Plan Review Details - Permit 07120301
| Plan Review Stops For Permit 07120301 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-31 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-31 |
Time |
17:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-29 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-29 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2008-01-29 09:10:56 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1. ADDRESSED. | | | | | | 2.SEE FBC1008.1.4; THE FLOOR OR LANDING ON EACH SIDE | | | OF THE DOOR IS TO BE AT THE SAME ELEVATION. | | | | | | 2ND REVIEW, PLANS HAVE BEEN REVISED TO STATE THAT THE | | | FLOOR WILL BE LEVEL, BUT PROPOSED LANDING PLAN SHOWS A | | | 4" ELEVATION CHANGE.THIS DIMENSION IS IN CONFLICT | | | WITH OTHER DETAILS AND LANGUAGE ON THE PLAN, AND IS IN | | | CONFLICT WITH OUR TELEPHONE CONVERSATION.WITH THE | | | ARCHITECT'S PERMISSION, THIS CAN BE REDLINED. | | | | | | 3.ADDRESSED. | | | | | | 4.ADDRESSED. | | | | | | 5.PROVIDE A GUARDRAIL AND STAIR RAIL DETAIL TO SHOW | | | COMPLIANCE WITH FBC1012.3. | | | | | | 2ND REVIEW, RAMP SECTION "A", SHOWS A 2'8" DIMENSION | | | AND IS LABELED HANDRAIL.THE HANDRAIL IS NOTED AS 42". | | | IT IS NOT CLEAR WHAT THIS 2'8" DIMENSION IS FOR AS NO | | | HANDRAIL IS SHOWN GRAPHICALLY AT THIS LOCATION.AS THE | | | 42" HANDRAIL/GUARDRAIL IS CODE COMPLIANT, AN NO OTHER | | | HANDRAIL IS REQUIRED, THIS ITEM CAN BE REDLINED IF | | | REQUESTED BY ARCHITECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-02 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-02 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2008-01-02 15:43:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.PROVIDE INFORMATION REGARDING THE EXISTING BUILDING | | | AND THE PURPOSE OF THIS EXISTING DOOR.WAS THIS A | | | REQUIRED ACCESSIBLE EXIT?WHAT IS THE OCCUPANT LOAD | | | OF THE AREA SERVED? | | | | | | 2.SEE FBC1008.1.4; THE FLOOR OR LANDING ON EACH SIDE | | | OF THE DOOR IS TO BE AT THE SAME ELEVATION. | | | | | | 3.HANDRAILS ARE TO COMPLY WITH FBC1009.11 AND, IF | | | REQUIRED TO BE ACCESSIBLE, FBC11-4.9.4.NOTE THE LACK | | | OF HANDRAIL EXTENSIONS, HANDRAILS NOT CONTINUOUS. | | | | | | 4.SPECIFY DESIGN STRENGTH CRITERIA FOR GUARDRAILS AND | | | HANDRAILS, FBC1607. | | | | | | 5.PROVIDE A GUARDRAIL AND STAIR RAIL DETAIL TO SHOW | | | COMPLIANCE WITH FBC1012.3. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-18 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-18 |
Time |
11:34 |
Sent To |
Z |
|
| Notes |
| 2008-01-18 11:34:34 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-02 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-13 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2007-12-13 11:09:27 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-24 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-24 |
Time |
10:04 |
Sent To |
B |
|
| Notes |
| 2008-01-24 10:04:26 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | | | | SENT TO "B" - SH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-18 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-18 |
Time |
09:24 |
Sent To |
B |
|
| Notes |
| 2007-12-18 09:25:45 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY | | | SHOWING THE LOCATION OF THE PROPOSED, ALSO INDICATE | | | SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
|