Plan Review Details - Permit 07110631
Plan Review Stops For Permit 07110631
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-04-25 Cont ID  
Sent By rmcdouga Date 2008-04-25 Time 10:17 Rev Time 0.00
Received By rmcdouga Date 2008-04-25 Time 07:41 Sent To  
Notes
2008-04-25 10:21:43 
 BUILDING PROVISO
  
 SUBMIT SIGNED AND SEALED DOOR BUCK FASTENING DETAILS
 FROM THE DESIGNER OF RECORD FOR THE GARAGE SIDE ENTRY
 DOOR AND THE SLIDING GLASS DOOR FOR APPROVAL PRIOR TO
 INSTALLATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-04-08 Cont ID  
Sent By rmcdouga Date 2008-04-08 Time 10:36 Rev Time 0.00
Received By rmcdouga Date 2008-04-08 Time 07:21 Sent To  
Notes
2008-04-08 10:35:562004 FBC W/2007 REVISIONS
 ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) THE REQUIRED SOIL BEARING CAPACITY SPECIFIED ON
 SHEET A2.O OF THE PLANS IS 2500 PSF. THE GEOTECHNICAL
 REPORT INDICATES A MAXIMUM ALLOWABLE BEARING OF 1500
 PSF. PLEASE RESOLVE.
  
 3) THE WIND CRITERIA ON A-1.0 SPECIFIES THE WRONG
 SECTION OF FBC 2004. THE CORRECT SECTION IS 1609.
  
 4) SPECIFY THE TRUSS BOTTOM CORD LIVE LOAD ON THE
 PLANS. FBC TABLE R301.5 SPECIFIES THE LIVE LOAD FOR
 ATTICS WITH STORAGE AS 20 PSF.
  
 5) SPECIFY THE METHOD OF TERMITE TREATMENT ON THE
 PLANS. SEE FBC 320.1.
  
 6) THE PLANS DO NOT SPECIFY THAT THE EXISTING WINDOW IN
 BEDROOM 3 THAT IS BEING REMOVED IS A FIXED WINDOW OR
 THAT THE OTHER EXISTING WINDOW IN THIS BEDROOM WHICH
 APPEARS TO BE A HORIZONTAL SLIDING WINDOW IS THE EGRESS
 WINDOW. SECTION 501.2 OF THE 2004 FBC EXISTING BUILDING
 CODE DOES NOT ALLOW EXISTING BUILDING TO BE ALTERED
 SUCH THAT THE BUILDING BECOMES ANY LESS SAFE. PLEASE
 SPECIFY THIS INFORMATION AND SHOW THAT BEDROOM 3 WILL
 COMPLY.
  
 7) THE DESIGN DATA ON SHEET A1.0 SPECIFIES EXPOSURE B.
 THE DESIGN INFORMATION ON SHEET A2.0 SPECIFIES EXPOSURE
 C. PLEASE CORRECT. FBC 106.1.1* CITY AMENDMENTS.
  
 8) PROVIDE BUCK FASTENING DETAILS FOR THE GARAGE SIDE
 ENTRY DOOR AND THE SLIDING GLASS DOOR. SEE FBC
 R613.1.1. THE PRODUCT APPROVALS FOR THE FRONT DOOR DOES
 PROVIDE BUCK FASTENING DETAILS. HOWEVER, THE PRODUCT
 APPROVALS FOR OTHER DOORS REQUIRE THE DESIGNER OF
 RECORD TO SPECIFY THE BUCK ATTACHMENT.
  
 9)ON SHEET A-2.0 THE MEAN ROOF HEIGHT IS SPECIFIED AS
 14 FEET ABOVE MEAN SEA LEVEL. THIS IS NOT CORRECT. THE
 MEAN ROOF HEIGHT IS TAKEN FROM FINAL GRADE.
  
 10) ON SHEET A4.0 THE UPLIFT CONNECTORS SPECIFIED FOR
 THE ROOF TRUSSES ARE SIMPSON MTS12. THESE ARE WOOD TO
 WOOD CONNECTORS. THE PLANS APPEAR SHOW A 2X PLATE ON
 THE TIE BEAM BUT DOES NOT SPECIFY HOW IT IS ATTACHED.
 THE MTS STRAPS REQUIRE 7 NAILS TO THE TRUSS AND 7 TO
 THE WALL. ONE 2X WILL NOT PROVIDE ADEQUATE SURFACE FOR
 NAILING. ANOTHER TYPE OF ANCHOR SUCH AS A HMTSM 16 FOR
 ATTACHING TO MASONRY/CONCRETE COULD BE USED.SPECIFY
 THE NUMBER AND TYPE OF FASTENERS.
  
 10) THE NOTE ON A4.0 FOR THE MTS 12 STATES THAT THE
 UPLIFT EXCEEDS THE LOADS ON SHEET A2.0. THE ONLY
 UPLIFTS SPECIFIED ON A2.0 ARE FOR THE COMPONENTS AND
 CLADDING. UPLIFTS ON THE TRUSSES ARE DIFFERENT AND
 SUBSTANTIALLY HIGHER.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-12-18 Cont ID  
Sent By rmcdouga Date 2007-12-18 Time 11:01 Rev Time 0.00
Received By rmcdouga Date 2007-12-17 Time 13:16 Sent To  
Notes
2007-12-17 16:55:212004 FBC W/2007 REVISIONS
 LEVEL 2 ALTERATIONS AND ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED. NOTE: WORK MUST COMMENCE WITHIN
 90 DAYS OF RECORDING DATE.
  
 2)THE PROJECT IS LOCATED IN AN AREA WITH SOILS HAVING
 A QUESTIONABLE BEARING CAPACITY. SUBMIT A GEO-TECHNICAL
 EVALUATION SOIL REPORT. SEE FBC R401.4.
  
 3) NO WHITE-OUT IS ALLOWED ON THE PLANS. SEE FBC
 106.1.3* CITY AMENDMENTS.
  
 4) THE CONSTRUCTION TYPE SPECIFIED ON SHEET A-1.0 IS
 INCORRECT. THE CONSTRUCTION TYPE IS V-B, TYPE VI IS NO
 LONGER IN THE CODE. SEE FBC 310.
  
 5) THE WIND CRITERIA SPECIFIED AS FBC 2001, SECTION
 1606ON A-1.0 IS INCORRECT. SEE FBC R301.2.1.
  
 6) ON SHEET A-1.0, THE EDITION OF THE FBC IS
 INCORRECTLY SPECIFIED AS 2001. THE APPLICABLE CODE IS
 THE 2004 FBC.
  
 7) SPECIFY THE TRUSS BOTTOM CORD LIVE LOAD ON THE
 PLANS. FBC TABLE R301.5 SPECIFIES THE LIVE LOAD FOR
 ATTICS WITH STORAGE AS 20 PSF.
  
 8) SPECIFY WHAT METHOD OF TERMITE PROTECTION WILL BE
 USED. SEE FBC R320.1.
  
 9) ON SHEET A-2.0 THE STRUCTURAL NOTES SPECIFY THE
 WRONG ACI EDITIONS. THE 2004 FBC REFERENCES ACI 315-02
 AND ACI 530-05.
  
 10) SHOW COMPLIANCE WITH FBC R310.1 FOR EMERGENCY
 ESCAPE AND RESCUE OPENINGS IN THE BEDROOM ADJACENT TO
 THE GARAGE ADDITION.
  
 11) PROVIDE BUCK FASTENING DETAILS FOR THE SWING,
 SLIDING AND OVERHEAD GARAGE DOORS. SEE FBC R613.1.1.
  
 12)SHOW COMPLIANCE WITH FBC R905.2.2 SLOPE.
 ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF
 TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR
 GREATER. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12
 UNITS HORIZONTAL (2:12) UP TO FOUR UNITS VERTICAL IN 12
 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT
 COMPLYING WITH ASTM D 226 TYPE I OR TYPE II, ASTM D
 4869 TYPE I OR TYPE II OR ASTM D 6757 IS REQUIRED IN
 ACCORDANCE WITH SECTION R905.2.7 .
  
 13) PLEASE CLARIFY SECTION 1 ON A-4.0 WHICH SPECIFIES
 ANCHORING EACH TRUSS BOTTOM CORD WITH SIMPSON LTT19
 ANCHORS. THEY APPEAR TO BE ANCHORED TO HOLLOW BLOCK.
 ALSO, CLARIFY WHAT IS OPTI-MESH 6" LONG? FBC 106.1.1*
 CITY AMENDMENTS.
  
 14) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 15) THE PRODUCT APPROVAL DRAWING, FL-618, SUBMITTED FOR
 THE THERMA-TRU DOORS IS FOR THE FRAME ATTACHMENT AND
 REQUIRES A SEPARATE PRODUCT APPROVAL FOR THE DOOR
 PRODUCT. SEE GENERAL NOTES 2, 3 AND 6 ON SHEET 1 OF 3.
  
 16) SPECIFY THE MOUNT TYPE AND FASTENING OPTION THAT
 WILL BE USED TO INSTALL THE STORM PANELS ON THE FRONT
 DOOR W/SIDELITES. CIRCLE THE APPROPRIATE ITEMS ON THE
 NOA.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-03-28 Cont ID  
Sent By btrobaug Date 2008-03-28 Time 16:09 Rev Time 0.00
Received By btrobaug Date 2008-03-28 Time 16:04 Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-12-03 Cont ID  
Sent By btrobaug Date 2007-12-03 Time 11:12 Rev Time 0.00
Received By rmcdouga Date 2007-12-17 Time 13:15 Sent To B
Notes
2007-12-03 11:12:10 
  
 APPLICATION #07110631
 ELECTRICAL PLAN REVIEW
 116 WORTH COURT N
 12/3/07
 WEST PALM BEACH, FL.
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
 ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE
 NOTED.
  
  
 1} CIRCUIT # A-32 INDICATED FOR THE GARAGE RECEPTACLES
 IS LISTED AS CU ON THE PANEL SCHEDULE. CORRELATE SAME.
 106.1.3. FBC.
  
 2} INDICATE THE RATING (AMPERAGE) OF THE ELECTRICAL
 SERVICE. 215.5 NEC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-12-03 Cont ID  
Sent By ssherman Date 2007-12-03 Time 16:27 Rev Time 0.00
Received By ssherman Date 2007-12-03 Time 16:27 Sent To  
Notes
2007-12-03 16:27:54HISTORICAL APPROVAL PER GALINA JUDGE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-04-24 Cont ID  
Sent By adarroug Date 2008-04-24 Time 08:40 Rev Time 0.00
Received By adarroug Date 2008-04-24 Time 08:40 Sent To B
Notes
2008-04-24 08:41:15TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-03-28 Cont ID  
Sent By adarroug Date 2008-03-28 Time 14:14 Rev Time 0.00
Received By adarroug Date 2008-03-28 Time 14:14 Sent To Z
Notes
2008-03-28 14:18:20TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-03-28 Cont ID  
Sent By rmcdouga Date 2007-12-18 Time 11:01 Rev Time 0.00
Received By adarroug Date 2007-11-27 Time 15:48 Sent To  
Notes
2007-11-27 15:48:34TO "SFR" "Z"

Review Stop Z ZONING
Rev No 2 Status P Date 2008-03-28 Cont ID  
Sent By choops Date 2008-03-28 Time 16:57 Rev Time 0.00
Received By choops Date 2008-03-28 Time 16:57 Sent To B
Notes
2008-03-28 16:59:17***APPROVED - RESUB #1***
  
 PROVISO:TOTAL IMPERMEABLE SURFACE WITHIN THE FRONT
 YARD (FRONT PROPERTY LINE TO THE FRONT FACADE OF THE
 BUILDING) SHALL NOT EXCEED 875 SQUARE FEET.
  
  
  
  
 SENT TO "B" - RMC

Review Stop Z ZONING
Rev No 1 Status F Date 2007-11-30 Cont ID  
Sent By choops Date 2007-11-30 Time 08:23 Rev Time 0.00
Received By choops Date 2007-11-30 Time 08:23 Sent To E
Notes
2007-11-30 08:40:34***FAILED***
  
  
 1)ALL DEMOLITION MUST BE REVIEWED AND APPROVED BY
 HISTORIC PRESERVATION (5TH FLOOR, CITY HALL).
  
 2)PROVIDE SQUARE FOOTAGE OF ALL PROPOSED
 DRIVEWAY/WALKWAYS (INCLUDING ANY EXISTING TO REMAIN)
 WITHIN THE FRONT YARD (FRONT PROPERTY LINE TO THE FRONT
 OF THE PROPOSED GARAGE).MUST MAINTAIN 75% OR 1,000
 SQ.FT. (WHICHEVER IS LESS) OF LANDSCAPE MATERIAL WITHIN
 THE FRONT YARD.875 SQUARE FEET OF IMPERMEABLE SURFACE
 PERMITTED WITHIN THE FRONT YARD.
  
 3)REMOVE ANY FENCE OR OBJECT ON PLANS THAT IS TO BE
 PERMITTED SEPARATELY.
  
 4)ALL PROPOSED COLUMNS, FENCES, WALLS, GATES, ETC.
 SHALL OBTAIN AN APPROVED EASEMENT CONSENT FORM FROM THE
 CITY'S DEPARTMENT OF PUBLIC UTILITIES (1ST FLOOR, CITY
 HALL).
  
 5)PLANS SHALL CONTAIN NO WHITE OUT.
  
 6)PROPOSED COLUMNS EXCEED MAXIMUM HEIGHT ALLOWABLE.
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION 94-302(B)(1): MAXIMUM
 HEIGHT.IN RESIDENTIAL DISTRICTS, NO FENCE OR WALL
 SHALL EXCEED SIX FEET IN HEIGHT WITHIN REQUIRED SIDE
 AND REAR SETBACKS. FENCES OR WALLS SHALL NOT BE IN
 EXCESS OF 48 INCHES IN HEIGHT WITHIN THE REQUIRED FRONT
 SETBACK. HEDGES SHALL NOT EXCEED TEN FEET IN HEIGHT IN
 ANY REQUIRED SETBACK.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720