Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-03-19 Cont ID  
Sent By kconrad Date 2008-03-19 Time 17:00 Rev Time 0.00
Received By kconrad Date 2008-03-19 Time 16:15 Sent To I
Notes
2008-03-19 18:26:09RESUBMITTAL FOR WALL PAPER UNI VIOLINA #76860. THE ASTM
 E-84 TEST SUBMITTED WAS FOR PRODUCT # 70840. THE
 PRODUCT #76860UNI VIOLINA LISTED ON PAGE 5 OF THE
 GROUP SPECIFICATIONS IS CLASSIFIED AS A GROUP 4.
 PRODUCT #70840, ALSO LISTED IN GROUP4 WAS TESTED AND
 MEETS THE CLASS A FLAMESPREAD SPECIFICATIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2008-03-11 Cont ID  
Sent By kconrad Date 2008-03-11 Time 16:38 Rev Time 0.00
Received By kconrad Date 2008-03-11 Time 16:07 Sent To I
Notes
2008-03-11 16:46:22PROJECT: 700 SOUTH ROSEMARY SUITE#205/ #08020283
  
 PROJECT DETAIL: INTERIOR REMODEL /WALL AND FLOOR
 FINISHES ONLY/SUBMITTAL FOR ACOUSTICAL WALLCOVERING
 (CARPET)
  
 CODE REVIEW:
 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS
 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS
 CITY OF WEST PALM BEACH AMENDMENTS 2004 EDITION
  
  
 STATUS: DENIED
  
 COMMENTS:
  
 1) PLEASE PROVIDE THE ASTM E-84 AND/OR NFPA 265 TEST
 DATA RESULTS APPLICABLE TO THE CARPET GROUP SELECTION
 SUBMITTED:
  
 FBC, SECTION 803.6.1
 TEXTILE WALL COVERINGS.
 TEXTILE WALL COVERINGS SHALL HAVE A CLASS A FLAME
 SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE
 PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN
 ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 OR THE
 COVERING SHALL MEET THE CRITERIA OF SECTION 803.6.1.1
 OR 803.6.1.2 WHEN TESTED IN THE MANNER INTENDED FOR USE
 IN ACCORDANCE WITH NFPA 265 USING THE PRODUCT MOUNTING
 SYSTEM, INCLUDING ADHESIVE.
  
 2) THE AOR SHALL REVIEW AND ACCEPT THE PROPOSED
 APPLICATION OF #4328 ONYX AND #4361 CAJUN CARPET
 ACOUSTICAL WALLCOVERINGS.
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
 E-MAIL: KCONRAD @WPB.ORG
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-03-04 Cont ID  
Sent By kconrad Date 2008-03-04 Time 17:15 Rev Time 0.00
Received By kconrad Date 2008-03-04 Time 16:15 Sent To FIRE
Notes
2008-03-04 17:33:36PROJECT: 700 SOUTH ROSEMARY SUITE#205/ #08020283
  
 PROJECT DETAIL: INTERIOR REMODEL /WALL AND FLOOR
 FINISHES ONLY
  
 CODE REVIEW:
 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS
 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS
 CITY OF WEST PALM BEACH AMENDMENTS 2004 EDITION
  
 STATUS: SUBMITTAL APPROVED.
  
 COMMENTS:
  
 1) PROVISO SATISFIED: THE VIOLINA (GROUP4) AND OPERA
 (GROUP 8) MEET THE CLASS A SPECIFICATIONS AS PER THE
 FOLLOWING:
  
 FBC, SECTION 803.6.1 TEXTILE WALL COVERINGS. TEXTILE
 WALL COVERINGS SHALL HAVE A CLASS A FLAME SPREAD INDEX
 IN ACCORDANCE WITH ASTM E 84 AND BE PROTECTED BY
 AUTOMATIC SPRINKLERS INSTALLED IN ACCORDANCE WITH
 SECTION 903.3.1.1 OR 903.3.1.2 OR THE COVERING SHALL
 MEET THE CRITERIA OF SECTION 803.6.1.1 OR 803.6.1.2
 WHEN TESTED IN THE MANNER INTENDED FOR USE IN
 ACCORDANCE WITH NFPA 265 USING THE PRODUCT MOUNTING
 SYSTEM, INCLUDING ADHESIVE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-02-25 Cont ID  
Sent By kconrad Date 2008-02-25 Time 17:15 Rev Time 0.00
Received By kconrad Date 2008-02-25 Time 15:45 Sent To I
Notes
2008-02-26 10:00:17PROJECT: 700 SOUTH ROSEMARY SUITE#205/ #08020283
  
 PROJECT DETAIL: INTERIOR REMODEL /WALL AND FLOOR
 FINISHES ONLY
  
 CODE REVIEW:
 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS
 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS
 CITY OF WEST PALM BEACH AMENDMENTS 2004 EDITION
  
 STATUS: APPROVED
  
 COMMENTS:
  
 ************PROVISO***************
  
 PLEASE PROVIDE THE ASTM E-84 DATA FOR THE OPERA AND
 VIOLINA WALL PAPER. THE SAME MAY NOT BE APPLIED UNTIL
 ALL SPECIFICATIONS ARE REVIEWED AND APPROVED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-02-20 Cont ID  
Sent By kconrad Date 2008-02-20 Time 18:45 Rev Time 0.00
Received By kconrad Date 2008-02-20 Time 16:15 Sent To I
Notes
2008-02-20 18:54:20PROJECT: 700 SOUTH ROSEMARY SUITE#205/ #08020283
  
 PROJECT DETAIL: INTERIOR REMODEL /WALL AND FLOOR
 FINISHES ONLY
  
 CODE REVIEW:
 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS
 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS
 CITY OF WEST PALM BEACH AMENDMENTS 2004 EDITION
  
 STATUS: DENIED.
  
 COMMENTS:
  
 1) AS PER THE FLORIDA EXISTING BUILDING CODE PLEASE
 INDICATE THE LEVEL OF ALTERATION
 AS PER THE FOLLOWING:
  
 301.5 . A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO SECTION
 303,304 & 305 OF THIS CODE.
  
 2) THE PROJECT VALUATION APPEARS TO BE LOW. PLEASE
 ADJUST THE VALUATION TO REFLECT THE ACTUAL COST.
  
 3) PLEASE PROVIDE THE CERTIFICATE OF AUTHORIZATION
 NUMBER WITHIN THE TITLE BLOCK AS PER THE FOLLOWING:
  
 61G1-16.004 TITLE BLOCK.
 A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR
 INTERIOR DESIGN DRAWINGS AND SPECIFICATION
 IDENTIFICATION SHEETS. THE TITLE BLOCK
 MUST, AT A MINIMUM, CONTAIN THE FOLLOWING INFORMATION:
 (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER.
 (2) FIRM LICENSE NUMBER.
 (3) NAME OR IDENTIFICATION OF PROJECT.
 (4) DATE PREPARED.
 (5) A SPACE FOR THE SIGNATURE AND DATED SEAL.
 (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING
 THE DOCUMENT
  
 4) PLEASE INDICATE WHETHER THE WOOD LAMINATE FLOORING
 (F01) WILL BE ATTACHED DIRECTLY TO THEEXISTING
 PLATFORMS OR ELEVATED WITH WOOD SLEEPERS.
  
 5) PLEASE PROVIDE TEST DATA CONFIRMING THAT THE (F04)
 ZEBRA CARPET COMPLIES WITH THE ASTM E 84:
  
 803.6.2 TEXTILE CEILING FINISH.
 WHERE USED AS A CEILING FINISH, CARPET AND SIMILAR
 TEXTILE MATERIALS SHALL HAVE A CLASS A FLAME SPREAD
 INDEX IN ACCORDANCE WITH ASTM E 84 AND BE PROTECTED BY
 AUTOMATIC SPRINKLERS.
  
 6) PLEASE SUBMIT ASTM TESTING DATA FORTEXTILE WALL
 COVERING W16 ( VIOLINA 76815). SUBMITTED TEST RESULTS
 ARE FOR #74847:
  
 803.6.1 TEXTILE WALL COVERINGS.
 TEXTILE WALL COVERINGS SHALL HAVE A CLASS A FLAME
 SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE
 PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN
 ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 OR THE
 COVERING SHALL MEET THE CRITERIA OF SECTION 803.6.1.1
 OR 803.6.1.2 WHEN TESTED IN THE MANNER INTENDED FOR USE
 IN ACCORDANCE WITH NFPA 265 USING THE PRODUCT MOUNTING
 SYSTEM, INCLUDING ADHESIVE.
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
 E-MAIL: KCONRAD @WPB.ORG
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-19 Cont ID  
Sent By kconrad Date 2008-02-19 Time 10:40 Rev Time 0.00
Received By kconrad Date 2008-02-19 Time 10:40 Sent To I
Notes
2008-02-19 10:43:48PRE-INSPECT PERFORMED BY BT. REQUIRE FLOOR PLANS,
 FINISH SCHEDULE FOR WALLS AND CEILINGS, BUILDING TYPE,
 OCCUPANCYLOAD AND CLASSIFICATION AND FIRESPRINKLER
 PLAN IF APPLICABLE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-03-04 Cont ID  
Sent By mawillia Date 2008-03-04 Time 18:46 Rev Time 0.00
Received By mawillia Date 2008-03-04 Time 18:32 Sent To B
Notes
2008-03-04 18:46:49*****APPROVED*****
  
  
 THE SUBMITTAL OF PRODUCT INFORMATION FOR OPERA AND
 VIOLINA WALLPAPER MEETS CLASS A SPECIFICATIONS FOR
 INTERIOR WALL FINISH MATERIAL.THE APPROPIATE SHEETS
 WERE STAMPED, INITIALED, AND DATED FOR EACH PRODUCT.
  
  
 CAPT MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2008-02-26 Cont ID  
Sent By mawillia Date 2008-02-26 Time 14:22 Rev Time 0.00
Received By mawillia Date 2008-02-26 Time 14:11 Sent To B
Notes
2008-02-26 14:21:57*****APPROVED*****
  
  
 INTERIOR FINISH PRODUCT INFORMATION REVIEWED AND
 ACCEPTED;PLAN SHEET A10 STAMPED, INITIALED, AND
 DATED.
  
  
 CAPT MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-03-10 Cont ID  
Sent By adarroug Date 2008-03-10 Time 14:37 Rev Time 0.00
Received By adarroug Date 2008-03-10 Time 14:37 Sent To B
Notes
2008-03-10 14:37:38TO "KCONRAD" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-02-26 Cont ID  
Sent By adarroug Date 2008-02-26 Time 14:52 Rev Time 0.00
Received By adarroug Date 2008-02-20 Time 09:34 Sent To I
Notes
2008-02-20 09:38:21TO "KCONRAD" DESK/RESUB