| Plan Review Stops For Permit 08020399 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-12-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-01 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-01 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2008-12-01 10:15:02 | REVISION #10 & 11 | | | A0.2, A0.2, A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2008-12-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-01 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-01 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2008-12-01 10:14:07 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. A LETTER REGARDING INSPECTIONS WAS INCLUDED WITH THE | | | REVISION. THE LETTER WAS NOT SEALED AND DATED BY THE | | | ENGINEER, AND IT IS NOT CLEAR WHY IT WAS INCLUDED WITH | | | THIS REVISION AS INSPECTIONS ARE USUALLY HANDLED BY THE | | | INSPECTORS (NOT PLAN REVIEW). PLEASE COORDINATE WITH | | | THE BUILDING INSPECTOR OR CLARIFY PURPOSE OF THE | | | LETTER. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-11 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-11 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-01 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-01 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2008-07-01 16:02:26 | APPLICATION SUBMITTED AT FRONT COUNTER | | | | | | BUILDING REVIEW PASSED; HOWEVER, AS ELECTRIC FAILED, A | | | NEW BUILDING REVIEW WILL BE REQUIRED WHEN NEW ENERGY | | | CALCS ARE SUBMITTED ADDRESSING ELECTRIC COMMENTS. | | 2008-07-01 09:34:29 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.A PERMIT APPLICATION IS REQUIRED.THE OLD SHEETS | | | AND PERMIT APPLICATION WERE NOT SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-02 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-02 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2008-06-02 11:18:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.SEE A1, CONDITION TYPE P8, STATES PLYWOOD TO 8' IN | | | ELECTRIC ROOM, WHICH IS IN CONFLICT WITH A9, PARTITION | | | TYPE 3A AND 3B.PLEASE CORRELATE. | | | | | | 2.THE MEP SHEETS STILL SHOW THE COMPANY NAME OF | | | STEVEN L COHEN & ASSOCIATES PA.THIS NAME IS ALSO | | | INCLUDED ON THE COVER SHEET.PLEASE INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION FS481 OR REMOVE THE NAME | | | AS DISCUSSED. | | | | | | 3.SEE THE PREVIOUS LIST IN REGARDS TO ENERGY CALCS. | | | THE PREVIOUS LIST STATED THAT THE HOT WATER HEATER WAS | | | NOT INCLUDED IN THE INPUT DATA REPORT; THIS DOES NOT | | | APPEAR ON THE NEW ENERGY CALCS.PLEASE CONFIRM THAT | | | ALL BUILDING COMPONENTS ARE INCLUDED AND CORRELATE WITH | | | THE PLANS. | | | | | | 4.PLEASE SIGN THE OWNER/AGENT LINE OF THE ENERGY | | | CALCS. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-09 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-09 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2008-04-09 11:48:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1. CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE | | | ARCHITECTURE THROUGH A COMPANY, FS481.219(2). | | | APPLICATION IS IN PROGRESS; THIS MUST BE APPROVED AND | | | THE CERTIFICATE OF AUTHORIZATION NUMBER PRINTED ON EACH | | | SHEET PRIOR TO PERMIT ISSUANCE FAC61G1-16.004. | | | | | | 2. THE VALUE HAS BEEN ADJUSTED.ALSO NOTE THAT THE | | | VALUE OF THE SHELL BUILDING HAS BEEN ADJUSTED BASED ON | | | ICC VALUATION TABLES, SEE ATTACHED.ADDITIONAL FEES | | | ARE REQUIRED FOR BOTH THE SHELL BUILDING AND THIS | | | PERMIT; PLEASE PAY IMMEDIATELY.NOTE THAT INSPECTIONS | | | CANNOT BE SCHEDULED FOR THE ISSUED PERMIT UNTIL FEES | | | ARE PAID.THE VALUATION DECLARED BY ORIGINAL | | | CONTRACTOR WAS TOO LOW. | | | | | | 3. A1, NOTE N1, NOTE IS INCOMPLETE. | | | | | | 4. A1, CONDITION TYPES, STATES THAT PLYWOOD WILL BE | | | INSTALLED 6IN ABOVE THE CEILING.SEE FBC603, | | | COMBUSTIBLES NOT PERMITTED IN TYPE I AND II BUILDINGS. | | | THIS DOES NOT APPEAR TO FALL UNDER ANY OF THE | | | EXEMPTIONS. | | | | | | 5. EXISTING ENTRY RAMP, SPECIFY SLOPE, FBC11-4.3. | | | | | | 6. ELEVATION 5 A6 WATER FOUNTAIN CONFLICTS WITH 3A17 | | | AND FLOOR PLAN. | | | | | | 7. 8 17, URINAL, SEE FBC11-4.18.2, SHOULD BE 17INCHES. | | | SEE PLUMBING COMMENTS. | | | | | | 8. THE SHELL BUILDING HAS NOT ACHIEVED A CERTIFICATE OF | | | COMPLETION; THE CONTRACTOR FOR THIS TENANT SPACE IS | | | DIFFERENT FROM THE BASE BUILDING AND WILL REQUIRE A | | | LETTER FROM THE BASE BUILDING CONTRACTOR ALLOWING THE | | | TENANT BUILDOUT CONTRACTOR TO START WORK ON THIS TENANT | | | SPACE BEFORE THE C OF C FOR THE BASE BUILDING HAS BEEN | | | ISSUED.THE DEVELOPER AND BOTH CONTRACTORS WILL BE | | | REQUIRED TO SUBMIT A LETTER STATING THAT THEY | | | UNDERSTAND THAT ANY DISPUTE OVER RESPONSIBILITY DOES | | | NOT RELIEVE THEM FROM THE JOINT RESPONSIBILITY TO | | | COMPLY WITH THE BUILDING CODE. | | | | | | 9. FIRE SPRINKLER PLANS REQUIRED IF SPRINKLERS ARE | | | REQUIRED FOR CODE COMPLIANCE, FBC*106.3.5.1.1(5), | | | FS553.79 (2).PLEASE ADVISE IF A FIRE SPRINKLER PERMIT | | | HAS ALREADY BEEN ISSUED. | | | | | | 10. DECLARE MAXIMUM RACK HEIGHT ON THE PLAN. | | | | | | 11.SEE ELECTRIC COMMENTS REGARDING ENERGY CALC | | | VERSION.PLEASE CONFIRM ALL BUILDING COMPONENTS SUCH | | | AS WINDOWS, DOORS, HOT WATER HEATER, INSULATION, ETC. | | | FOR INSTANCE, NO HOT WATER HEATER IS SHOWN AND GLASS | | | STOREFRONT IS NOT REFLECTED IN THE ENERGY CALC DOOR AND | | | WINDOW DATA.THIS IS A STATUTORY AND FLORIDA BUILDING | | | CODE REQUIREMENT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-24 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-24 |
Time |
11:21 |
Sent To |
PC |
|
| Notes |
| 2008-12-24 11:21:52 | REV, E1, 7 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2008-12-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-09 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-09 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2008-12-09 13:27:40 | | | | ** DENIED REVISION ** | | | | | | 1) NOTE: PLEASE REVISE ALL CIRCUITING ON PLANS WHICH | | | WILL CORRELATE WITH THE SUBMITTED PANEL SCHEDULES. THE | | | USE OF GENERAL RECEPTACLES OR GENERAL LIGHTING IS NOT | | | ACCEPTABLE. PLEASE SEE 408.4 WHICH STATES ALL | | | CIRCUITING SHALL BE SPECIFIC TO ROOMS AND AREAS IN | | | WHICH THEY FEED. | | | PLEASE ALSO SEE ITEMS SUCH AS ROOF-TOP GFI FOR A/C | | | EQUIPMENT.210.63 THE FOLLOWING IS BASED ON COMMENTARY | | | TAKEN DIRECTLY FROM THE NEC HANDBOOK IN SECTION 408.4. | | | **SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO | | | REQUIRE THAT THE IDENTIFICATION FOR EVERY CIRCUIT | | | SUPPLIED BY A PANELBOARD OR SWITCHBOARD BE LEGIBLE AND | | | CLEARLY STATE THE SPECIFIC PURPOSE FOR WHICH THE | | | CIRCUIT IS USED. CIRCUITS USED FOR THE SAME PURPOSE | | | MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR EXAMPLE, | | | SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY OUTLETS IN | | | THE KITCHEN, DINING ROOM, AND KITCHEN COUNTERTOPS. | | | IDENTIFYING THE CIRCUITS AS SMALL APPLIANCE BRANCH | | | CIRCUITS IS NOT ACCEPTABLE; INSTEAD, THEY SHOULD BE | | | IDENTIFIED AS ``KITCHEN WALL RECEPTACLES,'' ``DINING | | | ROOM FLOOR RECEPTACLE,'' OR ``KITCHEN COUNTERTOP | | | RECEPTACLES LEFT OF SINK.'' CIRCUIT DIRECTORIES | | | CONTAINING MULTIPLE ENTRIES WITH ONLY ``LIGHTS'' OR | | | ``OUTLETS'' DO NOT PROVIDE THE SUFFICIENT DETAIL | | | REQUIRED BY THIS SECTION.** | | | | | | | | | 2) NOTE: PLEASE SEE 13-415.2,13-415.2.ABC.1.1,.1.2. | | | PLEASE REVISE LIGHTING PERFORMANCE CALCULATIONS FOR | | | ITEMS REVISED ON PLANS. | | | PLEASE SEE AREAS SUCH AS STORAGE WHICH INDICATES AN | | | ALLOWANCE GREATER THAN THE ALLOWANCES LISTED ON TABLE | | | 13-415.2.B. | | | | | | | | | | | | | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-03 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-03 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2008-07-03 09:52:23 | NO GROSS ERRORS ON ELECTRICAL PART OF THE ENERGY | | | CALCULATIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-01 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-01 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2008-07-01 14:19:26 | ** TEMPORARY DENIED REVIEW ** | | | | | | 1) NOTE: THE SUBMITTED ENERGY CALCULATIONS FOR BUILD | | | OUT ARE SHOWING LIGHTING WHICH IS PART OF THE SHELL. | | | ONLY THE LIGHTING FROM THE BUILD OUT SERVICE IS TO BE | | | ON THE INPUT DATA REPORT. | | | CALLED THE ENGINEER TWICE FOR ELECTRICAL AS WELL AS | | | MECHANICAL AND THEY WILL SEND REVISED SIGNED, DATED AND | | | SEALED CALCULATIONS. WENT OVER THE FACT OF REVISED | | | CALCULATIONS FOR EXTERIOR LIGHTS WHICH ARE SHOWN ON | | | STAPLES BUILD OUT INPUT DATA REPORT ARE NOT ACCURATE | | | AND IS STRONGLY SUGGESTED THESE BE GONE OVER BEFORE | | | SENDING REVISED TO THIS OFFICE. | | | | | | 2) NOTE: ORIGINAL PERMIT APPLICATION NOT IN PACKAGE. | | | NEED APPLICATION. CALLED AND LEFT ON MESSAGE ON | | | CONTRACTOR'S CELL PHONE VOICE MAIL. | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-29 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2008-05-29 09:15:12 | ** DENIED 2ND REVIEW ** | | | | | | ** SECOND REVIEW UNDER NEW PERMIT APPLICATION. | | | | | | ** PLEASE SEE SOME OF THE NOTES FROM THE PREVIOUS | | | REVIEW ARE STILL IN NEED OF ADDRESSING. PLEASE SEE SOME | | | NEW COMMENTS BASED ON REVISED PLANS, REVISED SCOPE OF | | | WORK AT LOCATION. | | | | | | 1) NOTE: PLEASE KNOW AS STATED ON PREVIOUS ELECTRICAL | | | REVIEW THE BASE BUILDING/SHELL PLANS HAVE NOT BEEN | | | ISSUED FOR PERMITTING OF BASE BUILDINGS ELECTRICAL | | | SYSTEMS. THIS MAY AFFECT THE BUILD OUT PLANS FOR | | | ELECTRICAL DESIGNATIONS OF EQUIPMENT ETC. | | | PLEASE BE SURE ALL COORDINATION IS ADDRESSED BETWEEN | | | PERMITS. ANY REVISIONS MADE TO BASE BUILDING NEED TO BE | | | COORDINATED WITH BUILD OUT PLANS AND VICE-VERSA. | | | FBC 106.1.2 | | | | | | 2) NOTE: PLEASE SEE THE VALUE FOR THE COMPLETE SCOPE OF | | | WORK FOR BUILD OUT HAS STILL NOT BEEN ADJUSTED. THIS | | | SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, DESIGN | | | COSTS ETC EVEN IF ANY OF THESE ITEMS ARE OWNER | | | SUPPLIED. THIS SHALL INCLUDE LIGHTING, LIGHTING | | | SYSTEMS, EQUIPMENT ETC. | | | FBC 108.3 | | | | | | 3) NOTE: PLEASE SEE FBC CHAPTER 13, 13-415.2.ABC.1.1, | | | .1.2, .1.3 AND 13-415.2. | | | AS STATED ON ALL PREVIOUS REVIEWS, PLEASER BE SURE | | | *ALL* INFORMATION ON PLANS WITH RESPECT TO LIGHTING AND | | | ALL OTHER BUILDING COMPONENTS COORDINATES WITH THE | | | INPUT DATA REPORT/ SUMMARY SHEETS OF THE SUBMITTED | | | ENERGY CALCULATIONS. THE INPUT DATA REPORT WILL BE | | | NOTED AS IDR FOR THE REMAINDER OF THIS COMMENT. | | | THE INFORMATION ON THE IDR STILL DOES CORRELATE WITH | | | PLANS. THERE WILL BE SOME EXAMPLES GIVEN BELOW. HOWEVER | | | THESE ARE ONLY SOME EXAMPLES. THIS IS NOT AN | | | EXHAUSTIVE/EXHAUSTED LIST. | | | FOR EXAMPLE: | | | PLEASE SEE THE INTERIOR LIGHTS FOR SPACES CALLED OUT AS | | | UTILITY ROOMS. IT SEEMS ALL THREE OF THESE ROOMS ARE | | | BEING LUMPED INTO ONE SPACE DESIGNATION WHICH IS OK TO | | | DO. HOWEVER HOW IS THIS POSSIBLE WHEN ALL THREE | | | FIXTURES ARE DIFFERENT AND CONTAIN DIFFERENT WATTAGES? | | | PLEASE SEPARATE SPACES IF ALL FIXTURES ARE NOT GOING TO | | | BE THE SAME. | | | METHOD B, PER TABLE 13-415.2.B SPACE BY SPACE IS TO BE | | | SHOWN AS SPACE BY SPACE. | | | FOR EXAMPLE: | | | PLEASE EXPLAIN WHERE SOME FIXTURES ON PLANS ARE LOCATED | | | IN THE IDR. ONE FIXTURE IS THE DOCK LIGHT WHICH IS A | | | 90W FIXTURE. THERE ARE NO 90W FIXTURES SHOWN ON THE | | | IDR. | | | FOR EXAMPLE: | | | PLEASE SEE ROOMS 105/107 WHICH ARE SEPARATE ROOMS. BOTH | | | OF THESE ROOMS AND FIXTURES ARE LISTED ON THE IDR IN | | | ONE SPACE. | | | FOR EXAMPLE: | | | PLEASE SEE THE RETAIL SALES AREA. PLEASE SEE THE COUNT | | | OF THE FIXTURES LISTED AS *B* ARE LOWER ON THE IDR THAN | | | THE NUMBER OF FIXTURES ON PLANS. | | | FOR EXAMPLE: | | | PLEASE SEE EXTERIOR LIGHTS AS THE *J* FIXTURES AS | | | LISTED ON THE FIXTURE LEGEND AND ON PLANS DOES NOT | | | APPEAR IN THE IDR AT ALL. IN FACT THERE ARE NO 175W | | | FIXTURES. | | | FOR EXAMPLE: | | | PLEASE EXPLAIN THE ELECTRICAL SYMBOL LEGEND ON SHEET | | | E-8 WHICH CONTAINS DIFFERENT FIXTURES AND DESIGNATIONS | | | THAN THAT OF THE FIXTURES ON THE SAME PAGE ON LIGHTING | | | LEGEND. | | | FOR EXAMPLE: | | | PLEASE SEE THE IDR WHICH DOES NOT CONTAIN ANY | | | ELECTRICAL WATER HEATER YET THE PLANS MOST CERTAINLY | | | DOES SHOW A WATER HEATER. THE IDR IS ACTUALLY *BLANK* | | | FOR THE SECTIONS FOR WATER HEATERS. | | | ** IMPORTANT, PLEASE BE SURE TO SEE ALL OTHER BUILDING | | | COMPONENTS. THIS OFFICE CAN NOT EMPHASIZE ENOUGH TO | | | PLEASE BE SURE TO CORRELATE ALL ITEMS ON PLANS WITH | | | THAT OF THE IDR. | | | PLEASE SEE 13-415.2, 13-415.2.ABC.1.1 AND .1.2 FOR | | | INTERIOR AND PLEASE SEE 13-415.2.ABC.1.3 FOR EXTERIOR. | | | | | | 4) NOTE: PLEASE SEE SHEET E-4 WHICH STATES THE NEW OVER | | | HEAD FEEDERS WILL BE GOING TO A MAIN ELECTRICAL ROOM. | | | PLEASE ADJUST AND COORDINATE PLANS AS THE MAIN | | | ELECTRICAL ROOM WHICH USED TO BE ON THE BASE BUILDING | | | IS NO LONGER PART OF THE BASE BUILDING DESIGN. | | | FBC 106.1.2 FOR COORDINATION. | | | | | | 5) NOTE: PLEASE SEE NOTICE TO FS 553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS FOR CODE COMPLIANCE IS BEING | | | GIVEN AT THIS TIME. THIS IS ONLY A NOTICE. | | | | | | 6) NOTE: PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS DOWN | | | THE LEFT HAND SIDE OF PLANS. THESE SHOULD BE PLACED IN | | | BINDER(S)/ FOLDERS IN A NEAT AND ORDERLY FASHION. | | | AS STATED ON PREVIOUS REVIEW: PLEASE BE SURE TO REMOVE | | | ALL DOCUMENTS FROM PREVIOUS EXPIRED PERMIT APPLICATION. | | | | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-07 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-06 |
Time |
17:56 |
Sent To |
|
|
| Notes |
| 2008-03-08 11:43:28 | ** NOTE ADDED** | | | | | | 1) NOTE: PLEASE VERIFY ALL PANELS WHICH ARE SHWON AS | | | FEED-THRU LUGS. SOME PANELS ARE SHOWN AS FEED-THRU YET | | | THERE ARE OCP DEVICES IN THOSE SAME PANELS FOR SUB | | | PANELS. (P4) | | 2008-03-07 11:35:28 | ** DENIED REVIEW ** | | | | | | *** FIRST REVIEW UNDER NEW APPLIED PERMIT. | | | | | | 2029 OKEECHOBEE BLVD. | | | | | | ** PLEASE KNOW A FULL AND COMPLETE REVIEW FOR MINIMUM | | | CODE COMPLIANCE CAN NOT BE DONE AT THIS TIME AS THERE | | | ARE SEVERAL ITEMS STILL NEEDED TO BE COORDINATED WITH | | | THE BASE BUILDING. | | | | | | | | | | | | 1) NOTE: PLEASE KNOW AT THIS TIME NO PERMIT, PLANS ETC | | | HAVE BEEN APPLIED FOR ANY ELECTRICAL SYSTEMS OR OTHER | | | TRADES FOR ACTUAL SHELL. THE ONLY PERMIT APPLIED FOR | | | AND ISSUED IS FOR STRUCTURAL OF SHELL ONLY AND NO OTHER | | | WORK. NO WALLS, NO ELECTRICAL, NO PLUMBING ETC. THE | | | SHELL OWNER AND CONTRACTOR HAVE BEEN NOTIFIED TO SUBMIT | | | FOR PERMIT AND COMPLETE PLANS FOR SHELL. | | | AS MANY ITEMS ON THESE PLANS ARE SHOWN AS EXISTING, | | | THIS IS MOST DEFINITELY NOT THE CASE. | | | NO BUILD OUT PLANS WILL BE ISSUED UNTIL BASE SHELL | | | BUILDING PLANS AND PERMIT APPLICATION HAVE BEEN | | | COMPLETED, SUBMITTED AND ISSUED FOR PERMIT. | | | ** THIS WILL AFFECT OTHER ITEMS ON REVIEWS BELOW. | | | | | | 2) NOTE: PLEASE SEE THESE PLANS ARE NOW BEING SUBMITTED | | | UNDER COMPLETELY NEW PERMIT. MANY DOCUMENTS AND SHEETS | | | IN PACKAGE STILL REFLECT PREVIOUS EXPIRED PERMIT. | | | PLEASE ONLY SUBMIT RELEVANT DOCUMENTS FOR NEW PERMIT | | | APPLICATION BEING MADE. PLEASE KNOW THAT SOMECOMMENTS | | | FROM THE THREE PREVIOUS REVIEWS UNDER EXPIRED PERMIT | | | ARE STILL ALSO IN NEED OF ADDRESSING AND HAVE BEEN | | | REPEATED IN THIS REVIEW. PLEASE SEE FLORIDA STATUTES | | | 553.80(2)(B) WAS GIVEN ON TWO PREVIOUS REVIEWS WITH | | | RESPECT TO REPEAT COMMENTS FOR MINIMUM CODE COMPLIANCE. | | | THE RESPONSE LETTER MENTIONS TO BE HANDLED BY THE | | | OWNER/CONTRACTOR. THIS IS THE SOLE RESPONSIBILITY OF | | | THE DESIGNER AND NOT AN OWNER OR CONTRACTOR. THE | | | FLORIDA STATUTE AND FINE GIVEN WAS TO THE DESIGNER AS | | | REQUIRED UNDER THE STATUTE GIVEN AND IS NOT THAT FOR | | | ANY OTHER INDIVIDUAL. | | | IT IS IMPERATIVE THAT THE MINIMUM CODE COMPLIANCE | | | COMMENTS ARE ADDRESSED FOR REVIEWS. | | | | | | 3) NOTE: PLEASE SEE THE APPLIED VALUE FOR SCOPE OF WORK | | | IS LOW. THE VALUE SHALL INCLUDE ALL LABOR, MATERIALS, | | | EQUIPMENT, DESIGN COST ETC. FBC 108.3 | | | THIS INCLUDES ALL ELECTRICAL, LIGHTING FIXTURES, | | | SERVICE EQUIPMENT ETC EVEN IF ANY OF THE ABOVE ITEMS | | | ARE OWNER SUPPLIED. | | | | | | 4) NOTE: PLEASE SEE THE ELECTRICAL SERVICE DOES NOT | | | MATCH WITH ANY PLANS FOR BASE BUILDING IN PART OF THE | | | FACT THAT NO PLANS HAVE BEEN SUBMITTED. | | | PLEASE ALSO SEE THE SHEET E-7 SHOWS AN MSB PANEL WHICH | | | SHOWS EACH TENANT BAY BEING FED FROM THIS MSB YET THE | | | SAME SHEET SHOWS THIS TENANT FED FROM GUTTER AND ALSO | | | FROM A SEPARATE RISER. | | | PLEASE CORRELATE ALL SERVICE EQUIPMENT ONCE PLANS FOR | | | BASE BUILDING ARE COMPLETED. | | | 230.70,230.71,230.72, 230.76, 230.79 ETC | | | | | | 5) NOTE: PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED | | | DO NOT MEET THE MINIMUM REQUIREMENTS OF CHAPTER 13. | | | PLEASE SEE THE CALCULATIONS SUBMITTED ARE METHOD *A* | | | WHICH IS FOR WHOLE BUILDING. HOW IS THIS POSSIBLE WHEN | | | THIS IS FOR A TENANT BUILD OUT? | | | PLEASE SEE THE CALCULATIONS SUBMITTED IS NOT THE LATEST | | | VERSION ADOPTED BY THE FBC 2004W /2007 SUPPLEMENTS. THE | | | LATEST VERSION SHALL BE 2.5. (2.11 SUBMITTED) | | | PLEASE SEE BLUE SHEETS UNDER THE ADOPTED CHANGES DATED | | | DECEMBER 8TH, 2006. | | | PLEASE SEE THE INPUT DATA REPORT WHICH WILL BE NOTED AS | | | THE IDR ON HERE OUT DOES NOT CORRELATE WITH THE PLANS. | | | FOR EXAMPLE: | | | SEE ADDRESS ON CALCULATIONS SHOWS 2015 OKEECHOBEE BLVD | | | WHEN APPLIED LOCATION IS 2015 OKEECHOBEE BLVD. | | | THE INTERIOR LIGHTING CONTROLS FOR ALL AREAS ARE NOTED | | | AS *MANUAL ON/OFF*. HOW IS THIS POSSIBLE WHEN THE | | | LIGHTING IS AUTOMATICALLY CONTROLLED? | | | THE EXTERIOR LIGHTING ON THE IDR SHOWS ABSOLUTELY NOT | | | FIXTURES FOR EXTERIOR OF BUILDING. HOW IS THIS POSSIBLE | | | WHEN THE PLANS CLEARLY SHOW LIGHTS? | | | PLEASE SEE THE INTERIOR LIGHTING FIXTURES FOR ALL | | | NUMBERS OF FIXTURES, TYPE OF FIXTURES AND WATTAGES NEED | | | TO CORRELATE. | | | 13-400.3, 13-415.2, 13-415.2.ABC.1.1, .1.2, .1.3 | | | | | | 6) NOTE: PLEASE SUBMIT COMPLETED INFORMATION FOR THE | | | REQUIRED AND PROPOSED LIGHTING CONTROL SYSTEM PER | | | 13-415.1.ABC.1.1, .1.2 ,.1.3 AND .1.4. | | | RESPONSE MENTIONS THERE WILL BE A PANEL AND SOME | | | DEVICES ARE SHOWN AND NOTED ON PLANS, HOWEVER NOT ALL | | | INFORMATION AS REQUESTED ON THE PREVIOUS THREE REVIEWS | | | UNDER EXPIRED PERMIT WAS SUBMITTED. | | | SHOW COMPLETE SYSTEM | | | SHOW ALL OVER RIDE LOCATIONS. | | | SHOW ZONES, | | | SHOW ALL LOCATIONS FOR SEPARATE CONTROLS. THERE ARE | | | STILL LOCATIONS ON PLANS IN WHICH NO SEPARATE SPACE | | | CONTROLS ARE PROVIDED. (WOULD GIVE ROOM OR AREA | | | LOCATIONS HOWEVER E-5 DOES NOT SHOW ANY DESIGNATIONS.) | | | SHOW SCHEDULING. | | | ETC. | | | THE RESPONSE MENTIONS THE SYSTEM WILL MEET THE FBC | | | HOWEVER MAY NOT QUOTE CODE IN LIEU OF SHOWING MINIMUM | | | DETAILS. | | | WHERE ARE CONTROLS FOR OUTSIDE LIGHTING MEETING SECTION | | | NOTED ABOVE? TIME CLOCK? BATTERY BACK UP FOR TIME | | | CLOCK?(MIN 10HRS)OR WILL ALL BE PHOTO-SENSOR? | | | | | | 7) NOTE: PLEASE SEE THE PLANS NEED TO CONTAIN NOTES FOR | | | CONSTRUCTION DOCUMENTS AS STATED IN 13-413.1.ABC.2.1, | | | .2.2. | | | PLEASE PLACE REQUIRED NOTES ON PLANS. | | | | | | 8) NOTE: PLEASE INCLUDE AND SHOW ALL ROOM AND AREA | | | DESIGNATIONS ON PLANS. | | | FBC 106.1.2 | | | | | | 9) NOTE: PLEASE SEE PANEL P1 IS STILL BEING SHOWN ON | | | RISER WITH A 150MCB AND ON PANEL SCHEDULE AS 100 MCB. | | | THIS WAS NOTED ON PREVIOUS REVIEWS | | | | | | 10) NOTE: PLEASE BE SURE TO LIST THE FOLLOWING CODES ON | | | ELECTRICAL PLANS. | | | 2004 FBC W/2007 REVISIONS. | | | 2005 NFPA- 70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 (WHERE APPLICABLE) | | | | | | | | | ** PLEASE KNOW AS THERE ARE SEVERAL ITEMS NOT YET | | | SUBMITTED AND INCLUDED ON PLANS THERE MAY VERY WELL BE | | | NEW COMMENTS ON THE FOLLOWING REVIEW WHICH CAN NOT BE | | | MADE AT THIS TIME. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | 2008-03-06 17:56:48 | 2008-03-06 17:56:48 | | | | | | IN ELEC FOR REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-12-10 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-12-10 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2008-12-10 13:12:54 | *****REVISION APPROVED***** | | | | | | | | | REVISED PLAN SHEETS A0.2, A1, A4, A10, AND FS-1 WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-07-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-02 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-02 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2008-07-02 11:00:09 | STAMPED FS-1 AND FS-2 SEPARATE SHOP DRAWINGS AND PERMIT | | | REQUIRED FOR FIRE SPRINKLER REMODEL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-04 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-04 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2008-06-04 14:40:40 | PLANS STAMPED SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER AND FIRE ALARM SYSTEMS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-03-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-24 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-24 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2008-03-24 15:44:54 | *****UNSAT***** | | | | | | | | | 1.STAPLES IS LISTED AS BAY 2;SINCE THERE ARE NO | | | OTHER BAYS FOR 2029 OKEECHOBEE BOULEVARD, ELIMINATE | | | REFERENCE TO BAY 2 ON DRAWINGS A0.1 THRU A10.THE USE | | | OF SUITES/TENANTS/BAYS SHOULD ONLY BE USED WHEN THERE | | | ARE MORE THAN ONE UNIT WITH THE SAME NUMERICAL ADDRESS. | | | | | | | | | 2.SPECIFY THE INTERIOR FLOOR FINISH IN TERMS OF CLASS | | | I OF CLASS II. | | | | | | 3.CODE ANALYSIS, ON DRAWING A0.1, STATES THAT THIS | | | CLASS B MERCANTILE OCCUPANCY WILL HAVE A FULL FIRE | | | ALARM SYSTEM. PROVIDE A LAYOUT OF THE FIRE ALARM | | | DEVICES AT THIS SITE. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET | | | EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-14 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-14 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2008-11-25 11:05:36 | 11/25/08--PLANS WERE ON HOLD. REVIEWS STARTED BACK UP | | | TODAY. | | 2008-11-14 14:15:00 | TO "COMM" BD#28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-17 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-17 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2008-10-21 10:09:28 | TO "COMM" BD#7 | | 2008-10-17 15:54:50 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-10 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-10 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2008-06-10 16:19:32 | TO "COMM" BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-12 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2008-05-12 11:21:56 | TO "COMM" BD#32--PLANS ON RACK/LARGE FOLDED PLANS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-09 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-02-20 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2008-02-20 09:19:57 | TO "COMM" BD#62 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
N |
Date |
2008-12-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-06 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-06 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2008-12-06 10:49:46 | REVISED AC-1 AND AC-2 PREVIOUSLY PASSED BY TG ON | | | 10/24/08 FILED WITH PERMIT SET. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-24 |
Time |
12:00 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-10-24 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2008-10-24 12:01:45 | REVISION TO PLAN AC-1 AND AC-2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-11 |
Time |
09:05 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-06-11 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-27 |
Time |
08:48 |
Rev Time |
1.20 |
| Received By |
tgordon |
Date |
2008-05-27 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2008-05-27 08:49:37 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-103.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-05 |
Time |
14:31 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-03-05 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2008-03-05 14:45:54 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS SUBMITTED ARE THE WRONG VERSION, | | | THEY NEED TO BE THE 2.5 VERSION, PER 2004 FBC | | | 13-400.3.A. AN ACCURATELY COMPLETED FORM 400A-04R | | | (GENERATED BY THE FLA/COM-2004 COMPUTER PROGRAM, | | | VERSION 2.5) DEMONSTRATING THAT CODE COMPLIANCE HAS | | | BEEN ACHIEVED SHALL BE SUBMITTED TO THE BUILDING | | | OFFICIAL FOR METHOD A COMPLIANCE. CALCULATIONS SHALL BE | | | PERFORMED FOR THE CLIMATE ZONE IN WHICH THE BUILDING | | | WILL BE LOCATED AND ACCORDING TO THE PROCEDURES | | | SPECIFIED FOR METHOD A IN THIS SUB-CHAPTER | | | | | | 2)A/C SYSTEM LISTED ON A/C EQUIPMENT SCHEDULE COULD | | | NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE, PLEASE | | | CORRECT THE MODEL NUMBERS OR SUBMIT AN ARI CERTIFICATE, | | | SEE 2004 FBC 13-407.1.ABC.3.1.1. | | | | | | 3)A/C SYSTEM #5 RTU-5 LISTED ON A/C EQUIPMENT | | | SCHEDULE SHOWS 10 SEER PER 2004 FBC ENERGY EFFICIENCY | | | CHAPTER 13 TABLE 13-407.1.ABC.3.2A THE MINIMUM SEER FOR | | | THIS SIZE SYSTEM IS 13, PLEASE CORRECT. | | | | | | 4) UNITS RTU1 TO 4 REQUIRE SMOKE DETECTORS, PER 2004 | | | FBC/M 606.2.1. PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-12-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-11 |
Time |
10:58 |
Rev Time |
|
| Received By |
kstevens |
Date |
2008-11-03 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2008-12-11 11:16:01 | REVISIONS OK -- SHTS P-1 & P-2 APPROVED 11-3-08 BUT | | | WAITING FOR REVISION FEES TO BE PAID PRIOR TO PASSING | | | IN COMPUTER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-06-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-26 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-26 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2008-06-26 08:16:47 | ****************PROVISO**************** | | | A} SHEET P-2 WATER RISER DIAGRAM: A SHUT OFF VALVE IS | | | REQUIRED FOR EACH SILLCOCK (HOSE BIBB). PER FBC-2004 | | | PLUMBING SECTION 606.2(2). (REVISION REQUIRED) | | | | | | B} SHEET P-2 ELECTRIC WATER HEATER DETAIL: THE RELIEF | | | VALVE DISCHARGE SHALL BE PER FBC-2004 PLUMBING SECTION | | | 504.6.1 AND THE WATER HEATER PAN DRAIN TERMINATION | | | SHALL BE PER FBC-2004 PLUMBING SECTION 504.7.2. | | | (REVISION REQUIRED) | | | | | | C} SHEET P-2 WATER RISER DIAGRAM: AIR CHAMBERS ARE NOT | | | APPROVED, WATER-HAMMER ARRESTORS AS PER FBC- PLUMBING | | | SECTION 604.9 ARE APPROVED AS NOTED ON BOTTOM OF SHEET | | | P-2. (REVISION REQUIRED) | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: MPERSON@WPB. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-05 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-05 |
Time |
13:53 |
Sent To |
PC |
|
| Notes |
| 2008-06-05 13:59:51 | ****************PROVISO**************** | | | A} A SHUT OFF VALVE IS REQUIRED FOR EACH SILLCOCK | | | (HOSE BIBB). PER FBC-2004 PLUMBING SECTION 606.2(2). | | | | | | B} THE RELIEF VALVE DISCHARGE SHALL BE PER FBC-2004 | | | PLUMBING SECTION 504.6.1 AND THE WATER HEATER PAN DRAIN | | | TERMINATION SHALL BE PER FBC-2004 PLUMBING SECTION | | | 504.7.2. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-20 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-20 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2008-03-20 11:07:23 | PLUMBING PLAN REVIEW: | | | DENIED | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET A0.1 CODE ANALYSIS IS INDICATING THE WRONG | | | CODE CYCLE AS FBC-2004 W/06 REVISIONS. THE REVISIONS | | | SHOULD BE 2007. | | | | | | 2. SHEET A7 DETAIL 2, CLEARLY INDICATE THE REQUIRED | | | CLEAR FLOOR SPACE FOR THE LAVATORIES (30" X 48" AND | | | MAXIMUM 19" UNDER LAV.) IN THE MENS AND WOMENS HANDICAP | | | STALLS. PER FBC CHAPTER 11, SECTION 11-4.19.3. NOTE: | | | THE DOOR SWING CAN NOT BE IN THE CLEAR FLOOR SPACE. PER | | | FBC CHAPTER 11, SECTION 11-4.22.2. | | | | | | 3. SHEET A7 DETAIL 8, THE URINAL ELEVATION FOR THE | | | MAXIMUM DISTANCE FOR THE URINAL RIM FROM FINNISH FLOOR | | | IS BEING INDICATED WRONG AS 1'-7". THE CORRECT DISTANCE | | | SHOULD BE 17". PER FBC CHAPTER 11, SECTION 11-4.18.2. | | | | | | 4. SHEET P-1, STAPLES INDICATES EXISTING 6" AND 8" RD | | | (ROOF DRAINS), HOWEVER PREVIOUS PERMIT INFORMATION | | | INDICATES THE EXISTING BUILDING BEING DEMOLISHED. NOTE: | | | PERMIT #07070444 PERMIT APPLICATION WHICH IS A | | | FOUNDATION AND SHELL PERMIT FOR THIS "STAPLES" ALSO DID | | | NOT INDICATE THE 6" AND 8" RD (ROOF DRAINS). PLEASE | | | CORRELATE THE RESUBMITTED PLANS TO REFLECT WHAT IS | | | ACTUALLY BEING BUILT. PER W.P.B. SECTION 106.1.1, | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 5. SHEET P-1, STAPLES INDICATES EXISTING 4" AND 3" | | | SANITARY LINES IN A BUILDING THAT HAS BEEN DEMOED. | | | HOWEVER THESE SANITARY LINES WERE ADDED ON A REVISION | | | ON PERMIT #07070444 WHICH WAS SUBMITTED 3/13/08 WHICH | | | IS AFTER THE SUBMITTED DATE (2/19/08) OF THIS INTERIOR | | | BUILDOUT. PLEASE CORRELATE THE RESUBMITTED PLANS TO | | | REFLECT WHAT IS ACTUALLY BEING BUILT AND TO WHICH | | | PERMIT NUMBER THE EXISTING WORK WAS BUILT TO AVOID TIME | | | CONSUMING PLAN REVIEW RESEARCH. PER W.P.B., SECTION | | | 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 6. SHEET P-1, RTU CONDENSATE DRAIN LINES ARE BEING | | | INDICATED AS DRAINING INTO EXISTING ROOF DRAINS (WHICH | | | WERE DEMOED, SEE COMMENT #4). PER FBC PLUMBING SECTION | | | 314.2.1 CONDENSATE DISPOSAL. CONDENSATE FROM ALL | | | COOLING COILS SHALL BE CONVEYED FROM THE DRAIN PAN TO | | | AN APPROVED PLACE OF DISPOSAL. ROOF DRAINS ARE NOT AN | | | APPROVED METHOD OF DISPOSAL. PLEASE INDICATE CONDENSATE | | | DISPOSAL INTO A DRY WELL, CATCH BASIN, OR PLANTED AREA. | | | | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-03-13 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-03-13 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2008-03-13 14:09:04 | INTERIOR BUILDOUT ONLY. |
|
|