Plan Review Details - Permit 08010557
Plan Review Stops For Permit 08010557
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-05-28 Cont ID  
Sent By lmartine Date 2008-05-28 Time 11:15 Rev Time 0.00
Received By lmartine Date 2008-05-28 Time 11:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-24 Cont ID  
Sent By shill Date 2008-01-24 Time 10:09 Rev Time 0.00
Received By shill Date 2008-01-24 Time 10:09 Sent To  
Notes
2008-01-24 10:09:58****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER BARRIER
 REQUIRED FS553.844(5)(A). PROVIDE INFORMATION
 (PRODUCT APPROVAL OR SPECIFICATIONS) TO SHOW HOW YOU
 WILL COMPLY WITH THIS REQUIREMENT.INFORMATION IS
 AVAILABLE AT WWW.BOAF.NET, HURRICANE MITIGATION.
  
 2.)DOUBLE UNDERLAYMENT REQUIRED FOR SLOPE LESS THAN
 4:12, FBC1507.2.8.PLEASE REVISE THE APPLICATION OR
 PROVIDE A LETTER TO INDICATE HOW YOU ARE GOING TO
 COMPLY WITH THIS REQUIREMENT.
  
 3.)PLEASE CLARIFY SQUARE FOOT AREA ON THE
 APPLICATION.YOU STATE THAT THIS IS 1200 SQUARE FEET;
 ARE YOU DOING THE ENTIRE ROOF OR ONLY A PORTION?
 PROVIDE A ROOF PLAN IF NECESSARY TO DETERMINE SCOPE OF
 WORK.PAPA SHOWS THIS STRUCTURE AS 1522 SQUARE FEET,
 SO ROOF AREA SHOULD BE GREATER (WITH SLOPE AND
 OVERHANGS).
  
  