| Plan Review Stops For Permit 08010526 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-03-07 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-03-07 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-01-30 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-01-30 |
Time |
08:17 |
Sent To |
PC |
|
| Notes |
| 2008-01-30 08:17:58 | PLEASE CLARIFY THE LOCATION JOB ,WHICH TOWER EAST OR | | | WEST AND THE SUITE NUMBER . | | | | | | | | | QUESTIONS/COMMENTS: | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-02 |
Time |
11:10 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-06 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-03-06 |
Time |
12:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-01-30 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-01-30 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2008-01-30 14:41:05 | | | | THE DRAWINGS SEEMS TO BE OK AT THIS TIME OF REVIEW. | | | UNTIL A CONTRACTOR IS HIRED AND A VALUE IS INDICATED | | | THE PLANS WILL HAVE A 'FAILED' STATUS. THE VALUE OF THE | | | PROJECT SHALL ALSO BE INDICATED. | | | INDICATE THE SUITE /UNIT NUMBER ON THE APPLICATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-29 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-29 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-05 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-05 |
Time |
12:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-29 |
Time |
20:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-29 |
Time |
20:06 |
Sent To |
|
|
| Notes |
| 2008-01-29 20:06:53 | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE KNOW PLANS HAVE ONLY BEEN SUBMITTED FOR | | | *PLAN REVIEW * ONLY AND HAVE NOT BEEN SUBMITTED FOR | | | PERMIT AT THIS TIME. | | | PLEASE KNOW EVEN ONCE PLANS ARE CODE COMPLIANT MEETING | | | COMMENTS FROM REVIEWER(S), PLANS WILL NOT BE STAMPED | | | AND REVIEW WILL REMAIN IN A FAILED STATUS UNTIL PERMIT | | | APPLICATION HAS BEEN MADE. | | | | | | 2) NOTE: PLEASE KNOW THE ADDRESSING FOR UNIT/SUIT IS | | | YET TO BE DETERMINED. PLEASE KNOW AS THIS IS AN | | | EXTENSION TO AN EXISTING TENANT PLEASE OBTAIN EXISTING | | | SUITE/UNIT NUMBER AND CONFIRM WITH THIS OFFICE AND | | | ADDRESSING REVIEWER. PLEASE KNOW THE INFORMATION WAS | | | SENT TO THE ADDRESSING REVIEWER AS OF THIS REVIEW. | | | PLEASE BE SURE ALL TITLE BLOCKS CONTAIN THE ADJUSTED | | | SUITE/UNIT LOCATION ONCE DETERMINED. | | | PLEASE SEE LOCATION FOR EAST OR WEST TOWER LOCATION | | | ALSO NEEDS TO BEAPPLIED. | | | FBC 106.5, 106.1.2 ADMIN SECTION. | | | FAC 61G15-23.002, 61G1-16.002 | | | | | | 3) NOTE: PLEASE SEE THE COLOR CODING AS STATED ON PLANS | | | FOR 277/480V SYSTEMS SHALL BE BROWN, PURPLE, YELLOW. | | | THE *ORANGE* COLOR AS SPECIFIED ON THE PLANS IS FOR A | | | DELTA HIGH-LEG SYSTEM WHICH THIS IS NOT. | | | THIS WAS A LOCAL AMENDMENT FOR THIS AND OTHER LOCAL | | | JURISDICTIONS AND WIRING METHOD IN THIS AND OTHER | | | EXISTING BUILDING CONTAIN THE COLOR CODING AS MENTIONED | | | ABOVE. | | | THIS REMAINS A REQUIREMENT PER 90.4 DUE TO EXISTING | | | WIRING METHODS FOR SAFETY. | | | | | | 4) NOTE: PLEASE SEE THE METHOD *B* ENERGY CALCULATIONS | | | SUBMITTED DO NOT CONTAIN THE INPUT DATA REPORT(S) IN | | | ANY OF THE THREE COPIES SUBMITTED. | | | PLEASE SEE SHEET #2 OF THE SUMMARY AS THIS SPECIFICALLY | | | STATES THE INPUT DATA REPORT MUST ACCOMPANY | | | CALCULATIONS. | | | PLEASE KNOW AS THERE WERE NOT SUBMITTED NO REVIEW OF | | | THE ITEMS ON THE IDR CAN BE DONE AND COORDINATED WITH | | | THE SUBMITTED PLANS AND FIXTURE LEGEND. | | | PLEASE SEE THE CERTIFICATION SHEET IS REQUIRED TO BE | | | SEALED BY THE DESIGN PROFESSIONAL OF RECORD. THE SHEET | | | WAS SIGNED, AND DATED HOWEVER DID NOT GET SEALED. | | | PLEASE ALSO SEE THE OWNER AGENT SIGNATURE IS MISSING ON | | | THIS SAME SHEET. | | | 13-415.1.B, 13-415.2, 13-103.1, 13-103.1.1, | | | 13-103.1.1.1 | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEW TRADES. | | | | | | 5) NOTE: PLEASE STATE MAXIMUM TIMES ON ALL OCCUPANCY | | | SENSOR TYPE DEVICES PER 13-415.1.ABC.1.1, .1.2. | | | | | | 6) NOTE: PLEASE SEE NOTE ON E.02 MENTIONS RELOCATION OF | | | THE TRANSFORMER. PLEASE SHOW AND INDICATE THE GROUNDING | | | ELECTRODE CONDUCTOR WHICH WILL MOST LIKELY BE REQUIRED | | | TO BE NEW DUE TO RELOCATION. | | | PLEASE SEE 250.66, 250.50, 250.30, 250.50 | | | | | | | | | | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-05-21 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-05-21 |
Time |
15:51 |
Sent To |
M |
|
| Notes |
| 2008-05-21 15:52:57 | WORK TO COMPLY WITH UL 555 REQUIREMENTS. FIRE DAMPER | | | SHALL BE TESTED FOR CLOSURE PRIOR TO FINAL INSPECTION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-30 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-30 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2008-04-30 11:11:50 | REVISION TO FP.01 REMOVED (1) SHEET FOR FILES |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-05 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-05 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2008-03-05 16:27:52 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | | ADDRESSED;PLAN SHEETS A0.03, A2.09, A4.09, A5.09, | | | FP.01, AND E.02 WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-06 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-06 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2008-02-06 16:22:21 | *****DENIED***** | | | | | | | | | 1.THE SUITE NUMBER SHALL BE INCLUDED WITH THE | | | NUMERICAL ADDRESS LOCATED IN THE TITLE BLOCK OF EACH | | | SUBMITTED PLAN SHEET. ALSO INDICATE EAST OR WEST | | | TOWER. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | | COMMENT TO SHEET AD1.09 | | | | | | 3.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 4.SPECIFY THE INTERIOR FINISH MATERIAL FOR THE WALL | | | AND CEILING IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 5.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE | | | EXTINGUISHER(S) WHICH SATIFIES THE 75' TRAVEL | | | DISTANCE. | | | | | | 6.INDICATE AS TO WHETHER THERE HAS BEEN ANY | | | ALTERATION TO FIRE ALARM DEVICES SHOWN ON SHEET E.02 IN | | | THE POWER & MISC. SYSTEMS PLAN.BE ADVISED THAT | | | SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE FIRE | | | ALARM REMODEL, | | | | | | 7.NFPA 13, STANDARD FO THE INSTALLATION OF SPRINKLER | | | SYSTEMS, 2002 EDITION SHALL BE REFERENCED.AMEND NOTE | | | #12 ON SHEET FP.01 | | | | | | 8.FLORIDA FIRE PREVENTION CODE 2004 EDITION SHALL BE | | | REFERENCED.AMEND NOTE #13 ON SHEET FP.01 | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-09 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-09 |
Time |
15:30 |
Sent To |
M |
|
| Notes |
| 2008-06-09 15:30:26 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-14 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-14 |
Time |
11:26 |
Sent To |
FIRE |
|
| Notes |
| 2008-05-14 11:27:09 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-22 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-22 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2008-04-22 14:13:26 | TO "BOB"#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-04 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-04 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2008-03-04 10:35:38 | TO "BOB"#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-06 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-01-24 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2008-01-24 11:58:54 | TO "BOB"#2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-06-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-10 |
Time |
11:07 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-06-10 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2008-06-10 11:08:09 | RECIVED REVISION SHEET SKM-1 DATED 6-5-08. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-22 |
Time |
08:45 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-05-22 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2008-05-22 08:47:12 | REVISION RECIVED SHEET NO. SKM-1 AND SKM-2. DATED | | | 5-2-08 (TRANSFRE DUCT WITH FIRE DAMPER). |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-24 |
Time |
10:36 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-24 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2008-04-24 10:36:47 | REVISION TO MECH. PLAN M.02. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-05 |
Time |
11:43 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-03-05 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-25 |
Time |
09:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-01-25 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2008-01-25 09:37:28 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | FOR PLAN REVIEW ONLY NOT FOR PERMIT. | | | | | | 1) MECHANICAL PLANS ARE OK AT THIS TIME. WILL NEED TO | | | HAVE A LICENSED CONTRACTOR SUBMIT A PERMIT | | | APPLICATION. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-04 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-04 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2008-03-04 13:45:59 | *ZONING REVIEW NOT REQUIRED; INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-28 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-28 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|