Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-03-06 Cont ID  
Sent By shill Date 2008-03-06 Time 17:51 Rev Time 0.00
Received By shill Date 2008-03-06 Time 17:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-01-15 Cont ID  
Sent By shill Date 2008-01-15 Time 14:06 Rev Time 0.00
Received By shill Date 2008-01-15 Time 14:06 Sent To  
Notes
2008-01-15 14:07:46****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1.ADDRESSED.
  
 2..)FOR THE LOW SLOPE ROOF, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 2ND REVIEW, THE ASSEMBLY SELECTED REFERS TO GENERAL
 LIMITATION #9.THIS DOES NOT ALLOW FOR ENHANCED
 FASTENING, AND THE SYSTEM DOES NOT MEET REQUIRED DESIGN
 PRESSURES FOR ZONES 2 AND 3.
  
 3.)SEE PRODUCT LIMITATION #7.CALCULATIONS PREPARED
 BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
 4.)ADDRESSED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-03 Cont ID  
Sent By shill Date 2008-01-03 Time 16:52 Rev Time 0.00
Received By shill Date 2008-01-03 Time 16:52 Sent To  
Notes
2008-01-03 16:54:13****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.THE PERMIT FOR THE SUNROOM HAS NOT YET BEEN ISSUED.
 PLEASE PUT THIS APPLICATION WITH THE RESUB FOR THE
 SUNROOM.BOTH PERMITS WILL BE ISSUED SIMULTANEOUSLY.
  
 2..)FOR THE LOW SLOPE ROOF, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 3.)SEE PRODUCT LIMITATION #7.CALCULATIONS PREPARED
 BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
 4.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 IN ADDITION TO THE EVALUATION REPORT SUBMITTED,
 FAC9B72.WWW.FLORIDABUILDING.ORG
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-01-08 Cont ID  
Sent By adarroug Date 2008-01-08 Time 16:25 Rev Time 0.00
Received By adarroug Date 2008-01-08 Time 16:25 Sent To B
Notes
2008-01-08 16:25:32TO "SHILL" DESK/RESUB