Plan Review Details - Permit 08010673
Plan Review Stops For Permit 08010673
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-04-04 Cont ID  
Sent By mjacobs Date 2008-04-04 Time 17:14 Rev Time 0.00
Received By mjacobs Date 2008-04-04 Time 15:21 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-03-17 Cont ID  
Sent By mjacobs Date 2008-03-17 Time 11:08 Rev Time 0.00
Received By mjacobs Date 2008-03-17 Time 08:01 Sent To PC
Notes
2008-03-17 11:07:56BUILDING PLAN REVIEW
 PERMIT: 08010673
 ADD: 800 N. FLAGLER DR.
 CONT: GLACE & CO. INC
 TEL: (561)585-5564
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
 3-17-08
  
 1A)OK
 1B) OK
 1C) OK
 2)OK
 3)OK
 4) OK
 5)OK
  
 OK
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-05 Cont ID  
Sent By mjacobs Date 2008-02-05 Time 15:50 Rev Time 0.00
Received By mjacobs Date 2008-02-05 Time 12:37 Sent To  
Notes
2008-02-05 15:49:22 
  
 BUILDING PLAN REVIEW
 PERMIT: 08010673
 ADD: 800 N. FLAGLER DR.
 CONT: GLACE & CO. INC
 TEL: (561)585-5564
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
 2-5-08
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 1B) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1C) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 2) TABLE 803.5 MINIMUM INTERIOR FINISH CLASSIFICATION;
 PROVIDE INFORMATION BASED ON INTERIOR FINISH
 REQUIREMENTS BASED ON OCCUPANCY
  
 3)2004 FBC EXISTING
 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 4) FBC CH.3 INDICATE THE USE AND OCCUPANCY ALONG WITH
 THE OCCUPANT LOAD OF THE BUILDING PER FBC TABLE
 1004.1.2 AND STATE THE USE OF EACH ROOM.
 5)INDICATE THE WALL RATING OF THE NEW CONSTRUCTED
 WALL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION AND NATURE OF THE WORK
 PROPOSED. FBC 106.1.1
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-08-18 Cont ID  
Sent By btrobaug Date 2008-08-18 Time 11:52 Rev Time 0.00
Received By btrobaug Date 2008-08-18 Time 11:33 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-03-25 Cont ID  
Sent By btrobaug Date 2008-03-25 Time 10:56 Rev Time 0.00
Received By btrobaug Date 2008-03-25 Time 10:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-03-12 Cont ID  
Sent By btrobaug Date 2008-03-12 Time 10:00 Rev Time 0.00
Received By btrobaug Date 2008-03-12 Time 07:39 Sent To  
Notes
2008-03-12 10:00:06 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK
 MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002
 FAC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-02-01 Cont ID  
Sent By btrobaug Date 2008-02-01 Time 14:57 Rev Time 0.00
Received By btrobaug Date 2008-02-01 Time 07:46 Sent To  
Notes
2008-02-01 14:57:44 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} 13-415.1.ABC.1.2 SPACE CONTROL.
 EACH SPACE ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL
 HAVE AT LEAST ONE CONTROL DEVICE TO INDEPENDENTLY
 CONTROL THE GENERAL LIGHTING WITHIN THE SPACE. EACH
 MANUAL DEVICE SHALL BE READILY ACCESSIBLE AND LOCATED
 SO THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING. A. A
 CONTROL DEVICE SHALL BE INSTALLED THAT AUTOMATICALLY
 TURNS LIGHTING OFF WITHIN 30 MINUTES OF ALL OCCUPANTS
 LEAVING A SPACE, EXCEPT SPACES WITH MULTISCENE CONTROL,
 IN THE FOLLOWING: 1. CLASSROOMS (NOT INCLUDING SHOP
 CLASSROOMS, LABORATORY CLASSROOMS, AND PRESCHOOL
 THROUGH 12TH GRADE CLASSROOMS).
 2. CONFERENCE/MEETING ROOMS.
 3. EMPLOYEE LUNCH AND BREAK ROOMS.
 INDICATE SAME OM PLANS.
  
 2} THE CALCULATED LOAD (SHEET E-3) FOR THE A/C
 EQUIPMENT DOES NOT MATCH THE MECHANICAL SPECS ON SHEET
 M-1, CORRELATE SAME.
  
 NOTE:PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL
 BE BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE
 CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE SEE
 ARTICLE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-04-03 Cont ID  
Sent By mawillia Date 2008-04-03 Time 17:44 Rev Time 0.00
Received By mawillia Date 2008-04-03 Time 16:37 Sent To  
Notes
2008-04-03 17:51:00*****APPROVED*****
  
  
 PLAN SHEETS A-1, A-2, AND E-1 WERE STAMPED, INITIALED,
 AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2008-03-14 Cont ID  
Sent By mwennerg Date 2008-03-14 Time 15:25 Rev Time 0.00
Received By mwennerg Date 2008-03-14 Time 15:25 Sent To  
Notes
2008-03-14 15:29:30***DENIED***
  
 A RESPONSE LETTER IS NOT REQUIRED, BUT WOULD HELP
 EXPEDITE THE PLAN REVIEW PROCESS. MOST OF THE PREVIOUS
 COMMENTS WOULD REQUIRE ACKNOWLEDGEMENT EITHER BY NOTES
 ON THE PLANS OR A RESPONSE LETTER.
  
 1) OK
  
 2) WILL THIS WORK IMPACT EXISTING FIRE PROTECTION
 EQUIPMENT?
  
 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
 4) CONSTRUCTION SITE SHALL BE MAINTAINED AND KEPT CLEAN
 OF EXCESSIVE DEBRIS ON A DAILY BASIS.
  
 5) OK
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-02-13 Cont ID  
Sent By mwennerg Date 2008-02-13 Time 11:05 Rev Time 0.00
Received By mwennerg Date 2008-02-13 Time 11:05 Sent To  
Notes
2008-02-13 11:15:46***DENIED***
  
 1) PLEASE CLARIFY OCCUPANCY USE FOR SPACE.
  
 2) WILL THIS WORK IMPACT EXISTING FIRE PROTECTION
 EQUIPMENT?
  
 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
 4) CONSTRUCTION SITE SHALL BE MAINTAINED AND KEPT CLEAN
 OF EXCESSIVE DEBRIS ON A DAILY BASIS.
  
 5) PLEASE ILLUSTRATE OR NOTE THE CLOSEST LOCATION OF
 REQUIRED 2A-10B,C RATED FIRE EXTINGUISHER.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-09-19 Cont ID  
Sent By tgordon Date 2008-09-19 Time 16:18 Rev Time 0.00
Received By tgordon Date 2008-09-19 Time 16:18 Sent To M
Notes
2008-09-19 16:18:53TO MECH. BOX, RE-STAMP.

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2008-09-19 Cont ID  
Sent By adarroug Date 2008-09-19 Time 09:51 Rev Time 0.00
Received By adarroug Date 2008-09-19 Time 09:51 Sent To M
Notes
2008-09-19 09:51:32TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-08-11 Cont ID  
Sent By adarroug Date 2008-08-11 Time 10:58 Rev Time 0.00
Received By adarroug Date 2008-08-11 Time 10:58 Sent To E
Notes
2008-08-11 10:59:09TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-05-22 Cont ID  
Sent By adarroug Date 2008-05-22 Time 15:01 Rev Time 0.00
Received By adarroug Date 2008-05-22 Time 15:01 Sent To M
Notes
2008-05-22 15:02:48TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-05-21 Cont ID  
Sent By adarroug Date 2008-05-21 Time 11:23 Rev Time 0.00
Received By adarroug Date 2008-05-21 Time 11:23 Sent To M
Notes
2008-05-21 11:23:53TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-05-15 Cont ID  
Sent By adarroug Date 2008-05-15 Time 10:04 Rev Time 0.00
Received By adarroug Date 2008-05-15 Time 10:04 Sent To M
Notes
2008-05-15 10:04:50TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-03-24 Cont ID  
Sent By adarroug Date 2008-03-24 Time 11:50 Rev Time 0.00
Received By adarroug Date 2008-03-24 Time 11:50 Sent To  
Notes
2008-03-24 11:54:18TO "BOB"#7

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-03-10 Cont ID  
Sent By adarroug Date 2008-03-10 Time 14:53 Rev Time 0.00
Received By adarroug Date 2008-03-10 Time 14:53 Sent To  
Notes
2008-03-10 14:57:01TO "BOB"#1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-02-13 Cont ID  
Sent By mwennerg Date 2008-02-13 Time 11:20 Rev Time 0.00
Received By mwennerg Date 2008-01-29 Time 14:05 Sent To  
Notes
2008-01-29 14:09:39TO "BOB"#10

Review Stop M MECHANICAL (A/C)
Rev No 10 Status P Date 2008-10-02 Cont ID  
Sent By tgordon Date 2008-10-02 Time 14:08 Rev Time 0.30
Received By tgordon Date 2008-10-02 Time 14:08 Sent To  
Notes
2008-10-02 14:09:20REVISED CONDENSER STAND ENGINEERING DETAIL.

Review Stop M MECHANICAL (A/C)
Rev No 9 Status P Date 2008-10-02 Cont ID  
Sent By tgordon Date 2008-10-02 Time 14:07 Rev Time 0.45
Received By tgordon Date 2008-10-02 Time 14:07 Sent To  
Notes
2008-10-02 14:07:52REVISION TO MECH. PLAN M-1.

Review Stop M MECHANICAL (A/C)
Rev No 8 Status F Date 2008-09-22 Cont ID  
Sent By tgordon Date 2008-09-22 Time 09:10 Rev Time 0.30
Received By tgordon Date 2008-09-22 Time 09:10 Sent To  
Notes
2008-09-22 09:16:53PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 RE-STAMP *** DENIED ***
  
 1) PLEASE HAVE THE ENGINEER ADD THE WIND LOAD
 CALCULATIONS TO THE CONDENSER STAND ENGINEERING, PER
 2004 FBC 1609.
  
 ** NOTICE: THIS IS A REVISION TO THE PLANS. PLEASE
 SUBMIT TWO COPIES AND SUBMIT WITH THE REVISION TO PLAN
 M-1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 7 Status F Date 2008-09-22 Cont ID  
Sent By tgordon Date 2008-09-22 Time 08:59 Rev Time 0.45
Received By tgordon Date 2008-09-22 Time 08:59 Sent To  
Notes
2008-09-22 09:06:11PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 REVISION TO MECHANICAL PLAN M-1
 *** DENIED ***
  
 1) PLEASE SUBMIT NEW ENGINEERING FOR CONDENSER STAND
 WITH WIND LOAD CALCULATIONS WHEN RESUBMITTING THIS
 REVISION, PER 2004 FBC 1609.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2008-05-22 Cont ID  
Sent By tgordon Date 2008-05-22 Time 16:42 Rev Time 0.00
Received By tgordon Date 2008-05-22 Time 15:50 Sent To  
Notes
2008-05-22 16:42:44REVISION TO MECH. PLAN M-1.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2008-05-22 Cont ID  
Sent By tgordon Date 2008-05-22 Time 10:28 Rev Time 0.30
Received By tgordon Date 2008-05-22 Time 10:28 Sent To  
Notes
2008-05-22 10:32:41PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 MECHANICAL REVISION PG. M-1
 *** DENIED ***
 1) ONE PLAN HAS NOT BEEN SEALED BY THE ENGINEER, PLEASE
 CORRECT PER FAC 61G15-23.002.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2008-05-15 Cont ID  
Sent By tgordon Date 2008-05-15 Time 16:01 Rev Time 0.30
Received By tgordon Date 2008-05-15 Time 16:01 Sent To  
Notes
2008-05-15 16:02:15REVISION TO MECH. PLAN M-1.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-03-25 Cont ID  
Sent By tgordon Date 2008-03-25 Time 09:16 Rev Time 0.25
Received By tgordon Date 2008-03-25 Time 09:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-03-11 Cont ID  
Sent By tgordon Date 2008-03-11 Time 07:56 Rev Time 0.45
Received By tgordon Date 2008-03-11 Time 07:56 Sent To  
Notes
2008-03-11 08:24:54PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) TWO COPIES OF THE ENERGY CALCULATIONS AND COOLING
 LOAD CALCULATIONS NEED TO BE SUBMITTED PER 2004 WPB
 AMEND. 106.1.
  
 2) COOLING LOAD CALCULATIONS ARE CALLING FOR 97,985
 TOTAL COOLING BTU'S OR 8.17 TONS, THE MECHANICAL PLAN
 EQUIPMENT SCHEDULE IS SHOWING 42,000 TOTAL COOLING
 BTU'S. PER 2004 FBC 13-407.1.ABC.1.1,HVAC SYSTEMS AND
 EQUIPMENT SHALL BE SIZED TO PROVIDE NO MORE THAN THE
 SPACE AND SYSTEM LOADS CALCULATED IN ACCORDANCE WITH
 SECTION 407.1.ABC.1 . A SINGLE PIECE OF EQUIPMENT
 PROVIDING BOTH COOLING AND HEATING SHALL SATISFY THIS
 PROVISION WHEN THE COOLING FUNCTION MEETS THE
 PROVISIONS OF SECTION 407.1.ABC.1 , AND THE HEATING
 FUNCTION IS SIZED AS SMALL AS POSSIBLE TO MEET THE LOAD
 WITHIN AVAILABLE EQUIPMENT OPTIONS. PLEASE CORRECT
 COOLING LOAD CALCULATIONS.
  
 3) NOT NOTICED IN LAST REVIEW MECHANICAL PLAN OUTSIDE
 AIR CALCULATIONS ARE REFERENCING 2007 ASHRAE 62, THE
 CITY OF W.P.B. HAS NOT ADOPTED THE 2007 ASHRAE 62 BUT
 IS USING THE 2004 ASHRAE 62, PLEASE CORRECT.
  
 4) NOT NOTICED IN LAST REVIEW MECHANICAL PLAN OUTSIDE
 AIR CALCULATIONS ARE REFERENCING SECTION 6.1.3.4 OF
 ASHRAE 62 PLEASE BE AWARE I COULD NOT FIND ANY SUCH
 SECTION IN ASHRAE 62. PLEASE SEE SECTION 6.2.6.1 OF
 2004 ASHRAE 62 FOR VARIABLE LOAD CONDITIONS. PLEASE
 CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-01-30 Cont ID  
Sent By tgordon Date 2008-01-30 Time 11:19 Rev Time 1.30
Received By tgordon Date 2008-01-30 Time 11:19 Sent To  
Notes
2008-01-30 11:45:57PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS FORM A MAY NOT BE USE FOR A
 RENOVATION, SEE 2004 FBC 13-101.1.3. PLEASE SUBMIT FORM
 C OR B.
  
 2)PLEASE SUBMITCOOLING LOAD CALCULATIONS, SEE 2004
 FBC 13-407.1.ABC.1.
  
 3) PLEASE PROVIDE WIND LOAD CALCULATIONS FOR A/C
 CONDENSED UNIT AND STAND ON PAGE M-1, SEE 2004 FBC/M
 301.13.
  
 4) A/C SYSTEM LISTED ON A/C EQUIPMENT SCHEDULE COULD
 NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE, PLEASE
 CORRECT OR SUBMIT AN ARI CERTIFICATE, SEE 2004 FBC
 13-407.1.ABC.3.1.1.
  
 5) A/C EQUIPMENT SCHEDULE ON PLAN M-1 SHOWS KW HEAT AS
 88 KW, PLEASE CORRECT.
  
 6) PLEASE STATE WHERE THE CONDENSATE LINE WILL DISPOSE
 TO, SEE 2004 FBC/M 307.2.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-01-31 Cont ID  
Sent By choops Date 2008-01-31 Time 08:31 Rev Time 0.00
Received By choops Date 2008-01-31 Time 08:31 Sent To  
Notes
2008-01-31 08:32:15 
 *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.