Plan Review Details - Permit 07120275
Plan Review Stops For Permit 07120275
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-12-20 Cont ID  
Sent By mjacobs Date 2007-12-20 Time 15:55 Rev Time 0.00
Received By mjacobs Date 2007-12-20 Time 15:29 Sent To PC
Notes
2007-12-20 15:58:59BUILDING PROVISO:
 TO BE IN PLACE AT C.O:
  
 PRIVATE
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  
 PUBLIC POOLS
 424.1.3.1.9 ALL PUBLIC POOLS SHALL BE SURROUNDED BY A
 MINIMUM 48" IN HEIGHT FENCE. A SELF LATCHING SELF
 CLOSING LOCKABLE GATE OF 48" MINIMUM HEIGHT WITH THE
 LATCH LOCATED NEAR THE TOP. SAFETY COVERS THAT COMPLY
 WITH ASTM F 1346 DO NOT SATIFY THIS REQUIREMENT.
  
 13-412.1ABC2.6.2 POOL COVERS. HEATED POOLS SHALL BE
 EQUIPPED WITH A VAPOR RETARDANT POOL COVER ON OR AT THE
 WATER SURFACE. POOLS HEATED TO MORE THAN 90 DEGREES
 (F)
 SHALL HAVE A POOL COVER WITH A MINIMUM INSULATION VALUE
 OF R-12.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-12-19 Cont ID  
Sent By btrobaug Date 2007-12-19 Time 14:10 Rev Time 0.00
Received By btrobaug Date 2007-12-19 Time 14:10 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-12-19 Cont ID  
Sent By mperson Date 2007-12-19 Time 16:39 Rev Time 0.00
Received By mperson Date 2007-12-19 Time 16:39 Sent To B
Notes
2007-12-19 16:40:43CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL
 GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL
 INSPECTION.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-12-20 Time   Rev Time 0.00
Received By adarroug Date 2007-12-12 Time 16:14 Sent To  
Notes
2007-12-12 16:14:26TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-12-19 Cont ID  
Sent By mperson Date 2007-12-19 Time 16:36 Rev Time 0.00
Received By mperson Date 2007-12-19 Time 16:36 Sent To G
Notes
2007-12-19 16:39:22****************PROVISO****************
 A} FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC.
 R4101.9 WATER SUPPLY, LOCAL ORD.
 #2853-95, BACKFLOW REQUIRED ON WATER
 SERVICE.
  
 B} FBC-2004 SEC. 424.2.13.2, OR
 FBCR-2004 SEC.R4101.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING.
  
 CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL
 GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL
 INSPECTION.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2007-12-17 Cont ID  
Sent By choops Date 2007-12-17 Time 11:22 Rev Time 0.00
Received By choops Date 2007-12-17 Time 11:22 Sent To E
Notes
2007-12-17 11:22:23***APPROVED***
  
  
  
  
 SENT TO "E"