Plan Review Details - Permit 07120543
| Plan Review Stops For Permit 07120543 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-01-29 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-01-29 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-26 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-01-07 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-24 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-24 |
Time |
06:54 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-12-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-26 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-26 |
Time |
16:05 |
Sent To |
P |
|
| Notes |
| 2007-12-26 16:17:16 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.2. FBC. | | | | | | 2} INDICATE THE LOCATION OF THE PANELTO BE | | | CHANGED.106.3.1 FBC. | | | | | | 3} 210.52(C)(2) ISLAND COUNTER SPACES AT LEAST ONE | | | RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER | | | SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR | | | GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR | | | GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN | | | ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE | | | RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE | | | RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND | | | INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN | | | 210.52(C)(4), GFI PER 210.8(A)(6). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | . | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-17 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-17 |
Time |
15:06 |
Sent To |
E |
|
| Notes |
| 2008-01-17 15:07:08 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-01-07 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-12-21 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2007-12-21 16:29:54 | SENT TO ELECTRICAL INBOX MMILLER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-01-25 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-01-25 |
Time |
15:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-28 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-28 |
Time |
15:21 |
Sent To |
B |
|
| Notes |
| 2007-12-28 15:25:43 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. MORE INFORMATION IS REQUIRED, PLEASE PROVIDE THE | | | FOLLOWING INFORMATION IF IT PERTAINS TO YOUR JOB. PER | | | 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | A} IF PLUMBING LAYOUT IS THE SAME WITH NO CHANGES, | | | PLEASE INDICATE THIS ON THE RESUBMITTED DRAWINGS. | | | | | | B} IF PLUMBING LAYOUT IS THE SAME AND THE PLUMBING | | | FIXTURES ARE TO BE CHANGED, PLEASE INDICATE ON THE | | | RESUBMITTED DRAWINGS. "EXACT FIXTURE CHANGEOUT ONLY" | | | AND CLEARLY INDICATE WHAT FIXTURES ARE GOING TO BE | | | CHANGED. | | | | | | C} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT | | | FROM THE EXISTING PLEASE SUBMIT THE FOLLOWING ON | | | SEPERATE DRAWINGS. | | | A) EXISTING FLOOR PLAN LAYOUT. | | | B) NEW PROPOSED FLOOR PLAN LAYOUT AND PLEASE FOLLOW | | | WHAT IS REQUIRED IN COMMENT #2. | | | | | | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | | LOCATIONS. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
|