Plan Review Details - Permit 08010739
Plan Review Stops For Permit 08010739
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-27 Cont ID  
Sent By jwitmer Date 2008-08-27 Time 11:16 Rev Time 0.77
Received By jwitmer Date 2008-08-27 Time 11:07 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-06-03 Cont ID  
Sent By jwitmer Date 2008-06-03 Time 16:16 Rev Time 0.77
Received By jwitmer Date 2008-06-03 Time 16:16 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-11 Cont ID  
Sent By jwitmer Date 2008-02-11 Time 21:43 Rev Time 0.77
Received By jwitmer Date 2008-02-11 Time 21:43 Sent To  
Notes
2008-02-11 21:44:00 
 BUILDING PLAN REVIEW
 PERMIT: 08010739
 ADD: 6917 OKEECHOBEE BLVD
 CONT: PETROLEUM AND CONSTRUCTION
 TEL: (954)445-3099
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT.
 IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF
 YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A
 THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 2) PLANS DO NOT PROVIDE TO WHAT WIND DESIGN CRITERIA
 THEY ARE DESIGNED TO? PLANS DO NOT PROVIDE HOW THE NEW
 DISPENSING PUMPS ARE TO BE INSTALLED, SHEET 2 OF 3 DOES
 INDICATE NEW WAYNE OVATION DISPENSERS.
 1609.6.2 WIND DESIGN PROCEDURES
 1)THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE
 ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION.
  
 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN
 ACCORDANCE WTIH SECTION1609.5.
  
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4.
  
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4).
  
 3) PLANS INDICATE THERE TO BE A THIRD SHEET BUT ONLY
 TWO SHEETS WERE SUBMITTED. 106.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 4) PLEASE PROVIDE THE HIGHEST OPERABLE PART OF
 CONTROLS, DISPENSER AND OTHER OPERABLE EQUIPMENT SHALL
 BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES
 SPECIFIED IN SECTION
 11-4.2.5 AND 11-4.2.6.(11-4.27) CHAPTER 11
 ACCESSIBILITY.
  
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-08-13 Cont ID  
Sent By dpalmer Date 2008-08-13 Time 08:22 Rev Time 0.00
Received By dpalmer Date 2008-08-13 Time 08:22 Sent To M
Notes
2008-08-13 08:24:01NEW REVISED SHEETS FOR MECH AND BLDG.PLANS ROUTED FOR
 RE-STAMPING.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-06-02 Cont ID  
Sent By dpalmer Date 2008-06-02 Time 15:51 Rev Time 0.00
Received By dpalmer Date 2008-06-02 Time 15:51 Sent To  
Notes
2008-06-02 15:52:04** DENIEDRESUB**
  
  
 1) NOTE: PLEASE SUBMIT ELECTRICAL DETAILS FOR SCOPE OF
 WORK. THE ELECTRICAL SHEET SUBMITTED QUOTING THE SCOPE
 OF WORK IN LIEU OF ELECTRICAL DETAILS IS NOT
 ACCEPTABLE.
 PLEASE SEE NEC 514 AND SHOW ELECTRICAL DETAILS, WIRING,
 SEAL OFFS MENTIONED, LOCATIONS ETC,
 PLEASE INCLUDE NEW OR EXISTING EMERGENCY SHUT OFF PER
 514.11
 FBC 106.3.5.1.2, 106.1.2
  
 ** IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF
 THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-02-06 Cont ID  
Sent By dpalmer Date 2008-02-06 Time 16:05 Rev Time 0.00
Received By dpalmer Date 2008-02-06 Time 16:05 Sent To  
Notes
2008-02-06 16:05:25** DENIED REVIEW **
  
 1) NOTE: PLEASE SUBMIT ELECTRICAL PLANS FOR ELECTRICAL
 SCOPE SHOWING CONDUITS, SEAL OFFS, CONDUCTORS, CLASS
 LOCATIONS AND INSTALLATION REQUIREMENTS
 PLEASE INDICATE NEW OR EXISTING EMERGENCY SHUT OFFS.
 310.16, 240.4, AND NEC 514 (ALL).
 FBC 106.3.5.1.2, 106.1.2 FOR ADDITIONAL INFORMATION.
  
 ** PLEASE BE AWARE THE COMMENTS ARE BASED ON PLANS AND
 DOCUMENTS SUBMITTED FOR REVIEW. ANY CHANGES IN DESIGN,
 LOCATIONS AND/OR ADDITIONAL INFORMATION SUBMITTED WHICH
 COULD NOT YET BE REVIEW MAY GENERATE NEW COMMENTS WHICH
 COULD NOT BE MADE AT THIS TIME.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-08-25 Cont ID  
Sent By mawillia Date 2008-08-25 Time 13:02 Rev Time 0.00
Received By mawillia Date 2008-08-25 Time 12:54 Sent To  
Notes
2008-08-25 13:02:30******APPROVED*****
  
  
 PLAN SHEET 2 (OF 3) STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2008-02-15 Cont ID  
Sent By mwennerg Date 2008-02-15 Time 13:06 Rev Time 0.00
Received By mwennerg Date 2008-02-15 Time 13:06 Sent To  
Notes
2008-02-15 13:10:241) WORK TO COMPLY WITH NFPA 30 IN ADDITION TO OTHER
 APPLICABLE CODES.
  
 2) MULTI-PURPOSE FIRE EXTINGUISHERS TO BE AVAILABLE.
  
 3) THIS APPROVAL DOES NOT RELIEVE RESPONSIBLE PERSONS
 OR FIRMS FROM OBTAINING OTHER GOVERNMENTAL APPROVALS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-08-07 Cont ID  
Sent By adarroug Date 2008-08-07 Time 10:49 Rev Time 0.00
Received By adarroug Date 2008-08-07 Time 10:49 Sent To E
Notes
2008-08-13 09:40:198/13/08--NEW SHEETS FOR "BLDG", AND "MECH", TO "COMM"
 BD#22
2008-08-07 10:49:51TO "DPALMER' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-05-13 Cont ID  
Sent By adarroug Date 2008-05-13 Time 10:51 Rev Time 0.00
Received By adarroug Date 2008-05-13 Time 10:51 Sent To  
Notes
2008-05-13 10:53:58TO "COMM" BD#41

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-02-20 Cont ID  
Sent By adarroug Date 2008-02-20 Time 10:47 Rev Time 0.00
Received By adarroug Date 2008-01-30 Time 16:59 Sent To  
Notes
2008-01-30 16:59:36TO "COMM" BD#58

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-08-18 Cont ID  
Sent By tgordon Date 2008-08-18 Time 11:49 Rev Time 0.30
Received By tgordon Date 2008-08-18 Time 11:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-02-06 Cont ID  
Sent By tgordon Date 2008-02-06 Time 14:17 Rev Time 0.25
Received By tgordon Date 2008-02-06 Time 14:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2008-02-20 Cont ID  
Sent By kdfreema Date 2008-02-20 Time 10:10 Rev Time 0.00
Received By kdfreema Date 2008-02-20 Time 10:10 Sent To  
Notes
***NONE***