| 2007-12-21 16:45:52 | 2004 FBC W/2004 REVISIONS |
| | FRONT PORCH ADDITION |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) FBC 106.1.1* CITY AMENDMENTS INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL (SEE ALSO SECTION |
| | 106.3.5 ). THE PLANS THAT WERE SUBMITTED DO NOT PROVIDE |
| | ENOUGH INFORMATION. PROVIDE ELEVATION DRAWINGS SHOWING |
| | THE HEIGHT ABOVE GRADE, ETC. PROVIDE DETAILS OF THE |
| | FOUNDATION, FLOOR FRAMING, COLUMNS, BEAMS, AND ROOF |
| | FRAMING. SPECIFY ROOF SHEATHING, ROOF COVERING, FLOOR |
| | DECKING, ETC. SPECIFY THE WOOD CONNECTORS, STRAPS, |
| | HANGERS, HURRICANE TIES, TRUSS ANCHORS THAT WILL BE |
| | USED TO PROVIDE A CONTINUOUS LOAD PATH FROM THE ROOF TO |
| | THE FOUNDATION AS REQUIRED BY FBC R301.1 AND R601.2. |
| | PROVIDE DETAILS OF THE FOOTINGS OR THE ANCHORING OF THE |
| | WOOD POSTS. (2 COPIES REQUIRED) |
| | |
| | 2) THE PRINTED NAME AND SIGNATURE OF THE PERSON |
| | RESPONSIBLE IS REQUIRED TO BE ON THE PLANS. SEE FBC |
| | 106.1.3* CITY AMENDMENTS. |
| | |
| | 3) SUBMIT 2 COPIES OF THE PRODUCT APPROVALS FOR THE |
| | ROOF COVERING MATERIAL AND HURRICANE CONNECTORS AS |
| | REQUIRED BY FAC RULE 9B-72. |
| | |
| | 4)106.3* PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 5) PROVIDE DETAILS OF THE STAIRS SHOWING COMPLIANCE |
| | WITH FBC R311.5.3 FOR RISERS AND TREADS. R311.5.3.1 |
| | RISER HEIGHT. |
| | THE MAXIMUM RISER HEIGHT SHALL BE 7-3/4 INCHES (196 |
| | MM). THE RISER SHALL BE MEASURED VERTICALLY BETWEEN |
| | LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST |
| | RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT |
| | EXCEED THE SMALLEST BY MORE THAN 3/8 INCH.R311.5.3.2 |
| | TREAD DEPTH. |
| | THE MINIMUM TREAD DEPTH, EXCLUSIVE OF NOSING, SHALL BE |
| | NOT LESS THAN 9 INCHES (229 MM). TREADS AND RISERS OF |
| | STAIRS SHALL BE PERMITTED TO BE SO PROPORTIONED THAT |
| | THE SUM OF TWO RISERS AND A TREAD, EXCLUSIVE OF |
| | PROJECTION OF NOSING, IS NOT LESS THAN 24 INCHES (610 |
| | MM) NOR MORE THAN 25 INCHES (635 MM). |
| | |
| | 6) SHOW COMPLIANCE WITH R319.1.1 GROUND CONTACT. ALL |
| | WOOD IN CONTACT WITH THE GROUND AND THAT SUPPORTS |
| | PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL |
| | BE APPROVED PRESSURE PRESERVATIVE TREATED WOOD SUITABLE |
| | FOR GROUND CONTACT USE, EXCEPT UNTREATED WOOD MAY BE |
| | USED WHERE ENTIRELY BELOW GROUNDWATER LEVEL OR |
| | CONTINUOUSLY SUBMERGED IN FRESH WATER. |
| | |
| | - ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |