Plan Review Details - Permit 07120543
Plan Review Stops For Permit 07120543
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-01-29 Cont ID  
Sent By rmcdouga Date 2008-01-29 Time 14:12 Rev Time 0.00
Received By rmcdouga Date 2008-01-29 Time 13:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2008-01-07 Cont ID  
Sent By btrobaug Date 2007-12-26 Time 16:18 Rev Time 0.00
Received By rmcdouga Date 2008-01-07 Time 15:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-01-24 Cont ID  
Sent By btrobaug Date 2008-01-24 Time 08:00 Rev Time 0.00
Received By btrobaug Date 2008-01-24 Time 06:54 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-12-26 Cont ID  
Sent By btrobaug Date 2007-12-26 Time 16:17 Rev Time 0.00
Received By btrobaug Date 2007-12-26 Time 16:05 Sent To P
Notes
2007-12-26 16:17:16 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.2. FBC.
  
 2} INDICATE THE LOCATION OF THE PANELTO BE
 CHANGED.106.3.1 FBC.
  
 3} 210.52(C)(2) ISLAND COUNTER SPACES AT LEAST ONE
 RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER
 SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR
 GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR
 GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN
 ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE
 RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE
 RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND
 INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN
 210.52(C)(4), GFI PER 210.8(A)(6).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL
 .
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-01-17 Cont ID  
Sent By shill Date 2008-01-17 Time 15:06 Rev Time 0.00
Received By shill Date 2008-01-17 Time 15:06 Sent To E
Notes
2008-01-17 15:07:08TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-01-07 Cont ID  
Sent By rmcdouga Date 2008-01-07 Time 15:43 Rev Time 0.00
Received By rmcdouga Date 2007-12-21 Time 16:29 Sent To  
Notes
2007-12-21 16:29:54SENT TO ELECTRICAL INBOX MMILLER

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-01-25 Cont ID  
Sent By mperson Date 2008-01-25 Time 15:48 Rev Time 0.00
Received By mperson Date 2008-01-25 Time 15:48 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-12-28 Cont ID  
Sent By mperson Date 2007-12-28 Time 15:21 Rev Time 0.00
Received By mperson Date 2007-12-28 Time 15:21 Sent To B
Notes
2007-12-28 15:25:43PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. MORE INFORMATION IS REQUIRED, PLEASE PROVIDE THE
 FOLLOWING INFORMATION IF IT PERTAINS TO YOUR JOB. PER
 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 A} IF PLUMBING LAYOUT IS THE SAME WITH NO CHANGES,
 PLEASE INDICATE THIS ON THE RESUBMITTED DRAWINGS.
  
 B} IF PLUMBING LAYOUT IS THE SAME AND THE PLUMBING
 FIXTURES ARE TO BE CHANGED, PLEASE INDICATE ON THE
 RESUBMITTED DRAWINGS. "EXACT FIXTURE CHANGEOUT ONLY"
 AND CLEARLY INDICATE WHAT FIXTURES ARE GOING TO BE
 CHANGED.
  
 C} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT
 FROM THE EXISTING PLEASE SUBMIT THE FOLLOWING ON
 SEPERATE DRAWINGS.
 A) EXISTING FLOOR PLAN LAYOUT.
 B) NEW PROPOSED FLOOR PLAN LAYOUT AND PLEASE FOLLOW
 WHAT IS REQUIRED IN COMMENT #2.
  
 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]