Plan Review Details - Permit 08010447
| Plan Review Stops For Permit 08010447 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-02-25 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-02-25 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-02-12 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-02-12 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2008-02-12 09:13:58 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.THE SHUTTER CONNECTION MOUNTING TYPE SHOULD | | | CORRELATE WITH THE ANCHOR CHARTS IN THE PRODUCT | | | APPROVAL; IN THIS CASE, C1 THROUGH C5.NOTE THAT THE | | | 12" SPACING SPECIFIED IS COMPLIANT FOR SOME CONNECTION | | | DETAILS BUT NOT ALL.MOUNTING ON THE DETAILS ON THE | | | PRODUCT APPROVAL WERE ALSO NOT MARKED.CODE COMPLIANCE | | | CANNOT BE DETERMINED BASED ON THE INFORMATION | | | PROVIDED. | | | | | | 2."SOLID SET ANCHOR BOLT" WAS WRITTEN IN THE COLUMN | | | FOR SHUTTER MOUNTING CONNECTION TYPE; THIS INFORMATION | | | SHOULD BE IN THE "SPECIFIC ANCHOR TYPE" COLUMN. | | | | | | 3.PLEASE REVISE THE PERMIT VALUATION TO INCLUDE THE | | | SHUTTERS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-02-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-02-04 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-02-04 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2008-02-04 09:30:23 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | FROM PREVIOUS LIST: | | | | | | 1.ADDRESSED. | | | | | | 2.PROVIDE TWO COMPLETE COLLATED SETS OF DOCUMENTS FOR | | | PERMIT ISSUANCE. | | | | | | DUE TO WORKLOAD, CONTRACTORS ARE REQUIRED TO PROVIDE | | | TWO COMPLETE COLLATED SETS OF PERMIT DOCUMENTS.ONLY | | | ONE FLOOR PLAN WAS SUBMITTED. | | | | | | NEW COMMENT: | | | | | | 3.THE INSTALLATION SCHEDULE IS INCOMPLETE.PLEASE | | | INCLUDE EDGE DISTANCE AND SHUTTER MOUNTING CONNECTION | | | TYPE.WITHOUT THIS INFORMATION, CODE COMPLIANCE CANNOT | | | BE DETERMINED. | | | | | | SEE THE HIGHLIGHTED PRODUCT APPROVAL.PLEASE INDICATE | | | WHICH OF THE FIVE ANCHORS YOU ARE USING.YOU'VE STATED | | | "STAINLESS"; AREN'T THEY ALL STAINLESS? | | | | | | CONNECTION MOUNTING TYPE SHOULD CORRELATE WITH THE | | | ANCHOR CHART ON SHEET 4; IN THIS CASE, THE CHOICES ARE | | | C1 THROUGH C5.NOTE THAT NOT ALL ANCHORS ARE PERMITTED | | | DEPENDING ON MOUNTING TYPE, ANCHOR TYPE, EDGE DISTANCE. | | | FROM THE INFORMATION PROVIDED I CANNOT DETERMINE | | | WHETHER OR NOT THE 6" AND 12" SPECIFIED ARE COMPLIANT. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-23 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-23 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2008-01-23 10:35:57 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2.PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE ATTACHED INSTALLATION SCHEDULE. | | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 507.3, | | | PROVIDE CALCULATIONS. | | | | | | 2.PROVIDE TWO COMPLETE COLLATED SETS OF DOCUMENTS FOR | | | PERMIT ISSUANCE. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-30 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-30 |
Time |
16:25 |
Sent To |
B |
|
| Notes |
| 2008-01-30 16:26:08 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-23 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-22 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2008-01-22 10:08:39 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |