| Plan Review Stops For Permit 08020500 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-11 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-11 |
Time |
18:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-03-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-22 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-03-22 |
Time |
09:54 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-02-27 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
|
Date |
2008-02-28 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2008-02-27 14:14:45 | | | | BUILDING PLAN REVIEW | | | PERMIT: 08020500 | | | ADD: 1920 WEKIVA WAY SUITE 301 | | | CONT: PHOENIX REALTY HOMES INC. | | | TEL: (561)799-5900 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST 2-27-08 | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 4)THE BUILDING CONSTRUCTION TYPE FOR THE BASE | | | BUILDING IS TYPE V-B; HOWEVER, THE PLANS FOR THE | | | INTERIOR BUILD-OUT INDICATE THE BUILDING AS TYPE IIB ON | | | SHEET T.1. NOTE: PER FBC 602.2 ANY WOOD USED IN TYPE | | | IIB BUILDINGS SHALL BE FIRE-RETARDANT-TREATED WOOD. | | | | | | 5)SHEET A.3 DETAIL #6 THE SLAB INFILL SHALL HAVE | | | STEEL REINFORCEMENT EMBEDDED INTO THE EXISTING FLOOR TO | | | PREVENT THE INFILL CONCRETE FROM FALL OUT. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-11 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-11 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-18 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-18 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-26 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-26 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2008-02-26 08:07:42 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE PLANS DO NOT SHOW COMPLIANCE WITH NFPA-75 OR | | | NFPA-70 ARTICLE 645, FOR ROOM 111WHICH HOUSES THE I.T | | | EQUIPMENT. | | | | | | 2}METHOD ?A? ENERGY CALCULATIONS WERE SUBMITTED FOR | | | THIS PROJECT. METHOD ?A? CAN BE USED FOR ?WHOLE | | | BUILDINGS?. AS THIS IS AN ?EXISTING BUILDING ? BY | | | DEFINITION?, FORM ?A? IS NEITHER REQUIRED OR ALLOWED. | | | SEE 13-101.6. ALL THAT IS REQUIRED FOR THE ELECTRICAL | | | REVIEW IS THE BASIC PRESCRIPTIVE REQUIREMENTS. SEE | | | 13-415.2.ABC.1 PERFORMANCE CALCULATION PROCEDURES, | | | GENERAL. | | | THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR | | | A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD | | | DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE | | | METHOD DESCRIBED IN SECTION 415.2.B.1. TRADE-OFFS OF | | | INTERIOR LIGHTING POWER ALLOWANCE AMONG PORTIONS OF THE | | | BUILDING FOR WHICH A DIFFERENT METHOD OF CALCULATION | | | HAS BEEN USED ARE NOT PERMITTED. THE INSTALLED INTERIOR | | | LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | | 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH SECTION | | | 415.2.C.1 OR 415.2.B.1. THIS CAN BE DEMONSTRATED ON THE | | | PLANS INDICATED THE WATTAGES OF THE LUMINAIRES CHOSEN | | | FOR THE PROJECT CONFORM TO THE DENSITY REQUIREMENTS. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-11 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-11 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2008-04-11 16:43:50 | *****REVISION DATED 4/3/08, APPROVED***** | | | | | | REVISED PLAN SHEETS A.1, A.2, AND E.1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-02-27 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-02-27 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-10 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-10 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2008-04-10 09:50:46 | TO "BOB"#5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-14 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-14 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2008-03-14 15:42:06 | TO "BOB"#5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-02-28 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-02-21 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2008-02-21 16:57:21 | TO "BOB"#3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-25 |
Time |
11:29 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-02-25 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-18 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-18 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-02-28 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-02-28 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2008-02-28 10:18:00 | DENIED; | | | 1. BREAK SINK; IF DOORS ARE INSTALLED UNDER SINK THE | | | DOORS MUST ROLE INTO CABINET SO THEY WILL NOT BE A | | | TRIPPING PROBLEM OR INTERFER WITH APPROACH. | | | 2. PAGE P-1 WATER RISER DIAGRAM; WATER HAMMER ARRESTOR | | | REQUIRED FOR ICE LINE,SPECOUT TYPE AND SIZE ON PLAN AND | | | SHOW ON DIAGRAM. SEE FBCPLUMBING SECTION 604.9. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-25 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-25 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2008-02-25 08:58:25 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|