Plan Review Details - Permit 08020104
| Plan Review Stops For Permit 08020104 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-10 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-10 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2008-04-10 15:14:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.THE VALUE FOR THE SITEWORK APPEARS LOW.PLEASE | | | GIVE A BREAKDOWN OF VALUE, BY SQUARE FOOT, SUMMARIZING | | | ALL WORK TO BE PERFORMED UNDER THIS SITEWORK PERMIT. | | | | | | 2.THE PLANS DO NOT APPEAR ACCURATE AS TO SCOPE OF | | | WORK.FOR INSTANCE, A HATCHED AREA IS SHOWN IN THE | | | CENTER OF THE LARGE BUILDING AS AN ADDITION, BUT MY | | | UNDERSTANDING IS THAT HALF OF THE BUILDING WAS TORN | | | DOWN AND IS IN THE PROCESS OF BEING RECONSTRUCTED, WEST | | | SIDE.CODE REQUIREMENTS FOR ACCESSIBILITY MAY BE | | | AFFECTED BY SCOPE OF WORK, SEE OTHER COMMENTS. | | | | | | 3.SEE FBC11-4.6.2, ACCESSIBLE PARKING SPACES SHALL BE | | | DISPERSED AND LOCATED CLOSEST TO THE ACCESSIBLE | | | ENTRANCES. | | | | | | 4.AN EXISTING RAMP IS SHOWN ON THE WEST SIDE OF THE | | | BUILDING.IS THIS RAMP COMPLIANT FOR ACCESSIBILITY | | | FBC11-4.8 OR IS THIS FOR LOADING? | | | | | | 5.SHOW THE ACCESSIBLE ROUTE AT THE REAR OF THE | | | BUILDING, NORTH SIDE.THE EXIT DOOR APPEARS TO HAVE A | | | LANDING, SEE FBC11-4.1.3(9), SAME NUMBER OF ACCESSIBLE | | | MEANS OF EGRESS SHALL BE PROVIDED AS REQUIRED FOR | | | EXITS.THE GRAPHIC SHOWS LANDSCAPING IN THIS AREA.IS | | | THIS A REQUIRED ACCESSIBLE EXIT?THE ACCESSIBLE ROUTE | | | TO GET AWAY FROM THE BUILDING IS NOT CLEARLY IDENTIFIED | | | ON THE NORTH, EAST, AND WEST SIDES.IT IS MY | | | UNDERSTANDING THAT A PORTION OF THE BUILDING IS NEW | | | CONSTRUCTION; WAS TORN DOWN AND REBUILT. | | | | | | 6. SHOW ALL REQUIRED DETECTABLE WARNINGS, | | | FBC11-4.29.5. | | | | | | 7. DECLARE TOTAL NUMBER OF PARKING SPACES AND NUMBER OF | | | ACCESSIBLE SPACES, FBC11-4.1.2(5)(A). | | | | | | 8.PLEASE SEE FBC11-4.1.6, OWNER HAS AN OBLIGATION TO | | | PROVIDE ACCESSIBLE FEATURES EVEN WHEN THOSE FEATURES | | | ARE NOT BEING ALTERED.THIS CODE SECTION AFFECTS OTHER | | | COMMENTS.PLEASE CONTACT ME IF YOU NEED ASSISTANCE IN | | | DETERMINING SCOPE OF REQUIRED CODE COMPLIANCE. | | | | | | 9. SEE ADA 4.29.2* DETECTABLE WARNINGS ON WALKING | | | SURFACES. DETECTABLE WARNINGS SHALL CONSIST OF RAISED | | | TRUNCATED DOMES WITH A DIAMETER OF NOMINAL 0.9 IN (23 | | | MM), A HEIGHT OF NOMINAL 0.2 IN (5 MM) AND A | | | CENTER-TO-CENTER SPACING OF NOMINAL 2.35 IN (60 MM) AND | | | SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES, EITHER | | | LIGHT-ON-DARK, OR DARK-ON-LIGHT. | | | | | | A. REVISE CONCRETE SIDEWALK CURB RAMP DETAIL, SHEET C3. | | | HTTP://WWW.ACCESS-BOARD.GOV/ADAAG/DWS/UPDATE.HTM. | | | TACTILE SURFACE SHOWN, PLEASE REVISE DETAIL TO SHOW | | | TRUNCATED DOMES. | | | | | | B. REVISE CONCRETE SIDEWALK CURB RAMP DETAIL, SHEET C3, | | | TO SHOW THE VISUAL CONTRAST REQUIRED.IF THE DESIGN | | | INTENT AND COMPLIANCE ARE NOT CLEAR, CALCULATIONS PER | | | ADA4.29.2 MAY BE REQUIRED. | | | | | | 10. SHOW ALL REQUIRED DETECTABLE WARNING LOCATIONS ON | | | THE PLAN, HAZARDOUS VEHICULAR AREAS, FBC11-4.29.5. | | | | | | 11. C2, THE GRAPHIC FOR THE ACCESSIBLE ROUTE AND SOME | | | OF THE PARKING LOT STRIPING IS THE SAME AS BUILDING | | | ADDITION AREA.PLEASE REVISE SO THAT THE TWO ARE | | | CLEARLY DEFINED.IDENTIFICATION OF THE STRIPING WOULD | | | BE HELPFUL. | | | | | | 12. SHEET C4, SECTION AA AND BB, PLEASE ADVISE AS TO | | | WHERE THESE SECTIONS ARE SHOWN ON THE PLAN.REVISE TO | | | CLEARLY SHOW COMPLIANCE WITH DETECTABLE WARNING | | | REQUIREMENTS. | | | | | | 13. C1, C2 SHOW EXISTING HANDICAP RAMPS AT VEHICULAR | | | APPROACH (STREET TO PARKING LOT) AREAS.PLEASE PROVIDE | | | A DETAIL TO SHOW COMPLIANCE WITH FBC11-4.29.5; NOTE | | | THAT EXITING IS TO THE PUBLIC WAY FBC11, DEFINITIONS. | | | | | | 14. SEE ATTACHED ACCESSIBLE PARKING DETAIL.PLEASE | | | REVISE C4 TO BE CONSISTENT WITH THIS DETAIL WHICH IS | | | REQUIRED BY MUNICIPAL CODE.NOTE THAT THE WHEEL STOP | | | DIMENSION, ACCESSIBILITY SYMBOL COLOR AND SIZE DO NOT | | | CONFORM TO THE STANDARD ADOPTED. | | | | | | 15. PROVIDE A TYPICAL ACCESSIBLE PARKING SIGN, | | | FBC11.4.6.4. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2008-03-28 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-03-28 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-03-28 |
Time |
13:22 |
Sent To |
B |
|
| Notes |
| 2008-03-28 13:38:36 | FAILED FOR FOLLOWING REASONS: | | | | | | 1.PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO. | | | 4060-07: | | | | | | ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH | | | EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY | | | APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE | | | FOLLOWING: | | | | | | 1. EROSION CONTROL, AND | | | 2. LAND STABILIZATION | | | | | | THE AMOUNT OF THE EROSION CONTROL AND LAND | | | STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER | | | OF RECORD USING THE CURRENT CITY COST SCHEDULE AND | | | VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT. | | | PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION | | | SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION. | | | | | | UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN | | | FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL | | | TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE | | | MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS. | | | | | | A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM | | | THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR. | | | | | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | DWG C-5 OF C-7 SAYS SEE DWG A1.3,THIS DWG WAS NOT IN | | | THE PACKAGE YOU SUBMITTED. PLEASE SUBMIT DWG A1.3 | | | SHOWING LOCATION & DETAILS OF DUMPSTER PER CITY | | | STANDARD. | | | | | | 3. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | | FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA | | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | | FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE | | | ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD. | | | | | | 4. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA, | | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU | | | ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE | | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | | PROVIDE A COPY OF THESE CALCULATIONS. | | | | | | 5. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH | | | REPORT&STORM WATER QUALITY CALCULATIONS. STORM | | | WATER CALS MUST BE APPROVED FROM 100045TH STREET | | | ENGINEERING SERVICES BEFORE WE APPROVED. | | | | | | YOUR SFWMD COPY WAS ISSUED IN 1992. WE DO NOT ALLOW | | | MORE THAN 5 YEAR OLD PERMIT. MAY BE YOU TAKE IT BACK TO | | | SFWMD FOR REAPPROVAL. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2008-02-20 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-02-20 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-02-20 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2008-02-20 13:54:41 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | | | | 2. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | | DETAILS,CLOTHES USED FOR SILT FENCE ETC., PLANS SHOWING | | | SILT FENCE AROUND THE SITE & STORM CATCH BASIN DRAINS | | | DURING CONSTRUCTION AND ALL DEMOLITION PHASE.HEIGHT | | | OF FENCE SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST | | | PARTICLES. | | | | | | 3. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO. | | | 4060-07: | | | | | | ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH | | | EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY | | | APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE | | | FOLLOWING: | | | | | | 1. EROSION CONTROL, AND | | | 2. LAND STABILIZATION | | | | | | THE AMOUNT OF THE EROSION CONTROL AND LAND | | | STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER | | | OF RECORD USING THE CURRENT CITY COST SCHEDULE AND | | | VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT. | | | PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION | | | SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION. | | | | | | UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN | | | FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL | | | TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE | | | MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS. | | | | | | A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM | | | THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR. | | | | | | 4. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL | | | CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING | | | SERVICES, PHONE# 494-1040 | | | | | | 5. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | 6. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | | FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA | | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | | FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE | | | ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD. | | | | | | 7. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA, | | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU | | | ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE | | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | | PROVIDE A COPY OF THESE CALCULATIONS. | | | | | | 8. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL | | | THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL | | | ENVRONMENTAL REPORT. | | | | | | 9. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET | | | FLOODED AND HAVE ENOUGH DRAINS. | | | | | | 10. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH | | | REPORT&STORM WATER QUALITY CALCULATIONS. STORM | | | WATER CALS MUST BE APPROVED FROM 100045TH STREET | | | ENGINEERING SERVICES BEFORE WE APPROVED. | | | | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-25 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-03-26 |
Time |
17:58 |
Sent To |
Z |
|
| Notes |
| 2008-03-25 14:00:45 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-02-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-11 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-11 |
Time |
11:44 |
Sent To |
ENG |
|
| Notes |
| 2008-02-11 11:44:35 | TO "ENG" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-02-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-06 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2008-02-06 11:03:12 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-03-26 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-03-26 |
Time |
17:58 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-02-28 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-02-28 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-11 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-02-11 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-02-11 |
Time |
08:50 |
Sent To |
I |
|
| Notes |
| 2008-02-11 08:59:21 | ***FAILED*** | | | | | | 1. PLEASE PROVIDE THE RECORDED DOCUMENTS SHOWING THAT | | | THE 20- FOOT ALLEY EASEMENT HAS BEEN MODIFED AS SHOWN | | | ON SHEET C-1. NOTE THAT ZONING WILL NOT PASS THESE | | | PLANS UNTIL THAT DOCUMENTATION HAS BEEN PROVIDED. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT (561) | | | 822-1435 OR [email protected] WITH QUESTIONS. |
|
|
|