Plan Review Details - Permit 08020351
| Plan Review Stops For Permit 08020351 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-03-17 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-03-17 |
Time |
07:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-02-19 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-02-19 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2008-02-19 11:55:02 | 2004 FBC W/2007 REVISIONS | | | STRUCTURAL REPAIRS | | | | | | DENIED BY BUILDING | | | | | | 1) A NOTICE OF COMMENCEMENT WILL BE REQUIRED. | | | | | | 2) NO UPLIFT RESISTANCE VALUES ARE PROVIDED IN THE | | | CATALOG OR STATE PRODUCT APPROVALS FOR THE SIMPSON AB66 | | | POST BASE. R301.1 DESIGN. | | | BUILDINGS AND STRUCTURES, AND ALL PARTS THEREOF, SHALL | | | BE CONSTRUCTED TO SAFELY SUPPORT ALL LOADS, INCLUDING | | | DEAD LOADS, LIVE LOADS, ROOF LOADS, FLOOD LOADS AND | | | WIND LOADS AS PRESCRIBED BY THIS CODE. THE CONSTRUCTION | | | OF BUILDINGS AND STRUCTURES SHALL RESULT IN A SYSTEM | | | THAT PROVIDES A COMPLETE LOAD PATH CAPABLE OF | | | TRANSFERRING ALL LOADS FROM THEIR POINT OF ORIGIN | | | THROUGH THE LOAD-RESISTING ELEMENTS TO THE FOUNDATION. | | | SPECIFY CONNECTORS THAT WILL PROVIDE A CONTINOUS LOAD | | | PATH FOR WIND LOADS. | | | | | | 3) SUBMIT PRODUCT APPROVALS FOR THE SIMPSON CONNECTORS | | | AS REQUIRED BY RULE 9B-72. | | | | | | 4) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-11 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-11 |
Time |
16:26 |
Sent To |
Z |
|
| Notes |
| 2008-03-11 16:26:56 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-02-19 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-02-15 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2008-02-15 10:53:32 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-13 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-13 |
Time |
13:56 |
Sent To |
B |
|
| Notes |
| 2008-03-13 14:00:39 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | | | | SENT TO "B" - RMC |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-19 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-19 |
Time |
08:33 |
Sent To |
B |
|
| Notes |
| 2008-02-19 08:34:21 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY | | | SHOWING THE LOCATION OF THE REPAIRS/IMPROVEMENTS WITH | | | SETBACK DIMENSIONS TO ALL PROPERTY LINES (FROM REPARED | | | COLUMN, AND REPLACED STAIRS). | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|