Plan Review Details - Permit 08020348
Plan Review Stops For Permit 08020348
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-02-25 Cont ID  
Sent By jgomez Date 2008-02-25 Time 16:18 Rev Time 0.00
Received By jgomez Date 2008-02-25 Time 16:18 Sent To PC
Notes
2008-02-25 16:32:55BUILDINGREVISION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-02-20 Cont ID  
Sent By jgomez Date 2008-02-20 Time 14:52 Rev Time 0.00
Received By jgomez Date 2008-02-20 Time 14:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-15 Cont ID  
Sent By jgomez Date 2008-02-15 Time 14:38 Rev Time 0.00
Received By jgomez Date 2008-02-15 Time 14:38 Sent To PC
Notes
2008-02-15 14:59:43RESIDENTIAL SHUTTERS, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- PROVIDE THE FOLLOWING INFORMATION IN THE SHUTTERS
 INSTALLATION SCHEDULE AND REVISE INFORMATION AS
 REQUIRED.(SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004 TO
 VERIFY COMPLIANCE WITH SEC. R301.1 OF 2004 FLORIDA
 RESIDENTIAL CODE AND COMPLIANCE WITH THE PRODUCT
 APPROVAL SUBMITTED):
 A) SPECIFY SHUTTER MOUNTING CONDITIONS. EG: WALL
 MOUNTED, BUILD-OUT MOUNTED, ETC.NO INFORMATION WAS
 SUBMITTED. AND,MARK/CIRCLE SPECIFIC MOUNTING
 CONDITIONS ON NOA 06-0823.06.
  
 B) SHUTTER GLASS SEPARATION(2 1/2",2" AND 3")
 SPECIFIED ONINSTALLATION SCHEDULE DON'T COMPLY WITH
 TABLE 2 SHOWN ON SHEET 4 OF 4 OF NOA SUBMITTED. REVISE
 AS REQUIRED.
  
 C) SPECIFY SHUTTER SPAN. NO INFORMATION WAS
 SUBMITTED.
 NOTE: THIS INFORMATION NEEDS TO BE COORDINATEDWITH
 COLUMN FOR OPENING SIZE, COLUMN FOR SHUTTER
 INSTALLATION (VERTICAL OR HORIZONTAL)AND COLUMN FOR
 MINIMUM EDGE DISTANCE.
  
 D) SPECIFY ANCHOR TYPE (SEE NOTE 1 ON INSTALLATION
 SCHEDULE FOOTNOTE). NO INFORMATION WAS PROVIDED.AND,
 MARK/CIRCLE ON PRODUCT APPROVAL SPECIFIC ANCHOR.
  
 E) SPECIFY MINIMUM EDGE DISTANCE. NO INFORMATION WAS
 SUBMITTED.
 NOTE: THIS INFORMATION NEEDS TO BE COORDINATED WITH
 SUBSTRATE COLUMN (CONCRETE, CONCRETE BLOCK OR WOOD
 FRAME).
  
 F)SPECIFY SUBSTRATE STRUCTURE TO BE ATTACHED TO (
 CONCRETE BLOCK, CONCRETE OR WOOD FRAMED). NO
 INFORMATION WAS SUBMITTED.
 NOTE:TOP OF FORM INDICATESWOOD FRAME AND CONCRETE
 CONSTRUCTION.NEED TO INDICATE SPECIFIC SUBSTRATE FOR
 EACH OPENING TO VERIFY COMPLIANCE WITH PROPOSED ANCHOR
 TYPE AND SPACING.
  
 2- PROVIDE 2 COPIES OF EVERYTHING, INCLUDING
 INSTALLATION SCHEDULES AND KEY PLANS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-02-22 Cont ID  
Sent By shill Date 2008-02-22 Time 16:23 Rev Time 0.00
Received By shill Date 2008-02-22 Time 16:23 Sent To B
Notes
2008-02-22 16:24:13TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-02-15 Cont ID  
Sent By jgomez Date 2008-02-15 Time 14:59 Rev Time 0.00
Received By jgomez Date 2008-02-14 Time 14:37 Sent To  
Notes
***NONE***