Plan Review Details - Permit 07120085
| Plan Review Stops For Permit 07120085 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-25 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-25 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-04 |
Time |
14:34 |
Rev Time |
|
| Received By |
shill |
Date |
2008-06-03 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2008-06-04 14:39:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.REVISE APPLICATION; GOVERNING CODE IS FBC2004, NOT | | | 2005. | | | | | | 2. ADDRESSED. | | | | | | 3.AS DISCUSSED, ENGINEER HAS APPLIED FOR CERTIFICATE | | | OF AUTHORIZATION.THIS ISSUE DOES NOT DELAY THE PERMIT | | | PROCESS FOR THIS PERMIT. | | | | | | 4-5. ADDRESSED. | | | | | | 6.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | PLEASE PROVIDE THE FLORIDA STATE PRODUCT APPROVAL FOR | | | THE SLIDING GLASS DOORS.ONLY THE TEST REPORT WAS | | | SUBMITTED. | | | | | | FOR THE WINDOWS, AN EXPIRED (2001) FLORIDA STATE | | | PRODUCT APPROVAL WAS PROVIDED.PLEASE PROVIDE THE | | | CURRENT APPROVAL, IF AVAILABLE.IF THIS IS NOT | | | AVAILABLE, PLEASE CONFIRM WITH THE MANUFACTURER THAT | | | THIS NOA IS IN COMPLIANCE WITH FBC2004 AS THE OLDER | | | NOAS (ISSUED UNDER FBC2001) INCLUDED A 33% STRESS | | | INCREASE WHICH IS NOT PERMITTED IN THE CURRENT CODE. | | | SOME PRODUCTS REQUIRED AN DECREASE IN ANCHOR SPACING, | | | OTHERS REVISED THE NOA TO USE ANCHORS WITH HIGHER | | | VALUES.PLEASE CONFIRM THAT ANCHORING IS COMPLIANT | | | WITHOUT THE STRESS INCREASE. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-10 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-10 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2007-12-10 09:38:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.REVISE APPLICATION; GOVERNING CODE IS FBC2004, NOT | | | 2005. | | | | | | 2.A CERTIFICATE OF AUTHORIZATION IS REQUIRED FOR A & | | | F ENGINEERING INC., FS481.219(2) (DAVID FORKEY PE). | | | PROVIDE THE THE CERTIFICATE OF AUTHORIZATION NUMBER FOR | | | THIS COMPANY OR SUBMIT AN APPLICATION TO FBPE AS | | | REQUIRED AS THIS COMPANY HAS APPARENTLY BEEN IN | | | BUSINESS SINCE 2001. | | | | | | 3.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES FOR | | | BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED USING | | | ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN ENGINEER | | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | | ORIGINALS FAC61G15-23.002. | | | | | | 4.PROVIDE A COPY OF THE CONDO ASSOCIATION APPROVAL. | | | | | | 5.PROVIDE A FLOOR PLAN SHOWING WHERE THE SGDS AND | | | WINDOWS WILL BE INSTALLED. | | | | | | 6.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9B72, WWW.FLORIDABUILDING.ORG.INCLUDE THE | | | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS. | | | NOTHING WAS PROVIDED FOR THE WINDOWS, EVALUATION | | | REPORT/INSTALL INSTRUCTIONS WERE PROVIDED FOR THE SGD | | | BUT NOT THE FL STATE PRODUCT APPROVAL. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-12 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-12 |
Time |
10:51 |
Sent To |
B |
|
| Notes |
| 2008-06-12 10:51:27 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-02 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-02 |
Time |
12:45 |
Sent To |
B |
|
| Notes |
| 2008-06-02 12:45:42 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-10 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-06 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2007-12-06 14:38:30 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy