| 2008-02-12 16:16:37 | |
| | PROJECT: 249 ASHWORTH ROAD/#08010647 |
| | |
| | CODE REVIEW: |
| | 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS |
| | 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS |
| | CITY OF WEST PALM BEACH AMENDMENTS 2004 EDITION |
| | |
| | STATUS: FAILED |
| | |
| | COMMENTS: |
| | |
| | 1) PLEASE PROVIDE THE DESIGN PARAMETERS AS PER THE |
| | FOLLOWING: |
| | |
| | FLORIDA EXISTING BUILDING CODE, SECTION 407.3.1 NEW |
| | STRUCTURAL FRAME MEMBERS. |
| | NEW STRUCTURAL FRAME MEMBERS USED IN THE REPAIR OF |
| | DAMAGED BUILDINGS, INCLUDING ANCHORAGE AND CONNECTIONS, |
| | SHALL COMPLY WITH THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | FLORIDA BUILDING CODE |
| | 1603.1.4 WIND DESIGN DATA. |
| | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| | BUILDING: |
| | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| | (KM/HR). |
| | 2. WIND IMPORTANCE FACTOR, IW, AND BUILDING |
| | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| | DIRECTION SHALL BE INDICATED. |
| | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| | IN TERMS OF PSF (KN/M2) TO BE USED FOR THE SELECTION OF |
| | EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| | PROFESSIONAL. |
| | |
| | 2) PLEASE SUBMIT A FLOOR PLAN INDICATING THE NUMBER OF |
| | WINDOW OPENINGS, DIMENSIONS, AND DESIGN PRESSURES. |
| | |
| | 3) PLEASE INDICATE WHETHER THE WOOD TRUSSES SHOWN ON |
| | DETAIL #2 ARE EXISTING OR NEW. |
| | |
| | 4) PLEASE PROVIDE PRODUCT APPROVALS FORNEW FRAMING |
| | MEMBER STRAPS AND ANCHORS AS PER THE FOLLOWING: |
| | |
| | 9B-72.005 SCOPE. |
| | (1) PRODUCTS IN THE FOLLOWING CATEGORIES AS DEFINED BY |
| | SUBCATEGORIES OF SUBSECTION 9B-72.010(31), F.A.C., |
| | SHALL BE AVAILABLE FOR |
| | APPROVAL BY THE COMMISSION PURSUANT TO RULE 9B-72.090, |
| | F.A.C., FOR USE IN THE STATE: |
| | (A) PANEL WALLS; |
| | (B) EXTERIOR DOORS; |
| | (C) ROOFING PRODUCTS; |
| | (D) SKYLIGHTS; |
| | (E) WINDOWS; |
| | (F) SHUTTERS; AND |
| | (G) STRUCTURAL COMPONENTS. |
| | (2) THIS RULE APPLIES TO APPROVAL OF PRODUCTS AND |
| | SYSTEMS, WHICH COMPRISE THE BUILDING ENVELOPE AND |
| | STRUCTURAL FRAME, FOR |
| | COMPLIANCE WITH THE STRUCTURAL REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE. |
| | SPECIFIC AUTHORITY 553.842(1) FS. LAW IMPLEMENTED |
| | 553.842(5) FS. HISTORY?NEW 11-22-06. |
| | |
| | 5) PLEASE COMPLETE AND SUBMIT SHUTTER INSTALLATION |
| | SCHEDULE FORM. |
| | |
| | PLAN REVIEW: KEN CONRAD |
| | PHONE: 561.805.6666 |
| | E-MAIL: KCONRAD @WPB.ORG |
| | |
| | |