| Plan Review Stops For Permit 07110597 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-01-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-03 |
Time |
11:29 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-01-03 |
Time |
11:29 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-12 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-02-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-05 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-05 |
Time |
17:47 |
Sent To |
PC |
|
| Notes |
| 2008-02-05 17:50:26 | REVISED SHEETS S-1, E-1 AND E-2 | | | SHEET S-1 WAS FOR REVISION OF ELEC ONLY, STILL NEED TO | | | USE ORIGINAL PLANS FOR ANY STAMPS OR REVIEWED ITEMS | | | FROM OTHER TRADES. | | | | | | REDLINED SHEET E-1 AS THE RISER HAS BEEN REVISED FOR | | | NEW CONDUCTORS FROM MAIN TO FPL TRANSFORMER AND NOW | | | SHOWS NEW *EQUIPMENT GROUNDING CONDUCTORS* FROM FPL TO | | | FIRST MEANS OF DISCONNECT WHICH IS NOT PERMITTED. | | | PLEASE SEE 250.6 AND 250.24 . IF THESE ARE INSTALLED | | | THIS WOULD CREATE OBJECTIONABLE CURRENTS WHICH IS NOT | | | PERMITTED BUT ALSO A SAFETY ISSUE WITH SERVICE. PLEASE | | | REMOVE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-30 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-30 |
Time |
17:57 |
Sent To |
PC |
|
| Notes |
| 2008-01-30 17:57:26 | ** DENIED REVIEW/REVISION ** | | | | | | 1) NOTE: PLEASE SUBMIT A COMPLETE SET OF REVISED PLANS. | | | PLEASE SEE THE EXISTING SHEETS S-1, E-1 STILL SHOW | | | INFORMATION, LOCATIONS, AND EQUIPMENT WHICH IS NOT THAT | | | OF THE EQUIPMENT ON-SITE OR THE EQUIPMENT LISTED ON | | | E-2. | | | PLEASE SEE THE ATS SPECIFIED ON SHEET E-2 DOES NOT | | | CORRELATE WITH THAT OF THE SHEETS E-1 OR S-1 AND DOES | | | NOT MATCH WITH THE MANUFACTURES SPECS/CUT SHEETS. | | | PLEASE SUBMIT NEW PLANS AND NEW CUT SHEETS FOR ANY AND | | | ALL CHANGES IN EQUIPMENT AND SPECS. | | | 110.3, 90.7 NFPA-70 2005 | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 2) NOTE: PLEASE COMPLETE TITLE BLOCK INFORMATION FOR | | | ENGINEER OF RECORD. PLEASE SEE AFC 61G15-23.002 FOR ALL | | | REQUIRED INFORMATION SUCH AS PRINTED NAME , ADDRESS, | | | PHONE , LICENSE ETC | | | SOME INFORMATION IS SHOWN BUT NOT ALL. | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-20 |
Time |
19:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-20 |
Time |
19:58 |
Sent To |
|
|
| Notes |
| 2007-12-20 20:04:12 | THE PRINTED NAME AND LICENSE # OF THE ENGINEER WAS | | | STILL MISSING ON TITLE BLOCKS PER FAC 61G15-23.002 | | | THIS WAS WRITTEN ON SHEETS BY REVIEWER. | | | | | | REDLINED 702.11 AS THE DISCONNECTING MEANS TO MEET | | | 225.31-225.39AND 702.11 EXCEPTION SHALL BE READILY | | | ACCESSIBLE, AND MEET 110.27. | | | | | | ONLY ONE SET OF ATS SPECS AND GEN SPECS SUBMITTED WHICH | | | WERE ATTACHED TO OLD PLANS.MADE COPIES FOR 2ND SET | | | AND ATTACHED TO NEW SETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-10 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-10 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2007-12-10 12:22:15 | **** DENIED **** | | | | | | 1) NOTE: PLEASE SEE THE FOLLOWING CODES SHALL BE STATED | | | ON PLANS. MAY NOT STATE *LATEST CODE*. | | | PLEASE LIST THE FOLLOWING AS ADOPTED BY THE FLORIDA | | | STATUTES. | | | 2004 FBC W/2007 REVISIONS. | | | 2002 NFPA-110 | | | 2003 NFPA-101 | | | 2005 NFPA-70 | | | | | | 2) NOTE: PLEASE KNOW BASED ON RECENT INFORMATION FROM | | | THE STATE THE LICENSE WHICH MUST BE USED TO APPLY FOR | | | INSTALL AND DEAL NATURAL GAS OR LP. | | | PLEASE PROVIDE LICENSING FOR INSTALL/SALES OF UNIT. | | | PLEASE SEE FS 527.02 | | | | | | 3) NOTE: PLEASE SEE PLANS INDICATE THE GENERATOR AS | | | EXISTING IN TWO DIFFERENT LOCATIONS. PLEASE CLEARLY | | | INDICATE WHERE THE NEW GENERATOR IS BEING INSTALLED. | | | PLEASE SEE NFPA-110CHAPTER 7 FOR LOCATION | | | INSTALLATIONS. | | | | | | 4) NOTE: PLEASE CLARIFY THE LOADS OF THE GENERATOR. | | | PLEASE SEE RISER NOTES THERE WILL BE A MANUAL TRANSFER | | | SWITCH HOWEVER PLANS ALSO NOTE THERE WILL BE A AN | | | AUTOMATED TRANSFER SWITCH. WHICH ONE IS BEING | | | INSTALLED? | | | PLEASE KNOW IF THERE ARE ANY LIFE SAFETY OR LEGALLY | | | REQUIRED LOADS BEING FED FROM THIS SOURCE AS THE | | | PRIMARY BACK UP, THEN ON-SITE FUEL IS REQUIRED PER | | | 701.11B3 AND 700.12B3. | | | PLEASE KNOW IF THERE IS ANY LIFE SAFETY AND LEGALLY | | | REQUIRED LOADS SERVED PLEASE SEE 700.6, 701.7 FOR | | | TRANSFER EQUIPMENT | | | | | | 5) NOTE: PLEASE SEE THE RISER IS NOW SHOWING A NEW MAIN | | | DISCONNECT BEING INSTALLED ON WHAT APPEARS TO BE THE | | | LINE SIDE OF THE PREVIOUS MAIN SERVICE SWITCHGEAR. | | | PLEASE SEE NEC 110.9 AND SUBMIT AIC RATINGS FOR ANY NEW | | | SERVICE EQUIPMENT. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 6) NOTE: PLEASE SEENOT ALL SHEETS ARE SIGNED, DATED | | | AND SEALED BY THE DESIGNER OF RECORD AS REQUIRED PER FS | | | 471.003, 471.025 | | | | | | 7) NOTE: PLEASE COMPLETE INFORMATION ON TITLE BLOCKS | | | FOR ALL SHEETS AS REQUIRED PER FAC 61G15-23.002 | | | PLEASE SEE MISSING PRINTED NAME AND PRINTED LICENSE | | | NUMBER OF THE ENGINEER OF RECORD. | | | | | | 8) NOTE: PLEASE SEE THE SIZING OF CONDUCTORS MAY ONLY | | | USE THE 75 DEGREE COLUMN AS 110.14 ONLY CONTAINS A | | | RATING FOR LUGS. | | | PLEASE KNOW DE-RATING MAY BE USE 90 DEGREE COLUMN. | | | | | | 9) NOTE: PLEASE INCLUDE CONDUCTORS FROM NEW MAIN TO | | | FPL. | | | 230, 310.16, 240.4 | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-12-28 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-12-28 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2007-12-28 14:42:26 | NEW SHEET SIGNED AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-12-24 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-12-24 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2007-12-24 09:23:00 | 1) PLEASE ADD NOTE REGARDING COMPLIANCE WITH NFPA 101, | | | 2003, AND NFPA 110, 2002 WHEN RESUBMITTING FOR OTHER | | | REVIEW CORRECTIONS. | | | | | | 2) REMOVE NOTE REGARDING NO LIFE SAFETY BEING TIED INTO | | | GENERATOR IF STATEMENT IS INCORRECT AS PER OUR | | | CONVERSATION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-12-18 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-12-18 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2007-12-18 13:50:45 | ***DENIED*** | | | | | | 1) WORK TO COMPLY WITH NFPA 101, 2003 EDITION AND NFPA | | | 110, 2002 EDITION IN ADDITION TO APPLICABLE BUILDING | | | CODES. | | | | | | 2) PLEASE VERIFY ACTUAL LOCATION OF NEW GENERATOR. | | | PLANS SHOW THE EXISTING GENERATOR IN THE MAIN | | | ELECTRICAL ROOM AND A GENERATOR PAD IS ILLUSTRATED | | | OUTSIDE ON THE EAST SIDE OF THE BUILDING. | | | | | | 3) WHAT BUILDING LIFE SAFETY EQUIPMENT WILL BE TIED | | | INTO NEW GENERATOR? | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
N |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-12-12 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-12-12 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2007-12-12 08:45:10 | NO FUEL REVIEW. NATURAL GAS ONLY. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-28 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-28 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2007-12-28 14:08:12 | FIELD VERIFY ALL CLEARANCES. MINIMUM 3' REQUIRED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-21 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-21 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2007-12-21 09:52:30 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | | | | 2. SHT S-1 INDICATES SHT 1 OF 2, BUT NO SHT 2 | | | SUBMITTED. PLEAE CLARIFY. SECTION 106.1.1. | | | ****NO RESPONSE, NOT ADDRESSED. ALSO ALL THREE SHEETS | | | ARE INDICATED AS SHEET E-2 OF 2 IN THE TITLE BLOCK. | | | PLEASE CLARIFY. | | | | | | 3. OK | | | 4. OK | | | | | | 5. SHT S-1 INDICATE THE MEASUREMENT OFF ALL STRUCTURES | | | TO THE SIDES OF THE GENERATOR. (WALLS & BUILDING). | | | SECTION 106.1.2. | | | ****NO RESPONSE, NOT ADDRESSED. | | | | | | 6. SUBMIT THE INSTALLATION INSTRUCTIONS FOR THE | | | GENERATOR SHOWING REQUIRED CLEARANCE ON ALL SIDES OF | | | THE GENERATOR FOR SERVICE ETC. SECTION 106.1.2. | | | ****RESPONSE WAS THE SUBMITTAL OF A SINGLE SHEET THAT | | | DOES NOT INDICATE WHAT BRAND OR MODEL GENERATOR THE | | | SHEET IS FOR. ALSO 3' IS HAND WRITTEN ON THE SHEET, BUT | | | NOT FROM THE MANUFACTURE. PLEASE SUBMIT THE COMPLETE | | | INSTRALLTAION INSTRUCTIONS FOR THE GENERATOR BEING | | | INSTALLED. CLEARANCES FROM ALL STRUCTURES SHALL BE | | | INDICATED. | | | | | | 7. THE GENERATOR SHALL BE LISTED. PLEASE SUBMIT | | | INFORMATION SHOWING REQUIRED LISTING. SECTION 301.3 | | | FUEL GAS CODE. | | | ****NO RESPONSE, NOT ADDRESSED. | | | | | | 8. OK DEDICATED METER | | | 9. OK | | | 10. OK | | | 11. OK | | | 12. OK | | | | | | **********NEW COMMENT********** | | | | | | 1B. SEE ATTACHED SHEET CONCERNING THE DESIGN | | | PROFESSIONAL AND FS 553.80(2)(B). THIS IS GIVEN AS A | | | NOTICE ONLY AT THIS TIME. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-11 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-11 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2007-12-11 09:23:29 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. INDICATE THE CODE IN EFFECT AT THE TIME OF DESIGN. | | | (FBC-2004 W/2007 AMENDMENTS) | | | | | | 2. SHT S-1 INDICATES SHT 1 OF 2, BUT NO SHT 2 | | | SUBMITTED. PLEAE CLARIFY. SECTION 106.1.1. | | | | | | 3. SHTS S-1, E-1 & E-2 THE ENGINEER SHALL LEGIBLY | | | INDICATE THEIR NAME AND LICENSE NUMBER ON EACH SHEET. | | | FAC 61G15-23.002(2) & FS 471.025. | | | | | | 4. SHT E-2 SHALL BE SIGNED, SEALED, DATED AS REQUIRED | | | BY FLORIDA STATUTES & SECTION 106.1. | | | | | | 5. SHT S-1 INDICATE THE MEASUREMENT OFF ALL STRUCTURES | | | TO THE SIDES OF THE GENERATOR. (WALLS & BUILDING). | | | SECTION 106.1.2. | | | | | | 6. SUBMIT THE INSTALLATION INSTRUCTIONS FOR THE | | | GENERATOR SHOWING REQUIRED CLEARANCE ON ALL SIDES OF | | | THE GENERATOR FOR SERVICE ETC. SECTION 106.1.2. | | | | | | 7. THE GENERATOR SHALL BE LISTED. PLEASE SUBMIT | | | INFORMATION SHOWING REQUIRED LISTING. SECTION 301.3 | | | FUEL GAS CODE. | | | | | | 8. PLEASE INDICATE IF THE GAS METER IS A DEDICATED | | | METER FOR THE GENERATOR ONLY. IF NOT PLEASE INDICATE | | | THE TOTAL BTU LOAD ON THE SYSTEM, AND SHOW THE TOTAL | | | DEVELOPED LENGTH FOR ALL OTHER GAS LINES OFF THE METER. | | | INDICATE WHERE THE OTHER GAS LINE CONNECTS AT THE | | | METER. | | | | | | 9. GAS ISOMETRIC SHEET SHOWS A CLOCK VALVE. PLEASE | | | INDICATE WHAT A CLOCK VALVE IS AND SUBMIT MANUF. | | | SPECIFICATION FOR THE CLOCK VALVE. | | | | | | 10. GAS ISOMETRIC SHEET A SHUT OFF VALVE AND UNION ARE | | | REQUIRED IMMEDIATELY UPSTREAM OF THE REGULATOR. SECTION | | | 409.4. | | | | | | 11. THE PRINTED NAME AND SIGNATURE OF THE PERSON | | | DESIGNING THE GAS PIPING SHALL BE ON THE GAS ISOMETRIC | | | RISER DIAGRAM. SECTION 106.1.3. | | | | | | 12. SUBMIT THE MANUF SPECIFICATION SHEETS FOR THE GAS | | | REGULATOR. INDICATE THE MODEL NUMBER USED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-01 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-01 |
Time |
16:24 |
Sent To |
E |
|
| Notes |
| 2008-02-01 16:24:49 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-23 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-23 |
Time |
12:17 |
Sent To |
E |
|
| Notes |
| 2008-01-23 12:17:42 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-27 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-27 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2007-12-27 15:32:30 | TO "BOB" # 6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-27 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-27 |
Time |
11:35 |
Sent To |
G |
|
| Notes |
| 2007-12-27 11:35:59 | TO KEN STEVENS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-20 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2007-12-20 17:51:26 | SENT TO COM BOARD # 01 MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-17 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-27 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2007-12-07 11:17:29 | 12/7/07 TO "COMM" BD#58--EXPEDITED-- | | 2007-11-27 14:54:37 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-12-12 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-12-12 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2007-12-12 08:43:25 | NO MECHANICAL REVIEW. NATURAL GAS ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2007-12-07 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2007-12-07 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|