| 2007-11-27 13:06:44 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | 1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER BARRIER |
| | REQUIRED FS553.844(5)(A). |
| | |
| | THE APPLICATION STATES THAT YOU ARE USING GLASPLY 4 AS |
| | THE SECONDARY WATER BARRIER.THIS IS NOT COMPLIANT |
| | WITH THE REQUIREMENTS; SEE THE FS553.844 AND |
| | WWW.BOAF.NET.YOU MAY USE AN APPROVED CAP SHEET SUCH |
| | AS RUBBEROID MOP SMOOTH OR RUBBEROID 20 AS THE |
| | SECONDARY WATER BARRIER OR COMPLY IN ANOTHER WAY SUCH |
| | AS TAPING THE PLYWOOD JOINTS OR FULL DECK COVERAGE. |
| | |
| | SECONDARY WATER BARRIER IS REQUIRED FOR THE SHINGLED |
| | AREA ALSO.PLEASE PROVIDE SPEC SHEET OR PRODUCT |
| | APPROVAL. |
| | |
| | IF YOU ELECT TO TAPE THE PLYWOOD JOINTS, PLEASE BE |
| | ADVISED THAT 4" IS REQUIRED BY CODE, BUT 6" IS REQUIRED |
| | BY SOME INSURANCE COMPANIES.A PERMIT WILL BE ISSUED |
| | FOR 4" TAPE BUT CONTRACTOR IS ASKED TO ADVISE THE |
| | HOMEOWNER OF THIS INFORMATION PRIOR TO MAKING A |
| | DECISION. |
| | |
| | 2.)PLEASE REVISE THE ENHANCED FASTENING LETTER TO |
| | INCLUDE ZONE II (PERIMETER).THE LETTER STATES ZONE |
| | III, PERIMETER AND CORNER.THIS SHOULD READ ZONES II |
| | AND III, PERIMETER AND CORNER. |