Plan Review Details - Permit 08020351
Plan Review Stops For Permit 08020351
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-03-17 Cont ID  
Sent By rmcdouga Date 2008-03-17 Time 07:49 Rev Time 0.00
Received By rmcdouga Date 2008-03-17 Time 07:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-19 Cont ID  
Sent By rmcdouga Date 2008-02-19 Time 11:55 Rev Time 0.00
Received By rmcdouga Date 2008-02-19 Time 11:55 Sent To  
Notes
2008-02-19 11:55:022004 FBC W/2007 REVISIONS
 STRUCTURAL REPAIRS
  
 DENIED BY BUILDING
  
 1) A NOTICE OF COMMENCEMENT WILL BE REQUIRED.
  
 2) NO UPLIFT RESISTANCE VALUES ARE PROVIDED IN THE
 CATALOG OR STATE PRODUCT APPROVALS FOR THE SIMPSON AB66
 POST BASE. R301.1 DESIGN.
 BUILDINGS AND STRUCTURES, AND ALL PARTS THEREOF, SHALL
 BE CONSTRUCTED TO SAFELY SUPPORT ALL LOADS, INCLUDING
 DEAD LOADS, LIVE LOADS, ROOF LOADS, FLOOD LOADS AND
 WIND LOADS AS PRESCRIBED BY THIS CODE. THE CONSTRUCTION
 OF BUILDINGS AND STRUCTURES SHALL RESULT IN A SYSTEM
 THAT PROVIDES A COMPLETE LOAD PATH CAPABLE OF
 TRANSFERRING ALL LOADS FROM THEIR POINT OF ORIGIN
 THROUGH THE LOAD-RESISTING ELEMENTS TO THE FOUNDATION.
 SPECIFY CONNECTORS THAT WILL PROVIDE A CONTINOUS LOAD
 PATH FOR WIND LOADS.
  
 3) SUBMIT PRODUCT APPROVALS FOR THE SIMPSON CONNECTORS
 AS REQUIRED BY RULE 9B-72.
  
 4) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-03-11 Cont ID  
Sent By adarroug Date 2008-03-11 Time 16:26 Rev Time 0.00
Received By adarroug Date 2008-03-11 Time 16:26 Sent To Z
Notes
2008-03-11 16:26:56TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-02-19 Cont ID  
Sent By rmcdouga Date 2008-02-19 Time 11:55 Rev Time 0.00
Received By rmcdouga Date 2008-02-15 Time 10:53 Sent To  
Notes
2008-02-15 10:53:32TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2008-03-13 Cont ID  
Sent By choops Date 2008-03-13 Time 13:56 Rev Time 0.00
Received By choops Date 2008-03-13 Time 13:56 Sent To B
Notes
2008-03-13 14:00:39***APPROVED - RESUB #1***
  
  
  
  
 SENT TO "B" - RMC

Review Stop Z ZONING
Rev No 1 Status F Date 2008-02-19 Cont ID  
Sent By choops Date 2008-02-19 Time 08:33 Rev Time 0.00
Received By choops Date 2008-02-19 Time 08:33 Sent To B
Notes
2008-02-19 08:34:21***FAILED***
  
  
 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY
 SHOWING THE LOCATION OF THE REPAIRS/IMPROVEMENTS WITH
 SETBACK DIMENSIONS TO ALL PROPERTY LINES (FROM REPARED
 COLUMN, AND REPLACED STAIRS).
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
 SENT TO "B" - MISC. 2