| 2008-02-23 12:43:40 | BUILDING PLAN REVIEW |
| | PERMIT: 08020396 |
| | ADD: 2945 AUSTRALIAN AVE. SUITE C |
| | CONT: PETRA BUILDERS INC. |
| | TEL: (561)361-7570 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST 2-23-08 |
| | ACTION: DENIED |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 1B) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 2)106.3.3* PRODUCT APPROVALS- 2004. THOSE PRODUCTS |
| | THAT ARE REGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. SUBMIT THE PRODUCT APPROVAL |
| | FOR THE NEW DOOR. |
| | |
| | 3)THE FINISH FLOORS IN THE BATHROOM SHALL HAVE A |
| | SMOOTH, HARD, NONABSORBENT SURFACE THAT EXTENDS UPWARD |
| | ONTO THE WALLS AT LEAST 6 INCHES FBC 1210.1. ALL WALLS |
| | WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A |
| | SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF 4 |
| | FEET FBC 1210.2. NOTE: PAINT ON DRYWALL IN NOT |
| | CONSIDERED A HARD SURFACE. STATE ON THE FINISH SCHEDULE |
| | WHAT TYPE OF MATERIALS WILL BE USED TO MEET THESE |
| | REQUIREMENTS. |
| | |
| | 4)SUBMIT THE DETAIL DRAWINGS FOR THE C.M.U. AND METAL |
| | STUD WALLS. THE C.M.U. WALL DETAIL SHALL SHOW HOW THE |
| | NEW INFILL WALLS WILL TIE INTO THE EXISTING WALLS |
| | SHOWING ALL WALL TIES, STEEL ETC FBC 2109.6.3. A DETAIL |
| | DRAWING IS ALSO REQUIRED FOR THE NEW 36 INCHES C.M.U. |
| | WALL. |
| | |
| | 5) 11-4.8.4.(2) LANDINGS. ALL LANDINGS ON RAMPS SHALL |
| | NOT BE LESS THAN 60" CLEAR, & THE BOTTOM OF EACH RAMP |
| | SHALL HAVE NOT LESS THAN 72" OF STRAIGHT & LEVEL |
| | CLEARANCE. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | FAX (561) 805-6676 |
| | [email protected] |