Plan Review Details - Permit 08010343
Plan Review Stops For Permit 08010343
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-04-07 Cont ID  
Sent By rmcdouga Date 2008-04-07 Time 10:14 Rev Time 0.00
Received By rmcdouga Date 2008-04-07 Time 10:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-03-17 Cont ID  
Sent By rmcdouga Date 2008-03-17 Time 16:47 Rev Time 0.00
Received By rmcdouga Date 2008-03-17 Time 16:47 Sent To  
Notes
2008-03-17 16:55:40REVIEW STATUS WILL BE CHANGED TO P AND PERMIT CAN BE
 PRINTED WHEN IMPACT FEES HAVE BEEN PAID, RADON FEES
 PAID AND NOC SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-03-06 Cont ID  
Sent By rmcdouga Date 2008-03-06 Time 10:39 Rev Time 0.00
Received By rmcdouga Date 2008-03-06 Time 06:56 Sent To  
Notes
2008-03-06 10:39:292004 FBC W/2007 REVISIONS
 ADDITION AND LEVEL 2 ALTERATIONS
  
 DENIED BY BUILDING
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 3) THE INFORMATION ON THE ENERGY CALCULATION FORM IS
 NOT CORRECT. SEE MECHANICAL COMMENTS. FBC 13-600
  
 4) THE AREA CALCULATIONS ON THE COVER SHEET ARE
 INCORRECT. PLEASE REVISE. FBC 106.1.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-28 Cont ID  
Sent By rmcdouga Date 2008-01-28 Time 10:17 Rev Time 0.00
Received By rmcdouga Date 2008-01-28 Time 07:05 Sent To P
Notes
2008-01-28 12:15:132004 FBC W/2007 REVISIONS
 ADDITION AND LEVEL 2 ALTERATIONS
  
 DENIED BY BUILDING
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3)SUBMIT ENERGY CALCULATIONS AS REQUIRED BY 2004 FBC
 SECTION 13-6. NOTE: IN ADDITION TO THE SIGNATURE OF THE
 PREPARER, THE OWNER/AGENT IS ALSO REQUIRED TO SIGN AND
 DATE THE FORM.
  
 4) SHOW COMPLIANCE OF THE BATHROOM WINDOWS WITH R308.4
 HAZARDOUS LOCATIONS.
 THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS
 LOCATIONS FOR THE PURPOSES OF GLAZING : 5. GLAZING
 IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS,
 SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN
 ANY PART OF A BUILDING WALL ENCLOSING THESE
 COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE
 GLAZING IS LESS THAN 60 INCHES (1524 MM) MEASURED
 VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE.
  
 5) PLEASE UPDATE THE CODE EDITION ON SHEETS 1 AND 2.
 THE CURRENT CODE IS THE 2004 FBC W/2007 REVISIONS.
  
 6) THE FOUNDATION NOTES ON SHEET 6 SPECIFY 2500 PSF AS
 THE REQUIRED SOIL BEARING CAPACITY AND THE DETAILS ON
 SHEETS 6,7,8,15 AND 16 SPECIFY THE SOIL COMPACTION AS
 2000 PSF. PLEASE CORRECT. 2004 FBC 106.1.1* CITY
 AMENDMENTS
  
 7) SHOW COMPLIANCE WITH SECTION 704 INSPECTION FOR
 TERMITES.
 IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS:
 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS
 THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE
 MASONRY FOUNDATION SIDEWALL.
 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE
 INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH
 RAMPS ONLY.
 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO
 AND GARAGE SLABS AND ENTRY AREAS.
  
 8) THE FOOTING SCHEDULE ON SHEET 6 REFERS DETAILS ON
 PAGE 6, HOWEVER, THESE FOOTING DETAILS ARE ON SHEET 7.
 PLEASE CORRECT
  
 9)THE KCC AND KECC COLUMN CAP CONNECTORS ARE
 INCORRECTLY SPECIFIED AS SIMPSON PRODUCTS AND THEY ARE
 MADE BY USP. THE UPLIFT VALUES ARE ALSO INCORRECT. THE
 KCC 44 HAS UPLIFT OF 3920 AND KECCLL HAS UPLIFT OF
 1750. SEE LATEST USP CATALOG OR THEIR WEBSITE.
  
 10) SUBMIT THE INSTALLATION DRAWINGS FOR THE STORM
 PANLES AS REQUIRED BY FAC RULE 9B-72. SPECIFY THE MOUNT
 TYPE, THE ANCHOR TYPE, ANCHOR SPACING, EDGE DISTANCE BY
 CIRCLING THE APPROPRIATE ITEMS ON THE INSTALLATION
 DRAWINGS AND TABLES.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-03-04 Cont ID  
Sent By dpalmer Date 2008-03-04 Time 13:13 Rev Time 0.00
Received By dpalmer Date 2008-03-04 Time 13:13 Sent To M
Notes
2008-03-04 13:14:27STAMPED ELECTRICAL PLANS OK.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-01-23 Cont ID  
Sent By dpalmer Date 2008-01-23 Time 12:53 Rev Time 0.00
Received By dpalmer Date 2008-01-23 Time 12:53 Sent To M
Notes
2008-01-23 12:53:42 
  
 ** DENIEDREVIEW **
  
 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH
 ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS
 UNDER THE NEW CODES ADOPTED BY THE STATE.
 PLEASE SEE THAT THIS SHALL INCLUDE 2007 REVISIONS TO
 THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70.
 PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY
 AFFECT DESIGNS FOR ALL TRADES.
 PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS
 REVIEWER AT A MINIMUM.
 2004 FBC W/ 2007 REVISIONS
 2005 NFPA-70
 2002 NFPA-72
  
 ** PLANS SHOW THE 2002 NFPA-70
  
 2) NOTE: PLEASE SEE PLANS DO NOT CONTAIN ANY
 INFORMATION, SIGNATURE, PRINTED NAME FOR ANY DESIGN
 PROFESSIONAL AS REQUIRED PER FAC, FBC ADMIN SECTION AS
 ADOPTED BY THE CITY OF WEST PALM BEACH 106.5, 106.1.2.
 FS 481.229, 471.003 OR 468.
 PLEASE SEE EXCEPTIONS IN 481.229 AND 471.003.
  
 3) NOTE: PLEASE SEE NFPA-72 DEFINITIONS AS THE SMOKE
 DETECTION DEVICES NOTED ON PLANS ARE SHOWN AND NOTED A
 *SMOKE DETECTORS*. SMOKE DETECTORS ONLY DETECT AND DO
 NOT SOUND AND ALARM. PLEASE SEE DEFINITION OF SMOKE
 ALARMS AS STATED IN NFPA-72 AND FBC R313.
 PLANS MENTIONS SD, WHERE THIS SEEMS TO BE THESE SHOULD
 BE SA.
 PLEASE ADJUST.
 PLEASE SEE NFPA-72 11.5.1.1 FOR LOCATIONS REQUIRED.
 PLEASE SEE MISSING SA OUTSIDE MASTER SLEEPING ROOM.
  
 4) NOTE: PLEASE SEE THE LIGHTING CONTROL FOR EGRESS
 FROM THE MASTER BEDROOM HALLWAY NEEDS TO BE LOCATED
 INSIDE THAT HALLWAY BEFORE EGRESS OUT OF THE REAR PATIO
 DOOR.
 PLEASE RELOCATE SWITCH.
 210.70, LS 101 7.8
  
 5) NOTE: PLEASE SEE MISSING RECEPTACLE PER 210.52 ON
 MASTER BEDROOM WALL WHICH IS GREATER THAN 2FT.
  
 6) NOTE: PLEASE SEE MINIMUM OVER CURRENT PROTECTION FOR
 THE 10KE HEAT-STRIP SHALL BE SIZED AT A MINIMUM OF 125%
 PER 424.3B.
  
 7) NOTE: PLEASE LIST ALL ITEMS ON PANEL SCHEDULE WHICH
 ARE NEW OR ALREADY EXISTS.
 PLEASE SEE SOME ITEMS ARE LABELED AS NEW HOWEVER NOT
 ALL.
 FOR EXAMPLE: WATER HEATER, WASHER, DRYER ETC.
 THIS ITEMS ARE SHOWN AS NEW ON PLANS.
 408.4.
 FBC 106.3.5.4
  
 8) NOTE: PLEASE SEE ELECTRICAL PLANS DOES INDICATE A
 NEW A/C WALL UNIT HOWEVER THERE IS NO DEDICATE CIRCUIT
 OR LOAD SHOWN ON PANEL SCHEDULE.
 240.4, 408.4, 310.16, 220 ETC
 PLEASE BE SURE TO SEE 210.12 FOR REQUIRED AFCI
 PROTECTION OF THIS UNIT.
  
 ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY
 QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR
 NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN
 CONTACTING THIS REVIEWER.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-03-27 Cont ID  
Sent By adarroug Date 2008-03-27 Time 14:50 Rev Time 0.00
Received By adarroug Date 2008-03-27 Time 14:50 Sent To B
Notes
2008-03-27 14:50:32TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-03-13 Cont ID  
Sent By adarroug Date 2008-03-13 Time 11:00 Rev Time 0.00
Received By adarroug Date 2008-03-13 Time 11:00 Sent To Z
Notes
2008-03-13 11:00:55TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-02-21 Cont ID  
Sent By adarroug Date 2008-02-21 Time 11:47 Rev Time 0.00
Received By adarroug Date 2008-02-21 Time 11:47 Sent To E
Notes
2008-02-21 11:47:42TO "E" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-01-28 Cont ID  
Sent By rmcdouga Date 2008-01-28 Time 10:17 Rev Time 0.00
Received By rmcdouga Date 2008-01-17 Time 09:09 Sent To  
Notes
2008-01-17 09:09:47TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-03-17 Cont ID  
Sent By tgordon Date 2008-03-17 Time 14:20 Rev Time 0.30
Received By tgordon Date 2008-03-17 Time 14:20 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-03-04 Cont ID  
Sent By tgordon Date 2008-03-04 Time 14:16 Rev Time 0.35
Received By tgordon Date 2008-03-04 Time 14:16 Sent To P
Notes
2008-03-04 14:50:21PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) SEE ENERGY CALCULATIONS HAVE THE WRONG ADDRESS ON
 THEM AND ARE THE JURISDICTION INFORMATION ON THEM,
 PLEASE CORRECT, PER 2004 FBC 13-600.3.A.
  
 2) SEE ENERGY CALCULATIONS LINE 6 SHOWS 864 SQ. FT.
 UNDER AIR. THE ADDITION IS 490 SQ. FT. UNDER AIR,
 PLEASE CORRECT (YOU MAY SUBMIT THE SHORT FORM 600C-04R
 FOR LESS THAN 600 SQ. FT. UNDER AIR. SEE 2004 FBC
 13-600.3.C.
  
 3) SEE ENERGY CALCULATIONS LINE 9A AND B ARE SHOWING
 THE WALLS TO BE CONCRETE WITH R-4.1 INSULATION, THE
 PLANS SHOW THE WALLS TO BE 2X4 WOOD WITH R-11
 INSULATION, PLEASE CORRECT ENERGY CAL'S. PER 2004 FBC
 13-6003.A.
  
 4) SEE ENERGY CAL'S. LINE 12A AND B ARE SHOWING THREE
 DIFFERENT A/C SYSTEMS, THE PLANS SHOW ONLY ONE NEW WALL
 UNIT BEING INSTALLED IN THE ADDITION, PLEASE CORRECT
 ENERGY CAL'S PER 2004 FBC 13-600.3.A.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-01-23 Cont ID  
Sent By tgordon Date 2008-01-23 Time 16:36 Rev Time 0.25
Received By tgordon Date 2008-01-23 Time 16:36 Sent To P
Notes
2008-01-23 16:45:07PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC
 13-101.2.2. AND HAVE ENERGY CALCULATIONS SIGNED BY
 OWNER/AGENT ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 2) PLEASE SHOW THE BATHROOM EXHAUST FANS ON THE
 MECHANICAL PLAN PAGE 20, AS THEIR SHOWN ON THE
 ELECTRICAL PLAN PAGE 18.
  
 3) PLEASE STATE ON THE MECHANICAL PLAN THAT THE A/C
 UNIT IN THE MASTER BEDROOM IS A ROOM AIR CONDITIONER.
  
 4) PLEASE SHOW ON MECHANICAL PLAN WERE THE CLOTHES
 DRYER VENT WILL TERMINATE, SEE 2004 FBC 303.4.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-03-05 Cont ID  
Sent By mperson Date 2008-03-05 Time 10:03 Rev Time 0.00
Received By mperson Date 2008-03-05 Time 10:03 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-01-28 Cont ID  
Sent By mperson Date 2008-01-28 Time 16:06 Rev Time 0.00
Received By mperson Date 2008-01-28 Time 16:06 Sent To PC
Notes
2008-01-28 16:21:04PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET 19 PLUMBING PLAN AND SANITARY RISER DIAGRAM
 BATHROOM #1: SHOWER NOT VENTED. PER FBC PLUMBING
 SECTION *901.2.1 VENTING REQUIRED.
  
 2. SHEET 19 PLUMBING PLAN AND SANITARY RISER DIAGRAM
 BATHROOM #2: TUB IS MISLABELED AS A SHOWER AND IS NOT
 VENTED. PER CITY WPB AMENDMENTS SECTION *106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS AND FBC PLUMBING
 SECTION *901.2.1 VENTING REQUIRED.
  
 3. SHEET 19 PLUMBING PLAN: PLEASE CORRECT THE SPELLING
 OF "RAISER" TO "RISER". PER CITY WPB AMENDMENTS SECTION
 *106.1.1 INFORMATION ON CONSRTRUCTION DOCUMENTS.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-03-17 Cont ID  
Sent By choops Date 2008-03-17 Time 13:08 Rev Time 0.00
Received By choops Date 2008-03-17 Time 13:08 Sent To M
Notes
2008-03-17 13:09:19***APPROVED - RESUB #2 (RESTAMPED PLANS)***
  
  
  
  
 SENT TO "M" - TG

Review Stop Z ZONING
Rev No 1 Status P Date 2008-01-22 Cont ID  
Sent By choops Date 2008-01-22 Time 16:57 Rev Time 0.00
Received By choops Date 2008-01-22 Time 16:57 Sent To E
Notes
2008-01-22 16:58:15***APPROVED***
  
  
  
  
 SENT TO "E" - SF RACK