| Plan Review Stops For Permit 07120223 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-02-08 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-02-08 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-02-08 |
Time |
17:38 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-31 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-12-31 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-12-31 |
Time |
09:42 |
Sent To |
PC |
|
| Notes |
| 2007-12-31 09:49:56 | | | | DENIED | | | | | | | | | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | | AMENDMENTS PER 106.1.1 FBC* | | | | | | 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* | | | | | | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | | ADDED TO THE PERMIT APPLICATION FEES | | | | | | NOTE: FEES ARE DUE IN THE AMOUNT OF $3,782.59 FOR | | | REMAINING FEES, INCREASED VALUE AND STATE RADON FEES | | | THIS AMOUNT IS REQUIRED TO BE PAID PRIOR TO FURTHER | | | PLAN REVIEW | | | | | | 4)SURVEY AND SITE PLAN SIDE AND REAR SETBACK | | | MEASUREMENTS DO NOT MATCH EACH OTHER | | | | | | 5)PROVIDE CORRECT PROJECT ADDRESS ON THE DRAWINGS | | | (USE OF LABEL IS ACCEPTABLE), ALSO CLARIFY BUILDER AND | | | OWNER INFORMATION ON ENERGY CALC'S THEY STATE KOLTER | | | HOMES AS THE BUILDER | | | | | | 6)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | | STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. | | | THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. | | | WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE | | | DENIED | | | | | | 7) SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT | | | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR | | | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND | | | APPROVED BY THE DESIGNER OF RECORD ***PLEASE NOTE THAT | | | FLORIDA SHEETS WERE NOT SUBMITTED FOR PGT AND WAYNE | | | DALTON PRODUCTS AND THE FL#'S ARE WRITTEN AT THE TOP OF | | | THESE PRODUCT NOA'S*** | | | | | | 8)PRODUCT APPROVALS WERE NOT SUBMITTED FOR MULLIONS | | | THAT WILL BE USED ON SEVERAL DOOR AND WINDOW | | | INSTALLATIONS, ALSO PRODUCT APPROVAL FOR CASEMENT | | | WINDOWS WERE SUBMITTED BUT NONE ARE PRESENT ON THE | | | DRAWINGS, PLEASE CLARIFY | | | | | | 9)THE FIXED WINDOW IN THE DINING ROOM AREA IS 51 SQ | | | FT. AND EXCEEDS THE MAX ALLOWABLE SIZE OF 30.28 SQ FT. | | | IN THE FIXED WINDOW PRODUCT APPROVAL | | | | | | 10)CORRECT SECTION AND COLUMN DESIGNATIONS ON SHEETS | | | A/2 AND A/3 THAT REFER TO A SHEET 7 AND THAT ALSO HAVE | | | DETAIL AND SHEET NUMBERS REVERSED | | | | | | 11)CLARIFYFOUNDATIONFOR SCREEN WALL, SCHEDULE ON | | | A/2 STATES 12" X 24" FOOTING AND DETAIL OFBLOCK PIERS | | | ON SHEET A/5 SHOWS 30" X 30" PAD | | | | | | 12)CLARIFY SECTION J-6 ON SHEET A/2 AT GARAGE WALL | | | WITH DETAIL ON A/6 | | | | | | 13)CLARIFY DETAILS FOR FRAMED WALLS FROM MAIN ROOF AT | | | FRONT PORCH TO RAISED ROOF, ARE THESEDETAILS J-6, O-6 | | | AND N-6 IF SO SHOW THEORIENTATION OF SECTIONS ON THE | | | FLOOR OR ROOF PLAN. SHOW THAT BEAM ABOVE IS FRAMED INTO | | | ENTIRE PERIMETER WALL AS SHOWN ON ROOF FRAMING PLAN AND | | | IS IT BOXED OUT ON THE INSIDE ALL THE WAY AROUND AS | | | STATED ON SAME PLAN | | | | | | 14)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS | | | OF NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF | | | THE OLD PAGES ONLY FOR REFERENCE. PLEASE RE-SUBMIT ANY | | | PAGES WITH THE IMPACT FEE STAMP | | | | | | 15)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | | AMENDMENTS | | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | | AMENDMENTS TO FBC | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | FBC RES. = FLORIDA BUILDING CODE | | | RESIDENTIAL 2004 W/2006 AMENDMENTS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-24 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-24 |
Time |
14:18 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-21 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-21 |
Time |
09:28 |
Sent To |
PC |
|
| Notes |
| 2008-11-21 09:29:09 | | | | | | | | | | ** FAILED REVISION ** | | | | | | | | | | | | 1) NOTE: PLEASE SEE ITEM REDLINED ON ISSUED PLANS FROM | | | 1/28/08 THE 2005 NEC WAS REVISED TO REQUIRE ALL | | | RECEPTACLES IN LAUNDRY ROOMS TO BE GFI/GFI PROTECTED | | | WITHIN 6FT OF THE LAUNDRY SINK EVEN IF THESE ARE | | | DEDICATED RECEPTACLES. | | | THE PLANS WERE REDLINED FOR THE IRONING BOARD | | | RECEPTACLE TO MEET 210.8A7 | | | | | | 2) NOTE: PLEASE LIST/IDENTIFY THE ARC FAULT BREAKERS ON | | | PANEL SCHEDULES. | | | 210.12,408.4 | | | | | | 3) NOTE: PLEASE VERIFY THE CONDUITS FROM METER TO | | | MAINS. ARE THESE OVERHEAD AS SHOWN ON RISER OR | | | UNDERGROUND? | | | IF OVER HEAD THEN OCP IS REQUIRED ON THE OUTSIDE. | | | IF IN SLAB PLEASE SHOW. | | | 230.70 | | | | | | 4) NOTE: PLEASE SEE 210.11C2, 220.52 | | | | | | 5) NOTE: PLEASE SEE THE INCORRECT NFPA-72 IS STATED ON | | | PLANS. SHOWS 2005 AND NEEDS TO 2002. THIS WAS REDLINED | | | ON ORIGINAL PLANS. | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-28 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-28 |
Time |
09:03 |
Sent To |
P |
|
| Notes |
| 2008-01-28 09:09:30 | REDLINED PLANS. | | | | | | PREVIOUS REVIEW 210.8A7, ALL RECEPTACLES EVEN DEDICATED | | | 15/20AMP 125V WITHIN 6FT OF LAUNDRY SINK SHALL BE GFI.; | | | THIS INCLUDES IRONING BOARD RECEPT. MOST WERE OK. | | | PLANS CHANGED CODES, HOWEVER NFPA-72 WAS CHANGED TO | | | 2005 WHEN PREVIOUS REVIEWS REQUESTS 2002 NFPA-72 AS | | | ADOPTED BY FS 553.79 AND THE FLORIDA BUILDING | | | COMMISSION. THIS WAS REDLINED ON PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-23 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-23 |
Time |
13:16 |
Sent To |
P |
|
| Notes |
| 2007-12-23 13:16:23 | ** DENIEDREVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE CODES TO BE STATED ON PLANS ARE | | | NEEDED AS FOLLOWS: | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE 2005 NEC AS ALL RECEPTACLES IN A | | | LAUNDRY ROOM WITHIN 6FT OF LAUNDRY SINK ARE TO BE GFI. | | | THIS INCLUDES WASHING MACHINE. BASED ON THE SCALE OF | | | ELECTRICAL PLANS, THE SINK EDGE IS AT 6FT OR LESS. | | | PLEASE SEE 210.8A7 | | | | | | 3) NOTE: PLEASE SEE BEDROOM #3 AS ALL OUTLETS WHICH ARE | | | 15AMP OR 20AMP SHALL BE AFCI PROTECTED PER 210.12. THIS | | | INCLUDES THE GFI AND OTHER DEDICATED RECEPTACLES SHOWN | | | IN THIS ROOM. | | | | | | 4) NOTE: PLEASE SEE PANEL SCHEDULE/LOAD CALCULATIONS | | | ARE STILL SHOWING 3-#6 CONDUCTORS FOR AH UNITS AND C | | | UNITS. THESE ARE TWO POLE UNITS AND IT IS PERMITTED TO | | | INSTALLED #6 FOR THE EQUIPMENT GROUNDING CONDUCTORS | | | HOWEVER NOT REQUIRED. IF SHOWN ON PLANS, THIS IS WHAT | | | WILL BE REQUIRED TO BE INSTALLED. | | | NO CHANGE IS NEEDED FOR EQUIPMENT GROUNDING IF #6 | | | CONDUCTORS WILL BE INSTALLED. THIS IS NOTED FOR | | | INFORMATION ONLY. | | | | | | 5) NOTE: PLEASE SEE MISSING LIVING ROOM RECEPTACLE | | | ALONG MORE THAN 2FT OF WALL SPACE. (REDLINED ON ONE | | | SET) (WALL NEAR KITCHEN DOORWAY ENTERING FROM BRKFST | | | RM. | | | 210.52 | | | | | | 6) NOTE: PLEASE SEE NFPA-72 11.8.3. IF THE TRAY CEILING | | | IN OFFICE WHICH IS ALSO CONSIDERED AN ADAPTABLE BEDROOM | | | IS 12INCHES OR HIGHER, THE SA IS REQUIRED AT THE HIGH | | | POINT OF ELEVATION. (ONLY IF TRY IS 12 INCHES OR | | | GREATER). BASED ON PLANS AND ELEVATIONS SHOWN THIS IS | | | THE CASE. PLEASE ADJUST LOCATION. | | | | | | 7) NOTE: PLEASE CORRELATE ELECTRICAL PLANS AND | | | MECHANICAL PLANS FOR NUMBER OF A/C UNITS AND SIZE OF | | | HEAT STRIPS. | | | PLEASE SEE MECHANICAL PLANS CALL FOR 1-5KW, 1-10KW AND | | | 1-7.5KW WHEREAS THE ELECTRICAL PANEL SCHEDULE/LOAD | | | CALCULATIONS ONLY INDICATE TWO SYSTEMS AND BOTH AT 10KW | | | EACH FOR HEAT. | | | THIS WILL AFFECT CIRCUITING, LOADS, OVER CURRENT | | | PROTECTION ETC. | | | 408.4, 240.4, 310.16, 220, ETC | | | FBC 106.3.5.4 | | | | | | 8) NOTE: PLEASE COORDINATE PLANS AND RISER AS PLANS | | | SHOW TWO MAIN DISCONNECTS OUTSIDE AND RISER ONLY SHOWS | | | TWO PANELS INSIDE.? | | | PLEASE COORDINATE. | | | FBC 106.1.2, 106.3.5.4 | | | NEC 230.70, 230.71, 230.72 | | | | | | 9) NOTE: PLEASE VERIFY IF THE LOAD ON POOL PANEL ARE | | | ALREADY FIGURED AT 125%. | | | 215.3, 230.42 ETC | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-24 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-24 |
Time |
11:07 |
Sent To |
E |
|
| Notes |
| 2008-11-24 11:07:44 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-18 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-18 |
Time |
13:57 |
Sent To |
E |
|
| Notes |
| 2008-11-18 13:57:24 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-04 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-04 |
Time |
16:39 |
Sent To |
L |
|
| Notes |
| 2008-11-04 16:40:03 | TO "Z" BOX/SUBMITTAL--LANDSCAPING REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-17 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-17 |
Time |
11:46 |
Sent To |
Z |
|
| Notes |
| 2008-10-17 11:47:16 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-06-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-18 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-18 |
Time |
13:36 |
Sent To |
M |
|
| Notes |
| 2008-06-18 13:36:55 | TO "TGORDON" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-06 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-06 |
Time |
11:19 |
Sent To |
M |
|
| Notes |
| 2008-06-06 11:20:06 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-22 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-22 |
Time |
11:53 |
Sent To |
Z |
|
| Notes |
| 2008-01-22 11:53:37 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-12-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-12 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2007-12-12 09:21:00 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2008-11-13 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-11-13 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-11-13 |
Time |
09:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-11-05 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-11-05 |
Time |
15:58 |
Sent To |
PC |
|
| Notes |
| 2008-11-05 16:01:10 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. PLEASE SHOW THE REQUIRED STREET TREES ON THE | | | LANDSCAPE PLAN. | | | | | | 2. PLEASE CLARIFY LANDSCAPE CALCULATIONS. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-27 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-10-27 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-10-27 |
Time |
09:02 |
Sent To |
PC |
|
| Notes |
| 2008-10-27 09:07:16 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. SUBMIT 2ND COPY OF LANDSCAPE PLAN. | | | | | | 2. COMPLETE THE REQUIRED CALCULATIONS---TREES REQUIRED | | | AND PROVIDED, SHRUBS REQUIRED AND PROVIDED, ETC. | | | | | | 3. IDENTIFY AND PROVIDE THE REQUIRED STREET TREES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-23 |
Time |
08:35 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-06-23 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2008-06-23 08:36:08 | REVISION TO MECH. PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-09 |
Time |
09:47 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-06-09 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2008-06-09 10:00:18 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLANS. | | | *** DENIED *** | | | 1) COOLING LOAD CALCULATION ON FILE ARE CALLING FOR | | | 51,426 TOTAL COOLING BTU'S FOR SYSTEM 1, REVISED | | | MECHANICAL PLAN IS SHOWING MODEL NUMBERS FOR A 3 TON | | | SYSTEM AROUND 33,800 TOTAL COOLING BTU'S. (SEE ARI | | | CERTIFICATE ATTACHED). PLEASE CORRECT PLANS OR REVISE | | | COOLING LOAD CAL'S PER 2004 FBC 13-607.1.ABC.1.1. | | | | | | 2) THE SUPPLY AIR DUCT FROM AIR HANDLER #2 TO THE | | | MIXING BOX OVER THE MASTER BATHROOM NEEDS TO BE SIZED, | | | PER WPB AMEND. 106.3.5.4 (10). | | | | | | 3) PLEASE SHOW THE JOB ADDRESS ON THE PLAN, PER WPB | | | AMEND.106.1.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-21 |
Time |
12:22 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-12-21 |
Time |
12:22 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-02-06 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-02-06 |
Time |
09:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-24 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-24 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2007-12-24 09:01:36 | DENIED; | | | 1. L.T. IS NOT ON THE SAME WALL AS W/M. SEPARATE BRANCH | | | DRAIN REQUIRED. | | | 2. NO BIDET SHOWN ON RISER DIAGRAM, BUT SHOWN ON FLOOR | | | PLANS. | | | 3. DELETE W/H DIAGRAM ON SHEET A-4. INFORMATION ON | | | DIAGRAM IS NOT CORRECT. T&P WILL DISCHARGE TO THE | | | GARAGE FLOOR,HEATER IS GAS WITH A RECIRCULATION SYSTEM, | | | AND NO WATER HEATER PAN IS REQUIRED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-24 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-24 |
Time |
15:39 |
Sent To |
E |
|
| Notes |
| 2008-01-24 15:39:47 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | | | | SENT TO "E" - DP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-12 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-12 |
Time |
16:38 |
Sent To |
E |
|
| Notes |
| 2007-12-12 16:41:55 | ***FAILED*** | | | | | | | | | 1)PROPOSED DRIVEWAY DOES NOT MATCH FROM SURVEY TO | | | SHEET A6.PLEASE CLARIFY. | | | | | | 2)PROPOSED A/C UNITS DO NOT MATCH FROM SHEETS A2/A4 | | | TO A6.PLEASE CLARIFY. | | | | | | 3)PLEASE SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE | | | WITH SECTION 94-442 AND 94-445 OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|