| Plan Review Stops For Permit 08010673 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-04 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-04 |
Time |
15:21 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-03-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-17 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-03-17 |
Time |
08:01 |
Sent To |
PC |
|
| Notes |
| 2008-03-17 11:07:56 | BUILDING PLAN REVIEW | | | PERMIT: 08010673 | | | ADD: 800 N. FLAGLER DR. | | | CONT: GLACE & CO. INC | | | TEL: (561)585-5564 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 2ND | | | ACTION: DENIED | | | 3-17-08 | | | | | | 1A)OK | | | 1B) OK | | | 1C) OK | | | 2)OK | | | 3)OK | | | 4) OK | | | 5)OK | | | | | | OK | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-02-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-02-05 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-02-05 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2008-02-05 15:49:22 | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 08010673 | | | ADD: 800 N. FLAGLER DR. | | | CONT: GLACE & CO. INC | | | TEL: (561)585-5564 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | 2-5-08 | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1C) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 2) TABLE 803.5 MINIMUM INTERIOR FINISH CLASSIFICATION; | | | PROVIDE INFORMATION BASED ON INTERIOR FINISH | | | REQUIREMENTS BASED ON OCCUPANCY | | | | | | 3)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 4) FBC CH.3 INDICATE THE USE AND OCCUPANCY ALONG WITH | | | THE OCCUPANT LOAD OF THE BUILDING PER FBC TABLE | | | 1004.1.2 AND STATE THE USE OF EACH ROOM. | | | 5)INDICATE THE WALL RATING OF THE NEW CONSTRUCTED | | | WALL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION AND NATURE OF THE WORK | | | PROPOSED. FBC 106.1.1 | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-18 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-18 |
Time |
11:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-25 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-25 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-12 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-12 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2008-03-12 10:00:06 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK | | | MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 | | | FAC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-01 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-01 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2008-02-01 14:57:44 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} 13-415.1.ABC.1.2 SPACE CONTROL. | | | EACH SPACE ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL | | | HAVE AT LEAST ONE CONTROL DEVICE TO INDEPENDENTLY | | | CONTROL THE GENERAL LIGHTING WITHIN THE SPACE. EACH | | | MANUAL DEVICE SHALL BE READILY ACCESSIBLE AND LOCATED | | | SO THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING. A. A | | | CONTROL DEVICE SHALL BE INSTALLED THAT AUTOMATICALLY | | | TURNS LIGHTING OFF WITHIN 30 MINUTES OF ALL OCCUPANTS | | | LEAVING A SPACE, EXCEPT SPACES WITH MULTISCENE CONTROL, | | | IN THE FOLLOWING: 1. CLASSROOMS (NOT INCLUDING SHOP | | | CLASSROOMS, LABORATORY CLASSROOMS, AND PRESCHOOL | | | THROUGH 12TH GRADE CLASSROOMS). | | | 2. CONFERENCE/MEETING ROOMS. | | | 3. EMPLOYEE LUNCH AND BREAK ROOMS. | | | INDICATE SAME OM PLANS. | | | | | | 2} THE CALCULATED LOAD (SHEET E-3) FOR THE A/C | | | EQUIPMENT DOES NOT MATCH THE MECHANICAL SPECS ON SHEET | | | M-1, CORRELATE SAME. | | | | | | NOTE:PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL | | | BE BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE | | | CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE SEE | | | ARTICLE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-04-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-03 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-03 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2008-04-03 17:51:00 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A-1, A-2, AND E-1 WERE STAMPED, INITIALED, | | | AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-03-14 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-03-14 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2008-03-14 15:29:30 | ***DENIED*** | | | | | | A RESPONSE LETTER IS NOT REQUIRED, BUT WOULD HELP | | | EXPEDITE THE PLAN REVIEW PROCESS. MOST OF THE PREVIOUS | | | COMMENTS WOULD REQUIRE ACKNOWLEDGEMENT EITHER BY NOTES | | | ON THE PLANS OR A RESPONSE LETTER. | | | | | | 1) OK | | | | | | 2) WILL THIS WORK IMPACT EXISTING FIRE PROTECTION | | | EQUIPMENT? | | | | | | 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. | | | | | | 4) CONSTRUCTION SITE SHALL BE MAINTAINED AND KEPT CLEAN | | | OF EXCESSIVE DEBRIS ON A DAILY BASIS. | | | | | | 5) OK | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-02-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-02-13 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-02-13 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2008-02-13 11:15:46 | ***DENIED*** | | | | | | 1) PLEASE CLARIFY OCCUPANCY USE FOR SPACE. | | | | | | 2) WILL THIS WORK IMPACT EXISTING FIRE PROTECTION | | | EQUIPMENT? | | | | | | 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. | | | | | | 4) CONSTRUCTION SITE SHALL BE MAINTAINED AND KEPT CLEAN | | | OF EXCESSIVE DEBRIS ON A DAILY BASIS. | | | | | | 5) PLEASE ILLUSTRATE OR NOTE THE CLOSEST LOCATION OF | | | REQUIRED 2A-10B,C RATED FIRE EXTINGUISHER. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-09-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-19 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-09-19 |
Time |
16:18 |
Sent To |
M |
|
| Notes |
| 2008-09-19 16:18:53 | TO MECH. BOX, RE-STAMP. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-19 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-19 |
Time |
09:51 |
Sent To |
M |
|
| Notes |
| 2008-09-19 09:51:32 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-11 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-11 |
Time |
10:58 |
Sent To |
E |
|
| Notes |
| 2008-08-11 10:59:09 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-22 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-22 |
Time |
15:01 |
Sent To |
M |
|
| Notes |
| 2008-05-22 15:02:48 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-21 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-21 |
Time |
11:23 |
Sent To |
M |
|
| Notes |
| 2008-05-21 11:23:53 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-15 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-15 |
Time |
10:04 |
Sent To |
M |
|
| Notes |
| 2008-05-15 10:04:50 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-24 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-24 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2008-03-24 11:54:18 | TO "BOB"#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-10 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-10 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2008-03-10 14:57:01 | TO "BOB"#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-02-13 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-29 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2008-01-29 14:09:39 | TO "BOB"#10 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
P |
Date |
2008-10-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-02 |
Time |
14:08 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-10-02 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2008-10-02 14:09:20 | REVISED CONDENSER STAND ENGINEERING DETAIL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2008-10-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-02 |
Time |
14:07 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-10-02 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2008-10-02 14:07:52 | REVISION TO MECH. PLAN M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
F |
Date |
2008-09-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-22 |
Time |
09:10 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-09-22 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2008-09-22 09:16:53 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | RE-STAMP *** DENIED *** | | | | | | 1) PLEASE HAVE THE ENGINEER ADD THE WIND LOAD | | | CALCULATIONS TO THE CONDENSER STAND ENGINEERING, PER | | | 2004 FBC 1609. | | | | | | ** NOTICE: THIS IS A REVISION TO THE PLANS. PLEASE | | | SUBMIT TWO COPIES AND SUBMIT WITH THE REVISION TO PLAN | | | M-1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2008-09-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-22 |
Time |
08:59 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-09-22 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2008-09-22 09:06:11 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLAN M-1 | | | *** DENIED *** | | | | | | 1) PLEASE SUBMIT NEW ENGINEERING FOR CONDENSER STAND | | | WITH WIND LOAD CALCULATIONS WHEN RESUBMITTING THIS | | | REVISION, PER 2004 FBC 1609. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-22 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-05-22 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2008-05-22 16:42:44 | REVISION TO MECH. PLAN M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-22 |
Time |
10:28 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-05-22 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2008-05-22 10:32:41 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | MECHANICAL REVISION PG. M-1 | | | *** DENIED *** | | | 1) ONE PLAN HAS NOT BEEN SEALED BY THE ENGINEER, PLEASE | | | CORRECT PER FAC 61G15-23.002. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-15 |
Time |
16:01 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-05-15 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2008-05-15 16:02:15 | REVISION TO MECH. PLAN M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-25 |
Time |
09:16 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-03-25 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-11 |
Time |
07:56 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-03-11 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2008-03-11 08:24:54 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) TWO COPIES OF THE ENERGY CALCULATIONS AND COOLING | | | LOAD CALCULATIONS NEED TO BE SUBMITTED PER 2004 WPB | | | AMEND. 106.1. | | | | | | 2) COOLING LOAD CALCULATIONS ARE CALLING FOR 97,985 | | | TOTAL COOLING BTU'S OR 8.17 TONS, THE MECHANICAL PLAN | | | EQUIPMENT SCHEDULE IS SHOWING 42,000 TOTAL COOLING | | | BTU'S. PER 2004 FBC 13-407.1.ABC.1.1,HVAC SYSTEMS AND | | | EQUIPMENT SHALL BE SIZED TO PROVIDE NO MORE THAN THE | | | SPACE AND SYSTEM LOADS CALCULATED IN ACCORDANCE WITH | | | SECTION 407.1.ABC.1 . A SINGLE PIECE OF EQUIPMENT | | | PROVIDING BOTH COOLING AND HEATING SHALL SATISFY THIS | | | PROVISION WHEN THE COOLING FUNCTION MEETS THE | | | PROVISIONS OF SECTION 407.1.ABC.1 , AND THE HEATING | | | FUNCTION IS SIZED AS SMALL AS POSSIBLE TO MEET THE LOAD | | | WITHIN AVAILABLE EQUIPMENT OPTIONS. PLEASE CORRECT | | | COOLING LOAD CALCULATIONS. | | | | | | 3) NOT NOTICED IN LAST REVIEW MECHANICAL PLAN OUTSIDE | | | AIR CALCULATIONS ARE REFERENCING 2007 ASHRAE 62, THE | | | CITY OF W.P.B. HAS NOT ADOPTED THE 2007 ASHRAE 62 BUT | | | IS USING THE 2004 ASHRAE 62, PLEASE CORRECT. | | | | | | 4) NOT NOTICED IN LAST REVIEW MECHANICAL PLAN OUTSIDE | | | AIR CALCULATIONS ARE REFERENCING SECTION 6.1.3.4 OF | | | ASHRAE 62 PLEASE BE AWARE I COULD NOT FIND ANY SUCH | | | SECTION IN ASHRAE 62. PLEASE SEE SECTION 6.2.6.1 OF | | | 2004 ASHRAE 62 FOR VARIABLE LOAD CONDITIONS. PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-30 |
Time |
11:19 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-01-30 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2008-01-30 11:45:57 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS FORM A MAY NOT BE USE FOR A | | | RENOVATION, SEE 2004 FBC 13-101.1.3. PLEASE SUBMIT FORM | | | C OR B. | | | | | | 2)PLEASE SUBMITCOOLING LOAD CALCULATIONS, SEE 2004 | | | FBC 13-407.1.ABC.1. | | | | | | 3) PLEASE PROVIDE WIND LOAD CALCULATIONS FOR A/C | | | CONDENSED UNIT AND STAND ON PAGE M-1, SEE 2004 FBC/M | | | 301.13. | | | | | | 4) A/C SYSTEM LISTED ON A/C EQUIPMENT SCHEDULE COULD | | | NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE, PLEASE | | | CORRECT OR SUBMIT AN ARI CERTIFICATE, SEE 2004 FBC | | | 13-407.1.ABC.3.1.1. | | | | | | 5) A/C EQUIPMENT SCHEDULE ON PLAN M-1 SHOWS KW HEAT AS | | | 88 KW, PLEASE CORRECT. | | | | | | 6) PLEASE STATE WHERE THE CONDENSATE LINE WILL DISPOSE | | | TO, SEE 2004 FBC/M 307.2.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-31 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-31 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2008-01-31 08:32:15 | | | | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|