| Plan Review Stops For Permit 08010251 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-01-30 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
|
Date |
2008-04-29 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2010-05-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-05-25 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-05-25 |
Time |
18:08 |
Sent To |
|
|
| Notes |
| 2010-05-25 18:12:23 | APPROVED RE-STAMP UNDER 2007 FBC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-02-19 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-02-19 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-01-29 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-01-29 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-01-16 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-01-16 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2010-05-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-05-27 |
Time |
06:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-05-27 |
Time |
05:58 |
Sent To |
B |
|
| Notes |
| 2010-05-27 06:25:35 | T LUIS DESK./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-09 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-09 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2008-04-09 11:13:06 | ALL MAINS GROUPED PER 230.72 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-15 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-15 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2008-02-15 11:19:30 | *** DENIED3RD REVIEW*** | | | | | | ** PLEASE SEE SOME ITEMS WHICH ARE THE SAME FROM THE | | | TWO PREVIOUS REVIEWS ARE STILL IN NEED OF ADDRESSING. | | | | | | 1) NOTE: PLEASE SEE THE TWO PREVIOUS REVIEWS STATED NEC | | | 230.72 FOR GROUPING OF MAINS AND TO SHOW THE LOCATION | | | OF ALL EQUIPMENT ON PLANS. | | | PLEASE SEE THE RISER AND PLANS STILL SHOW THE NEW MCB | | | PANEL FOR UNIT 101 IN THE UNIT WHICH DOES NOT GROUP | | | MAINS AS REQUIRED PER CODE. | | | PLEASE RELOCATE AND COMPLETE RISER WITH ALL | | | INFORMATION. | | | 240.24, 110.26, 230.72 ETC | | | ** KEEP IN MIND AS ADDING A NEW MAIN OUTSIDE GROUPED | | | WITH OTHER MAINS WILL BE REQUIRED, PLEASE BE SURE TO | | | INCLUDE ALL CODE COMPLIANCE INFORMATION FOR NEW | | | DISCONNECT INCLUDING AN EQUIPMENT GROUNDING CONDUCTOR | | | FROM NEW MAIN TO PANEL INSIDE. | | | | | | 2) NOTE: PLEASE SEE PREVIOUS NOTES REQUESTED TO SHOW | | | THE LOCATION OF THE REQUIRED SIGN CIRCUIT. THE PANEL | | | SCHEDULE SHOWS THE REQUIRED CIRCUIT HOWEVER THE | | | ELECTRICAL PLANS STILL DO NOT SHOW THIS LOCATION. | | | PLEASE SEE 600.5 | | | | | | 3) NOTE: PLEASE SEE ATTACHED PRINT OUT OF FLORIDA | | | STATUTES 553.80(2)(B) WITH RESPECT TO REPEAT COMMENTS | | | FOR CODE COMPLIANCE. | | | THE SAME CODE SECTIONS FOR GROUPING OF MAINS HAVE BEEN | | | CITED THREE TIMES. THE FEE AS REQUIRED BY STATUE IS | | | ASSESSED. THIS IS A STATE STATUE AND NOT A LOCAL | | | ADMINISTRATIVE ASSESSMENT. | | | PLEASE SEE THE FEE OF $ 379.20 IS REQUIRED TO BE PAID | | | BEFORE RESUBMISSION OF PLANS. | | | | | | ** IF THERE ARE QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-29 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-29 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2008-01-29 11:51:39 | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW STILL | | | NEED TO BE ADDRESSED ALONG WITH NEW COMMENTS AS RISER | | | HAS NOW BEEN REVISED ONCE AGAIN WITH ITEMS WHICH WAS | | | NOT ON PREVIOUS PLANS. | | | | | | | | | | | | 1) NOTE: PLEASE SEE THE A ?COVER SHEET STILL INDICATE | | | SUITE/UNIT SCOPE OF WORK FOR SUITE/UNIT #102. AS THIS | | | APPLIED SCOPE OF WORK IS FOR ANOTHER SUITE/UNIT SPACE | | | PLEASE ADJUST COVER SHEET. | | | PLEASE KNOW THE ADDRESS EXTENSION OF PROJECT HAS NOT | | | YET BEEN CONFIRMED WITH THE ADDRESSING REVIEWER. PLEASE | | | KEEP IN MIND ANY CHANGES BASED ON THEIR REVIEW MAY | | | REQUIRE TITLE BLOCK ADJUSTMENTS ON OTHER SHEETS. FAC | | | 61G1-16.004, 61G15-23.002 | | | FBC 106.5, 106.1.2 ADMIN SECTION. | | | | | | 2) NOTE: PLEASE SEE AS MENTIONED AND NOTED ON PREVIOUS | | | REVIEW TO LOCATIONS OF MAINS AS PER 230.72. THIS WAS | | | NOT DONE. THE NEW MAIN CIRCUIT BREAKER PANEL FOR SUITE | | | # 101 IS SHOWN INSIDE THE UNIT WITH NO MAIN GROUPED | | | WITH OTHER MAINS OR LABELED AS REQUIRED PER 230.72, | | | 230.70, 230.71, 230.2E ETC. | | | | | | 3) NOTE: PLEASE SEE THE LOAD CALCULATIONS NOTES AND | | | MENTIONS CONDUCTORS FOR SERVICE ENTRANCE ARE RATED FOR | | | 385AMPS EACH PHASE HOWEVER BASED ON THE MINIMUM | | | REQUIREMENTS AND CONDUCTOR AMPACITIES IN THE NATIONAL | | | ELECTRICAL CODE AS WELL AS THE ADOPTED AWG STANDARD. | | | THE 350MCM CONDUCTORS ARE NOT RATED FOR 385AMPS. PLEASE | | | SEE 110.14, 310.16 AND 240.4. | | | PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS AS SHOWN | | | SHALL BE INCREASED. | | | | | | 4) NOTE: PLEASE SEE RISER CONTAINS NOTES FOR EXISTING | | | SUITE/UNIT #102 HOWEVER NOT SUCH SAME NOTES ARE SHOWN | | | FOR NEW SUITE/UNIT #101. | | | PLEASE SEE THE BOTTOM RIGHT HAND CORNER OF THE RISER | | | SHEET E-2. | | | PLEASE COMPLETE WITH NEW, SAME OR EXISTING | | | INFORMATION. | | | FBC 106.1.2, 106.3.5.1.2 ADMIN SECTIONS FOR ADDITIONAL | | | INFORMATION. | | | | | | 5) NOTE: PLEASE SEE THE LOCATION OF THE SIGN CIRCUIT | | | WAS NOT SHOWN. PER 600.5 | | | | | | ** AS SOME ITEMS ARE GOING TO CHANGE SUBSTANTIALLY, | | | THERE MAY BE NEW COMMENTS WHICH CAN NOT BE MADE AT THIS | | | TIME. | | | | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-16 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-16 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2008-01-16 08:53:33 | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SUBMIT PLANS WITH THE FOLLOWING | | | RELEVANT CODES. | | | 2004 FBC W/2007 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 (IF APPLICABLE) | | | | | | 2) NOTE: PLEASE SHOW LOCATIONS OF ALL NEW SERVICE | | | EQUIPMENT. CAN NOT VERIFY CODE COMPLIANCE WITH 240.24, | | | 110.26, 408.17 AND 230.72 | | | | | | 3) NOTE: PLEASE LABEL NEW MAINS. 230.2E. | | | PLEASE PROVIDE PANEL DESIGNATIONS OF SOME SORT. | | | EXAMPLES: PNL A, PNL B ETC. PLEASE SHOW WHAT IS NEW AND | | | WHAT EXISTS. PLEASE KNOW AS THESE PLANS ARE THEIR OWN | | | RECORD SET PLANS NEED TO SHOW ALL RELEVANT INFORMATION. | | | MAY NOT RELY ON PREVIOUS PERMITTED PLANS. | | | | | | 4) NOTE: PLEASE INCLUDE LOAD ON EXISTING SERVICE WITH | | | NEW LOADS BEING ADDED. | | | PLEASE SEE 220.87, 215.3, 230.42 | | | ALL CONTINUOUS LOADS AT 125%. | | | | | | 5) NOTE: PLEASE PROVIDE LOCATION OF NEW MAIN. 230.72 | | | | | | 6) NOTE: PLEASE PROVIDE MORE INFORMATION FOR LIGHTING | | | CONTROLS PER 13-415.1.ABC.1.1, .1.2 ETC | | | PLANS SHOW ONE OCCUPANCY SENSOR AT THE REAR OF SPACE | | | AND NO CONTROLS AT OTHER LOCATIONS. | | | HOW WILL COVERAGE BE MET IN THE FRONT SPACE AS IT IS | | | CONSIDERED SEPARATE FROM REAR? | | | | | | 7) NOTE: PLEASE SEE THE LOCATION OF THE REQUIRED SIGN | | | CIRCUIT IS NOT SHOWN ON PLANS. | | | 600.5 | | | | | | 8) NOTE: PLEASE KNOW AN EQUIPMENT GROUNDING CONDUCTOR | | | WILL BE REQUIRED IN ANY EMT CONDUITS UNLESS SPECIFIC | | | FITTING WHERE ARE NOW REQUIRED TO BE *LISTED* FOR | | | *EQUIPMENT GROUNDING* IS USED AND INSTALLED. THIS IS | | | NOTED NOW FOR INFORMATION WHICH MAY PREVENT REVISED | | | PLANS AT A LATER DATE. | | | 110.3, 250.110, 250.122, ETC | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2010-07-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-07-26 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-07-26 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2010-06-02 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-06-02 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-06-02 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2010-06-02 11:06:29 | *****APPROVED***** | | | | | | PLAN SHEETS A-2 AND E-1 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-02-01 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-02-01 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2008-02-01 14:00:34 | STAMPED SHEET A-2 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-01-16 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-16 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2010-05-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-05-05 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-05-05 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2010-05-05 08:34:25 | SENT TO L. MARTINEZ DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-07 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-07 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2008-04-07 16:36:18 | TO "BOB"#9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-08 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-08 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2008-02-08 16:19:39 | TO "BOB"#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-23 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-23 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2008-01-23 10:49:24 | TO "BOB"#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-01-16 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-11 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2008-01-11 10:31:11 | TO BOB # 10 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-04-29 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-04-29 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2010-05-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-05-25 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-05-25 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2010-05-25 13:03:41 | PASS PROVISO | | | 1) PLEASE REFER TO SECTION 601.4 BALANCED RETURN AIR | | | 2007 FBC (M) . EXCEPTION # 3 HABITABLE ROOMS ONLY | | | BATHROOMS , CLOSETS , STORAGE ROOMS AND LAUNDRY ROOMS | | | ARE NOT HABITABLE ROOMS . | | | 2) PLEASE REFER TO SECTION 301.12 WIND RESISTANCE . | | | MECHANICAL EQUIPMENT APPLIANCES AND SUPPORTS THAT ARE | | | EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO | | | RESIST THE WIND PRESSURES . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-23 |
Time |
16:12 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-01-23 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-15 |
Time |
10:50 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-01-15 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2008-01-15 11:13:09 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE BATHROOMS ON THE MECHANICAL PLAN PAGE M-1 WILL | | | REQUIRE EXHAUST FANS, SEE 2004 FBC/M 403.2 (3). PLEASE | | | CORRECT. | | | | | | 2) PLEASE SHOW THE CFM'S AND GRILL SIZES AT ALL SUPPLY | | | AIR GRILLS ON THE MECHANICAL PLAN, SEE 2004 FBC | | | 106.3.5 | | | | | | 3) THE OUTSIDE AIR CALCULATIONS ON THE MECHANICAL PLAN | | | SHOWS 1,644 CFM'S, AND THE EQUIPMENT SCHEDULE SHOWS 500 | | | CFM'S. THE TWO MUST COINCIDE, SEE 2004 FBC/M 403.3. | | | PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2010-05-20 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-05-20 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-05-20 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2010-05-20 13:21:24 | *****PROVISO****** | | | IF SEPARATE FIXTURE LABELED LAV IS ACTUALLY AN EMPLOYEE | | | LOUNGE SINK, | | | THEN THE SINK SHALL COMPLY WITH 11-4.24 ACCESSIBILITY | | | CODE | | | SINKS SHALL BE MOUNTED WITH THE COUNTER OR RIM NO | | | HIGHER THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR. | | | KNEE CLEARANCE THAT IS AT LEAST 27 INCHES (685 MM) | | | HIGH, 30 INCHES (760 MM) WIDE, AND 19 INCHES (485 MM) | | | DEEP SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-15 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-15 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-02-15 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-02-15 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2008-02-15 08:42:09 | | | | DENIED; | | | NO P-1 WITH PLANS. PAGE A-1 DRAWING INDEX CALLS FOR A | | | P-1. | | | SANITARY RISER DIAGRAM IS REQUIRED. PER SECTION | | | 106.3.5.3(4) | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-25 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-25 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2008-01-25 08:15:56 | DENIED; | | | 1. PAGE P-1 IS NOT INCLUDED WITH SUBMITED PLANS. UNABLE | | | TO DO PLUMBING PLAN REVIEW. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2008-01-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-14 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-14 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-04-28 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-04-16 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2008-04-28 14:13:59 | PER JOHN ROACH, SENIOR PLANNER, ON BEHALF OF ERIC | | | SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PROVISO ALL EXTERIOR SITE WORK, TO INCLUDE LANDSCAPE | | | WORK AND RESTRIPING OF PARKING SPACES, SHALL BE | | | APPROVED AND COMPLETED PRIOR TO OBTAINING THE | | | CERTIFICATE OF OCCUPANCY (CO) FOR THIS PERMIT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-02-19 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-02-13 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2008-02-19 11:55:48 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1.REPEAT COMMENTS FROM LAST REVIEW. | | | | | | JANUARY 25, 2008 ZONING COMMENTS: | | | | | | 1. ONE OF THE FOLLOWING SHALL BE SUBMITTED: | | | A. A LANDSCAPE PLAN, PREPARED, SIGNED AND SEALED BY A | | | FLORIDA REGISTERED LANDSCAPE ARCHITECT, SHALL BE | | | SUBMITTED WITH THIS PERMIT APPLICATION; OR | | | B. A SITE WORK PERMIT FOR THE LANDSCAPE WORK PRIOR TO | | | THE ISSUANCE OF THIS BUILDING PERMIT. | | | | | | 2. PLEASE CONTACT ROBERT KUSSNER, LANDSCAPE PLANNER, | | | FOR ALTERNATIVE TREE SPECIES. | | | | | | 3. PLEASE NOTE THAT LANDSCAPE WORK SHALL BE APPROVED | | | AND PLACED ON THE PROPERTY PRIOR TO OBTAINING THE | | | CERTIFICATE OF OCCUPANCY (?CO?) FOR THIS PERMIT. | | | | | | 4. PURSUANT TO SECTION 94-35(C) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, ZONING COMPLIANCE SHALL BE | | | DETERMINED BY THE PLANNING AND ZONING ADMINISTRATOR | | | PRIOR TO ISSUANCE OF A BUILDING PERMIT TO ALLOW THE | | | CONSTRUCTION, RENOVATION, ALTERATION, ADDITION TO, OR | | | MOVING OF ANY BUILDING OR STRUCTURE. | | | A. PARKING SPACES SHALL BE DOUBLE-STRIPED PER THE | | | ZONING REGULATIONS PRIOR TO OBTAINING A CO, INCLUDING | | | HANDICAP PARKING SPACE(S).A NOTE STATING SUCH SHALL | | | BE ADDED TO THE PLANS. | | | B. DUMPSTER ENCLOSURE MEETING THE ZONING REGULATIONS | | | SHALL BE PROVIDED. | | | C. TREES AND LANDSCAPE AREAS SHALL BE REPLACED ON | | | SITE. | | | | | | COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-01-25 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-01-25 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2008-01-25 17:55:25 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. ONE OF THE FOLLOWING SHALL BE SUBMITTED: | | | A. A LANDSCAPE PLAN, PREPARED, SIGNED AND SEALED BY A | | | FLORIDA REGISTERED LANDSCAPE ARCHITECT, SHALL BE | | | SUBMITTED WITH THIS PERMIT APPLICATION; OR | | | B. A SITE WORK PERMIT FOR THE LANDSCAPE WORK PRIOR TO | | | THE ISSUANCE OF THIS BUILDING PERMIT. | | | | | | 2. PLEASE CONTACT ROBERT KUSSNER, LANDSCAPE PLANNER, | | | FOR ALTERNATIVE TREE SPECIES. | | | | | | 3. PLEASE NOTE THAT LANDSCAPE WORK SHALL BE APPROVED | | | AND PLACED ON THE PROPERTY PRIOR TO OBTAINING THE | | | CERTIFICATE OF OCCUPANCY (?CO?) FOR THIS PERMIT. | | | | | | 4. PURSUANT TO SECTION 94-35(C) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, ZONING COMPLIANCE SHALL BE | | | DETERMINED BY THE PLANNING AND ZONING ADMINISTRATOR | | | PRIOR TO ISSUANCE OF A BUILDING PERMIT TO ALLOW THE | | | CONSTRUCTION, RENOVATION, ALTERATION, ADDITION TO, OR | | | MOVING OF ANY BUILDING OR STRUCTURE. | | | A. PARKING SPACES SHALL BE DOUBLE-STRIPED PER THE | | | ZONING REGULATIONS PRIOR TO OBTAINING A CO, INCLUDING | | | HANDICAP PARKING SPACE(S).A NOTE STATING SUCH SHALL | | | BE ADDED TO THE PLANS. | | | B. DUMPSTER ENCLOSURE MEETING THE ZONING REGULATIONS | | | SHALL BE PROVIDED. | | | C. TREES AND LANDSCAPE AREAS SHALL BE REPLACED ON | | | SITE. | | | | | | COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. | | 2008-01-25 12:22:07 | IN ZONING FOR REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-01-15 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-01-15 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2008-01-15 17:52:11 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PURSUANT TO SECTION 94-35(I) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, FAILURE TO COMPLETE AND | | | MAINTAIN ALL APPROVED ELEMENTS OF AN APPROVED SITE | | | PLAN, INCLUDING LANDSCAPE, APPEARANCE, AND OTHER SITE | | | DEVELOPMENT FEATURES, SHALL BE A VIOLATION OF THIS | | | CHAPTER SUBJECT TO ENFORCEMENT AND PENALTY PROCEDURES | | | OF THIS ZONING CODE.IT CAME TO STAFF?S ATTENTION THAT | | | A SITE PLAN WAS APPROVED IN 1980, WHICH INCLUDED | | | LANDSCAPING ON THE FRONT PARKING LOT AND ALONG THE | | | NORTHWEST PROPERTY LINE.THE PLANNING AND ZONING | | | DEPARTMENT HAS NO RECORDS OF A TREE ALTERATION PERMIT | | | APPROVED FOR THIS SITE.AS A RESULT, PREVIOUSLY | | | APPROVED TREES AND LANDSCAPING SHALL BE REPLACED ON | | | SITE. | | | A. SUBMIT A LANDSCAPE PLAN, PREPARED SIGNED AND SEALED | | | BY A FLORIDA REGISTERED LANDSCAPE ARCHITECT, FOR | | | REVIEW. | | | B. CONTACT APRIL PICCIRILLO, CONSTRUCTION SERVICES | | | DEPARTMENT, FOR A COPY OF THE PREVIOUSLY APPROVED PLANS | | | FOR THIS SITE. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|