INDICATE
 SAME ON RISER AND NOTES IN THE ELECTRICAL
 CALCULATION***THE RISER DIAGRAM INDICATES (2) 1/0
 GROUND RODS, NOT CONDUCTOR SIZE.
  
 12} THE LOCATION OF THE DISCONNECTS FOR THE AIR
 HANDLERS #1 & #2 DO NOT COMPLY WITH THE CLEARANCE
 REQUIREMENTS OF 110.26.
  
 FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN THE
 FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE LABEL THE
 ROOMS ON THE ELECTRICAL PLANS
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-02-25 Cont ID  
Sent By btrobaug Date 2008-02-25 Time 14:31 Rev Time 0.00
Received By btrobaug Date 2008-02-25 Time 10:42 Sent To M
Notes
2008-02-25 14:29:00 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NECK, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1}THE ELECTRICAL CALCULATIONS ON SHEET E1 INDICATE A
 200 AMP SERVICE WITH CONDUCTORS FOR THAT SIZE, SHEET E2
 INDICATES A 400 AMP SERVICE , SEE RISER DIAGRAM,
 CORRELATE SAME.
  
 2}LOCATE THE SERVICE EQUIPMENT, METER GUTTER AND MAIN
 DISCONNECT ON THE PLAN SO THAT COMPLIANCE WITH ARTICLES
 225 AND 230 CAN BE REVIEWED.
  
 3} 250.122(F)(1) BASED ON RATING OF OVERCURRENT
 PROTECTIVE DEVICE EACH PARALLEL EQUIPMENT GROUNDING
 CONDUCTOR SHALL BE SIZED ON THE BASIS OF THE AMPERE
 RATING OF THE OVERCURRENT DEVICE PROTECTING THE CIRCUIT
 CONDUCTORS IN THE RACEWAY OR CABLE IN ACCORDANCE WITH
 TABLE 250.122.SEE TABLE, THE #4 IN THE RISER DIAGRAM
 DOES NOT COMPLY.
  
 4} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT
 CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE
 EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS
 EQUAL TO OR GREATER THAN THE AVAILABLE FAULT.
  
 5} THE SERVICE GROUNDING ELECTRODE SYSTEM MUST BE RAN
 TO FOOTER STEEL TO COMPLY WITH 250.52(A)(3).INDICATE
 SAME ON RISER AND NOTES IN THE ELECTRICAL CALCULATION
  
 6} THERE IS NO "FIRST 10000VA" REDUCTION FOR
 CALCULATING THE NEUTRAL LOAD. SEE 220.61 AND ANNEX "D",
 PAGE 718, 2005 NEC.
  
 7} PANEL SCHEDULE "A, CIRCUITS #4 FOR THE FREEZER AND
 #6 WINE COOLER, THESE APPLIANCES WERE NOT IN THE LOAD
 CALCULATION.220.14(A).
  
 8} THE ELEVATOR IS NOT LISTED IN EITHER PANEL SEE 408.4
 2005 NEC.
  
 9} THE WHIRLPOOL CIRCUIT IS NOT LISTED IN THE PANEL
 SCHEDULE. SEE 680.56 FOR GFCI PROTECTION.
  
 10} THE KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.52(A), 210.52(C), AND 210.8(A)(6) GFI.
  
 11} THE EXERCISE ROOM, BREAKFAST ROOM AND THE OFFICE
 MUST COMPLY WITH THE SPACING REQUIREMENTS OF
 210.52(A)(1) AND (2).SEE REVIEWED PLAN FOR
 DEFICIENCIES.
  
 12} THE LOCATION OF THE DISCONNECTS FOR THE AIR
 HANDLERS #1 & #2 DO NOT COMPLY WITH THE CLEARANCE
 REQUIREMENTS OF 110.26.
  
 13} THE BRANCH CIRCUITS REQUIRED BY 620.23(A), (B) AND
 (C) ARE NOT LISTED ON THE PANEL SCHEDULE. 408.4.NEC.
  
 14} THE ELEVATOR DISCONNECT IN THE ATTIC DOES NOT
 COMPLY WITH 110.26 OR 620.51(C). IT CAN BE LOCATED IN
 THE MECHANICAL ROOM.
  
 15} A NOTE ON SHEET E2 INDICATES THE A/C IS IN THE
 ATTIC, BUT SHOWN IN A CLOSET ALSO SAME LOCATION ON THE
 MECHANICAL PLAN, CORRELATE LOCATION.
  
 16} BEDROOMS 2 & 3 SHEET E2 RECEPTACLE SPACING MUST
 COMPLY WITH 210.52(A)(1) AND 210.52(A)(2). 2005 NEC.
 SEE REVIEWED PLAN FOR DEFICIENCIES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-02-27 Cont ID  
Sent By adarroug Date 2009-02-27 Time 10:01 Rev Time 0.00
Received By adarroug Date 2009-02-27 Time 10:01 Sent To M
Notes
2009-02-27 10:02:56TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-10-15 Cont ID  
Sent By adarroug Date 2008-10-15 Time 16:01 Rev Time 0.00
Received By adarroug Date 2008-10-15 Time 16:01 Sent To Z
Notes
2008-10-15 16:01:52TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-18 Cont ID  
Sent By adarroug Date 2008-07-18 Time 14:15 Rev Time 0.00
Received By adarroug Date 2008-07-18 Time 14:15 Sent To E
Notes
2008-07-18 14:15:58TO "BTROBAUGH" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-10 Cont ID  
Sent By adarroug Date 2008-07-10 Time 12:14 Rev Time 0.00
Received By adarroug Date 2008-07-10 Time 12:14 Sent To Z
Notes
2008-07-10 12:14:45TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-07-10 Cont ID  
Sent By adarroug Date 2008-03-06 Time 12:13 Rev Time 0.00
Received By adarroug Date 2008-02-22 Time 14:32 Sent To  
Notes
2008-02-22 14:32:32TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2008-10-17 Cont ID  
Sent By rkussner Date 2008-10-17 Time 13:35 Rev Time 0.00
Received By rkussner Date 2008-10-17 Time 13:35 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-07-16 Cont ID  
Sent By rkussner Date 2008-07-16 Time 14:55 Rev Time 0.00
Received By rkussner Date 2008-07-17 Time 09:03 Sent To  
Notes
2008-07-17 09:18:20PLEASE PROVIDE THE SPACING FOR ALL PROPOSED PLANT
 MATERIAL.
  
 THE PROPOSED QUEEN PALMS IN THE REAR OF THE SITE ARE
 SHOWN WITHIN A UTILITY EASEMENT.PLEASE OBTAIN WRITTEN
 APPROVAL FROM THE EASEMENT HOLDER TO PLANT WITHIN THE
 EASEMENT OR REMOVE THEM.
  
 YOU MUST FOLLOW THE FPL GUIDELINES FOR PLANTING TREES
 NEAR OR UNDER POWER LINES.THIS INFORMATION CAN BE
 OBTAINED BY GETTING ONTO THE FPL WEBSITE AND LOOK UP
 "PLANT THE RIGHT TREE IN THE RIGHT PLACE".
  
 THE LAYOUT OF THE REAR PATIO SHOWN ON THE LANDSCAPE
 PLAN IS NOT CONSISTENT WITH THE SITE PLAN.ALL PLANS
 MUST BE CONSISTENT.
  
 SHOW THE CANOPY OF ALL TREES ON NEIGHBORING PROPERTIES
 THAT ARE IN CLOSE PROXIMITY TO THIS SITE, TO AVOID
 CONFLICTS WITH WHAT IS BEING PROPOSED.
  
 PROVIDE SOD AND IRRIGATION IN THE RIGHT-OF-WAY.
  
 PROVIDE LANDSCAPE CALCULATIONS BASED UPON SECTION
 94-441 OF THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS (REQUIRED AND PROVIDED).
  
 SHOW ALL UTILITIES ON LANDSCAPE PLAN TO AVOID
 CONFLICTS.
  
  
 PLEASE CONTACT ROBERT KUSSNER AT (561) 822-1462 IF YOU
 HAVE ANY QUESTIONS REGARDING THE LANDSCAPE COMMENTS.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2009-03-13 Cont ID  
Sent By rregueir Date 2009-03-13 Time 10:37 Rev Time 0.00
Received By rregueir Date 2009-03-13 Time 10:37 Sent To PC
Notes
2009-03-13 10:37:41REVISED AC-1 AND AC-2

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-10-22 Cont ID  
Sent By tgordon Date 2008-10-22 Time 16:19 Rev Time 0.45
Received By tgordon Date 2008-10-22 Time 16:19 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-07-22 Cont ID  
Sent By tgordon Date 2008-07-22 Time 08:31 Rev Time 1.15
Received By tgordon Date 2008-07-22 Time 08:31 Sent To P
Notes
2008-07-22 09:04:39PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) THE COOLING LOAD CALCULATIONS FOR A/C 3 ARE CALLING
 FOR 34,067 TOTAL COOLING BTU'S, THE MECHANICAL PLAN
 EQUIPMENT SCHEDULE FOR SYSTEM 3 SHOWS 42,000 TOTAL
 COOLING BTU'S, THE PLANS CAN ONLY CALL FOR 15% MORE
 TOTAL COOLING BTU'S THAN THE COOLING LOAD CALCULATIONS,
 PER 2004 FBC 13-607.1.ABC.1.1. PLEASE CORRECT (A 3.5
 TON SYSTEM IS TO LARGE A 3.0 TON SYSTEM WILL MEET THE
 COOLING LOAD REQUIREMENTS).
  
 2) SEE MECHANICAL PLANS EQUIPMENT SCHEDULE. THE AIR
 HANDLER AND CONDENSER UNIT MODEL NUMBERS ARE
 FLIP-FLOPPED FOR ALL SYSTEMS, PLEASE CORRECT.
  
 3) THE FOLLOWING SUPPLY AIR DUCTS STILL NEED TO BE
 SIZED. A/C SYSTEM 1, MAIN TRUNK LINE OVER THE OFFICE,
 THE FLEX DUCT AND GRILL FROM THE MAIN TRUNK LINE TO THE
 HALL BY THE EXERCISE ROOM. A/C SYSTEM 2, THE FLEX DUCT
 FROM THE MAIN TRUNK LINE TO THE MIXING BOX NEAR THE
 20X20 RETURN AIR GRILL, THE FLEX AND GRILL FROM THE
 SAME MIXING BOX TO THE HALL. A/C SYSTEM 3, THE FLEX
 FROM THE MAIN TRUNK LINE TO THE MIXING BOX OVER BEDROOM
 #2, THE FLEX FROM THE MAIN TRUNK LINE TO THE MIXING BOX
 OVER THE MASTER BEDROOM, AND THE FLEX FROM THE MAIN
 TRUNK LINE TO THE MISSING BOX OVER THE MASTER BEDROOM
 CLOSET. SEE YELLOW HIGH LIGHTS ON MECHANICAL PLANS,
 PLEASE CORRECT PER 2004 WPB AMEND. 106.3.5.4 (10).
  
 4) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, SEE F.B.C. 106.1.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-02-26 Cont ID  
Sent By tgordon Date 2008-02-26 Time 08:08 Rev Time 1.00
Received By tgordon Date 2008-02-26 Time 08:08 Sent To P
Notes
2008-02-26 08:37:56PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 2) PLEASE ADD AN A/C EQUIPMENT SCHEDULE TO MECHANICAL
 PLAN, PER 2004 WPB AMEND. 106.3.5.4 (10).
  
 3) SEE AIR HANDLER #1 RETURN AIR THROUGH 20X20 GRILL IN
 DOOR, IF THE POCKET DOOR AT THE SERVICE HALL AND MAIN
 HALL IS CLOSED THAN AIR CAN NOT RETURN TO THE AIR
 HANDLER, PLEASE CORRECT, PER 2004 FBC/R M1602.4.
  
 4) PLEASE CLARIFY ON PLAN HOW AIR IS TO RETURN TO AIR
 HANDLER #1, SEE 2004 FBC/R M1602.4.
  
 5) SEE AIR HANDLER #3 RETURN AIR DUCTS FROM BEDROOMS IS
 NOT CONNECTED TO THE AIR HANDLER AND WILL NOT LET AIR
 RETURN TO THE AIR HANDLER, PLEASE CORRECT.
  
 6) SEE AIR HANDLER #3 IF THE 20X20 RETURN AIR GRILL IS
 IN THE CLOSET AND THE DOOR IS CLOSED THEN AIR WILL NOT
 RETURN TO THE AIR HANDLER, PLEASE CORRECT.
  
 6) SEE YELLOW HIGH LIGHT ON MECHANICAL PLANS A/C1 AND
 A/C2 SHOWING SUPPLY AIR DUCTS THAT NEED TO BE SIZED,
 PER 2004 WPB AMEND. 106.3.5.4 (10).
  
 ** PER 2004 FBC/R M1602.4BALANCED RETURN AIR MAY BE
 ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE
 RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS
 SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR
 HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO
 ACHIEVE PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50 SQUARE INCHES (OF
 GRILLE AREA) TO 100 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND USING AN
 UNRESTRICTED 1-INCH UNDERCUTTING OF DOORS TO ACHIEVE
 PROPER RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET
 THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR
 EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY
 ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-10-23 Cont ID  
Sent By mperson Date 2008-10-23 Time 10:47 Rev Time 1.00
Received By mperson Date 2008-10-23 Time 10:47 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-07-23 Cont ID  
Sent By mperson Date 2008-07-23 Time 15:13 Rev Time 0.00
Received By mperson Date 2008-07-23 Time 15:12 Sent To B
Notes
2008-07-23 16:20:26PLUMBING PLAN REVIEW:
 DENIED **2ND TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE
 DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. WATER HEATER DETAILS; SHOW TYPE OF THERMAL
 EXPANSION TO BE USED PER SECTION 607.3. IF A HEATER PAN
 IS USED ON FIRST FLOOR A PAN DRAIN IS REQUIRED AND MUST
 GO OUTSIDE BUILDING SECTION 504.7.2.
  
 **RESPONSE NOTED AND COMMENT WAS PARTIALLY ADDRESSED,
 HOWEVER THE INSTALLATION OF A CHECK VALVE IS NOT
 PROTECTION AGAINST THERMAL EXPANSION.THE INSTALLATION
 OF AN EXPANSION TANK OR A CALIBRATED PRESSURE RELIEF
 VALVE ARE EXAMPLES OF A MEANS FOR THERMAL EXPANSION
 CONTROL. CLEARLY INDICATE THE LOCATION OF THE THERMAL
 EXPANSION CONTROL DEVICE USED ON RESUBMITTED P1 & P2
 SHEETS. PER FBC-PLUMBING SECTION 607.3.
  
 2. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE 3" TO
 SANITARY TEE SECTION 406.3.
  
 **RESPONSE NOTED, HOWEVER SHEET P1 FIRST FLOOR PLAN-
 PLUMBING IS STILL INDICATING THE WRONG BRANCH DRAIN
 PIPE SIZE OF 2" FOR THE WASHING MACHINE. PLEASE CORRECT
 AND CORRELATE WITH THE SANITARY RISER ON SHEET P2. PER
 FBC- PLUMBING SECTION 406.3.
  
 3. WATER RISER DIAGRAM; ONLY ON THE WATER HEATER
 SHOWN. T &P DISCHARGE PIPE TO BE 3/4" (ON WATER
 HEATER SHOWN) SHOCK ARRESTORS ARE NOT REQUIRED ON ALL
 FIXTURES, SEE SECTION 604.9.
  
 **RESPONSE NOTED AND COMMENT WAS PARTIALLY ADDRESSED,
 HOWEVER SHOCK ARRESTORS (WATER-HAMMER ARRESTORS) ARE
 REQUIRED TO BE INSTALLED WHERE QUICK CLOSING VALVES ARE
 UTILIZED. (EXAMPLES OF QUICK CLOSING VALVES ARE=
 WASHING MACHINES, DISHWASHERS, & ICE MAKERS). CLEARLY
 INDICATE THE REQUIRED WATER-HAMMER ARRESTORS ON BOTH
 THE HOT/COLD WATER SUPPLY TO THE WASHING MACHINE. THE
 RISER DIAGRAM INDICATES THE WATER-HAMMER ARRESTOR
 MISSING FROM THE HOT WATER SUPPLY TO THE WASHING
 MACHINE. WATER-HAMMER ARRESTOR IS ALSO REQUIRED ON THE
 HOT WATER SUPPLY TO THE DISHWASHER. PLEASE CORRECT THIS
 ON THE RESUBMITTAL. PER FBC- PLUMBING SECTION 604.9.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-02-26 Cont ID  
Sent By jleech Date 2008-02-26 Time 13:01 Rev Time 0.00
Received By jleech Date 2008-02-26 Time 12:48 Sent To B
Notes
2008-02-26 13:21:21DENIED;
 1. WATER HEATER DETAILS; SHOW TYPE OF THERMAL EXPANION
 TO BE USED PER FBC PLUMBING SECTION 607.3. IF A HEATER
 PAN IS USED ON FIRST FLOOR PAN DRAIN IS REQUIRED AND
 MUST GO TO OUT SIDE SECTION 504.7.2.
 2. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE 3" TO
 SANITARY TEE SECTION 406.3.
 3. WATER RISER DIAGRAM; ONLY ON WATER HEATER SHOWN. T &
 P DISCHARGE PIPE TO BE 3/4"( ON HEATER SHOWN.) SHOCK
 ARRESTORS ARE NOT REQUIRED ON ALL FIXTURES SEE SECTION
 604.9
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2008-10-17 Cont ID  
Sent By adavila Date 2008-10-17 Time 14:01 Rev Time 0.00
Received By adavila Date 2008-10-17 Time 12:22 Sent To I
Notes
2008-10-17 14:02:14PER ERIC SCHNEIDER, PRINCIPAL PLANNER.
  
 ALL WALLS AND FENCES SHALL BE APPROVED ON A SEPARATE
 PERMIT.
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2008-07-17 Cont ID  
Sent By adavila Date 2008-07-17 Time 09:24 Rev Time 0.00
Received By adavila Date 2008-07-16 Time 13:32 Sent To  
Notes
2008-07-17 09:24:31PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PROVIDE 2 COPIES OF A SIGNED AND SEALED SURVEY.
 SURVEY SHALL BE NO MORE THAN 1 YEAR OLD.
  
 2. SITE PLAN SHOWS 2 WALLS WITH GATES WITHIN THE SIDE
 SETBACKS.PLEASE NOTE THAT ALL WALLS AND FENCES SHALL
 BE APPROVED ON A SEPARATE PERMIT.DETAILS OF THE WALLS
 AND GATES, TO INCLUDE THE APPROVED EASEMENT CONSENT
 FORM FROM THE CITY OF WEST PALM BEACH WATER UTILITIES
 DEPARTMENT, SHALL BE SUBMITTED WITH THE FENCE PERMIT
 APPLICATION.PLEASE NOTE THAT THE OVERALL HEIGHT OF
 THE WALLS AND GATES SHALL NOT EXCEED 6 FEET IN HEIGHT
 MEASURED FROM THE OUTSIDE GRADE.ANY DECORATIVE
 ELEMENTS ON TOP OF THE WALLS/GATES SHALL NOT EXCEED 10
 PERCENT OF 6 FEET.
  
 3. THERE IS A DISCREPANCY BETWEEN THE SITE PLAN AND
 LANDSCAPE PLAN IN REGARDS TO THE LOCATION, DIMENSIONS
 AND AREA OF THE PATIO AT THE REAR OF THE PROPERTY.
 PLEASE REVISE.
  
 4. PLEASE ENSURE THAT ALL PLANS MATCH AND SHOW SAME
 CONDITIONS.DISCREPANCY BETWEEN ANY OF THE PLANS WILL
 DELAY BUILDING PERMIT APPROVAL.
  
 5. IT APPEARS THAT TREES ARE BEING PROPOSED WITHIN THE
 UTILITY EASEMENT ALONG THE REAR PROPERTY LINE.TREES
 SHALL NOT BE LOCATED WITHIN AN EASEMENT.LANDSCAPE
 PLAN SHALL SHOW ALL UTILITY EASEMENTS WITHIN THE
 PROPERTY.
  
 6. IRRIGATION SHALL BE APPROVED ON A SEPARATE PERMIT.
 PROVIDE IRRIGATION PLAN AND DETAILS WITH THE IRRIGATION
 PERMIT APPLICATION.
  
 7. PAVER SHALL BE UNSEALED FOR THE DRIVEWAY TO BE A
 PERMEABLE SURFACE.
  
 8. REPEAT COMMENT - PROVIDE HEIGHT DIMENSIONS ON
 ELEVATIONS (SHEETS A4 AND A5) FROM GRADE TO THE
 MIDPOINT OF THE ROOF?S PITCH.
 A. THE HEIGHT DIMENSIONS PROVIDED ARE FROM THE FIRST
 FLOOR ELEVATION AND NOT FROM GRADE.OVERALL BUILDING
 HEIGHT DIMENSION, AS DEFINED IN THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDRS), SHALL BE PROVIDED FROM
 GRADE ON ALL ELEVATIONS.
  
 9. PROVIDE HEIGHT DIMENSIONS TO THE HIGHEST POINT OF
 THE CHIMNEY.
  
 10. IDENTIFY THE OBJECT SHOWN ON THE REAR SIDE OF THE
 PROPERTY ON THE NORTH ELEVATION.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-02-22 Cont ID  
Sent By choops Date 2008-02-22 Time 15:16 Rev Time 0.00
Received By choops Date 2008-02-22 Time 15:16 Sent To E
Notes
2008-02-22 15:38:14***FAILED***
  
  
 1)AN APPROVED EASEMENT CONSENT FORM FROM THE CITY OF
 WEST PALM BEACH DEPARTMENT OF PUBLIC UTILITIES (1ST
 FLOOR CITY HALL) IS REQUIRED FOR ALL PROPOSED
 FENCES/WALLS.
  
 2)INDICATE HEIGHT DIMENSIONS OF THE PROPOSED WALL
 WITH FENCING, DIMENSIONS SHALL BE SHOWN FROM GRADE.
 NOTE: PURSUANT TO THE CITY OF WEST PALM BEACH ZONING
 AND LAND DEVELOPMENT REGULATIONS, SECTION 94-302(B)(1):
 MAXIMUM HEIGHT.IN RESIDENTIAL DISTRICTS, NO FENCE OR
 WALL SHALL EXCEED SIX FEET IN HEIGHT WITHIN REQUIRED
 SIDE AND REAR SETBACKS. FENCES OR WALLS SHALL NOT BE IN
 EXCESS OF 48 INCHES IN HEIGHT WITHIN THE REQUIRED FRONT
 SETBACK. HEDGES SHALL NOT EXCEED TEN FEET IN HEIGHT IN
 ANY REQUIRED SETBACK.
  
 3)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDRS): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 4)BOUNDARIES OF THE REAR PATIO SHALL BE CLEARLY
 DEFINED.THE SITE PLAN (SHEET A1) DOES NOT CLEARLY
 SHOW THE REAR PATIO.NOTE:PATIO OR PAVED AREAS SHALL
 DRAIN ADEQUATELY, HOWEVER, MAINTAIN ALL DRAINAGE WITHIN
 THE PROPERTY SO-AS NOT TO DRAIN ONTO ADJACENT
 PROPERTIES.
  
 5)PLEASE SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE
 WITH SECTION 94-442 AND 94-445 OF THE ZLDRS.
  
 6)PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES LOCATED WITHIN THE FRONT YARD (FROM FRONT
 PROPERTY LINE TO THE FRONT BUILDING FACADE).PURSUANT
 TO SECTION 94-482 OF THE ZLDRS: REQUIRED OFF-STREET
 PARKING SPACES FOR LESS THAN FOUR RESIDENTIAL DWELLING
 UNITS SHALL BE LOCATED ON THE PROPERTY ON WHICH THE
 UNITS ARE CONSTRUCTED. REQUIRED PARKING MAY BE LOCATED
 IN A FRONT YARD; HOWEVER, THE LESSER OF 1,000 SQUARE
 FEET OR 75 PERCENT OF THE FRONT YARD AREA MUST BE
 LANDSCAPED. PARKING AREAS LOCATED IN THE FRONT YARD
 SHALL BE SURFACED WITH A SMOOTH, NONDUSTING SURFACE IN
 COMPLIANCE WITH SUBSECTION 33-485(E). IT SHALL BE A
 VIOLATION OF THIS CHAPTER TO PARK ON ANY UNPAVED AREAS
 AS DESCRIBED IN THIS ARTICLE.NOTE: TOTAL IMPERMEABLE
 SURFACE WITHIN THE FRONT YARD SHALL NOT EXCEED 1,125
 SQ.FT..
  
 7)PROVIDE HEIGHT DIMENSIONS ON ELEVATIONS (SHEETS A4
 AND A5) FROM GRADE TO THE MIDPOINT OF THE ROOF'S PITCH.
 NOTE:PURSUANT TO SECTION 94-72 OF THE ZLDRS THIS
 DIMENSION SHALL NOT EXCEED 30 FEET.
  
 8)SHEET A2, A4, AND A5 SHOW A SPA AT THE REAR.IF
 THE SPA IS NOT TO BE INCLUDED IN THE SCOPE OF WORK
 UNDER THIS PERMIT, IT SHALL BE DELETED FROM THE PLANS
 OR LABELED "PERMITTED SEPARATELY."IF THE SPA IS TO BE
 INCLUDED UNDER THIS PERMIT, A SPA DETAIL MUST BE
 PROVIDED SHOWING THE DIMENSIONS AND HEIGHT.
 ADDITIONALLY, SETBACK DIMENSIONS SHALL BE SHOWN FROM
 THE PROPERTY LINES TO THE WATER'S EDGE.A FENCE
 ENCLOSURE WILL BE REQUIRED, AND ANY SPA EQUIPMENT SHALL
 BE SHOWN WITH SETBACK DIMENSIONS TO THE PROPERTY LINES.
 NOTE:PURSUANT TO SECTION 94-304 OF THE ZLDRS: SPA
 MUST MAINTAIN A MINIMUM SETBACK OF 5 FEET TO SIDE AND
 REAR PROPERTY LINES FROM WATER'S EDGE.SPA NOT
 PERMITTED TO BE BUILT WITHIN THE REAR UTILITY
 EASEMENT.
  
  
 NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - SF RACK