| Plan Review Stops For Permit 08010430 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-02-28 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-02-28 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-01-29 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-01-29 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2008-01-29 11:11:30 | 2004 FBC W/2007 REVISIONS | | | LEVEL 3 ALTERATION | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE NEW 42" | | | WIDE EXTERIOR IN-SWING METAL DOOR AND THE STORM PANELS | | | FOR THE NEW WINDOW THAT WAS ADDED AS REQUIRED BY FAC | | | RULE 9B-72. | | | | | | 3)FBC 106.3* CITY AMENDMENTS. PRODUCT APPROVALS. | | | THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. THE ENGINEER THAT SEALED THE | | | PLANS IS REQUIRED TO REVIEW AND APPROVE THE PRODUCT | | | APPROVALS IN WRITING. | | | | | | 4) SPECIFY THE APPLICABLE CODE AND DESIGN CRITERIA FOR | | | THIS WORK ON THE PLANS. THE 2004 FBC W 2007 REVISIONS | | | IS THE CODE. DESIGN CRITERIA INCLUDES THE WIND SPEED, | | | IMPORTANCE FACTOR, EXPOSURE CATEGORY, ETC. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-25 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-25 |
Time |
07:25 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-01-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-18 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-18 |
Time |
15:20 |
Sent To |
Z |
|
| Notes |
| 2008-01-18 15:21:13 | | | | | | | ** DENIEDREVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE LIGHTING IN BATHROOM NEEDS TO MEET | | | 410.8 TO BE OUTSIDE SHOWER AREA OR MEETING THE | | | EXCEPTIONS FOR HEIGHT/CLEARANCE REQUIREMENTS ALONG WITH | | | CLOSED IN TYPE OF FIXTURES FOR SHOWER LOCATIONS. | | | AS THIS AREA ALL APPEARS TO BE A SHOWER, THESE WILL BE | | | REQUIRED TO BE RATED FOR SUCH LOCATIONS. | | | 110.3, 410.8 ETC | | | | | | 2) NOTE: PLEASE CLARIFY RECEPTACLE SPACING ALONG | | | KITCHEN COUNTER SPACES PER 210.52C1. IF NEW CABINETS, | | | COUNTERS AND WALL AREAS ARE DONE, SPACING SHALL MEET | | | CURRENT CODE. | | | | | | 3) NOTE: PLEASE SEE NEW SWITCH IN DINING ROOM WHICH | | | DOES NOT SHOW WHAT IS WILL BE CONTROLLING. | | | PLEASE SHOW. 210.70 | | | | | | 4) NOTE: PLEASE PROVIDE PANEL SCHEDULE WITH THE MINIMUM | | | NEW CIRCUITS BEING PROPOSED. FOR EXAMPLE: EXISTING | | | PLANS DID NOT SHOW BATH ROOM CIRCUIT, YET NEW SHOW NEW | | | GFI. | | | PLEASE SEE 210.11C3 FOR REQUIRED DEDICATED 20AMP AND | | | #12 BRANCH CIRCUITS. | | | 310.16, 408.4, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | 5) NOTE: PLANS INDICATE NEW DOOR OPENERS YET NO NEW | | | ELECTRICAL IS BEING SHOWN FOR THESE SAME LOCATIONS. | | | PLEASE COMPLETE INFORMATION. | | | 310.16, 240.4, ETC | | | | | | 6) NOTE: PLEASE SEE THE EXISTING UTILITY ROOM IS NOW | | | BEING SHOWN AND WILL BE CONSIDERED AN ADAPTABLE | | | SLEEPING ROOM PER NFPA-72. | | | PLEASE SEE AN ADDITIONAL SMOKE ALARMS (NOT DETECTORS) | | | WILL BE REQUIRED INSIDE AND OUTSIDE THIS ROOM. | | | 11.5.1.1.1 | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-20 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-20 |
Time |
10:43 |
Sent To |
Z |
|
| Notes |
| 2008-02-20 10:43:23 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-01-29 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-01-18 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2008-01-18 12:03:11 | TO "SFR" "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-27 |
Time |
10:16 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-02-27 |
Time |
10:16 |
Sent To |
B |
|
| Notes |
| 2008-02-27 10:17:42 | ONE BATHROOM EXHAUST FAN ONLY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-23 |
Time |
09:27 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-01-23 |
Time |
09:26 |
Sent To |
P |
|
| Notes |
| 2008-01-23 09:36:59 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) SCOPE OF WORK STATES INSTALL BATHROOM EXHAUST FAN, | | | PLAN SHOWS NO BATHROOM EXHAUST FAN, SEE 2004 FBC R303.3 | | | EXCEPT. PLEASE CORRECT. | | | | | | 2) SCOPE OF WORK ALSO STATES REPLACE A/C OUTLET FOR | | | BATHROOM-SHOWER AREA, PLEASE SHOW ON PLAN, AND ANY | | | OTHER MECHANICAL WORK TO BE DONE, SEE 2004 WPB AMEND. | | | 106.3.5.4 (10). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-02-26 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-02-26 |
Time |
15:32 |
Sent To |
M |
|
| Notes |
| 2008-02-26 15:33:05 | ****************PROVISO**************** | | | PER FBC PLUMBING TABLE 403.1 MINIMUM NUMBER OF | | | REQUIRED PLUMBING FIXTURES (R-3) ONE AND TWO FAMILY | | | DWELLINGS: PLEASE VERIFY THAT THERE IS AN EXISTING | | | AUTOMATIC CLOTHES WASHER CONNECTOR. NOTE: IF THERE IS | | | NOT AN EXISTING AUTOMATIC CLOTHES WASHER CONNECTOR A | | | REVISION WILL BE REQUIRED TO PROVIDE ONE. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-01-28 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-01-28 |
Time |
16:44 |
Sent To |
B |
|
| Notes |
| 2008-01-28 16:57:26 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1.SHEET A1 EXISTING FLOOR PLAN IS INDICATING THE | | | DEMOLITION OF THE EXISING SHOWER. PLEASE INDICATE THE | | | FOLLOWING PLUMBING REQUIREMENTS ON THE RESUBMITTAL. | | | PER FBC-2004 PLUMBING, SECTION 704.5 | | | DEAD ENDS: IN THE INSTALLATION OR | | | REMOVAL OF ANY PART OF A DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | | A PLUMBING PERMIT IS REQUIRED AND | | | INSPECTION REQUIRED OF DEMO WORK PRIOR | | | TO COVERING DEMO WORK WITH FINNISH | | | WALLS, CIELINGS, OR POURED CONCRETE | | | SLABS. | | | | | | 2. PER FBC-2004 CHAPTER 1 CITY WPB AMENDMENTS, SECTION | | | 106.3.5.4 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE | | | SUBMIT A PLUMBING SANITARY ISOMETRIC RISER DIAGRAM | | | INDICATING ALL WASTE, VENTS, TRAPS AND SIZES WITH | | | CLEANOUT LOCATIONS OF THE PROPOSED RELOCATED WATER | | | CLOSET AND SHOWER. | | | | | | 3. PER FBC PLUMBING TABLE 403.1 MINIMUM NUMBER OF | | | REQUIRED PLUMBING FIXTURES (R-3) ONE AND TWO FAMILY | | | DWELLINGS: PLEASE CLEARLY INDICATE THAT THERE IS AN | | | EXISTING OR A NEW, 1 AUTOMATIC CLOTHES WASHER | | | CONNECTOR. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-21 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-21 |
Time |
09:56 |
Sent To |
E |
|
| Notes |
| 2008-02-21 09:57:27 | ***APPROVED - RESUB #1 (RESTAMPED PLANS)*** | | | | | | | | | | | | | | | SENT TO "E" - BT (DP OUT) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-22 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-22 |
Time |
10:11 |
Sent To |
M |
|
| Notes |
| 2008-01-22 10:11:51 | ***APPROVED*** | | | | | | INTERIOR WORK, SLAB IN REAR. |
|
|