| Plan Review Stops For Permit 07110587 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-12 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-12-12 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2007-12-12 11:43:18 | PERMIT ASSIGNED TO THE NEW UNIT ADDRESS 115 FOR THE NEW | | | RESTAURANT . | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-05-05 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-05-05 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2008-05-05 14:40:04 | REVISED SHEET A1 DATED 4/30/08 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-25 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-25 |
Time |
10:04 |
Sent To |
M |
|
| Notes |
| 2008-04-25 10:14:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.IT APPEARS THAT THE RAMP SHOWN ON A1 (ADJACENT TO | | | MECH 108) HAS BEEN REPLACED BY STAIRS.PROVIDE RISE | | | AND RUN, FBC1009.3.IF THIS IS NOT A STAIR, PROVIDE | | | INFORMATION AS TO WHAT IS GRAPHICALLY SHOWN ON THE PLAN | | | AND HOW THE ELEVATION CHANGE WAS ADDRESSED. | | | | | | 2.HANDRAILS REQUIRED ON BOTH SIDES, FBC1009.11, | | | FBC11-4.9.4.SHOW ON THE FLOOR PLAN AND PROVIDE A | | | DETAIL, INCLUDING EXTENSIONS. | | | | | | 3.MEANS OF EGRESS IN COMPLIANCE WITH FBC CHAPTER 10 | | | IS TO BE PROVIDED TO ALL PORTIONS OF BUILDINGS, | | | FBC1001.1.A PARTIAL WALL WAS CONSTRUCTED; SHOW | | | DISTANCE BETWEEN WALLS (SPACE AVAILABLE FOR EGRESS | | | PATH). | | | | | | 4,THE CHAGES ON A1 AFFECT OTHER SHEETS.PLEASE | | | REVISE. | | | | | | 5.THIS IS A FULLY SPRINKLERED BUILDING.PLEASE | | | ADDRESS ON THE PLAN HOW THE NEW WALLS AFFECT THE | | | EXISTING SPRINKLERS. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-02-12 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-02-12 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-07 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-07 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2007-12-07 10:50:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.REGARDING THE DOUBLE DOORS ADJACENT TO THE | | | BATHROOMS, SEE FBC11-4.13.4.PLEASE SHOW COMPLIANCE | | | AND DIMENSIONS ON THE PLAN. | | | | | | 2.THIS IS A FULLY SPRINKLERED BUILDNG.HOW DOES THE | | | NEW WALL IN THE STORAGE AREA AFFECT THE FIRE SPRINKLER | | | LAYOUT?IF REQUIRED, SUBMIT A PLAN. | | | | | | 3.MECHANICAL PLANS SHOW A TENANT SEPARATION WALL | | | WHICH DOES NOT YET EXIST.SEE PERMIT NUMBER 07080934. | | | THIS IS STILL UNDER APPLICATION.PLEASE ADDRESS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-01 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-01 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2008-02-01 16:37:43 | PLANS STAMPED ON PREVIOUS REVIEW. SUITE/UNIT NUMBER WAS | | | ADDED TO TITLE BLOCKS. | | | | | | *** ALL EXISTING ELECTRICAL SHWON ON PLANS WITH | | | EXCEPTION OF ONE NEW CIRCUIT FOR NEW LIGHTS. NO REVIEW | | | DONE ON EXISTING ELECTRICA. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-05 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-05 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2007-12-06 15:54:07 | ELECTRICAL PLANS ARE OK, HOWEVER ADDRESS IS AN ISSUE | | | AND WILL BECOME FAILED BY THE ADDRESSING REVIEWER. ONCE | | | THE CORRECT ADDRESS FOR SUITE/UNIT NUMBER HAS BEEN | | | DETERMINED AND SIGNED OFF BY ADDRESSING THE SUITE/UNIT | | | # MAY BE ADDED TO TITLE BLOCKS. THERE IS NO NEED TO | | | REPRINT ELECTRICAL SHEETS FOR THIS. | | 2007-12-05 16:29:37 | NO REVIEW DONE ON ANY ELECTRICAL WHICH IS SHOWN AS ALL | | | EXISITNG BY THE ENGINEER OF RECORD. | | | ONLY ADDING ONE NEW CIRCUIT FOR 10LTS AND RELOCATING | | | AHU DISCONNECT. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-21 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-21 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2008-02-21 10:56:58 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS PLAN REVIEW HAVE BEEN | | | ADDRESSED;PLAN SHEETS A2, A3, ANDE2 WERE STAMPED, | | | INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-24 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-24 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2007-12-24 15:48:49 | *****DENIED***** | | | | | | 01.THE SUITE NUMBER SHALL BE INCLUDED WITH THE | | | NUMERICAL ADDRESS LOCATED IN THE TITLE BLOCK OF EACH | | | SUBMITTED PLAN SHEET. | | | | | | 02.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 03.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 04.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS | | | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT | | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 05.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE | | | WITH EMERGENCY RESPONSE ACCESS TO THE SAID PROPERTY OR | | | THE VICINITY THEREOF (INCLUDING STREETS, ROADS, FIRE | | | LANES). | | | | | | 06.PROVIDE THE OCCUPANT LOAD , AS IN THE NUMBERS OF | | | PERSONS FOR WHOM MEANS OF EGRESS AND OTHER PROVISIONS | | | ARE REQUIRED. | | | | | | 07.PLEASE SHOW TRAVEL DISTANCE TO EXITS ON THE LIFE | | | SAFETY PLAN SHEET. | | | | | | 08.ANY DOOR IN A REQUIRED MENS OF EGRESSFROM AN | | | AREA HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS | | | SHALL BE PROVIDED WITH PANIC HARDWARE OR FIRE EXIT | | | HARDWARE. | | | | | | 09.SPECIFY THE INTERIOR FINISH MATERIALS FOR THE NEW | | | WALLS IN TERRMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 10.PLANS DON' T INDICATE IF THE PROJECT SITE IS FIRE | | | SPRINKLERED.IF SO SPRINKLERED AND THERE IS A CAUSE | | | FOR THIS SYSTEM TO BE ALTERED DUE TO THE SCOPE OF WORK, | | | SEPARATE PLANS AND PERMIT WILL BE REQUIRED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-08 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-08 |
Time |
13:10 |
Sent To |
PC |
|
| Notes |
| 2008-04-08 13:11:45 | REVISION: "OK" SHEET P1 GAS RISER. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-04 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-04 |
Time |
11:17 |
Sent To |
PC |
|
| Notes |
| 2008-04-04 13:14:33 | GAS PLAN REVIEW: | | | REVISION DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET P1 GAS RISER: THE CUT SECTIONS OF PIPE FROM | | | THE METER TO THE SEDIMENT TRAP DO NOT HAVE | | | CORRESPONDING LENGTHS INDICATED. THE DISTANCE FROM THE | | | POINT OF DELIVERY TO THE MOST DISTANT OUTLET IN | | | INCORRECTLY BEING INDICATED AS 100 FEET. THE CALCULATED | | | DISTANCE OF THE INDICATED CUT SECTIONS CORRESPONDING | | | LENGTHS IS NOW 105 FEET AND THATS WITHOUT THE CUT | | | SECTIONS FROM THE METER TO THE SEDIMENT TRAP. PLEASE | | | CORRECT PLANS WITH ALL CORRESPONDING LENGTHS TO ALL CUT | | | SECTIONS OF PIPE AND THE CORRECT LONGEST LENGTH OF THE | | | SYSYEM. PER FBC FUEL GAS 401.1 SCOPE. | | | | | | 2. SHEET P1 GAS RISER: THE GAS BRANCH SUPPLY TO THE | | | FOLLOWING APPLIANCES ARE INCORRECTLY SIZED. PLEASE | | | CORRECT PER FBC FUEL GAS TABLE 402.4 (2). PLEASE | | | REFERENCE FBC FUEL GAS TABLE 402.4(2) ATTACHED TO THESE | | | COMMENTS FOR THE NEXT REVISION SUBMITTAL. | | | | | | A} ITEM #18, SHOULD BE 1 INCH. | | | | | | B} ITEM #19, SHOULD BE 1-1/4 INCH. | | | | | | C} ITEM #27, SHOULD BE 1 INCH. | | | | | | D} ITEM #32, SHOULD BE 1 INCH. | | | | | | E} ITEM #29, SHOULD BE 1-1/4 INCH. | | | | | | F} ITEM #30, SHOULD BE 1-1/4 INCH. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-29 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-29 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2008-02-29 14:29:45 | SEPARATE GAS PERMIT REQUIRED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-22 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-22 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2008-02-22 18:16:44 | DENIED--FROM PREVIOUS REVIEW:SEE COMMENTS FROM | | | PLUMBING PLAN REVIEW. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-14 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-14 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2008-02-22 18:15:52 | DENIED.--SEE COMMENTS IN THE PLUMBING PLAN REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-02 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-02 |
Time |
08:45 |
Sent To |
B |
|
| Notes |
| 2008-05-02 08:45:49 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-09 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-09 |
Time |
08:43 |
Sent To |
B |
|
| Notes |
| 2008-04-09 08:43:48 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-08 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-08 |
Time |
09:35 |
Sent To |
G |
|
| Notes |
| 2008-04-08 09:36:38 | TO "G" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-03 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-03 |
Time |
13:18 |
Sent To |
G |
|
| Notes |
| 2008-04-03 13:18:59 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-28 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-28 |
Time |
10:37 |
Sent To |
P |
|
| Notes |
| 2008-02-28 10:37:31 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-29 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-29 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2008-01-29 11:24:04 | TO "COMM" BD#46 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-24 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-27 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2007-11-30 16:22:59 | TO "COMM" BD#18 | | 2007-11-27 11:16:15 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-04-26 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2008-04-26 09:33:01 | MECH DESIGN NOT AFFECTED BY ARCHITECTURAL REVISION #2 | | | ON PAGE A1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-02-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-02-16 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-02-16 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-12-07 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-12-07 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2007-12-07 14:16:12 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 AMENDMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PG M1: ON THE ?RELOCATED? SIDE OF THE PLAN, AHU 2 IS | | | SHOWN AT BOTH THE EXISTING LOCATION AND THE NEW | | | LOCATION. PLEASE SHOW THE AHU ONLY IN THE NEW LOCATION | | | FOR CLARIFICATION OF THE SCOPE OF WORK. FBC 106.1.1 | | | | | | 2. PG M1: MECHANICAL NOTE #13 CALLS FOR CONDENSATE | | | DISPOSAL IN THE ROOF DRAIN. HOW IS CONDENSATE FOR AN | | | AHU ON THE 1ST FLOOR TO DRAIN ON THE ROOF? PLEASE SHOW | | | MEANS OF CONDENSATE DISPOSAL IN ACCORDANCE WITH FBC, M | | | 307.2.1. ALSO, SHOW MEANS OF AUXILIARY DRAIN PROTECTION | | | PER FBC, M 307.2.3. | | | | | | 3. RELOCATION OF AHU 2 WILL ALSO REQUIRE THE RELOCATION | | | OR NEW INSTALLATION OF A DUCT SMOKE DETECTOR IN | | | ACCORDANCE WITH FBC, M 606.2.1. THIS DETECTOR SHALL BE | | | CONNECTED TO THE BUILDING FIRE ALARM SYSTEM IN | | | ACCORDANCE WITH FBC, M 606.4.1. SHOW COMPLIANCE WITH | | | THESE SECTIONS. | | | | | | 4. PG M1: MANY OF THE NOTES WHICH INDICATE THE SCOPE OF | | | WORK RELATED TO RELOCATION OF AHU 2 ARE CURRENTLY PART | | | OF THE SCOPE OF WORK WITHIN A SEPARATE PERMIT | | | APPLICATION WITH DIFFERENT CONTRACTORS AND DIFFERENT | | | DESIGNERS. PERMIT #07080934 IS FOR THE PURPOSE OF | | | ADDING A FIRE RATED TENANT SEPARATION WALL TO SPLIT THE | | | RETAIL SPACE FROM THE RESTAURANT. PLEASE VERIFY THAT | | | THE SCOPE OF WORK RELATED TO ONE PERMIT IS NOT IN | | | CONFLICT OR BEING DUPLICATED ON THE OTHER. FBC 106.1.1 | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-29 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-29 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2008-02-29 14:28:26 | SEPARATE GAS PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-22 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-22 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2008-02-22 18:13:50 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | A. ALL SHEETS. THE TITLE BLOCK OF THE ARCHITECT FIRM | | | SHALL INCLUDE THE FIRM LICENSE NUMBER. FAC | | | 61G1-16.004(2) & FS 481.219, 481.2055. | | | ****NO RESPONSE, BUT NOT SHOWN IN THE TITLE BLOCKS FOR | | | THE M-E-P SHEETS. | | | | | | B. ROUTE THE PLANS TO THE DEPT. OF BUSINESS REGULATION, | | | HOTEL & RESTAURANT DIVISION FOR REVIEW. EACH SET OF | | | PLANS SHALL HAVE A STAMPED/REVIEWED SHEET SUBMITTED | | | WITH THE TWO PAGE "SPECIFICATION WORKSHEETS" ATTACHED | | | TO THE SHEET STAMPED BY DBPR PRIOR TO RESUBMITTING. | | | SECTION 102.2.1. | | | ****NO RESPONSE, THE SPECIFICATION WORKSHEETS HAVE NOT | | | BEEN ATTACHED TO THE SHEET STAMPED BY DBPR. | | | | | | C. A SEPARATE GAS PERMIT IS REQUIRED. THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE PERMIT. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. FOR ALL EXISTING PIPE. | | | ****RESPONSE NOTED, BUT THE LENGTH OF PIPE FROM THE | | | MAIN GAS LINE TO THE DROP IS NOT INDICATED ON THE | | | RISER. ALL PIPING DOWNSTREAM OF RANGE/OVEN (30) SHALL | | | BE DELETED, OR THE DEVELOPED LENGTH WILL BE INDICATED | | | TO THE MOST REMOTE APPLIANCE AND THE PIPE SIZE AND ALL | | | LENGTHS OF SECTIONS AS WELL AS MAXIMUM BTU LOAD WILL BE | | | INDICATED FOR THE TWO PLUGED APPLIANCES. MANY PIPE | | | SIZES ARE INCORRECT FOR THE DROPS AND 2-1/2" IS | | | REQUIRED UP TO THE DROP PICKING UP THE FRYERS (27). | | | (THIS HAS BEEN SIZED USING A MAXIMUM 100 FEET TOTAL | | | DEVELOPED LENGTH. IF THE TOTAL DEVELOPED LENGTH IS | | | INDICATED AS MORE THEN THE PIPING WILL BE SIZED BY THE | | | NEXT LINE UP IN THE TABLE WHICH IS 125 FEET.) TABLE | | | 402.4(2).--MORE INFORMATION IS REQUIRED. IS ALL THE | | | GAS PIPING TO BE RUN BELOW THE CEILING? OR IS THERE NO | | | CEILING IN THE PREP KITCHEN? PLEASE CLARIFY. SECTION | | | 106.1.2. | | | | | | 2. OK | | | | | | 3. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | ****RESPONSE NOTED, INFORMATION TO BE VERIFIED ONCE | | | COMMENT 1. INFORMATION RECIEVED | | | | | | 4. OK | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ****RESPONSE NOTED, BUT NO MANUF. SHEETS WERE | | | SUBMITTED. | | | | | | 6. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | ****RESPONSE NOTED, BUT PLEASE VERIFY IF THERE IS A | | | CEILING IN THE PREP KITCHEN. | | | | | | **********NEW COMMENT********** | | | | | | 1B. SHT P1 NOTE STATES "SYSTEM SIZED BY FBC 2004 FUEL | | | GAS CODE TABLE A.3.1(4)",WHICH IS IN CONFLICT WITH | | | THE NOTE THAT STATES "GAS PIPING SIZED AS PER FBC-2004 | | | FUEL GAS TABLE 402.4(2)". PLEASE DELETE NOTE | | | REFERENCING TABLE A.3.1.4(4) AS THERE IS NO TABLE | | | A.3.1.4(4) IN THE FBC-2004 FUEL GAS CODE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-14 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-14 |
Time |
18:40 |
Sent To |
|
|
| Notes |
| 2007-12-14 18:50:45 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A. ALL SHEETS. THE TITLE BLOCK OF THE ARCHITECT FIRM | | | SHALL INCLUDE THE FIRM LICENSE NUMBER. FAC | | | 61G1-16.004(2) & FS 481.219, 481.2055. | | | | | | B. ROUTE THE PLANS TO THE DEPT. OF BUSINESS REGULATION, | | | HOTEL & RESTAURANT DIVISION FOR REVIEW. EACH SET OF | | | PLANS SHALL HAVE A STAMPED/REVIEWED SHEET SUBMITTED | | | WITH THE TWO PAGE "SPECIFICATION WORKSHEETS" ATTACHED | | | TO THE SHEET STAMPED BY DBPR PRIOR TO RESUBMITTING. | | | SECTION 102.2.1. | | | | | | C. A SEPARATE GAS PERMIT IS REQUIRED. THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE PERMIT. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. FOR ALL EXISTING PIPE. | | | | | | 2. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 3. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 4. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | 6. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-02-07 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-02-07 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-02-07 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2008-02-07 13:28:48 | ZONING REVIEW: PASSED | | | | | | MATT FLIS - 8221445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-14 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-12-14 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-12-14 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2007-12-14 13:39:43 | ZONING REVIEW: FAILED | | | | | | * PLANS INDICATE NEW RAILING AT STREET SIDE / EXTERIOR | | | TO BUILDING; PLEASE PROVIDE NOTE AND/OR DETAIL | | | INDICATING MATERIAL, HEIGHT, AND DESIGN OF RAILING. IS | | | THIS TO MATCH EXISTING? WILL THIS MEET FBC GUARDRAIL | | | REQ'S? | | | | | | MATT FLIS - 822-1445 |
|
|