Plan Review Details - Permit 08010251
Plan Review Stops For Permit 08010251
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2008-01-30 Cont ID  
Sent By lursu Date 2008-01-30 Time 09:52 Rev Time 0.00
Received By   Date 2008-04-29 Time 14:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2010-05-25 Cont ID  
Sent By lmartine Date 2010-05-25 Time 18:08 Rev Time 0.00
Received By lmartine Date 2010-05-25 Time 18:08 Sent To  
Notes
2010-05-25 18:12:23APPROVED RE-STAMP UNDER 2007 FBC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2008-02-19 Cont ID  
Sent By mjacobs Date 2008-02-19 Time 15:01 Rev Time 0.00
Received By mjacobs Date 2008-02-19 Time 14:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-01-29 Cont ID  
Sent By mjacobs Date 2008-01-29 Time 10:23 Rev Time 0.00
Received By mjacobs Date 2008-01-29 Time 09:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2008-01-16 Cont ID  
Sent By mjacobs Date 2008-01-16 Time 08:12 Rev Time 0.00
Received By mjacobs Date 2008-01-16 Time 07:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2010-05-27 Cont ID  
Sent By btrobaug Date 2010-05-27 Time 06:25 Rev Time 0.00
Received By btrobaug Date 2010-05-27 Time 05:58 Sent To B
Notes
2010-05-27 06:25:35T LUIS DESK./WRT.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-04-09 Cont ID  
Sent By dpalmer Date 2008-04-09 Time 11:12 Rev Time 0.00
Received By dpalmer Date 2008-04-09 Time 11:12 Sent To  
Notes
2008-04-09 11:13:06ALL MAINS GROUPED PER 230.72

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2008-02-15 Cont ID  
Sent By dpalmer Date 2008-02-15 Time 11:19 Rev Time 0.00
Received By dpalmer Date 2008-02-15 Time 11:19 Sent To  
Notes
2008-02-15 11:19:30*** DENIED3RD REVIEW***
  
 ** PLEASE SEE SOME ITEMS WHICH ARE THE SAME FROM THE
 TWO PREVIOUS REVIEWS ARE STILL IN NEED OF ADDRESSING.
  
 1) NOTE: PLEASE SEE THE TWO PREVIOUS REVIEWS STATED NEC
 230.72 FOR GROUPING OF MAINS AND TO SHOW THE LOCATION
 OF ALL EQUIPMENT ON PLANS.
 PLEASE SEE THE RISER AND PLANS STILL SHOW THE NEW MCB
 PANEL FOR UNIT 101 IN THE UNIT WHICH DOES NOT GROUP
 MAINS AS REQUIRED PER CODE.
 PLEASE RELOCATE AND COMPLETE RISER WITH ALL
 INFORMATION.
 240.24, 110.26, 230.72 ETC
 ** KEEP IN MIND AS ADDING A NEW MAIN OUTSIDE GROUPED
 WITH OTHER MAINS WILL BE REQUIRED, PLEASE BE SURE TO
 INCLUDE ALL CODE COMPLIANCE INFORMATION FOR NEW
 DISCONNECT INCLUDING AN EQUIPMENT GROUNDING CONDUCTOR
 FROM NEW MAIN TO PANEL INSIDE.
  
 2) NOTE: PLEASE SEE PREVIOUS NOTES REQUESTED TO SHOW
 THE LOCATION OF THE REQUIRED SIGN CIRCUIT. THE PANEL
 SCHEDULE SHOWS THE REQUIRED CIRCUIT HOWEVER THE
 ELECTRICAL PLANS STILL DO NOT SHOW THIS LOCATION.
 PLEASE SEE 600.5
  
 3) NOTE: PLEASE SEE ATTACHED PRINT OUT OF FLORIDA
 STATUTES 553.80(2)(B) WITH RESPECT TO REPEAT COMMENTS
 FOR CODE COMPLIANCE.
 THE SAME CODE SECTIONS FOR GROUPING OF MAINS HAVE BEEN
 CITED THREE TIMES. THE FEE AS REQUIRED BY STATUE IS
 ASSESSED. THIS IS A STATE STATUE AND NOT A LOCAL
 ADMINISTRATIVE ASSESSMENT.
 PLEASE SEE THE FEE OF $ 379.20 IS REQUIRED TO BE PAID
 BEFORE RESUBMISSION OF PLANS.
  
 ** IF THERE ARE QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-01-29 Cont ID  
Sent By dpalmer Date 2008-01-29 Time 11:51 Rev Time 0.00
Received By dpalmer Date 2008-01-29 Time 11:51 Sent To  
Notes
2008-01-29 11:51:39** DENIED 2ND REVIEW **
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW STILL
 NEED TO BE ADDRESSED ALONG WITH NEW COMMENTS AS RISER
 HAS NOW BEEN REVISED ONCE AGAIN WITH ITEMS WHICH WAS
 NOT ON PREVIOUS PLANS.
  
  
  
 1) NOTE: PLEASE SEE THE A ?COVER SHEET STILL INDICATE
 SUITE/UNIT SCOPE OF WORK FOR SUITE/UNIT #102. AS THIS
 APPLIED SCOPE OF WORK IS FOR ANOTHER SUITE/UNIT SPACE
 PLEASE ADJUST COVER SHEET.
 PLEASE KNOW THE ADDRESS EXTENSION OF PROJECT HAS NOT
 YET BEEN CONFIRMED WITH THE ADDRESSING REVIEWER. PLEASE
 KEEP IN MIND ANY CHANGES BASED ON THEIR REVIEW MAY
 REQUIRE TITLE BLOCK ADJUSTMENTS ON OTHER SHEETS. FAC
 61G1-16.004, 61G15-23.002
 FBC 106.5, 106.1.2 ADMIN SECTION.
  
 2) NOTE: PLEASE SEE AS MENTIONED AND NOTED ON PREVIOUS
 REVIEW TO LOCATIONS OF MAINS AS PER 230.72. THIS WAS
 NOT DONE. THE NEW MAIN CIRCUIT BREAKER PANEL FOR SUITE
 # 101 IS SHOWN INSIDE THE UNIT WITH NO MAIN GROUPED
 WITH OTHER MAINS OR LABELED AS REQUIRED PER 230.72,
 230.70, 230.71, 230.2E ETC.
  
 3) NOTE: PLEASE SEE THE LOAD CALCULATIONS NOTES AND
 MENTIONS CONDUCTORS FOR SERVICE ENTRANCE ARE RATED FOR
 385AMPS EACH PHASE HOWEVER BASED ON THE MINIMUM
 REQUIREMENTS AND CONDUCTOR AMPACITIES IN THE NATIONAL
 ELECTRICAL CODE AS WELL AS THE ADOPTED AWG STANDARD.
 THE 350MCM CONDUCTORS ARE NOT RATED FOR 385AMPS. PLEASE
 SEE 110.14, 310.16 AND 240.4.
 PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS AS SHOWN
 SHALL BE INCREASED.
  
 4) NOTE: PLEASE SEE RISER CONTAINS NOTES FOR EXISTING
 SUITE/UNIT #102 HOWEVER NOT SUCH SAME NOTES ARE SHOWN
 FOR NEW SUITE/UNIT #101.
 PLEASE SEE THE BOTTOM RIGHT HAND CORNER OF THE RISER
 SHEET E-2.
 PLEASE COMPLETE WITH NEW, SAME OR EXISTING
 INFORMATION.
 FBC 106.1.2, 106.3.5.1.2 ADMIN SECTIONS FOR ADDITIONAL
 INFORMATION.
  
 5) NOTE: PLEASE SEE THE LOCATION OF THE SIGN CIRCUIT
 WAS NOT SHOWN. PER 600.5
  
 ** AS SOME ITEMS ARE GOING TO CHANGE SUBSTANTIALLY,
 THERE MAY BE NEW COMMENTS WHICH CAN NOT BE MADE AT THIS
 TIME.
  
  
 ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY
 QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR
 NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN
 CONTACTING THIS REVIEWER.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-01-16 Cont ID  
Sent By dpalmer Date 2008-01-16 Time 08:53 Rev Time 0.00
Received By dpalmer Date 2008-01-16 Time 08:53 Sent To  
Notes
2008-01-16 08:53:33** DENIED REVIEW **
  
 1) NOTE: PLEASE SUBMIT PLANS WITH THE FOLLOWING
 RELEVANT CODES.
 2004 FBC W/2007 REVISIONS.
 2005 NFPA-70
 2003 NFPA-101
 2002 NFPA-72 (IF APPLICABLE)
  
 2) NOTE: PLEASE SHOW LOCATIONS OF ALL NEW SERVICE
 EQUIPMENT. CAN NOT VERIFY CODE COMPLIANCE WITH 240.24,
 110.26, 408.17 AND 230.72
  
 3) NOTE: PLEASE LABEL NEW MAINS. 230.2E.
 PLEASE PROVIDE PANEL DESIGNATIONS OF SOME SORT.
 EXAMPLES: PNL A, PNL B ETC. PLEASE SHOW WHAT IS NEW AND
 WHAT EXISTS. PLEASE KNOW AS THESE PLANS ARE THEIR OWN
 RECORD SET PLANS NEED TO SHOW ALL RELEVANT INFORMATION.
 MAY NOT RELY ON PREVIOUS PERMITTED PLANS.
  
 4) NOTE: PLEASE INCLUDE LOAD ON EXISTING SERVICE WITH
 NEW LOADS BEING ADDED.
 PLEASE SEE 220.87, 215.3, 230.42
 ALL CONTINUOUS LOADS AT 125%.
  
 5) NOTE: PLEASE PROVIDE LOCATION OF NEW MAIN. 230.72
  
 6) NOTE: PLEASE PROVIDE MORE INFORMATION FOR LIGHTING
 CONTROLS PER 13-415.1.ABC.1.1, .1.2 ETC
 PLANS SHOW ONE OCCUPANCY SENSOR AT THE REAR OF SPACE
 AND NO CONTROLS AT OTHER LOCATIONS.
 HOW WILL COVERAGE BE MET IN THE FRONT SPACE AS IT IS
 CONSIDERED SEPARATE FROM REAR?
  
 7) NOTE: PLEASE SEE THE LOCATION OF THE REQUIRED SIGN
 CIRCUIT IS NOT SHOWN ON PLANS.
 600.5
  
 8) NOTE: PLEASE KNOW AN EQUIPMENT GROUNDING CONDUCTOR
 WILL BE REQUIRED IN ANY EMT CONDUITS UNLESS SPECIFIC
 FITTING WHERE ARE NOW REQUIRED TO BE *LISTED* FOR
 *EQUIPMENT GROUNDING* IS USED AND INSTALLED. THIS IS
 NOTED NOW FOR INFORMATION WHICH MAY PREVENT REVISED
 PLANS AT A LATER DATE.
 110.3, 250.110, 250.122, ETC
  
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2010-07-26 Cont ID  
Sent By mcarsill Date 2010-07-26 Time 09:07 Rev Time 0.00
Received By mcarsill Date 2010-07-26 Time 09:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2010-06-02 Cont ID  
Sent By mawillia Date 2010-06-02 Time 11:06 Rev Time 0.00
Received By mawillia Date 2010-06-02 Time 10:25 Sent To  
Notes
2010-06-02 11:06:29*****APPROVED*****
  
 PLAN SHEETS A-2 AND E-1 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-02-01 Cont ID  
Sent By mwennerg Date 2008-02-01 Time 14:00 Rev Time 0.00
Received By mwennerg Date 2008-02-01 Time 13:59 Sent To  
Notes
2008-02-01 14:00:34STAMPED SHEET A-2

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2008-01-16 Cont ID  
Sent By mwennerg Date 2008-01-16 Time 15:14 Rev Time 0.00
Received By mwennerg Date 2008-01-16 Time 15:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2010-05-05 Cont ID  
Sent By jgomez Date 2010-05-05 Time 08:29 Rev Time 0.00
Received By jgomez Date 2010-05-05 Time 08:29 Sent To  
Notes
2010-05-05 08:34:25SENT TO L. MARTINEZ DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-04-07 Cont ID  
Sent By adarroug Date 2008-04-07 Time 16:36 Rev Time 0.00
Received By adarroug Date 2008-04-07 Time 16:35 Sent To B
Notes
2008-04-07 16:36:18TO "BOB"#9

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-02-08 Cont ID  
Sent By adarroug Date 2008-02-08 Time 16:14 Rev Time 0.00
Received By adarroug Date 2008-02-08 Time 16:14 Sent To  
Notes
2008-02-08 16:19:39TO "BOB"#11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-01-23 Cont ID  
Sent By adarroug Date 2008-01-23 Time 10:46 Rev Time 0.00
Received By adarroug Date 2008-01-23 Time 10:46 Sent To  
Notes
2008-01-23 10:49:24TO "BOB"#11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-01-16 Cont ID  
Sent By mwennerg Date 2008-01-16 Time 15:24 Rev Time 0.00
Received By mwennerg Date 2008-01-11 Time 10:31 Sent To  
Notes
2008-01-11 10:31:11TO BOB # 10

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2008-04-29 Cont ID  
Sent By rkussner Date 2008-04-29 Time 14:26 Rev Time 0.00
Received By rkussner Date 2008-04-29 Time 14:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2010-05-25 Cont ID  
Sent By hmoser Date 2010-05-25 Time 12:49 Rev Time 0.00
Received By hmoser Date 2010-05-25 Time 12:49 Sent To  
Notes
2010-05-25 13:03:41PASS PROVISO
 1) PLEASE REFER TO SECTION 601.4 BALANCED RETURN AIR
 2007 FBC (M) . EXCEPTION # 3 HABITABLE ROOMS ONLY
 BATHROOMS , CLOSETS , STORAGE ROOMS AND LAUNDRY ROOMS
 ARE NOT HABITABLE ROOMS .
 2) PLEASE REFER TO SECTION 301.12 WIND RESISTANCE .
 MECHANICAL EQUIPMENT APPLIANCES AND SUPPORTS THAT ARE
 EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO
 RESIST THE WIND PRESSURES .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-01-23 Cont ID  
Sent By tgordon Date 2008-01-23 Time 16:12 Rev Time 0.25
Received By tgordon Date 2008-01-23 Time 16:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-01-15 Cont ID  
Sent By tgordon Date 2008-01-15 Time 10:50 Rev Time 0.30
Received By tgordon Date 2008-01-15 Time 10:50 Sent To  
Notes
2008-01-15 11:13:09PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) THE BATHROOMS ON THE MECHANICAL PLAN PAGE M-1 WILL
 REQUIRE EXHAUST FANS, SEE 2004 FBC/M 403.2 (3). PLEASE
 CORRECT.
  
 2) PLEASE SHOW THE CFM'S AND GRILL SIZES AT ALL SUPPLY
 AIR GRILLS ON THE MECHANICAL PLAN, SEE 2004 FBC
 106.3.5
  
 3) THE OUTSIDE AIR CALCULATIONS ON THE MECHANICAL PLAN
 SHOWS 1,644 CFM'S, AND THE EQUIPMENT SCHEDULE SHOWS 500
 CFM'S. THE TWO MUST COINCIDE, SEE 2004 FBC/M 403.3.
 PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2010-05-20 Cont ID  
Sent By lwagner Date 2010-05-20 Time 13:55 Rev Time 0.00
Received By lwagner Date 2010-05-20 Time 13:19 Sent To  
Notes
2010-05-20 13:21:24*****PROVISO******
 IF SEPARATE FIXTURE LABELED LAV IS ACTUALLY AN EMPLOYEE
 LOUNGE SINK,
 THEN THE SINK SHALL COMPLY WITH 11-4.24 ACCESSIBILITY
 CODE
 SINKS SHALL BE MOUNTED WITH THE COUNTER OR RIM NO
 HIGHER THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR.
 KNEE CLEARANCE THAT IS AT LEAST 27 INCHES (685 MM)
 HIGH, 30 INCHES (760 MM) WIDE, AND 19 INCHES (485 MM)
 DEEP SHALL BE PROVIDED UNDERNEATH SINKS.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-04-15 Cont ID  
Sent By jleech Date 2008-04-15 Time 08:29 Rev Time 0.00
Received By jleech Date 2008-04-15 Time 07:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-02-15 Cont ID  
Sent By jleech Date 2008-02-15 Time 08:15 Rev Time 0.00
Received By jleech Date 2008-02-15 Time 08:10 Sent To  
Notes
2008-02-15 08:42:09 
 DENIED;
 NO P-1 WITH PLANS. PAGE A-1 DRAWING INDEX CALLS FOR A
 P-1.
 SANITARY RISER DIAGRAM IS REQUIRED. PER SECTION
 106.3.5.3(4)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-02-15 Cont ID  
Sent By jleech Date 2008-01-25 Time 08:11 Rev Time 0.00
Received By jleech Date 2008-01-25 Time 08:11 Sent To  
Notes
2008-01-25 08:15:56DENIED;
 1. PAGE P-1 IS NOT INCLUDED WITH SUBMITED PLANS. UNABLE
 TO DO PLUMBING PLAN REVIEW.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-01-14 Cont ID  
Sent By jleech Date 2008-01-14 Time 09:08 Rev Time 0.00
Received By jleech Date 2008-01-14 Time 08:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2008-04-28 Cont ID  
Sent By adavila Date 2008-04-28 Time 14:13 Rev Time 0.00
Received By adavila Date 2008-04-16 Time 10:16 Sent To  
Notes
2008-04-28 14:13:59PER JOHN ROACH, SENIOR PLANNER, ON BEHALF OF ERIC
 SCHNEIDER, PRINCIPAL PLANNER.
  
 PROVISO ALL EXTERIOR SITE WORK, TO INCLUDE LANDSCAPE
 WORK AND RESTRIPING OF PARKING SPACES, SHALL BE
 APPROVED AND COMPLETED PRIOR TO OBTAINING THE
 CERTIFICATE OF OCCUPANCY (CO) FOR THIS PERMIT.
  

Review Stop Z ZONING
Rev No 3 Status F Date 2008-02-19 Cont ID  
Sent By adavila Date 2008-02-19 Time 11:55 Rev Time 0.00
Received By adavila Date 2008-02-13 Time 10:03 Sent To  
Notes
2008-02-19 11:55:48PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1.REPEAT COMMENTS FROM LAST REVIEW.
  
 JANUARY 25, 2008 ZONING COMMENTS:
  
 1. ONE OF THE FOLLOWING SHALL BE SUBMITTED:
 A. A LANDSCAPE PLAN, PREPARED, SIGNED AND SEALED BY A
 FLORIDA REGISTERED LANDSCAPE ARCHITECT, SHALL BE
 SUBMITTED WITH THIS PERMIT APPLICATION; OR
 B. A SITE WORK PERMIT FOR THE LANDSCAPE WORK PRIOR TO
 THE ISSUANCE OF THIS BUILDING PERMIT.
  
 2. PLEASE CONTACT ROBERT KUSSNER, LANDSCAPE PLANNER,
 FOR ALTERNATIVE TREE SPECIES.
  
 3. PLEASE NOTE THAT LANDSCAPE WORK SHALL BE APPROVED
 AND PLACED ON THE PROPERTY PRIOR TO OBTAINING THE
 CERTIFICATE OF OCCUPANCY (?CO?) FOR THIS PERMIT.
  
 4. PURSUANT TO SECTION 94-35(C) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS, ZONING COMPLIANCE SHALL BE
 DETERMINED BY THE PLANNING AND ZONING ADMINISTRATOR
 PRIOR TO ISSUANCE OF A BUILDING PERMIT TO ALLOW THE
 CONSTRUCTION, RENOVATION, ALTERATION, ADDITION TO, OR
 MOVING OF ANY BUILDING OR STRUCTURE.
 A. PARKING SPACES SHALL BE DOUBLE-STRIPED PER THE
 ZONING REGULATIONS PRIOR TO OBTAINING A CO, INCLUDING
 HANDICAP PARKING SPACE(S).A NOTE STATING SUCH SHALL
 BE ADDED TO THE PLANS.
 B. DUMPSTER ENCLOSURE MEETING THE ZONING REGULATIONS
 SHALL BE PROVIDED.
 C. TREES AND LANDSCAPE AREAS SHALL BE REPLACED ON
 SITE.
  
 COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2008-01-25 Cont ID  
Sent By adavila Date 2008-01-25 Time 17:55 Rev Time 0.00
Received By adavila Date 2008-01-25 Time 12:21 Sent To  
Notes
2008-01-25 17:55:25PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. ONE OF THE FOLLOWING SHALL BE SUBMITTED:
 A. A LANDSCAPE PLAN, PREPARED, SIGNED AND SEALED BY A
 FLORIDA REGISTERED LANDSCAPE ARCHITECT, SHALL BE
 SUBMITTED WITH THIS PERMIT APPLICATION; OR
 B. A SITE WORK PERMIT FOR THE LANDSCAPE WORK PRIOR TO
 THE ISSUANCE OF THIS BUILDING PERMIT.
  
 2. PLEASE CONTACT ROBERT KUSSNER, LANDSCAPE PLANNER,
 FOR ALTERNATIVE TREE SPECIES.
  
 3. PLEASE NOTE THAT LANDSCAPE WORK SHALL BE APPROVED
 AND PLACED ON THE PROPERTY PRIOR TO OBTAINING THE
 CERTIFICATE OF OCCUPANCY (?CO?) FOR THIS PERMIT.
  
 4. PURSUANT TO SECTION 94-35(C) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS, ZONING COMPLIANCE SHALL BE
 DETERMINED BY THE PLANNING AND ZONING ADMINISTRATOR
 PRIOR TO ISSUANCE OF A BUILDING PERMIT TO ALLOW THE
 CONSTRUCTION, RENOVATION, ALTERATION, ADDITION TO, OR
 MOVING OF ANY BUILDING OR STRUCTURE.
 A. PARKING SPACES SHALL BE DOUBLE-STRIPED PER THE
 ZONING REGULATIONS PRIOR TO OBTAINING A CO, INCLUDING
 HANDICAP PARKING SPACE(S).A NOTE STATING SUCH SHALL
 BE ADDED TO THE PLANS.
 B. DUMPSTER ENCLOSURE MEETING THE ZONING REGULATIONS
 SHALL BE PROVIDED.
 C. TREES AND LANDSCAPE AREAS SHALL BE REPLACED ON
 SITE.
  
 COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.
2008-01-25 12:22:07IN ZONING FOR REVIEW.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-01-15 Cont ID  
Sent By adavila Date 2008-01-15 Time 17:51 Rev Time 0.00
Received By adavila Date 2008-01-15 Time 17:51 Sent To  
Notes
2008-01-15 17:52:11PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PURSUANT TO SECTION 94-35(I) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS, FAILURE TO COMPLETE AND
 MAINTAIN ALL APPROVED ELEMENTS OF AN APPROVED SITE
 PLAN, INCLUDING LANDSCAPE, APPEARANCE, AND OTHER SITE
 DEVELOPMENT FEATURES, SHALL BE A VIOLATION OF THIS
 CHAPTER SUBJECT TO ENFORCEMENT AND PENALTY PROCEDURES
 OF THIS ZONING CODE.IT CAME TO STAFF?S ATTENTION THAT
 A SITE PLAN WAS APPROVED IN 1980, WHICH INCLUDED
 LANDSCAPING ON THE FRONT PARKING LOT AND ALONG THE
 NORTHWEST PROPERTY LINE.THE PLANNING AND ZONING
 DEPARTMENT HAS NO RECORDS OF A TREE ALTERATION PERMIT
 APPROVED FOR THIS SITE.AS A RESULT, PREVIOUSLY
 APPROVED TREES AND LANDSCAPING SHALL BE REPLACED ON
 SITE.
 A. SUBMIT A LANDSCAPE PLAN, PREPARED SIGNED AND SEALED
 BY A FLORIDA REGISTERED LANDSCAPE ARCHITECT, FOR
 REVIEW.
 B. CONTACT APRIL PICCIRILLO, CONSTRUCTION SERVICES
 DEPARTMENT, FOR A COPY OF THE PREVIOUSLY APPROVED PLANS
 FOR THIS SITE.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.