Plan Review Details - Permit 08010223
Plan Review Stops For Permit 08010223
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-03-11 Cont ID  
Sent By shill Date 2008-03-11 Time 14:28 Rev Time 0.00
Received By shill Date 2008-03-11 Time 14:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-03-10 Cont ID  
Sent By shill Date 2008-03-10 Time 15:25 Rev Time 0.00
Received By shill Date 2008-03-10 Time 15:25 Sent To  
Notes
2008-03-10 15:28:02****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.THE SPAN TUBE ENGINEERING REQUIRES A 3" EDGE
 DISTANCE FOR OPENING 5, 2 1/2" SPECIFIED ON THE
 INSTALLATION SCHEDULE.PLEASE REVISE EITHER THE
 INSTALLATION SCHEDULE OR THE ENGINEERING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-02-05 Cont ID  
Sent By shill Date 2008-02-05 Time 09:56 Rev Time 0.00
Received By shill Date 2008-02-05 Time 09:56 Sent To  
Notes
2008-02-05 09:57:58****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.SEE ENGINEERING FOR THE SPAN TUBE.2 1/2" EDGE
 DISTANCE REQUIRED; INSTALLATION SCHEDULE SPECIFIES 2".
 PLEASE REVISE.
  
 2.SEE OPENING 1.A 2" EDGE DISTANCE REQUIRES A
 FACTOR OF .5, SEE SHEET 14.THEREFORE A 5' SPACING IS
 REQUIRED, NOT 10" AS SPECIFIED ON THE INSTALLATION
 SCHEDULE.PLEASE CHECK ALL OPENINGS AND REVISE.THIS
 COMMENT APPLIES TO OTHER OPENINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-17 Cont ID  
Sent By shill Date 2008-01-17 Time 17:59 Rev Time 0.00
Received By shill Date 2008-01-17 Time 17:59 Sent To  
Notes
2008-01-17 18:01:20****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 1.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), FBC
 R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE C
 HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.WORST CASE DESIGN PRESSURES WOULD BE
 -46.22 FOR ZONE 4, -57.112 FOR ZONE 5.
  
 2.PLEASE REVISE THE INSTALLATION SCHEDULE TO DESIGN
 TO EXPOSURE C PRESSURES.
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-03-04 Cont ID  
Sent By adarroug Date 2008-03-04 Time 14:35 Rev Time 0.00
Received By adarroug Date 2008-03-04 Time 14:35 Sent To B
Notes
2008-03-04 14:35:44TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-02-04 Cont ID  
Sent By shill Date 2008-02-04 Time 16:45 Rev Time 0.00
Received By shill Date 2008-02-04 Time 16:45 Sent To B
Notes
2008-02-04 16:45:32TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-01-17 Cont ID  
Sent By shill Date 2008-01-17 Time 18:01 Rev Time 0.00
Received By shill Date 2008-01-10 Time 19:20 Sent To  
Notes
2008-01-10 19:20:41SENT MISC BOX #01 MMILLER