Plan Review Details - Permit 08010582
| Plan Review Stops For Permit 08010582 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-03-19 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-03-19 |
Time |
17:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-03-01 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-03-01 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-03-01 |
Time |
11:36 |
Sent To |
PC |
|
| Notes |
| 2008-03-01 11:44:39 | | | | | | | PASSED | | | | | | ******PLEASE NOTE THAT NOTE #4 FROM FIRST REVIEW WAS | | | NOT COMPLETELY ADDRESSED THE HGAM10 CONNECTOR IS A WOOD | | | TO MASONRY CONNECTOR MEANT TO BE ATTACHED TO TOP OF | | | BEAM (SEE ATTACHED INFO SHEETS) DRAWING SHOWS FLUSH | | | MOUNTED JOISTS. REVISE DRAWING NOTES FOR CORRECT JOIST | | | HANGER (LUS26 OR HUS26 WOULD WORK AND ARE IN THE | | | SUBMITTED PRODUCT APPROVAL ON PAGES 11-13) | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-01-31 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-01-31 |
Time |
16:19 |
Sent To |
PC |
|
| Notes |
| 2008-01-31 16:52:30 | | | | | | | DENIED | | | | | | | | | 1)CONSTRUCTION DOCUMENTS SHALL SHOW THE SIZE, SECTION | | | AND RELATIVE LOCATIONS OF STRUCTURAL MEMBERS WITH FLOOR | | | LEVELS, COLUMN CENTERS AND OFFSETS FULLY DIMENSIONED. | | | THE DESIGN LOADS AND OTHER INFORMATION PERTINENT TO THE | | | STRUCTURAL DESIGN REQUIRED BY SECTIONS 1603.1.1 THROUGH | | | 1603.1.8 SHALL BE CLEARLY INDICATED ON THE CONSTRUCTION | | | DOCUMENTS FOR PARTS OF THE BUILDING OR STRUCTURE, PER | | | 1603.1 FBC.(WIND LOADS, FLOOR LOADS, | | | SOIL BEARING PRESSURE AND DESIRED SOIL DENSITY FOR | | | FOUNDATIONS, ETC.) | | | | | | 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | | DRAWINGS | | | | | | 3)MORE INFORMATION IS REQUIRED: | | | A) SHOW LOCATION OF WORK IN RELATION TO ENTIRE | | | BUILDING | | | B) IS THEIR AN EXISTING FOUNDATION UNDER 8" CBS WALL | | | AND IF SO IS THE 30"X30" PAD ATTACHED OR UNDERNEATH | | | EXISTING | | | C) WILL BEAM SET ON CBS WALL, IN A POCKET OR AS NOTE | | | STATES ON A 4X4 COLUMN | | | D) PROVIDE CORRECT ADDRESS ON DRAWINGS | | | | | | 4)PROVIDE PRODUCT APPROVALS FOR SIMPSON TIES. PLEASE | | | NOTE THAT HGMA10 IS A WOOD TO MASONRY/CONCRETE | | | APPLICATION AND YOUR JOIST TO BEAM IS AN ALL WOOD | | | CONDITION | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-14 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-14 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2008-03-14 11:12:34 | TO "AMORSE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-27 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-27 |
Time |
09:03 |
Sent To |
B |
|
| Notes |
| 2008-02-27 09:03:29 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-01-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-25 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2008-01-25 09:56:45 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-28 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-28 |
Time |
11:02 |
Sent To |
B |
|
| Notes |
| 2008-01-28 11:03:20 | ***ZONING REVIEW - NOT REQUIRED - INTERIOR SUPPORT BEAM | | | ONLY.*** | | | | | | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|