| Plan Review Stops For Permit 08020529 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-02-26 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-02-22 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2008-02-26 09:52:55 | FOR THE NEW HOUSE TO BE BUILT ON THIS PROPERTY THE NEW | | | SITE ADDRESS TO USE IS 3630 NORTH SHORE DR , WEST PALM | | | BEACH, FL 33407 | | | | | | QUESTIONS/COMMENTS: | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | 2008-02-22 14:32:15 | COPY OF APPL. SENT TO LILLI |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-10-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-10-27 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-10-27 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-08-09 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-08-09 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-08-09 |
Time |
07:39 |
Sent To |
PC |
|
| Notes |
| 2008-08-09 08:06:26 | | | | | | | DENIED | | | | | | 1)PROVIDE INSULATION VALUE FOR RAISED CONCRETE DECK | | | ABOVE BREAKFAST AREA (BETWEEN CONDITIONED AND | | | UNCONDITIONED SPACES). INCLUDE THIS AREA IN THE ENERGY | | | CALCULATIONS. | | | | | | 2)SHOW METHOD OF OF WATERPROOFING OR MEMBRANE TO BE | | | USED ON TERRACE DECK, IF A MEMBRANE SUCH AS MODIFIED | | | BITUMEN ROOF PRODUCT IS USED SUBMIT PRODUCT APPROVAL | | | WITH APPROPRIATE METHOD TO BE USED. | | | | | | 3)PRODUCT APPROVALS FOR THE PGT FIXED AND SINGLE HUNG | | | WINDOWS ARE MISSING THE VALIDATION/INSTRUCTIONS THAT | | | ARE PART OF THE STATE APPROVAL (IN THIS CASE MIAMI-DADE | | | NOA), THEY ARE ALSO MISSING FOR THE PGT FRENCH DOORS | | | AND THE GLASS BLOCK PRODUCTS. | | | | | | 4)PLEASE NOTE THAT THE ID MARK "A"USED FOR THE | | | SECOND FLOOR TIE DOWN STRAP ON ENTRY ROOF IS A POURED | | | IN TYPE STRAP AND THE WALLS ARE WOOD FRAME. | | | | | | 5)THE FLORIDA PRODUCT APPROVAL NUMBER FOR MGT GIRDER | | | ANCHOR IS INCORRECT | | | | | | 6)INSERT THE STRAP/TIEDOWN INFORMATION SHEETS INTO | | | THE PRODUCT APPROVAL SETS (SEE ATTACHED COPIES OF | | | STRAPS BEING USED) | | | | | | 7)NO CONNECTOR WERE PROVIDED FOR EXTERIOR WOOD FRAME | | | WALLS. | | | | | | 8)THE APPROVED ENGINEERED TRUSS DRAWINGS ARE DESIGNED | | | FOR 140 MPH EXPOSURE B BUT THE BUILDING IS DESIGNED TO | | | 140 MPH EXPOSURE C PLEASE CORRECT THE TRUSS DRAWINGS TO | | | REFLECT DESIGNERS PARAMETERS. PLEASE NOTE THAT THE | | | TRUSS DRAWINGS ARE NOT REQUIRE FOR PERMIT TO BE ISSUED | | | BUT SIGNED AND SEALED APPROVED DRAWING ARE REQUIRED BY | | | INSPECTOR BEFORE TRUSSES ARE SET. | | | | | | 9)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS | | | WITH REVISIONS.PLEASE RE-SUBMIT ANY PAGES WITH THE | | | IMPACT FEE STAMP ALONG WITH COPY OF COUNTY RECEIPT | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-03-06 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-03-06 |
Time |
14:07 |
Sent To |
PC |
|
| Notes |
| 2008-03-06 15:21:57 | | | | | | | DENIED | | | | | | 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* | | | | | | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | | ADDED TO THE PERMIT APPLICATION FEES | | | | | | NOTE: FEES ARE DUE IN THE AMOUNT OF $1,047.92 FOR | | | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS | | | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW | | | | | | 3)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | | AND OWNER/AGENT PRIOR | | | TO SUBMITTAL. ALSO NO WALL TYPE AND R-VALUE WAS GIVEN | | | FOR THE 2ND FLOOR EXTERIOR WOOD FRAME WALLS AT THE | | | MASTER BEDROOM BALCONY AREA | | | | | | 4)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | | | 5)THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | 6)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | | STATE PRODUCT APPROVAL SHEETS WHEN AVAILABLE. THEY CAN | | | BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.WHEN | | | AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE | | | DENIED | | | | | | 7)NO PRODUCT APPROVALS WERE SUBMITTED FOR GLASS | | | BLOCK, MULLIONS, LINTELS, AND CONNECTORS AND STRAPS. IN | | | LUE OF PRODUCT APPROVALS STRAPS/CONNECTORS MAY BE | | | LISTED IN A SCHEDULE ON THE DRAWINGS COMPLETE WITH THE | | | STATEWIDE PRODUCT APPROVAL NUMBERS OR SUBMIT SIMPSON | | | TIE?S COMPLETE FLORIDA INDEX WITH CONNECTORS TO BE USED | | | HIGHLIGHTED | | | | | | 8)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH | | | R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE | | | INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY | | | THE DESIGNER OF RECORD | | | | | | 9)PLEASE NOTE THAT MORTAR JOINED GLASS BLOCK ONLY | | | MEETS THE REQUIREMENT OF SMALL MISSILE IMPACT AND NOT | | | LARGE MISSILE AS REQUIRED WHEN OPENINGS ARE WITHIN 30 | | | FEET OF GRADE | | | | | | 10)DOES THE FIXED WINDOW PRODUCT APPROVAL COVER THE | | | HALF CIRCLE ABOVE THE SINGLE HUNG UNITS AND THE FULL | | | ROUND WINDOW AS THERE IS NO INFORMATION IN NOA | | | | | | 11)THE NOA FOR THE ROOF TILES HAS EXPIRED, IT HAS | | | BEEN RENEWED UNDER MIAMI-DADE NOA #07-0914.13 | | | | | | 12)PROVIDE INFORMATION THAT SHOWS BEDROOM 2 AND 3 | | | WINDOWS WILL MEET EGRESS REQUIREMENTS, MASTER BEDROOM | | | DOES NOT REQUIRE EGRESS WINDOW AS DOORS ARE PROVIDED, | | | ALSO NOTE THAT WINDOW SCHEDULE SHOWS DIFFERENT SIZES | | | FOR THESE WINDOWS BUT ELEVATION SHOWS THEM AS IDENTICAL | | | IN SIZE | | | | | | 13)SECTION 2 ON SHEET S-3DOES NOT CORRESPOND WITH | | | THE DESIGNATION FROM S-2, TRUSS JOISTS RUN | | | PERPENDICULAR TO THE BEAM, ALSO BEAM IS SHOWNAS TYPE | | | B2 ON PLAN AND TYPE B4 ON SECTION | | | | | | 14)SECTION 3 ON S-3 SHOWS BEAM AS TYPE B4 AND THE | | | PLAN ON S-2 SHOWS IT AS TYPE B5 | | | | | | 15)PROVIDE A DETAIL FOR REINFORCING STEEL LAYOUT IN | | | ARCHED TIE BEAMS | | | | | | 16)CORRECT NOTE #1 IN THE BEAM NOTES ON SHEET S-3 FOR | | | ON CENTER SPACING | | | | | | 17)CORRECT CHIMNEY CRICKET AND ROOF SHEATHING TO MEET | | | THE REQUIREMENTS OF R1001.17 FBC RES. AND FIRE BLOCK | | | GIRDER TRUSS AT CHIMNEY PER R1001.16 FBC RES. ON SHEET | | | A-7 SECTION 3 | | | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | | AMENDMENTS | | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | | AMENDMENTS TO FBC | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | FBC RES. = FLORIDA BUILDING CODE | | | RESIDENTIAL 2004 W/2006 AMENDMENTS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-10-22 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-10-22 |
Time |
09:21 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-07-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-21 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-21 |
Time |
13:15 |
Sent To |
M |
|
| Notes |
| 2008-07-21 14:26:54 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | THE FOLLOWING COMMENTS ARE FROM THE PREVIOUS REVIEW: | | | | | | 3} 250.122(F)(1) BASED ON RATING OF OVERCURRENT | | | PROTECTIVE DEVICE EACH PARALLEL EQUIPMENT GROUNDING | | | CONDUCTOR SHALL BE SIZED ON THE BASIS OF THE AMPERE | | | RATING OF THE OVERCURRENT DEVICE PROTECTING THE CIRCUIT | | | CONDUCTORS IN THE RACEWAY OR CABLE IN ACCORDANCE WITH | | | TABLE 250.122.SEE TABLE, THE #4 IN THE RISER DIAGRAM | | | DOES NOT COMPLY.***SEE TABLE, A#3 IS REQUIRED FOR | | | 400AMP OCP. | | | | | | 4} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT | | | CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE | | | EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS | | | EQUAL TO OR GREATER THAN THE AVAILABLE FAULT. | | | | | | 5} THE SERVICE GROUNDING ELECTRODE SYSTEM MUST BE RAN | | | TO FOOTER STEEL TO COMPLY WITH 250.52(A)(3).INDICATE | | | SAME ON RISER AND NOTES IN THE ELECTRICAL | | | CALCULATION***THE RISER DIAGRAM INDICATES (2) 1/0 | | | GROUND RODS, NOT CONDUCTOR SIZE. | | | | | | 12} THE LOCATION OF THE DISCONNECTS FOR THE AIR | | | HANDLERS #1 & #2 DO NOT COMPLY WITH THE CLEARANCE | | | REQUIREMENTS OF 110.26. | | | | | | FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN THE | | | FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE LABEL THE | | | ROOMS ON THE ELECTRICAL PLANS | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-25 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-25 |
Time |
10:42 |
Sent To |
M |
|
| Notes |
| 2008-02-25 14:29:00 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NECK, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1}THE ELECTRICAL CALCULATIONS ON SHEET E1 INDICATE A | | | 200 AMP SERVICE WITH CONDUCTORS FOR THAT SIZE, SHEET E2 | | | INDICATES A 400 AMP SERVICE , SEE RISER DIAGRAM, | | | CORRELATE SAME. | | | | | | 2}LOCATE THE SERVICE EQUIPMENT, METER GUTTER AND MAIN | | | DISCONNECT ON THE PLAN SO THAT COMPLIANCE WITH ARTICLES | | | 225 AND 230 CAN BE REVIEWED. | | | | | | 3} 250.122(F)(1) BASED ON RATING OF OVERCURRENT | | | PROTECTIVE DEVICE EACH PARALLEL EQUIPMENT GROUNDING | | | CONDUCTOR SHALL BE SIZED ON THE BASIS OF THE AMPERE | | | RATING OF THE OVERCURRENT DEVICE PROTECTING THE CIRCUIT | | | CONDUCTORS IN THE RACEWAY OR CABLE IN ACCORDANCE WITH | | | TABLE 250.122.SEE TABLE, THE #4 IN THE RISER DIAGRAM | | | DOES NOT COMPLY. | | | | | | 4} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT | | | CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE | | | EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS | | | EQUAL TO OR GREATER THAN THE AVAILABLE FAULT. | | | | | | 5} THE SERVICE GROUNDING ELECTRODE SYSTEM MUST BE RAN | | | TO FOOTER STEEL TO COMPLY WITH 250.52(A)(3).INDICATE | | | SAME ON RISER AND NOTES IN THE ELECTRICAL CALCULATION | | | | | | 6} THERE IS NO "FIRST 10000VA" REDUCTION FOR | | | CALCULATING THE NEUTRAL LOAD. SEE 220.61 AND ANNEX "D", | | | PAGE 718, 2005 NEC. | | | | | | 7} PANEL SCHEDULE "A, CIRCUITS #4 FOR THE FREEZER AND | | | #6 WINE COOLER, THESE APPLIANCES WERE NOT IN THE LOAD | | | CALCULATION.220.14(A). | | | | | | 8} THE ELEVATOR IS NOT LISTED IN EITHER PANEL SEE 408.4 | | | 2005 NEC. | | | | | | 9} THE WHIRLPOOL CIRCUIT IS NOT LISTED IN THE PANEL | | | SCHEDULE. SEE 680.56 FOR GFCI PROTECTION. | | | | | | 10} THE KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. | | | | | | 11} THE EXERCISE ROOM, BREAKFAST ROOM AND THE OFFICE | | | MUST COMPLY WITH THE SPACING REQUIREMENTS OF | | | 210.52(A)(1) AND (2).SEE REVIEWED PLAN FOR | | | DEFICIENCIES. | | | | | | 12} THE LOCATION OF THE DISCONNECTS FOR THE AIR | | | HANDLERS #1 & #2 DO NOT COMPLY WITH THE CLEARANCE | | | REQUIREMENTS OF 110.26. | | | | | | 13} THE BRANCH CIRCUITS REQUIRED BY 620.23(A), (B) AND | | | (C) ARE NOT LISTED ON THE PANEL SCHEDULE. 408.4.NEC. | | | | | | 14} THE ELEVATOR DISCONNECT IN THE ATTIC DOES NOT | | | COMPLY WITH 110.26 OR 620.51(C). IT CAN BE LOCATED IN | | | THE MECHANICAL ROOM. | | | | | | 15} A NOTE ON SHEET E2 INDICATES THE A/C IS IN THE | | | ATTIC, BUT SHOWN IN A CLOSET ALSO SAME LOCATION ON THE | | | MECHANICAL PLAN, CORRELATE LOCATION. | | | | | | 16} BEDROOMS 2 & 3 SHEET E2 RECEPTACLE SPACING MUST | | | COMPLY WITH 210.52(A)(1) AND 210.52(A)(2). 2005 NEC. | | | SEE REVIEWED PLAN FOR DEFICIENCIES. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-27 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-27 |
Time |
10:01 |
Sent To |
M |
|
| Notes |
| 2009-02-27 10:02:56 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-15 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-15 |
Time |
16:01 |
Sent To |
Z |
|
| Notes |
| 2008-10-15 16:01:52 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-18 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-18 |
Time |
14:15 |
Sent To |
E |
|
| Notes |
| 2008-07-18 14:15:58 | TO "BTROBAUGH" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-10 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-10 |
Time |
12:14 |
Sent To |
Z |
|
| Notes |
| 2008-07-10 12:14:45 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-06 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-22 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2008-02-22 14:32:32 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-10-17 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-10-17 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-07-16 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-07-16 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-07-17 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2008-07-17 09:18:20 | PLEASE PROVIDE THE SPACING FOR ALL PROPOSED PLANT | | | MATERIAL. | | | | | | THE PROPOSED QUEEN PALMS IN THE REAR OF THE SITE ARE | | | SHOWN WITHIN A UTILITY EASEMENT.PLEASE OBTAIN WRITTEN | | | APPROVAL FROM THE EASEMENT HOLDER TO PLANT WITHIN THE | | | EASEMENT OR REMOVE THEM. | | | | | | YOU MUST FOLLOW THE FPL GUIDELINES FOR PLANTING TREES | | | NEAR OR UNDER POWER LINES.THIS INFORMATION CAN BE | | | OBTAINED BY GETTING ONTO THE FPL WEBSITE AND LOOK UP | | | "PLANT THE RIGHT TREE IN THE RIGHT PLACE". | | | | | | THE LAYOUT OF THE REAR PATIO SHOWN ON THE LANDSCAPE | | | PLAN IS NOT CONSISTENT WITH THE SITE PLAN.ALL PLANS | | | MUST BE CONSISTENT. | | | | | | SHOW THE CANOPY OF ALL TREES ON NEIGHBORING PROPERTIES | | | THAT ARE IN CLOSE PROXIMITY TO THIS SITE, TO AVOID | | | CONFLICTS WITH WHAT IS BEING PROPOSED. | | | | | | PROVIDE SOD AND IRRIGATION IN THE RIGHT-OF-WAY. | | | | | | PROVIDE LANDSCAPE CALCULATIONS BASED UPON SECTION | | | 94-441 OF THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (REQUIRED AND PROVIDED). | | | | | | SHOW ALL UTILITIES ON LANDSCAPE PLAN TO AVOID | | | CONFLICTS. | | | | | | | | | PLEASE CONTACT ROBERT KUSSNER AT (561) 822-1462 IF YOU | | | HAVE ANY QUESTIONS REGARDING THE LANDSCAPE COMMENTS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-03-13 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-13 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-13 |
Time |
10:37 |
Sent To |
PC |
|
| Notes |
| 2009-03-13 10:37:41 | REVISED AC-1 AND AC-2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-22 |
Time |
16:19 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-10-22 |
Time |
16:19 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-22 |
Time |
08:31 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2008-07-22 |
Time |
08:31 |
Sent To |
P |
|
| Notes |
| 2008-07-22 09:04:39 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE COOLING LOAD CALCULATIONS FOR A/C 3 ARE CALLING | | | FOR 34,067 TOTAL COOLING BTU'S, THE MECHANICAL PLAN | | | EQUIPMENT SCHEDULE FOR SYSTEM 3 SHOWS 42,000 TOTAL | | | COOLING BTU'S, THE PLANS CAN ONLY CALL FOR 15% MORE | | | TOTAL COOLING BTU'S THAN THE COOLING LOAD CALCULATIONS, | | | PER 2004 FBC 13-607.1.ABC.1.1. PLEASE CORRECT (A 3.5 | | | TON SYSTEM IS TO LARGE A 3.0 TON SYSTEM WILL MEET THE | | | COOLING LOAD REQUIREMENTS). | | | | | | 2) SEE MECHANICAL PLANS EQUIPMENT SCHEDULE. THE AIR | | | HANDLER AND CONDENSER UNIT MODEL NUMBERS ARE | | | FLIP-FLOPPED FOR ALL SYSTEMS, PLEASE CORRECT. | | | | | | 3) THE FOLLOWING SUPPLY AIR DUCTS STILL NEED TO BE | | | SIZED. A/C SYSTEM 1, MAIN TRUNK LINE OVER THE OFFICE, | | | THE FLEX DUCT AND GRILL FROM THE MAIN TRUNK LINE TO THE | | | HALL BY THE EXERCISE ROOM. A/C SYSTEM 2, THE FLEX DUCT | | | FROM THE MAIN TRUNK LINE TO THE MIXING BOX NEAR THE | | | 20X20 RETURN AIR GRILL, THE FLEX AND GRILL FROM THE | | | SAME MIXING BOX TO THE HALL. A/C SYSTEM 3, THE FLEX | | | FROM THE MAIN TRUNK LINE TO THE MIXING BOX OVER BEDROOM | | | #2, THE FLEX FROM THE MAIN TRUNK LINE TO THE MIXING BOX | | | OVER THE MASTER BEDROOM, AND THE FLEX FROM THE MAIN | | | TRUNK LINE TO THE MISSING BOX OVER THE MASTER BEDROOM | | | CLOSET. SEE YELLOW HIGH LIGHTS ON MECHANICAL PLANS, | | | PLEASE CORRECT PER 2004 WPB AMEND. 106.3.5.4 (10). | | | | | | 4) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, SEE F.B.C. 106.1.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-26 |
Time |
08:08 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-02-26 |
Time |
08:08 |
Sent To |
P |
|
| Notes |
| 2008-02-26 08:37:56 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | | | 2) PLEASE ADD AN A/C EQUIPMENT SCHEDULE TO MECHANICAL | | | PLAN, PER 2004 WPB AMEND. 106.3.5.4 (10). | | | | | | 3) SEE AIR HANDLER #1 RETURN AIR THROUGH 20X20 GRILL IN | | | DOOR, IF THE POCKET DOOR AT THE SERVICE HALL AND MAIN | | | HALL IS CLOSED THAN AIR CAN NOT RETURN TO THE AIR | | | HANDLER, PLEASE CORRECT, PER 2004 FBC/R M1602.4. | | | | | | 4) PLEASE CLARIFY ON PLAN HOW AIR IS TO RETURN TO AIR | | | HANDLER #1, SEE 2004 FBC/R M1602.4. | | | | | | 5) SEE AIR HANDLER #3 RETURN AIR DUCTS FROM BEDROOMS IS | | | NOT CONNECTED TO THE AIR HANDLER AND WILL NOT LET AIR | | | RETURN TO THE AIR HANDLER, PLEASE CORRECT. | | | | | | 6) SEE AIR HANDLER #3 IF THE 20X20 RETURN AIR GRILL IS | | | IN THE CLOSET AND THE DOOR IS CLOSED THEN AIR WILL NOT | | | RETURN TO THE AIR HANDLER, PLEASE CORRECT. | | | | | | 6) SEE YELLOW HIGH LIGHT ON MECHANICAL PLANS A/C1 AND | | | A/C2 SHOWING SUPPLY AIR DUCTS THAT NEED TO BE SIZED, | | | PER 2004 WPB AMEND. 106.3.5.4 (10). | | | | | | ** PER 2004 FBC/R M1602.4BALANCED RETURN AIR MAY BE | | | ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR | | | HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO | | | ACHIEVE PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 SQUARE INCHES (OF | | | GRILLE AREA) TO 100 CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND USING AN | | | UNRESTRICTED 1-INCH UNDERCUTTING OF DOORS TO ACHIEVE | | | PROPER RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET | | | THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR | | | EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY | | | ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-10-23 |
Time |
10:47 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2008-10-23 |
Time |
10:47 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-23 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-23 |
Time |
15:12 |
Sent To |
B |
|
| Notes |
| 2008-07-23 16:20:26 | PLUMBING PLAN REVIEW: | | | DENIED **2ND TIME: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE | | | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. WATER HEATER DETAILS; SHOW TYPE OF THERMAL | | | EXPANSION TO BE USED PER SECTION 607.3. IF A HEATER PAN | | | IS USED ON FIRST FLOOR A PAN DRAIN IS REQUIRED AND MUST | | | GO OUTSIDE BUILDING SECTION 504.7.2. | | | | | | **RESPONSE NOTED AND COMMENT WAS PARTIALLY ADDRESSED, | | | HOWEVER THE INSTALLATION OF A CHECK VALVE IS NOT | | | PROTECTION AGAINST THERMAL EXPANSION.THE INSTALLATION | | | OF AN EXPANSION TANK OR A CALIBRATED PRESSURE RELIEF | | | VALVE ARE EXAMPLES OF A MEANS FOR THERMAL EXPANSION | | | CONTROL. CLEARLY INDICATE THE LOCATION OF THE THERMAL | | | EXPANSION CONTROL DEVICE USED ON RESUBMITTED P1 & P2 | | | SHEETS. PER FBC-PLUMBING SECTION 607.3. | | | | | | 2. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE 3" TO | | | SANITARY TEE SECTION 406.3. | | | | | | **RESPONSE NOTED, HOWEVER SHEET P1 FIRST FLOOR PLAN- | | | PLUMBING IS STILL INDICATING THE WRONG BRANCH DRAIN | | | PIPE SIZE OF 2" FOR THE WASHING MACHINE. PLEASE CORRECT | | | AND CORRELATE WITH THE SANITARY RISER ON SHEET P2. PER | | | FBC- PLUMBING SECTION 406.3. | | | | | | 3. WATER RISER DIAGRAM; ONLY ON THE WATER HEATER | | | SHOWN. T &P DISCHARGE PIPE TO BE 3/4" (ON WATER | | | HEATER SHOWN) SHOCK ARRESTORS ARE NOT REQUIRED ON ALL | | | FIXTURES, SEE SECTION 604.9. | | | | | | **RESPONSE NOTED AND COMMENT WAS PARTIALLY ADDRESSED, | | | HOWEVER SHOCK ARRESTORS (WATER-HAMMER ARRESTORS) ARE | | | REQUIRED TO BE INSTALLED WHERE QUICK CLOSING VALVES ARE | | | UTILIZED. (EXAMPLES OF QUICK CLOSING VALVES ARE= | | | WASHING MACHINES, DISHWASHERS, & ICE MAKERS). CLEARLY | | | INDICATE THE REQUIRED WATER-HAMMER ARRESTORS ON BOTH | | | THE HOT/COLD WATER SUPPLY TO THE WASHING MACHINE. THE | | | RISER DIAGRAM INDICATES THE WATER-HAMMER ARRESTOR | | | MISSING FROM THE HOT WATER SUPPLY TO THE WASHING | | | MACHINE. WATER-HAMMER ARRESTOR IS ALSO REQUIRED ON THE | | | HOT WATER SUPPLY TO THE DISHWASHER. PLEASE CORRECT THIS | | | ON THE RESUBMITTAL. PER FBC- PLUMBING SECTION 604.9. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-02-26 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-02-26 |
Time |
12:48 |
Sent To |
B |
|
| Notes |
| 2008-02-26 13:21:21 | DENIED; | | | 1. WATER HEATER DETAILS; SHOW TYPE OF THERMAL EXPANION | | | TO BE USED PER FBC PLUMBING SECTION 607.3. IF A HEATER | | | PAN IS USED ON FIRST FLOOR PAN DRAIN IS REQUIRED AND | | | MUST GO TO OUT SIDE SECTION 504.7.2. | | | 2. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE 3" TO | | | SANITARY TEE SECTION 406.3. | | | 3. WATER RISER DIAGRAM; ONLY ON WATER HEATER SHOWN. T & | | | P DISCHARGE PIPE TO BE 3/4"( ON HEATER SHOWN.) SHOCK | | | ARRESTORS ARE NOT REQUIRED ON ALL FIXTURES SEE SECTION | | | 604.9 | | | PLUMBING PLAN REVIEW BY | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-10-17 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-10-17 |
Time |
12:22 |
Sent To |
I |
|
| Notes |
| 2008-10-17 14:02:14 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | ALL WALLS AND FENCES SHALL BE APPROVED ON A SEPARATE | | | PERMIT. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-07-17 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-07-17 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-07-16 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2008-07-17 09:24:31 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PROVIDE 2 COPIES OF A SIGNED AND SEALED SURVEY. | | | SURVEY SHALL BE NO MORE THAN 1 YEAR OLD. | | | | | | 2. SITE PLAN SHOWS 2 WALLS WITH GATES WITHIN THE SIDE | | | SETBACKS.PLEASE NOTE THAT ALL WALLS AND FENCES SHALL | | | BE APPROVED ON A SEPARATE PERMIT.DETAILS OF THE WALLS | | | AND GATES, TO INCLUDE THE APPROVED EASEMENT CONSENT | | | FORM FROM THE CITY OF WEST PALM BEACH WATER UTILITIES | | | DEPARTMENT, SHALL BE SUBMITTED WITH THE FENCE PERMIT | | | APPLICATION.PLEASE NOTE THAT THE OVERALL HEIGHT OF | | | THE WALLS AND GATES SHALL NOT EXCEED 6 FEET IN HEIGHT | | | MEASURED FROM THE OUTSIDE GRADE.ANY DECORATIVE | | | ELEMENTS ON TOP OF THE WALLS/GATES SHALL NOT EXCEED 10 | | | PERCENT OF 6 FEET. | | | | | | 3. THERE IS A DISCREPANCY BETWEEN THE SITE PLAN AND | | | LANDSCAPE PLAN IN REGARDS TO THE LOCATION, DIMENSIONS | | | AND AREA OF THE PATIO AT THE REAR OF THE PROPERTY. | | | PLEASE REVISE. | | | | | | 4. PLEASE ENSURE THAT ALL PLANS MATCH AND SHOW SAME | | | CONDITIONS.DISCREPANCY BETWEEN ANY OF THE PLANS WILL | | | DELAY BUILDING PERMIT APPROVAL. | | | | | | 5. IT APPEARS THAT TREES ARE BEING PROPOSED WITHIN THE | | | UTILITY EASEMENT ALONG THE REAR PROPERTY LINE.TREES | | | SHALL NOT BE LOCATED WITHIN AN EASEMENT.LANDSCAPE | | | PLAN SHALL SHOW ALL UTILITY EASEMENTS WITHIN THE | | | PROPERTY. | | | | | | 6. IRRIGATION SHALL BE APPROVED ON A SEPARATE PERMIT. | | | PROVIDE IRRIGATION PLAN AND DETAILS WITH THE IRRIGATION | | | PERMIT APPLICATION. | | | | | | 7. PAVER SHALL BE UNSEALED FOR THE DRIVEWAY TO BE A | | | PERMEABLE SURFACE. | | | | | | 8. REPEAT COMMENT - PROVIDE HEIGHT DIMENSIONS ON | | | ELEVATIONS (SHEETS A4 AND A5) FROM GRADE TO THE | | | MIDPOINT OF THE ROOF?S PITCH. | | | A. THE HEIGHT DIMENSIONS PROVIDED ARE FROM THE FIRST | | | FLOOR ELEVATION AND NOT FROM GRADE.OVERALL BUILDING | | | HEIGHT DIMENSION, AS DEFINED IN THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS), SHALL BE PROVIDED FROM | | | GRADE ON ALL ELEVATIONS. | | | | | | 9. PROVIDE HEIGHT DIMENSIONS TO THE HIGHEST POINT OF | | | THE CHIMNEY. | | | | | | 10. IDENTIFY THE OBJECT SHOWN ON THE REAR SIDE OF THE | | | PROPERTY ON THE NORTH ELEVATION. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-22 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-22 |
Time |
15:16 |
Sent To |
E |
|
| Notes |
| 2008-02-22 15:38:14 | ***FAILED*** | | | | | | | | | 1)AN APPROVED EASEMENT CONSENT FORM FROM THE CITY OF | | | WEST PALM BEACH DEPARTMENT OF PUBLIC UTILITIES (1ST | | | FLOOR CITY HALL) IS REQUIRED FOR ALL PROPOSED | | | FENCES/WALLS. | | | | | | 2)INDICATE HEIGHT DIMENSIONS OF THE PROPOSED WALL | | | WITH FENCING, DIMENSIONS SHALL BE SHOWN FROM GRADE. | | | NOTE: PURSUANT TO THE CITY OF WEST PALM BEACH ZONING | | | AND LAND DEVELOPMENT REGULATIONS, SECTION 94-302(B)(1): | | | MAXIMUM HEIGHT.IN RESIDENTIAL DISTRICTS, NO FENCE OR | | | WALL SHALL EXCEED SIX FEET IN HEIGHT WITHIN REQUIRED | | | SIDE AND REAR SETBACKS. FENCES OR WALLS SHALL NOT BE IN | | | EXCESS OF 48 INCHES IN HEIGHT WITHIN THE REQUIRED FRONT | | | SETBACK. HEDGES SHALL NOT EXCEED TEN FEET IN HEIGHT IN | | | ANY REQUIRED SETBACK. | | | | | | 3)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | | 94-305(B)(4) OF THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDRS): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | 4)BOUNDARIES OF THE REAR PATIO SHALL BE CLEARLY | | | DEFINED.THE SITE PLAN (SHEET A1) DOES NOT CLEARLY | | | SHOW THE REAR PATIO.NOTE:PATIO OR PAVED AREAS SHALL | | | DRAIN ADEQUATELY, HOWEVER, MAINTAIN ALL DRAINAGE WITHIN | | | THE PROPERTY SO-AS NOT TO DRAIN ONTO ADJACENT | | | PROPERTIES. | | | | | | 5)PLEASE SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE | | | WITH SECTION 94-442 AND 94-445 OF THE ZLDRS. | | | | | | 6)PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE | | | SURFACES LOCATED WITHIN THE FRONT YARD (FROM FRONT | | | PROPERTY LINE TO THE FRONT BUILDING FACADE).PURSUANT | | | TO SECTION 94-482 OF THE ZLDRS: REQUIRED OFF-STREET | | | PARKING SPACES FOR LESS THAN FOUR RESIDENTIAL DWELLING | | | UNITS SHALL BE LOCATED ON THE PROPERTY ON WHICH THE | | | UNITS ARE CONSTRUCTED. REQUIRED PARKING MAY BE LOCATED | | | IN A FRONT YARD; HOWEVER, THE LESSER OF 1,000 SQUARE | | | FEET OR 75 PERCENT OF THE FRONT YARD AREA MUST BE | | | LANDSCAPED. PARKING AREAS LOCATED IN THE FRONT YARD | | | SHALL BE SURFACED WITH A SMOOTH, NONDUSTING SURFACE IN | | | COMPLIANCE WITH SUBSECTION 33-485(E). IT SHALL BE A | | | VIOLATION OF THIS CHAPTER TO PARK ON ANY UNPAVED AREAS | | | AS DESCRIBED IN THIS ARTICLE.NOTE: TOTAL IMPERMEABLE | | | SURFACE WITHIN THE FRONT YARD SHALL NOT EXCEED 1,125 | | | SQ.FT.. | | | | | | 7)PROVIDE HEIGHT DIMENSIONS ON ELEVATIONS (SHEETS A4 | | | AND A5) FROM GRADE TO THE MIDPOINT OF THE ROOF'S PITCH. | | | NOTE:PURSUANT TO SECTION 94-72 OF THE ZLDRS THIS | | | DIMENSION SHALL NOT EXCEED 30 FEET. | | | | | | 8)SHEET A2, A4, AND A5 SHOW A SPA AT THE REAR.IF | | | THE SPA IS NOT TO BE INCLUDED IN THE SCOPE OF WORK | | | UNDER THIS PERMIT, IT SHALL BE DELETED FROM THE PLANS | | | OR LABELED "PERMITTED SEPARATELY."IF THE SPA IS TO BE | | | INCLUDED UNDER THIS PERMIT, A SPA DETAIL MUST BE | | | PROVIDED SHOWING THE DIMENSIONS AND HEIGHT. | | | ADDITIONALLY, SETBACK DIMENSIONS SHALL BE SHOWN FROM | | | THE PROPERTY LINES TO THE WATER'S EDGE.A FENCE | | | ENCLOSURE WILL BE REQUIRED, AND ANY SPA EQUIPMENT SHALL | | | BE SHOWN WITH SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | NOTE:PURSUANT TO SECTION 94-304 OF THE ZLDRS: SPA | | | MUST MAINTAIN A MINIMUM SETBACK OF 5 FEET TO SIDE AND | | | REAR PROPERTY LINES FROM WATER'S EDGE.SPA NOT | | | PERMITTED TO BE BUILT WITHIN THE REAR UTILITY | | | EASEMENT. | | | | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | | | | SENT TO "E" - SF RACK |
|
|