Plan Review Details - Permit 07120596
Plan Review Stops For Permit 07120596
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-01-10 Cont ID  
Sent By shill Date 2008-01-10 Time 18:40 Rev Time 0.00
Received By shill Date 2008-01-10 Time 18:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-01-10 Cont ID  
Sent By shill Date 2008-01-10 Time 11:01 Rev Time 0.00
Received By shill Date 2008-01-10 Time 11:01 Sent To  
Notes
2008-01-10 11:03:21****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.TAMKO TW MOISTURE WRAP IS NOT APPROVED FOR USE ON
 ROOF SHEATHING, PER THE MANUFACTURER'S SPECS.
  
 2.PLEASE CONFIRM WHICH APPROVED ASSEMBLY YOU ARE
 USING.
  
 **NOTE** INFORMED CONTRACTOR THAT PLANS WOULD REMAIN ON
 MY DESK FOR 24 HOURS PENDING A RESPONSE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-01-03 Cont ID  
Sent By shill Date 2008-01-03 Time 17:26 Rev Time 0.00
Received By shill Date 2008-01-03 Time 17:26 Sent To  
Notes
2008-01-03 17:31:52****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 _XX_1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER
 BARRIER REQUIRED FS553.844(5)(A). PROVIDE
 INFORMATION (PRODUCT APPROVAL OR SPECIFICATIONS) TO
 SHOW HOW YOU WILL COMPLY WITH THIS REQUIREMENT.
 INFORMATION IS AVAILABLE AT WWW.BOAF.NET, HURRICANE
 MITIGATION.PROVIDE DETAILED INFORMATION FOR BOTH THE
 PITCH ROOF.
  
 PLEASE DESCRIBE THE SYSTEMS YOU ARE USING, FOR THE
 SINGLES AND FOR THE FLAT DECK.METHOD OF COMPLIANCE
 WITH FS553.844(5)(A), SECONDARY WATER BARRIER, TO BE
 SPECIFIED FOR EACH SYSTEM.
  
 _XX_4.)FOR THE LOW SLOPE ROOF, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 MULEHIDE TILE UNDERLAYMENT, TAMKO UNDERLAYMENT WERE
 SUBMITTED.WHICH ARE YOU USING?YOU'VE CIRCLED TILE
 UNDERLAYMENT SYSTEM FOR MULEHIDE.TAMKO TW IS ALSO A
 TILE UNDERLAYMENT.
  
 THE ASSEMBLY SELECTED IS FOR TILE UNDERLAYMENT.SELECT
 AN ASSEMBLY FOR THE FLAT DECK.
  
 _XX_5.)FOR THE LOW SLOPE ROOF, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.THIS IS TO
 BE EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED
 ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB
 SHEET).
  
 _XX_ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
 DOCUMENTS PREPARE BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 UNLESS EXEMPTED BY FLORIDA STATUTE.YOU'VE SUBMITTED
 POLYGLASS ENGINEERING, BUT ARE NOT USING THE POLYGLASS
 PRODUCT.THE ENGINEERING IS TO BE ORIGINAL UNLESS
 EXEMPTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-12-27 Cont ID  
Sent By shill Date 2007-12-27 Time 16:09 Rev Time 0.00
Received By shill Date 2007-12-27 Time 16:09 Sent To  
Notes
2007-12-27 16:15:56****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 _XX_1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER
 BARRIER REQUIRED FS553.844(5)(A). PROVIDE
 INFORMATION (PRODUCT APPROVAL OR SPECIFICATIONS) TO
 SHOW HOW YOU WILL COMPLY WITH THIS REQUIREMENT.
 INFORMATION IS AVAILABLE AT WWW.BOAF.NET, HURRICANE
 MITIGATION.PROVIDE DETAILED INFORMATION FOR BOTH THE
 PITCH ROOF
  
 ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY;
 MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF
 EACH ROOF TYPE
  
 ____3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX_4.)FOR THE LOW SLOPE ROOF, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 _XX_5.)FOR THE LOW SLOPE ROOF, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.THIS IS TO
 BE EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED
 ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB
 SHEET).
  
 ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING.IF YOU SELECT FOAM
 ADHESIVE, PRODUCT APPROVALS REQUIRED FAC9B72.
  
 _XX_ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-01-03 Cont ID  
Sent By adarroug Date 2008-01-03 Time 10:53 Rev Time 0.00
Received By adarroug Date 2008-01-03 Time 10:53 Sent To B
Notes
2008-01-03 10:53:37TO "SHILL" DESK/RESUB


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved