Plan Review Details - Permit 08010276
Plan Review Stops For Permit 08010276
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2008-05-14 Cont ID  
Sent By lursu Date 2008-05-14 Time 09:18 Rev Time 0.00
Received By lursu Date 2008-04-16 Time 11:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-08-12 Cont ID  
Sent By jwitmer Date 2008-08-12 Time 11:30 Rev Time 0.77
Received By jwitmer Date 2008-08-12 Time 11:30 Sent To  
Notes
2008-08-12 11:31:05REVISION# 2 JULY 29/08 SHEET 1 OF 3 & SHEET 3 OF 3

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-05-14 Cont ID  
Sent By lmartine Date 2008-05-14 Time 11:01 Rev Time 0.00
Received By lmartine Date 2008-05-14 Time 11:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-04-11 Cont ID  
Sent By jwitmer Date 2008-04-11 Time 11:17 Rev Time 0.77
Received By jwitmer Date 2008-04-11 Time 11:17 Sent To  
Notes
2008-04-11 11:21:41BUILDING PLAN REVIEW
 PERMIT: 08010276
 ADD: 5910 S DIXIE HWY SUITE# 5908
 CONT: ABBATE BUILDING CO
 TEL: (772)501-1420
 JAN26, 2008
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 THE BUILDING PORTION OF THESE PLANS APPEARS TO BE CODE
 COMPLIANT BUT NOT UNTIL THE ADDRESS ISSUE CAN THE PLANS
 BE STAMPED REVIEWED. NOTE THIS WILL HOLD TRUE FOR BOTH
 THE ARCHITECTURAL AS WELL AS THE STRUCTURAL 81/2 X 14
 SHEETS.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-26 Cont ID  
Sent By jwitmer Date 2008-01-26 Time 16:34 Rev Time 1.44
Received By jwitmer Date 2008-01-26 Time 16:32 Sent To  
Notes
2008-01-26 17:21:02BUILDING PLAN REVIEW
 PERMIT: 08010276
 ADD: 5910 S DIXIE HWY SUITE# 5908
 CONT: ABBATE BUILDING CO
 TEL: (772)501-1420
 JAN26, 2008
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT.
 IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF
 YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A
 THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE2007 SUPPLEMENTS.
  
 2) JOHN D. CONLEY INC DOES NOTPROVIDE THEIR
 CERTIFICATE OF AUTHORIZATION, PLEASE PROVIDE.481.219
 F.S.CERTIFICATE OF AUTHORIZATION.THE TITLE BLOCK
 FOR ANY SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A
 PARTNERSHIP, OFFERING ARCHITECTURAL SERVICES, SHALL
 INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER.ADD
 THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND.
  
 3) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE
 OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
 B) 2004 FBC EXISTING BUILDING CODE, WHAT LEVEL OF
 ALTERATION IS TO BE CONSIDERED, IF LEVEL II SEE CHAPTER
 6 FOR LEVEL II ALTERATIONS.
 C) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE
 PROVISIONS OF CHAPTER 3.
 D) IS THIS A FIRE SPRINKLED BUILDING?
  
 4) SHEET 3OF 3 FRONT COUNTER ELEVATION DOES NOT
 INDICATE THE HEIGTH THE COUNTER, PLEASE PROVIDE
 COMPLIANCE WITH: 11-5.2 COUNTERS AND BARS WHERE FOOD OR
 DRINK IS SERVED @ COUNTERS EXCEEDING 34" IN HEIGHT FOR
 CONSUMPTION BY CUSTOMERS SEATED ON STOOLS OR STANDING
 AT THE COUNTER, A PORTION OF THE MAIN COUNTER WHICH IS
 60" IN LENGTH MINIMUM SHALL BE PROVIDED IN COMPLIANCE
 WITH 11-4.32 OR SERVICE SHALL BE AVAILABLE AT
 ACCESSIBLE TABLES WITHIN THE SAME AREA.
  
 5) PLANS INDICATE A NEW 5TON RTU-2 UNIT BUT NO
 INFORMATION WAS SUPPLIED AS TO THE ADDITIONAL LOADING
 TO THE ROOF FRAMING MEMBERS, NEW CURB ATTACHMENT,
 PLEASE PROVIDE ANCHORING INFORMATION FOR CURB AND POINT
 LOADING OF ROOF FRAMING MEMBERS, ADDITIONAL INFORMATION
 REQUIRED, 106.1.2 AND 1609.1.3 ANCHORAGE AGAINST
 OVERTURNING, UPLIFT AND SLIDING.
  
 6)PLANS INDICATE A NEW WALK IN COOLER, PLEASE INDICATE
 THE LOCATION OF THE COMPRESSOR. IF LOCATED ON THE ROOF
 ON A NEW PREMANUFACTURED A/C STAND THE FOLLOWING
 REQUIREMENTS ARE TO BE MET:
 6A) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING,
 PROVIDE 2 COPIES,3 IF THRESHOLD OR RESIDENT INSPECTOR
 OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS
 FOLLOWS: PREMANUFACTURED A/C STANDS
  
 6B) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT
 IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT
 HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR
 LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6C) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 7) PLEASE PROVIDE INFORMATION ON THE WALK IN COOLER,
 THICKNESS OF FOAM, FLAME SPREAD AND THICKNESS OF THE
 METAL FACINGMATERIALS OF COOLER, SECTION 2603.4.1.3.
  
  
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE
 APPLICABLE.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2008-09-09 Cont ID  
Sent By dpalmer Date 2008-09-09 Time 08:11 Rev Time 0.00
Received By dpalmer Date 2008-09-09 Time 08:11 Sent To PC
Notes
2008-09-09 08:12:36** REDLINED **
  
  
  
  
 1) NOTE: RISER MISSING THE EQUIPMENT GROUNDING METHOD
 FROM THE MAIN TO PANEL *B*. PLEASE SEE 250.110, 250.122
 ETC
  
  
  

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2008-09-02 Cont ID  
Sent By dpalmer Date 2008-09-02 Time 08:12 Rev Time 0.00
Received By dpalmer Date 2008-09-02 Time 08:12 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2008-08-13 Cont ID  
Sent By dpalmer Date 2008-08-13 Time 14:29 Rev Time 0.00
Received By dpalmer Date 2008-08-13 Time 14:29 Sent To  
Notes
2008-08-13 14:29:17** DENIED PLANS.**
  
  
 1) NOTE: CIRCUITING OF EMERGENCY AND EXIT LIGHTING TO
 MEET 700.12E. DOES NOT MEET EXCEPTION OF THE CODE.
  
 ** SHEET E1 OK AND STAMPED TO RETAIN FOR FILE.
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2008-06-16 Cont ID  
Sent By dpalmer Date 2008-06-16 Time 10:27 Rev Time 0.00
Received By dpalmer Date 2008-06-16 Time 10:27 Sent To PC
Notes
2008-06-16 10:43:20** REVISION DENIED**
  
 1) NOTE: ANY REVISIONS TO PLANS MUST BE DONE BY THE
 ENGINEER OF RECORD. FS 471.025.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-06-03 Cont ID  
Sent By dpalmer Date 2008-06-03 Time 15:28 Rev Time 0.00
Received By dpalmer Date 2008-06-03 Time 15:27 Sent To B
Notes
2008-06-03 15:29:53PLANS ROUTED TO LUIS MARTINEZ FOR PROCESSING. STILL
 NEEDS STAMPS ETC

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2008-04-24 Cont ID  
Sent By dpalmer Date 2008-04-24 Time 13:55 Rev Time 0.00
Received By dpalmer Date 2008-04-24 Time 13:55 Sent To  
Notes
2008-04-24 13:55:22** DENIED 2ND REVIEW **
  
 ** PLEASE SEE SOME OF THE EXACT SAME NOTES ARE IN NEED
 OF ADDRESSING. PLEASE ALSO SEE SOME NEW NOTES DUE TO
 THIS BEING THE SECOND REVIEW AND SOME PROJECT DOCUMENTS
 NOW SUBMITTED HAVE CHANGED.
  
 1) NOTE:PLEASE SEE THE VERSION OF ENERGY CALCULATIONS
 SUBMITTED IS NOT ADOPTED BY THE FBC. PLEASE SEE
 13-400.3.B, 13-400.A AS THIS VERSION SHALL BE 2.5.
 THE ENERGY GAUGE WEBSITE STATES THE ENERGY GAUGE SUMMIT
 VERSIONS 3.0-3.14 ARE ACCEPTABLE; HOWEVER PLEASE ALSO
 READ THE REMAINDER OF THE SENTENCE AS IT STATES THESE
 ARE INCORPORATED INTO THE VERSION 2.5. IN OTHER WORDS,
 THE VERSION WHICH IS SHOWN ON THE TOP OF THE PAGE
 SHOULD READ 2.5. THIS OFFICE HAS SPOKEN TO THE
 DEPARTMENT OF COMMUNITY AFFAIRS/FLORIDA BUILDING
 SPECIFICALLY ABOUT THIS AND THEIR RESPONSE IS THE CODE
 CLEARLY STATES VERSION 2.5.
 PLEASE BE SURE TO REVISE VERSION. THIS REVIEWER PLACED
 A CALL TO ENGINEER AND DESIGNER OF THIS PROJECT ON
 TUESDAY THE 22ND OF APRIL HOWEVER AS OF THIS REVIEW NO
 RETURN CALL HAS BEEN MADE TO THIS OFFICE. NEED TO
 DISCUSS THE CALCULATIONS.
 ** PLEASE EXPLAIN HOW METHOD *B* CAN BE USED. THIS IS
 NOT A WHOLE BUILDING AND DOES NOT QUALIFY AS A
 RENOVATION OF THE *BUILDING* BY DEFINITIONS.
 LIGHTING PERFORMANCE CALCULATIONS FOR LIGHTING
 COMPLIANCE LEVELS IS REQUIRED FOR THIS REVIEWER. PLEASE
 SEE ANY OTHER POSSIBLE COMMENTS FROM OTHER TRADES WHICH
 MAY AFFECT HOW THE CALCULATIONS NEED TO BE DONE FOR
 MECHANICAL SYSTEMS ETC.
  
 2) NOTE: PLEASE VERIFY LIGHTING CONTROLS AS DETAIL NOW
 ADDED TO E SHEET 2 OF 3 SHOWS OCCUPANCY SENSOR(S) YET
 THE PLANS DO NOT SHOWN ANY OF THESE DEVICES.
 PLEASE ALSO SEE THIS SAME DETAIL STATES OVER RIDES
 DEVICES AS *OPTIONAL* WHEN IN FACT THE PLANS SHOW THESE
 DEVICES BEING INSTALLED.
 PLEASE COORDINATE SYSTEM AND ALL DEVICES REQUIRED BY
 CODE AND WHAT WILL BE INSTALLED PER DESIGN.
 13-415.1.ABC.1.1, .2 AND .1.3.
 PLEASE VERIFY HOW LIGHTING PANEL WILL FEED THE CIRCUITS
 WHEN THE RISER SHOWS THE LIGHTING PANEL BEING FED FROM
 PANEL *B*. THE PLANS INDICATE THE LIGHTING CIRCUITS
 THROUGH PANEL *A*.
 PLEASE ALSO VERIFY HOW THE OUTSIDE LIGHT SHOWN ON THE
 SWITCH MEETS 13-415.1.ABC.1.4. THERE ARE TWO TYPES OF
 CONTROLS REQUIRED. BASED ON THE ELECTRICAL RISER AND
 INFORMATION SHOWN ON PLANS THIS DOES NOT MEET EITHER.
 PLEASE KNOW AN ASTRONOMICAL TIME CLOCK W/ A MINIMUM OF
 10HR BACK UP FOR PROGRAMMING OR PHOTO-SENSOR IS THE TWO
 OPTIONS.
  
 3) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO
 REPEAT COMMENTS FOR CODE COMPLIANCE.
 PLEASE KNOW THIS IS ONLY A NOTICE GIVEN AT THIS TIME.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-03-20 Cont ID  
Sent By dpalmer Date 2008-03-20 Time 16:27 Rev Time 0.00
Received By dpalmer Date 2008-03-20 Time 16:27 Sent To  
Notes
2008-03-20 16:28:00** DENIEDREVIEW **
  
  
 1) NOTE: PLEASE SEE THE VERSION OF THE SUBMITTED ENERGY
 CALCULATIONS IS NOT CORRECT. PLEASE SEE 13-400.3.B AS
 THIS SHOULD BE VERSION 2.5.
 PLEASE BE SURE THE OWNER AGENT SIGNATURE IS SIGNED ON
 CERTIFICATION SHEET.13-103.1.1.1
  
 2) NOTE: PLEASE SEE THE LIGHTING PERFORMANCE
 CALCULATIONS ON PLANS NOTE MENTIONS DISPLAY AND ACCENT
 LIGHTING IS NOT INCLUDED PER SECTIONS 13-415.B.1 AND
 13-415.2.C.1.
 PLEASE SEE 13-415.2.ABC.1 EXCEPTIONS AS DISPLAY AND
 ACCENT LIGHTING FOR THIS OCCUPANCY AND USE AS
 SPECIFICALLY SHOWN ON PLANS IS NOT EXEMPT.
 PLEASE SEE 13-415.2, 13-415.2.ABC.1.1, .1.2 FOR
 INTERIOR LIGHTING ALLOWANCES.
 PLEASE SEE THE IDR SHALL COORDINATE WITH PLANS.
  
 3) NOTE: PLEASE SEE 13-415.1.ABC.1.4 FOR CONTROL OF
 EXTERIOR LIGHT(S). PHOTO-SENSOR OR ASTRONOMICAL TIME
 CLOCK WITH A MINIMUM OF 10HRS BATTERY BACK UP FOR
 PROGRAMMING. PLEASE SHOW WHICH IS BEING USED, OR UNLESS
 BOTH ARE BEING INSTALLED.
 PLANS ONLY SHOW SINGLE POLE SWITCH.
  
 4) NOTE: PLEASE PROVIDE MAXIMUM TIMES ON ALL OVER RIDES
 DEVICES PER 13-415.1.ABC.1.1 AND OTHER OCCUPANCY SENSOR
 TYPE DEVICES.
  
 5) NOTE: PLEASE SEE THE ADDRESS ON PLANS AND ENERGY
 CALCULATIONS ARE INCORRECT.
 PLEASE SEE THE APPLIED LOCATION IS 5910 S. DIXIE HWY,
 YET ALL DOCUMENTS STATE 5908?
 PLEASE GET WITH THE ADDRESSING REVIEWER FOR FINAL
 DETERMINATION. IF A SUITE OR UNIT NUMBER IS TO BE
 GENERATED OR ADDRESS IS MODIFIED, THEN PLEASE BE SURE
 ALL TITLE BLOCKS AND DOCUMENTS ARE ADJUSTED.
 FAC 61G1-16.004, 61G15-23.002
  
 6) NOTE: PLEASE BE SURE TO REMOVE ALL OLD/VOIDED
 SHEETS. DO NOT LEAVE OLD SHEETS IN NEW SETS. PLEASE
 ALSO BE SURE NOT TO ATTACH SUPPORTING DOCUMENTS DOWN
 THE LEFT HAND SIDE OF PLANS.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID DELAYS.
  
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-01-17 Cont ID  
Sent By dpalmer Date 2008-01-17 Time 08:36 Rev Time 0.00
Received By dpalmer Date 2008-01-17 Time 08:36 Sent To  
Notes
2008-01-17 08:36:11** DENIED REVIEW **
  
 1) NOTE: PLEASE SUBMIT PLANS WITH THE FOLLOWING
 RELEVANT CODES STATED AND SHOWN ON PLANS.
 2004 FBC W/2007 REVISIONS.
 2005 NFPA-70
 2003 NFPA-101
  
 2) NOTE: PLEASE SEE ARCHITECTURAL PLANS ALONG WITH
 OTHER SHEETS WHICH CONTAIN A TITLE BLOCK FOR
 ARCHITECTURAL FIRM HOWEVER DOES NOT CONTAIN THE
 REQUIRED CERTIFICATE OF AUTHORIZATION NUMBER.
 PLEASE SEE 61G1-16.004 AND FS 481.219 WHICH BOTH
 REQUIRE THIS.
 THIS IS REQUIRED FOR ALL TRADES AND FOR ALL SHEETS
 WHETHER OR NOT COMMENTS ARE MADE BY OTHER TRADES.
 ** PLEASE SEE POSSIBLE NOTES FROM OTHER TRADES WITH
 RESPECT TO *SIGNATURE* REQUIRED ON ARCHITECTRUAL
 SHEETS.
  
 3) NOTE: PLEASE CLARIFY HOW IT IS THE PLANS ARE BEING
 SUBMITTED WITH METHOD A ENERGY CALCULATIONS.???
 PLEASE SEE THIS IS NOT A WHOLE BUILDING AND IS ONLY A
 TENANT REMODEL IN AN EXISTING BUILDING. THE SCOPE OF
 WORK IS NOT FOR THE BUILDING BY DEFINITION.
 PLEASE SEE THE LIGHTING PLANS INCLUDE A SPACE BY SPACE
 METHOD *B* IN NOTES, YET THE CALCULATIONS ARE NOT SPACE
 BY SPACE.??
 PLEASE SEE THE NOTE ON THIS SAME CALCULATION STATES
 FIXTURES *C* AND *B* ARE NOT INCLUDED. HOW IS THIS
 POSSIBLE?
 PLEASE SEE 13-415.2
 PLEASE ADJUST CALCULATIONS. PLEASE KNOW AS METHOD *A*
 CAN NOT BE USED, IT IS NOT REQUIRED FOR ELECTRICAL
 REVIEW. PLEASE CONFIRM WHAT IS NEEDED FROM THE
 MECHANICAL REVIEWER.
  
 4) NOTE: PLEASE KNOW THE SIGN(S) FOR EXTERIOR OF
 BUILDING IS REQUIRED TO BE UNDER SEPARATE PERMITS.
  
 5) NOTE: PLEASE INDICATE AIC RATINGS FOR NEW MAINS.
 110.9
  
 6) NOTE: PLEASE SEE THE EQUIPMENT GROUNDING CONDUCTOR
 SHOWN BEFORE THE FIRST MEANS OF DISCONNECT IS NOT
 PERMITTED.
 PLEASE SEE 250.6, 250.24.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2008-08-18 Cont ID  
Sent By mawillia Date 2008-08-18 Time 15:50 Rev Time 0.00
Received By mawillia Date 2008-08-18 Time 15:26 Sent To  
Notes
2008-08-18 15:48:32***** REVISION, DATED 7/28/08, APPROVED*****
  
  
 REVISED PLAN SHEETS FOR THE FLOOR PLAN (1 OF 3) AND
 INTERIOR FINISH (3 OF 3) WERE STAMPED, INITIALED, AND
 DATED;REVISED LIGHTING PLAN (2 OF 3) TO BE
 FIRE-STAMPED ONCE ELECTRICAL EXAMINER HAS BEEN
 SATISFIED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2008-06-02 Cont ID  
Sent By mawillia Date 2008-06-02 Time 15:32 Rev Time 0.00
Received By mawillia Date 2008-06-02 Time 15:09 Sent To  
Notes
2008-06-02 15:31:29*****APPROVED*****
  
  
 PLAN SHEETS FOR THE FLOOR PLAN (1 OF 3), INTERIOR
 FINISH (3 OF 3), AND THE LIGHTING PLAN (2 OF 3) WERE
 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-05-14 Cont ID  
Sent By mwennerg Date 2008-05-14 Time 10:32 Rev Time 0.00
Received By mwennerg Date 2008-05-14 Time 10:32 Sent To  
Notes
2008-05-14 10:33:46COMMENTS FROM PREVIOUS REVIEWS HAVE BEEN ADDRESSED.
 PLANS WILL BE STAMPED WHEN RETURNED WITH CORRECTIONS
 FOR OTHER REVIEW COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2008-04-11 Cont ID  
Sent By mawillia Date 2008-04-11 Time 17:39 Rev Time 0.00
Received By mawillia Date 2008-04-11 Time 17:08 Sent To  
Notes
2008-04-11 17:47:27*****DENIED*****
  
 THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS PLAN
 REVIEW STILL NEED TO BE ADDRESSED:
  
 01.THE ADDRESS (5908 SO. DIXIE) SHOWN IN THE TITLE
 BLOCK OF THE SUBMITTED PLAN SHEETS DOES NOT MATCH THAT
 OF 5910 SO. DIXIE WHICH COMES UP IN THE CITY'
 PERMITTING SYSTEM.SEE A LICENSE & PERMIT SPECIALIST
 IN THIS MATTER SO THAT THE CORRECT ADDRESS WILL BE
 LISTED ON THE ISSUED PERMIT
  
 06. INDICATE WHETHER THE STRUCTURE HAS A FIRE ALARM
 AND/OR FIRE SPRINKLER SYSTEM.PLEASE ACKNOWLEDGE
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-02-20 Cont ID  
Sent By mawillia Date 2008-02-20 Time 15:29 Rev Time 0.00
Received By mawillia Date 2008-02-20 Time 12:38 Sent To  
Notes
2008-02-20 14:58:00*****DENIED*****
  
  
 01.THE ADDRESS (5908 SO. DIXIE) SHOWN IN THE TITLE
 BLOCK OF THE SUBMITTED PLAN SHEETS DOES NOT MATCH THAT
 OF 5910 SO. DIXIE AS PER THE APPLIED PERMIT LOCATION.
  
 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS
 SHALL BE REMOVED FROM THE PREMISES AT THE END OF EACH
 SHIFT OR MORE FREQUENTLY AS NECESSARY FOR SAFE
 OPERATION.
  
 04.POST/DISPLAY THE NUMERICAL ADDRESS ON THE
 APPROPIATE ELEVATION WHICH FRONTS SOUTH DIXIE HIGHWAY.
 AS PER WEST PALM BEACH CODE, THE NUMBERS SHALL BE NO
 LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN
 WIDTH/STROKE.ADDRESS NUMBERS ARE NOT ALLOWED ON THE
 FRONT DOOR, HOWEVER IF THIS STRUCTURE IS PART OF AN
 ATTACHED BUILDING, ADDRESS NUMBER OF 3" IN HEIGHT SHALL
 BE REQUIRED ON THE REAR DOOR.
  
 05.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 06.PLEASE INDICATE THE FOLLOWING FOR THE STRUCTURE: *
 OCCUPANCY TYPE AND USE,* OCCUPANT LOAD,* FIRE ALARM
 AND/OR FIRE SPRINKLER SYSTEM,*AND ANY OTHER PERTINENT
 BUILDING INFORMATION
  
 07.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE.
  
 08.SPECIFY THE INTERIOR WALL AND CEILING FINISH
 MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C.
  
 09.COMMERCIAL COOKING EQUIPMENT SHALL BE IN
 ACCORDANCE WITH NFPA 96.SEPARATE PLANS AND PERMIT
 WILL BE REQUIRED FOR BOTH THE COOKING HOOD'S
 INSTALLATION AND THE COOKING HOOD'S SUPPRESSION
 SYSTEM.
  
 10.DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL FIRE
 ALARM AS PER LOCAL REQUIREMENTS.IF THE BUILDING IS
 NOT EQUIPPED WITH A FIRE ALARM SYSTEM, HOW WILL THE
 INITIATIATION OF A DUCT DETECTOR ACHIEVE OCCUPANT
 AND/OR EMERGENCY FORCES NOTIFICATION.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop G GAS REVIEW
Rev No 5 Status P Date 2008-08-05 Cont ID  
Sent By kstevens Date 2008-08-05 Time 12:53 Rev Time 0.00
Received By kstevens Date 2008-08-05 Time 12:53 Sent To  
Notes
2008-08-05 12:54:05REVISION OK--SHTS 1 OF 2 & 2 OF 2.

Review Stop G GAS REVIEW
Rev No 4 Status P Date 2008-05-20 Cont ID  
Sent By kstevens Date 2008-05-20 Time 07:15 Rev Time 0.00
Received By kstevens Date 2008-05-20 Time 07:15 Sent To  
Notes
2008-05-20 07:16:34PASSED/PROVISO:--A UNION IS REQUIRED DOWNSTREAM OF
 THE MANUAL SHUT OFF VALVE.

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2008-04-30 Cont ID  
Sent By kstevens Date 2008-04-30 Time 13:37 Rev Time 0.00
Received By kstevens Date 2008-04-30 Time 13:37 Sent To  
Notes
2008-04-30 13:42:48DENIED
 REFERENCE: FBC-2004 FUEL GAS
  
 ****FROM PREVIOUS REVIEW:
 ******FROM PREVIOUS REVIEWS:
  
 A. SEPARATE GAS PERMIT REQUIRED. THE FOLLOWING
 INFORMATION REQUIRED FOR PERMIT:
  
 1. OK
 2. OK
 3. OK
  
 4. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
 ****RESPONSE NOTED, NOT SHOWN ON ISOMETRIC RISER
 DIAGRAM.
 ******RESPONSE NOTED, BUT CLARIFICATION IS REQUIRED.
 PLEASE INDICATE THE DIFFERENCE BETWEEN THE GAS SOLENOID
 BELOW THE CEILING AND THE EMERGENCY HOOD SHUT OFF
 VALVE. THE REQUIREMENT IS FOR AN EMERGENCY HOOD SHUT
 OFF VALVE WITH A MANUAL SHUT OFF VALVE UPSTREAM AND A
 UNION DOWNSTREAM OF THE MANUAL VALVE. COMMENT NOT
 ADDRESSED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2008-04-04 Cont ID  
Sent By kstevens Date 2008-04-04 Time 16:48 Rev Time 0.00
Received By kstevens Date 2008-04-04 Time 16:48 Sent To  
Notes
2008-04-04 16:49:43DENIED
 REFERENCE: FBC-2004 FUEL GAS
  
 ****FROM PREVIOUS REVIEW:
  
 A. SEPARATE GAS PERMIT REQUIRED. THE FOLLOWING
 INFORMATION REQUIRED FOR PERMIT:
  
 1. OK
 2. OK
 3. OK
  
 4. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
 ****RESPONSE NOTED, NOT SHOWN ON ISOMETRIC RISER
 DIAGRAM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2008-02-11 Cont ID  
Sent By kstevens Date 2008-02-11 Time 18:50 Rev Time 0.00
Received By kstevens Date 2008-02-11 Time 18:50 Sent To  
Notes
2008-02-11 18:54:02DENIED
 REFERENCE: FBC-2004 FUEL GAS
  
 A. SEPARATE GAS PERMIT REQUIRED. THE FOLLOWING
 INFORMATION REQUIRED FOR PERMIT:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
  
 2. TYPE OF GAS, (LP OR NATURAL).
  
 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
  
 4. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-09-29 Cont ID  
Sent By rregueir Date 2008-09-29 Time 10:55 Rev Time 0.00
Received By rregueir Date 2008-09-29 Time 10:54 Sent To M
Notes
2008-09-29 10:55:07TO RJR DESK

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2008-09-05 Cont ID  
Sent By adarroug Date 2008-09-05 Time 09:12 Rev Time 0.00
Received By adarroug Date 2008-09-05 Time 09:12 Sent To E
Notes
2008-09-05 09:12:36TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-08-26 Cont ID  
Sent By tgordon Date 2008-08-26 Time 16:26 Rev Time 0.00
Received By tgordon Date 2008-08-26 Time 16:26 Sent To E
Notes
2008-08-26 16:26:57TO "ELECT" D.P.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-07-30 Cont ID  
Sent By adarroug Date 2008-07-30 Time 16:07 Rev Time 0.00
Received By adarroug Date 2008-07-30 Time 16:07 Sent To  
Notes
2008-07-30 16:11:38TO "COMM" BD#47

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-06-10 Cont ID  
Sent By adarroug Date 2008-06-10 Time 11:05 Rev Time 0.00
Received By adarroug Date 2008-06-10 Time 11:05 Sent To E
Notes
2008-06-10 11:06:06TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-05-16 Cont ID  
Sent By adarroug Date 2008-05-16 Time 14:02 Rev Time 0.00
Received By adarroug Date 2008-05-16 Time 14:02 Sent To  
Notes
2008-05-19 09:10:27TO "COMM" BD#13
2008-05-16 14:02:30WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-04-16 Cont ID  
Sent By adarroug Date 2008-04-16 Time 16:52 Rev Time 0.00
Received By adarroug Date 2008-04-16 Time 16:52 Sent To  
Notes
2008-04-16 16:55:57TO "COMM" BD#53

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-03-18 Cont ID  
Sent By adarroug Date 2008-03-18 Time 16:07 Rev Time 0.00
Received By adarroug Date 2008-03-18 Time 16:07 Sent To  
Notes
2008-03-19 13:35:05TO "COMM" BD#31
2008-03-18 16:07:17WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-02-20 Cont ID  
Sent By mawillia Date 2008-02-20 Time 12:38 Rev Time 0.00
Received By mawillia Date 2008-01-14 Time 12:02 Sent To  
Notes
2008-01-14 12:02:36TO "COMM" BD#50

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2008-09-29 Cont ID  
Sent By rregueir Date 2008-09-29 Time 10:56 Rev Time 0.00
Received By rregueir Date 2008-09-29 Time 10:55 Sent To PC
Notes
2008-09-29 10:56:09REVISED DETAIL FOR HANGING KITHEN HOOD AND INSTALLATION
 OF ROOFTOP CONDENSER STANDS.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-04-28 Cont ID  
Sent By tgordon Date 2008-04-28 Time 14:36 Rev Time 0.30
Received By tgordon Date 2008-04-28 Time 14:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-03-20 Cont ID  
Sent By tgordon Date 2008-03-20 Time 09:13 Rev Time 0.30
Received By tgordon Date 2008-03-20 Time 09:13 Sent To  
Notes
2008-03-20 09:19:32PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) THE ENERGY CALCULATIONS NEED TO BE GENERATED BY THE
 FLA/COM-2004 COMPUTER PROGRAM, VERSION 2.5 NOT 3.0, ON
 FORM 400B-04, PER 2004 FBC 13-400.3.B. PLEASE CORRECT.
  
 2) WHEN RESUBMITTING ENERGY CALCULATIONS HAVE THEM
 SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC 13-103.3.
  
 3) THE COOLING LOAD CALCULATIONS ARE MISSING FROM THE
 ENERGY CAL'S. PLEASE SUBMITCOOLING LOAD CALCULATIONS,
 PER 2004 FBC 13-407.1.ABC.1.
  
 4) THE PLANS AND ENERGY CALCULATIONS ARE SHOWING THE
 WRONG ADDRESS THE BUILDING NUMBER IS 5910 S. DIXIE HWY.
 PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-01-17 Cont ID  
Sent By tgordon Date 2008-01-15 Time 15:17 Rev Time 0.40
Received By tgordon Date 2008-01-15 Time 15:17 Sent To  
Notes
2008-01-15 15:18:39ADDITIONAL MECHANICAL PERMITS REQUIRED FOR
 (A) WALK-IN-COOLER
 (B) KITCHEN HOOD
 (C) FIRE SUPPRESSION
 ** SUBMIT PLANS WITH PERMIT APPLICATION.
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) SEE ELECTRICAL REVIEW NOTES 1, 2, 3. PLEASE
 CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2008-08-05 Cont ID  
Sent By kstevens Date 2008-08-05 Time 12:50 Rev Time 0.00
Received By kstevens Date 2008-08-05 Time 12:50 Sent To  
Notes
2008-08-05 12:51:38REVISION OK--SHTS 1 0F 2 & 2 OF 2

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-05-20 Cont ID  
Sent By kstevens Date 2008-05-20 Time 07:15 Rev Time 0.00
Received By kstevens Date 2008-05-19 Time 15:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-04-25 Cont ID  
Sent By kstevens Date 2008-04-25 Time 07:29 Rev Time 0.00
Received By kstevens Date 2008-04-25 Time 07:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-04-04 Cont ID  
Sent By kstevens Date 2008-04-04 Time 11:14 Rev Time 0.00
Received By kstevens Date 2008-04-04 Time 11:13 Sent To  
Notes
2008-04-04 11:22:36DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2004 FUEL GAS
 CITY WPB MUNICIPAL CODE
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES.
  
 ****FROM PREVIOUS REVIEW:
  
 1. OK
 2. OK
 3. OK
 4. SHT 1 OF 2 THE GREASE INTERCEPTOR UNDER THE SINK IS
 NOT APPROVED. A MINIMUM 750 GAL. GREASE INTERCEPTOR IS
 REQUIRED. PLEASE CONTACT RODNEY COMPO, ENVIRONMENTAL
 COMPLIANCE AT (561) 644-1821, (FAX) - (561) 822-2272 -
 OR E-MAIL [email protected]. A WRITTEN DETERMINATION IS
 REQUIRED TO BE SUBMITTED FOR APPROVAL OF THE GREASE
 INTERCEPTOR WHEN RESUBMITTING TO THE CITY FOR REVIEW.
 WPB MUNICIPAL CODE ARTICLE III SECTION
 90-124(7)(B)(C)(E)(F).
 ****RESPONSE NOTED, BUT THE WRITTEN APPROVAL FROM MR.
 RODNEY COMPO HAS NOT BEEN SUBMITTED.
  
 5. OK
 6. OK
  
 7. SHT 2 OF 2 RISER #2 THE GREASE INTERCEPTOR IS NOT
 APPROVED INSIDE. A MINIMUM 750 GALLON GREASE
 INTERCEPTOR IS REQUIRED. (SEE COMMENT #4). THE MOB SINK
 SHALL CONNECT TO THE GREASE SYSTEM.
 ****RESPONSE NOTED, BUTTHE WRITTEN APPROVAL FROM MR.
 RODNEY COMPO HAS NOT BEEN SUBMITTED.
  
 8. OK
  
 9. THE FLOOR DRAIN BY THE COOLER IS NOT VENTED. MAXIMUM
 DISTANCE FROM POINT OF VENT IS 10 FEET. TABLE
 906.1.****RESPONSE NOTED, BUT THE FLOOR SINK IS NOT
 VENTED PER TABLE 906.1. A WET VENT IS FOR BATHROOM
 FIXTURES ONLY AND "WET VENT" IS NOT IN THE DEFINITIONS
 IN SECTION 202. PLEASE CLARIFY THE MEANING OF THE
 RESPONSE. SEE WET VENT:909.1 WET VENT PERMITTED. ANY
 COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS
 LOCATED ON THE SAME FLOOR LEVEL ARE PERMITTED TO BE
 VENTED BY A WET VENT. THE WET VENT SHALL BE CONSIDERED
 THE VENT FOR THE FIXTURES AND SHALL EXTEND FROM THE
 CONNECTION OF THE DRY VENT ALONG THE DIRECTION OF THE
 FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM FIXTURE
 DRAIN CONNECTION TO THE HORIZONTAL BRANCH DRAIN. ONLY
 THE FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT
 TO THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY
 ADDITIONAL FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE
 WET VENT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-02-11 Cont ID  
Sent By kstevens Date 2008-02-11 Time 18:54 Rev Time 0.00
Received By kstevens Date 2008-02-11 Time 18:54 Sent To  
Notes
2008-02-11 19:12:13DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2004 FUEL GAS
 CITY WPB MUNICIPAL CODE
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES.
  
 1. PLEASE INDICATE THE RELEVANT CODES ON PLANS.
  
 2. ALL ARCHITECTURAL SHEETS. THE BUSINESS LICENSE,
 (CERTIFICATE OF AUTHORIZATION), IS REQUIRED IN THE
 TITLE BLOCK OF EACH SHEET. FAC 61G1-16.219,
 61G1-16.004(2) & FS 481.2055.
  
 3. ROUTE PLANS TO THE STATE OF FLORIDA, DEPT OF
 BUSINESS REGULATION, (DBR), DIVISION OF HOTEL AND
 RESTAURANT FOOD SERVICE LICENSE PRIOR TO RESUBMITTING
 TO THE CITY FOR REVIEW. A MINIMUM TWO SETS OF PLANS
 CONTAINING THE DBPR STAMPED, (REVIEWED) SHEET AND THE
 SPECIFICATION WORK SHEETS SHALL BE SUBMITTED FOR
 REVIEW. SECTION 102.2.1.
  
 4. SHT 1 OF 2 THE GREASE INTERCEPTOR UNDER THE SINK IS
 NOT APPROVED. A MINIMUM 750 GAL. GREASE INTERCEPTOR IS
 REQUIRED. PLEASE CONTACT RODNEY COMPO, ENVIRONMENTAL
 COMPLIANCE AT (561) 644-1821, (FAX) - (561) 822-2272 -
 OR E-MAIL [email protected]. A WRITTEN DETERMINATION IS
 REQUIRED TO BE SUBMITTED FOR APPROVAL OF THE GREASE
 INTERCEPTOR WHEN RESUBMITTING TO THE CITY FOR REVIEW.
 WPB MUNICIPAL CODE ARTICLE III SECTION
 90-124(7)(B)(C)(E)(F).
  
 5. SHT 2 OF 3 EQUIPMENT SCHEDULE INDICATES A GAS WATER
 HEATER, 70,000 BTU'S, BUT SHT 1 OF 2 DOES NOT SHOW
 THIS. PLEASE CLARIFY & CORRELATE THE PLANS. SECTION
 106.1.1.
  
 6. SHT 2 OF 2 DETAIL 2, FLOOR DRAINS ARE NOT APPROVED
 INDIRECT WASTE RECEPTORS. A FLOORSINK OR HUB DRAIN IS
 REQUIRED. SECTIONS 802.3 & 802.3.2.
  
 7. SHT 2 OF 2 RISER #2 THE GREASE INTERCEPTOR IS NOT
 APPROVED INSIDE. A MINIMUM 750 GALLON GREASE
 INTERCEPTOR IS REQUIRED. (SEE COMMENT #4). THE MOB SINK
 SHALL CONNECT TO THE GREASE SYSTEM.
  
 8. SHT 2 OF 2 FLOOR DRAIN BY THE COOLER IS NOT AN
 APPROVED INDIRECT WASTE INTERCEPTOR. A FLOORSINK OR
 HUB DRAIN IS REQUIRED. SECTIONS 802.3 & 802.3.2.
  
 9. THE FLOOR DRAIN BY THE COOLER IS NOT VENTED. MAXIMUM
 DISTANCE FROM POINT OF VENT IS 10 FEET. TABLE 906.1.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status N Date 2008-03-19 Cont ID  
Sent By choops Date 2008-03-19 Time 14:15 Rev Time 0.00
Received By choops Date 2008-03-19 Time 14:15 Sent To  
Notes
2008-03-19 14:17:08***ZONING REVIEW NOT REQUIRED - INTERIOR WORK ONLY***
  
 *EXTERIOR SIGNAGE SHOWN ON ORIGINALLY SUBMITTED PLANS
 HAS BEEN REMOVED.EXTERIOR SIGNAGE ON PERMIT #08010732
 AND #08010731.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-01-23 Cont ID  
Sent By choops Date 2008-01-23 Time 15:37 Rev Time 0.00
Received By choops Date 2008-01-23 Time 15:36 Sent To  
Notes
2008-01-23 15:39:37***FAILED***
  
  
 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY
 SHOWING THE LOCATION OF THE PROPOSED EXTERIOR SIGNAGE.
  
 2)AS THE ALLOWABLE SQUARE FOOTAGE FOR THE EXTERIOR
 SIGNAGE IS BASED UPON THE SQUARE FOOTAGE OF THE
 BUILDING FACADE ON WHICH IT IS MOUNTED, PROVIDE THE
 BUILDING HEIGHT SO SUCH CALCULATIONS CAN BE PERFORMED.
  
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720