Plan Review Details - Permit 08010656
| Plan Review Stops For Permit 08010656 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2009-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-06-15 |
Time |
11:31 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-06-15 |
Time |
11:31 |
Sent To |
PC |
|
| Notes |
| 2009-06-15 11:32:43 | REVISION: REVISED C-4, C-6 AND ADDED C-11 TO SCHEDULE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2009-04-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-09 |
Time |
09:28 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-04-09 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2009-04-09 09:30:41 | REVISION SUBMITTED (APRIL 1/09) SUBMITTED UNDER | | | 08010656 (FOUNDATION) SHOULD HAVE BEEN BROUGHT IN UNDER | | | 08050454 (SITE). TRANSFERRED OVER TO SITE PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-03-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-03-31 |
Time |
09:39 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2009-03-31 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2009-03-31 09:44:41 | REVISION # 1 DATED 03/24/09 S-1/S-8 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-07-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-07-21 |
Time |
10:23 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-07-21 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2008-07-21 10:25:00 | BUILDING PLAN REVIEW | | | PERMIT: 08010656 | | | ADD: 3415 S DIXIE HWY | | | CONT: R & D CONSTRUCTION, INC. | | | TEL: (561)889-1751 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: REVIEWED | | | | | | . | | | | | | 1) BUILDING PROVISO 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL | | | OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 2) BUILDING PROVISO 109.3.10.1 HURRICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS,EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 | | | OF THIS CHAPTER. | | | | | | 3) BUILDING PROVISO: 105.13. SPECIAL FOUNDATION PERMIT. | | | WHEN APPLICATION FOR A PERMIT TO ERECT OR ENLARGE A | | | BUILDING HAS BEEN FILED, & PENDING ISSUANCE OF SUCH | | | PERMIT, THE BUILDING OFFICIAL MAY, AT HIS/ HER | | | DISCRETION, ISSUE A SPECIAL PERMIT FOR THE FOUNDATION | | | ONLY, UPON WRITTEN REQUEST OF THE OWNER AND CONTRACTOR. | | | THE HOLDER OF SUCH A SPECIAL PERMIT IS PROCEEDING AT | | | HIS OR HER OWN RISK AND WITHOUT ASSURANCE THAT A PERMIT | | | FOR THE REMAINDER OF THE WORK WILL BE GRANTED AND THAT | | | CORRECTIONS WILL NOT BE REQUIRED IN ORDER TO MEET THE | | | PROVISIONS OF THE TECHNICAL CODE. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-21 |
Time |
09:12 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-04-21 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2008-04-21 09:18:23 | BUILDING PLAN REVIEW | | | PERMIT: 08010656 | | | ADD: 3415 S DIXIE HWY | | | CONT: R & D CONSTRUCTION, INC. | | | TEL: (561)889-1751 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B, INFORMATIONAL PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE | | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) INFORMATIONAL FL S S 713.13NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1E) INFORMATIONAL PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE2007 SUPPLEMENTS. | | | | | | 2) SECOND REQUEST, 2 REPORTS WERE SUBMITTED BUT THE | | | RAISED SEAL WERE COPIES OF SIGNATURES NOT ORIGINAL. | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. FL ADMIN | | | CODE 61G15-23.002 ENGINEERS | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING | | | POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING | | | VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS | | | CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE | | | NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION | | | SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4 | | | THROUGH 1802.6 . | | | | | | 3) COMPLIED. | | | | | | 4) BUILDING PROVISO 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL | | | OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 5) BUILDING PROVISO 109.3.10.1 HURRICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS,EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 | | | OF THIS CHAPTER. | | | | | | 6-9) COMPLIED. | | | | | | 10) BUILDING PROVISO: 105.13. SPECIAL FOUNDATION | | | PERMIT.WHEN APPLICATION FOR A PERMIT TO ERECT OR | | | ENLARGE A BUILDING HAS BEEN FILED, & PENDING ISSUANCE | | | OF SUCH PERMIT, THE BUILDING OFFICIAL MAY, AT HIS/ HER | | | DISCRETION, ISSUE A SPECIAL PERMIT FOR THE FOUNDATION | | | ONLY, UPON WRITTEN REQUEST OF THE OWNER AND CONTRACTOR. | | | THE HOLDER OF SUCH A SPECIAL PERMIT IS PROCEEDING AT | | | HIS OR HER OWN RISK AND WITHOUT ASSURANCE THAT A PERMIT | | | FOR THE REMAINDER OF THE WORK WILL BE GRANTED AND THAT | | | CORRECTIONS WILL NOT BE REQUIRED IN ORDER TO MEET THE | | | PROVISIONS OF THE TECHNICAL CODE. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-02-12 |
Time |
20:45 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2008-02-12 |
Time |
20:45 |
Sent To |
|
|
| Notes |
| 2008-02-12 21:27:15 | BUILDING PLAN REVIEW | | | PERMIT: 08010656 | | | ADD: 3415 S DIXIE HWY | | | CONT: R & D CONSTRUCTION, INC. | | | TEL: (561)889-1751 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A | | | RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD | | | BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE | | | SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT | | | ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTSWEST PALM | | | BEACH ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE2007 SUPPLEMENTS. | | | | | | 2) 1802.2.1 QUESTIONABLE SOIL. WHERE THE | | | SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE | | | A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS | | | CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE | | | THAT THE NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 3) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | | OF OCCUPANCY: | | | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT | | | IS DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, | | | TABLE 601. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED F) | | | WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE | | | BUILDING PERMIT | | | | | | 4) 109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | | AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | | INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, | | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 5) 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE | | | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED | | | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. | | | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS,EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 | | | OF THIS CHAPTER. | | | | | | 6) SITE PLAN INDICATES A HANDICAPPED PARKING SPACE BUT | | | NOT A ACCESSIBLE ACCESS AISLE | | | 5?-0? WIDE. SEE 11-4.6.3. | | | | | | 7)THE PERMIT APPLICATION INDICATES THIS IS TO BE FOR | | | FOUNDATION ONLY, WOULD THE PERMIT ALSO NEED TO INCLUDE | | | STEM WALL ABOVE THE SLAB FOR BACKFILL AND GRADING | | | PURPOSES? | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9) STATE RADON FEES ARE GOING TO NEED TO BE PAID IN THE | | | AMOUNT OF $199.80 AT THE CITY?S CASHIER DESK BEFORE | | | PERMIT ISSUANCE. | | | | | | 10) BUILDING PROVISO: 105.13. SPECIAL FOUNDATION | | | PERMIT.WHEN APPLICATION FOR A PERMIT TO ERECT OR | | | ENLARGE A BUILDING HAS BEEN FILED, & PENDING ISSUANCE | | | OF SUCH PERMIT, THE BUILDING OFFICIAL MAY, AT HIS/ HER | | | DISCRETION, ISSUE A SPECIAL PERMIT FOR THE FOUNDATION | | | ONLY, UPON WRITTEN REQUEST OF THE OWNER AND CONTRACTOR. | | | THE HOLDER OF SUCH A SPECIAL PERMIT IS PROCEEDING AT | | | HIS OR HER OWN RISK AND WITHOUT ASSURANCE THAT A PERMIT | | | FOR THE REMAINDER OF THE WORK WILL BE GRANTED AND THAT | | | CORRECTIONS WILL NOT BE REQUIRED IN ORDER TO MEET THE | | | PROVISIONS OF THE TECHNICAL CODE. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | NOTE: 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT | | | SECTIONS OF THIS CODE SPECIFY DIFFERENT MATERIALS, | | | METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE | | | APPLICABLE. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-24 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-24 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-07 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-07 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2008-04-07 14:47:51 | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEW ARE STILL IN | | | NEED OF ADDRESSING. | | | | | | 1) NOTE: PLEASE SUBMIT ELECTRICAL PLANS/DETAIL FOR THE | | | REQUESTED FOUNDATION PERMIT SCOPE OF WORK. | | | PLEASE SEE 250.50 AS THE FOOTER STEEL IS REQUIRED TO BE | | | PART OF THE GROUNDING ELECTRODE SYSTEM. | | | RESPONSE LETTER FROM ARCHITECT MENTIONS TO SEE PLANS | | | WHICH WILL PART OF THE MAIN BUILDING PERMIT HOWEVER THE | | | FOUNDATION STEEL IS PART OF THE SCOPE OF WORK FOR THIS | | | PERMIT AND ELECTRICAL PLANS/DETAILS ARE REQUIRED. | | | PLEASE SEE THE LETTER FROM THE ENGINEERING FIRM TEELE | | | AND ASSOCIATES DOES NOT PROVIDE THE REQUIRED PLANS. | | | THIS LETTER MAKES REFERENCE TO THE NEC AND 250.66B AND | | | 250.70 WITHOUT ACTUALLY SUBMITTING ANY PLANS. THE | | | SHEETS ATTACHED TO THE LETTER ARE NOT FROM THE NEC/ | | | NFPA-70 2005. | | | PLEASE ALSO KNOW THE CODE SECTION AS REFERENCE IN | | | LETTER ONLY APPLIES IN CERTAIN CIRCUMSTANCES. THE | | | SIZING OF THE GROUNDING ELECTRODE CONDUCTOR IS STILL | | | REQUIRED TO MEET 250.66. | | | PLEASE SUBMIT MINIMUM PLANS AS PREVIOUSLY NOTED. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 2) NOTE: *** IMPORTANT *** | | | PLEASE KEEP IN MIND AS SLAB WORK APPEARS TO BE PART OF | | | THE PROPOSED FOUNDATION, ANY SLAB CONDUITS FOR | | | ELECTRICAL WOULD NEED TO BE SHOWN ALSO AT THIS TIME. IF | | | SLAB WORK WILL NOT CONTAIN ANY SLAB CONDUITS FOR ITEMS | | | SUCH AS FLOOR BOXES, FEEDERS ETC THEN THIS WILL NOT BE | | | NEEDED. | | | *** | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-31 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-31 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2008-01-31 16:25:52 | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SEE THE PERMIT APPLICATION MENTIONS | | | PLANS AND SCOPE OF WORK FOR NEW BUILDING PREVIOUSLY | | | SUBMITTED. PLEASE KNOW HOWEVER THE SCOPE OF WORK WAS | | | FOR COMMERCIAL REMODEL ON PLANS APPLIED IN DEC 06 WAS | | | NOT FOR A NEW BUILDING. | | | PLEASE ALSO SEE THAT APPLIED PERMIT HAS ALSO ALREADY | | | EXPIRED. | | | | | | 2) NOTE: PLEASE SUBMIT GROUNDING ELECTRODE DETAIL FOR | | | FOUNDATION AND ATTACHMENT(S) TO NEW FOOTER STEEL. | | | 250.50, 250.66. | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-02-27 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-02-27 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2008-02-27 09:41:37 | ***FOUNDATION ONLY*** | | | | | | NO LINES ASSOCIATED WITH FIRE PROTECTION EQUIPMENT | | | SHALL RUN OR EXTEND BENEATH ANY PORTION OF THE | | | FOUNDATION THAT WOULD IMPACT ABILITY TO REPAIR SYSTEM | | | IF NEEDED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-06-03 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-06-03 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2009-06-03 16:09:41 | REVISION SENT TO JIM WITMER'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-06-03 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-06-03 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2009-06-03 11:22:28 | TEMP. CONSTRUCTION FENCE REVISION SENT TO ZONING. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-04-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-03 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-03 |
Time |
09:06 |
Sent To |
Z |
|
| Notes |
| 2009-04-03 09:11:20 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-04-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-03 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-03 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2009-04-03 09:03:38 | TO "C3" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-03-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-18 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-18 |
Time |
16:50 |
Sent To |
B |
|
| Notes |
| 2009-03-18 16:51:22 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-07-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-17 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-17 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2008-07-17 14:28:52 | TO "COMM" BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-04-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-02 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-02 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2008-04-02 15:49:51 | TO "COMM" BD#23 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-02-27 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-28 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2008-01-29 10:56:17 | 1/29/08--TO "COMM" BD#42 | | 2008-01-28 15:56:24 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-24 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-24 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2008-07-24 11:48:28 | ****************PROVISO**************** | | | PER CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION | | | *105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL OF THE | | | APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF THE FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER'S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODE. | | | NOTE: THE FOLLOWING FIXTURES SHALL BE COMPLIANT WITH | | | THE FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE ALL | | | SECTIONS. | | | A} WATER COOLERS= 11-4.15. | | | B} WATER CLOSET= SECTION 11-4.16. | | | C} LAVATORIES= SECTION 11-4.19. | | | D} SINKS= 11-4.24. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-11 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-11 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2008-04-11 11:00:22 | PLUMBING PLAN REVIEW: | | | DENIED 2ND TIME | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | THE PREVIOUS PLUMBING PLAN REVIEW COMMENTS AS WELL AS | | | THE DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | NEW COMMENTS WILL BE SO NOTED FOLLOWING THE PREVIOUS | | | PLUMBING REVIEW COMMENTS. | | | | | | 1. **OK** COMMENT ADDRESSED, LETTERS HAVE BEEN | | | FORWARDED TO KEN CONRAD CHIEF BUILDING INSPECTOR. | | | | | | 2. SHEET S1 IS INDICATING A BATHROOM WITH A WATER | | | CLOSET AND LAVATORY AND SHEET S-1 IS INDICATING A 4" | | | SLAB-ON-GRADE. IS IT THE INTENTOF THIS FOUNDATION | | | PERMIT TO POUR THE SLAB ON GRADE WITHOUT THE | | | UNDERGROUND PLUMBIMG BEING INSTALLED. PLEASE CLARIFY | | | PER CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION | | | 106.1.2 ADDITIONAL DATA REQUIRED. | | | **RESONSE NOTED AND REVIEW OF THE NEW ATTACHED | | | PLUMBING SHEETS WILL BE UNDER NEW COMMENTS. | | | | | | 3. **PLUMBING PROVISO** PER CITY OF WPB AMENDMENTS TO | | | CHAPTER 1, SECTION *105.13 PHASED PERMIT APPROVAL. | | | AFTER SUBMITTAL OF THE APPROPRIATE CONSTRUCTION | | | DOCUMENTS, THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE | | | A PERMIT FOR THE CONSTRUCTION OF THE FOUNDATIONS. THE | | | HOLDER OF SUCH PERMIT FOR THE FOUNDATION SHALL PROCEED | | | AT THE HOLDER'S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY REQUIRED TO | | | MEET THE REQUIREMENTS OF THE TECHNICAL CODE. | | | **RESPONSE NOTED. | | | | | | THE FOLLOWING ARE NEW COMMENTS. | | | | | | 4. SHEET C1 USE AND OCCUPANCY CLASSIFICATION IS | | | INDICATING ON THE FIRST AND SECOND LEVEL THAT MODERATE | | | HAZARD STORAGE IS IN GROUP S-1. WHAT TYPES AND QUANTITY | | | OF HAZARDOUS MATERIALS ARE GOING TO BE STORED? PER | | | (W.P.B.) SECTION 106.1.2 ADDITIONAL DATA AND FBC | | | PLUMBING SECTION 411 EMERGENCY SHOWER AND EYEWASH | | | STATIONS MAY BE REQUIRED. | | | | | | 5. SHEET P1.1 INDICATES FOUR SEPERATE RETAIL SPACES. | | | PLEASE CLARIFY IF THE RETAIL SPACES HAVE ONE OWNER OR | | | IF THERE ARE FOUR SEPERATE OWNERS. PER FBC PLUMBING | | | SECTION 403.6 PUBLIC FACILITIES.CUSTOMERS, PATRONS AND | | | VISITORS SHALL BE PROVIDED WITH PUBLIC TOILET | | | FACILITIES IN STRUCTURES AND TENANT SPACES INTENDED FOR | | | PUBLIC UTILIZATION. PUBLIC TOILET FACILITIES SHALL BE | | | LOCATED NOT MORE THAN ONE STORY ABOVE OR BELOW THE | | | SPACE REQUIRED TO BE PROVIDED WITH PUBLIC TOILET | | | FACILITIES AND THE PATH OF TRAVEL TO SUCH FACILITIES | | | SHALL NOT EXCEED A DISTANCE OF 500 FEET (152 M). | | | | | | 6. SHEET P1.1 THE STORM DRAIN REQUIRES A TWO-WAY | | | CLEANOUT OUTSIDE OF THE BUILDING. PER FBC PLUMBING | | | SECTION 1101.8 CLEANOUTS REQUIRED (SECTION 708.3.5 ). | | | | | | 7. SHEET P3.1 PLEASE CLARIFY IF THERE ARE PARAPET | | | WALLS AND IF SO WHAT ARE THE CALCULATIONS? PER FBC | | | PLUMING SECTION 1106.4 VERTICAL WALLS. | | | | | | 8. SHEET P3.2 THE SQUARE FOOTAGE FOR RD-1 AND RD-2 | | | APPEARS LOW. MY CALCULATIONS COME TO 2517.5 SQ. FT. FOR | | | RD-1 AND 2052 SQ. FT. FOR RD-2 AND THATS NOT | | | CALCULATING IF THERE ARE PARAPET WALLS. PER FBC | | | PLUMBING SECTION 1101.1 SCOPE AND 1106.4 VERTICAL | | | WALLS. | | | | | | 9. SHEET P4.1 PLUMBING SPECIFICATIONS (2) CODES AND | | | STANDARDS (A) THE CODE STANDARDS REFERENCED ARE NOT | | | COMPLIANT PLEASE DELETE THOSE CODE REFERENCE STANDARDS | | | AND ADD IN ITS PLACE "FBC-2004 WITH 2007 REVISIONS". | | | | | | 7. SHEET P4.1 PLUMBING SPECIFICATIONS (5) MATERIALS | | | (F) AIR CHAMBERS ARE NOT APPROVED BY FBC PLUMBING | | | SECTION 604.9 WATER HAMMER. HOWEVER IF IT IS THE INTENT | | | TO USE AIR CHAMBERS THEY SHALL BE INSTALLED PER | | | "STANDARD PDI-WH 201 RECHARGEABLE TYPE AIR CHAMBER. A | | | DETAIL OF THIS TYPE OF AIR CHAMBER IS REQUIRED ON PLANS | | | OR DELETE AIR CHAMBERS ON THE RESUBMITTAL. | | | | | | 8. SHEET P4.1 SANITARY RISER A CLEANOUT IS REQUIRED AT | | | THE BASE OF THE STACK ON RISER S-1, PER FBC PLUMBING | | | SECTION 708.3.4 AND A TWO-WAY CLEANOUT IS REQUIRED AT | | | THE JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER, | | | PER FBC PLUMBING SECTION 708.3.5. | | | | | | 9. SHEET P4.2 STORM RISERS CLEANOUTS ARE REQUIRED AT | | | THE BASE OF THE VERTICAL STORM LEADERS, PER 1101.8 | | | (708.3.4) AND A TWO-WAY CLEANOUT IS REQUIRED ON THE | | | HORIZONTAL STORM DRAINAGE PIPE OUTSIDE OF THE BUILDING, | | | PER FBC PLUMBING 1101.8 (708.3.5). | | | | | | 10. SHEET P4.2 STORM RISERS: THE STORM RISERS WERE | | | REVIEWED PER MINIMUM REQUIREMENTS PER FBC PLUMBING | | | TABLE 1106.3 SLOPE OF 1/8 INCH PER FOOT (1-PERCENT). IF | | | IT IS THE INTENT OF THE DESIGNER TO USE OTHER SLOPE | | | REQUIREMENTS IT MUST BE CLEARLY INDICATED ON THE PLANS. | | | PLEASE CORRECT ALL MAIN UNDERGROUND HORIZONTAL STORM | | | DRAINAGE PIPING SIZES FOR THE ROOF DRAINS. PLEASE | | | CORRECT THE FOLLOWING BRANCHES TO THE ABOVE GROUND | | | HORIZONTAL STORM DRAINAGE PIPE TO RD-1, RD-2, RD-3, AND | | | RD-5. PLEASE CORRECT ALL MAIN ABOVE GROUND HORIZONTAL | | | STORM DRAINAGE PIPE SIZES FOR THE EMERGENCY DRAINS. | | | PLEASE CORRECT THE FOLLOWING BRANCHES TO THE ABOVE | | | GROUND HORIZONTAL STORM DRAINAGE PIPE TO ED-3, AND | | | ED-5. PER FBC PLUMBING TABLE 1106.3 (1-PERCENT SLOPE). | | | | | | | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-02-19 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-02-15 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2008-02-15 16:58:03 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. NOTE: THERE ARE TWO EXPIRED PERMITS (PERMIT # | | | 06110395 & 06120401 BOTH FOR COM/REMOD) FOR THIS | | | ADDRESS BY R & D CONTRACTORS, INC. WHICH IS THE SAME | | | CONTRACTOR FOR THIS FOUNDATION PERMIT. THERE IS ALSO A | | | FULL DEMO PERMIT THAT HAS BEEN ISSUED FOR THIS ADDRESS | | | TO R & D CONTRACTORS, INC. IS THIS FULL DEMO PERMIT FOR | | | THE BUILDINGS INDICATED IN THE EXPIRED PERMITS. PLEASE | | | REFERENCE THE PERMIT INFORMATION SHEETS ATTACHED TO THE | | | PLUMBING COMMENTS INDICATING THIS. | | | **AN ORIGINAL NOTARIZED LETTER IS REQUIRED FROM R & D | | | CONTRACTORS, INC. VOIDING OUT THE EXPIRED PERMITS OF | | | 06110395 AND 06120401 EVEN IF THE BUILDINGS HAVE BEEN | | | DEMOED. | | | | | | 2. SHEET S1 IS INDICATING A BATHROOM WITH A WATER | | | CLOSET AND LAVATORY AND SHEET S-1 IS INDICATING A 4" | | | SLAB-ON-GRADE. IS IT THE INTENTOF THIS FOUNDATION | | | PERMIT TO POUR THE SLAB ON GRADE WITHOUT THE | | | UNDERGROUND PLUMBIMG BEING INSTALLED. PLEASE CLARIFY | | | PER CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION | | | 106.1.2 ADDITIONAL DATA REQUIRED. | | | | | | 3. **PLUMBING PROVISO** PER CITY OF WPB AMENDMENTS TO | | | CHAPTER 1, SECTION *105.13 PHASED PERMIT APPROVAL. | | | AFTER SUBMITTAL OF THE APPROPRIATE CONSTRUCTION | | | DOCUMENTS, THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE | | | A PERMIT FOR THE CONSTRUCTION OF THE FOUNDATIONS. THE | | | HOLDER OF SUCH PERMIT FOR THE FOUNDATION SHALL PROCEED | | | AT THE HOLDER'S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY REQUIRED TO | | | MEET THE REQUIREMENTS OF THE TECHNICAL CODE. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2009-06-05 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-06-05 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-06-05 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2009-06-05 15:54:55 | ***PROVISO*** | | | | | | FABRIC SHALL BE NO LESS THAN 85 PERCENT OPAQUE AND | | | COVER ENTIRE FENCE. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435 | | | WITH QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-04-07 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-04-07 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2009-04-07 09:34:13 | ***FAILED*** | | | | | | TEMPORARY FENCE REVISION SUBMITTED 4/1/09 | | | | | | 1. THE TEMPORARY FENCE SHALL MEET ALL REQUIREMENTS | | | FOUND WITHIN SEC. 94-450(E)(2) WHICH I HAVE INCLUDED IN | | | THE PERMIT PACKAGE. TAKE SPECIAL NOTE OF SUB PARAGRAPH | | | 5 WHICH REQUIRES SCREENING MATERIAL TO BE ATTACHED TO | | | THE FENCE. | | | | | | 2. AS SHOWN, THE FENCE IS LOCATED WITHIN THE VISIBILITY | | | TRIANGLE. ENSURE THAT THE CORNERS OF THE PROPERTY ARE | | | NOT OBSTRUCTED. I HAVE INCLUDED A COPY OF THE VISIBLITY | | | REQUIREMENTS IN THE PERMIT PACKAGE FOR YOUR REFERENCE. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458 | | | OR [email protected] WITH QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-07-22 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-07-22 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-04-08 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-04-08 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-01-29 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-01-29 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2008-01-29 10:28:14 | ***FAILED*** | | | | | | 1. AS DISCUSSED BY PHONE, ZONING WILL BE UNABLE TO | | | APPROVE PERMIT UNTIL THE PENDING EASEMENT ABANDONMENTS | | | HAVE BEEN ACTED UPON BY THE CITY COMMISSION. THIS IS | | | SCHEDULED FOR THE FEBRUARY 11, 2008, AGENDA. | | | | | | 2. PLEASE PROVIDE TWO SIGNED AND SEALED SURVEYS WITH | | | THE RESUBMITTAL. | | | | | | 3. PLEASE REVISE SHEET S-1 TO SHOW PROPERTY LINES AND | | | BUILDING SETBACKS. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458 | | | OR [email protected] WITH QUESTIONS. |
|
|
|