Plan Review Details - Permit 07110567
Plan Review Stops For Permit 07110567
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-01-02 Cont ID  
Sent By mjacobs Date 2008-01-02 Time 14:27 Rev Time 0.00
Received By mjacobs Date 2008-01-02 Time 12:43 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-12-01 Cont ID  
Sent By mjacobs Date 2007-12-01 Time 09:45 Rev Time 0.00
Received By mjacobs Date 2007-12-01 Time 06:25 Sent To  
Notes
2007-12-01 09:45:49 
 BUILDING PLAN REVIEW
 PERMIT: 07110567
 ADD: 5600 N. FLAGLER DR. #2409
 CONT: COLBURN CONST. INC.
 TEL: (561)805-7165
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
 12/1/07
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 1B) PLEASE SUBMIT 2 COPIES OF ALL, PLANS, REPORTS,
 PRODUCT APPROVALS FOR REVIEW FOR PERMIT.
 106.1* /2004 SUBMITTAL DOCUMENTS WEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
  
  
  
 2)2004 FBC EXISTING
 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE. THIS PROJECT
 APPEARS TO BE A LEVEL 2.
  
 3)THE CLAIMED VALUATION OF BUILDING, ALTERATION,
 STRUCTURE, ELECTRICAL, MECHANICAL OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION.
 VALUATION SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, ARCHITECTURAL AND DESIGN FEES EXCLUDING LAND.
 OUR VALUATION REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER 108.3 FBC*
  
 4) 106.3.3* PRODUCT APPROVALS- THOSE PRODUCTS THAT ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL. PROVIDE THE
 PRODUCT APPROVALS FOR THE SLIDING GLASS DOORS AND THE
 GLASS BLOCK. PROVIDE BUILDING HEIGHT ON THE PLAN.
 DESIGN PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED
 TO BE DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE
 DONE BY AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002. THIS REFERS TO THE SLIDING
 GLASS DOORS.
  
 5)FBC 907.2.10.1.2 SINGLE OR MULTIPLE-STATION SMOKE
 ALARMS SHALL BE INSTALLED INSIDE AND OUTSIDE EACH ROOM
 USED FOR SLEEPING PURPOSES. SEE R313 FBC RESIDENTIAL.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-12-28 Cont ID  
Sent By btrobaug Date 2007-12-28 Time 15:51 Rev Time 0.00
Received By btrobaug Date 2007-12-28 Time 15:43 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-12-04 Cont ID  
Sent By btrobaug Date 2007-12-04 Time 15:02 Rev Time 0.00
Received By btrobaug Date 2007-12-04 Time 14:06 Sent To P
Notes
2007-12-04 15:02:12 
  
 APPLICATION #07110567
 ELECTRICAL PLAN REVIEW
 5600 N. FLAGLER DRIVE
 12/4/07
 WEST PALM BEACH, FL.
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
 ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE
 NOTED.
  
 1} 408.30 GENERAL. ALL PANELBOARDS SHALL HAVE A RATING
 NOT LESS THAN THE MINIMUM FEEDER CAPACITY REQUIRED FOR
 THE LOAD CALCULATED IN ACCORDANCE WITH ARTICLE 220. THE
 130 AMP LOAD CALCULATED ON THE PANEL EXCEEDS THE 125
 AMP PANEL RATING.
  
 2} THE INSTA HOT SHOWN ON THE PLAN IS NOT ON THE PANEL
 SCHEDULE OR IN THE LOAD CALCULATION. 220.12, 220.14,
 220.83. (SEE THESE ARTICLES FOR THE CORRECT
 CALCULATION. 220.30 IS AN ARTICLE FROM 2004 CODE,
 REMOVE FROM PLAN).
  
 3} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), AND BE GFI PROTECTED PER 210.8(A)
 (1). THIS CIRCUIT IS NOT ON THE PANEL SCHEDULE.
  
 4} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. THE ?BAR? IS
 A PENINSULAR FOR THE KITCHEN WHOSE COUNTERTOP
 RECEPTACLES MUST COMPLY WITH 210.8(A)(6) AS WELL.
 GFCI.
  
 5} THE COUNTERTOP BEING INSTALLED MUST ALLOW 3?
 CLEARANCE FROM THE EXISTING PANEL PER 110.26.
  
 6} PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE
 BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE
 CIRCUIT THAT MAY ENERGIZE THE FRAMING. SEE ARTICLE.
 PLEASE PUT A NOTE ON THE PLAN FOR CLARITY IN THE
 FIELD.
  
 THE TITLE BLOCK CONTAINS THE ADDRESS OF THE PROJECT
 REQUIRED BY 106.3.1 FBC, BUT INCLUDES THE WORD
 ?ADDITION?. AS THIS DOES NOT APPEAR TO BE AN ADDITION,
 CLARIFY. 301.5 FBC EXISTING BUILDING CODE. THE DESIGN
 PROFESSIONAL OR OWNER MUST ELECT THE LEVEL OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF THE
 EXISTING BUILDING CODE. PLEASE DECLARE SAME ON THE
 PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-12-11 Cont ID  
Sent By mawillia Date 2007-12-11 Time 18:27 Rev Time 0.00
Received By mawillia Date 2007-12-11 Time 17:57 Sent To  
Notes
2007-12-11 18:29:09*****PROVISO*****
  
  
 THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN
 ALL OTHER REVIEWERS HAVE BEEN SATISFIED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-29 Cont ID  
Sent By adarroug Date 2007-11-29 Time 12:51 Rev Time 0.00
Received By adarroug Date 2007-11-29 Time 12:51 Sent To  
Notes
2007-11-29 12:52:02TO "BOB"#2--PER RBROWN

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-12-11 Cont ID  
Sent By mawillia Date 2007-12-11 Time 17:58 Rev Time 0.00
Received By mawillia Date 2007-11-21 Time 16:02 Sent To  
Notes
2007-11-29 12:12:5011/29/07WILL BE ROUTED TO BOB BOARD.
 **SAME PROJECT WAS ORIGINALLY REVIEWED**
 **UNDER PERMIT # 07100050. THAT PERMIT**
 **WAS VOIDED BY G.C. THIS IS NEW G.C. RB**
2007-11-21 16:02:57TO SMH DESK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-12-03 Cont ID  
Sent By tgordon Date 2007-12-03 Time 10:59 Rev Time 0.20
Received By tgordon Date 2007-12-03 Time 10:59 Sent To  
Notes
2007-12-03 10:59:59NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-01-02 Cont ID  
Sent By mperson Date 2008-01-02 Time 08:49 Rev Time 0.00
Received By mperson Date 2008-01-02 Time 08:49 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-12-07 Cont ID  
Sent By mperson Date 2007-12-07 Time 07:19 Rev Time 0.00
Received By mperson Date 2007-12-07 Time 07:19 Sent To  
Notes
2007-12-07 07:59:33PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1 NEW FLOOR PLAN: PLEASE CORRELAT THE
 KITCHEN WITH THE EXISTING FLOOR/DEMO PLAN BY INDICATING
 WHICH FIXTURES ARE TO BE REPLACED NEW ON THE
 RESUBMITTAL. PER *106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS AND *106.1.2 ADDITIONAL DATA.
  
 2. SHEET A-1 AND E-1: PLEASE CLARIFY IF THE NEW INSTA
 HOT IS GAS OR ELECTRIC AND SUBMIT TWO COPIES OF
 MANUFACTURER'S SPECIFICATION SHEETS INDICATING THE
 MAKE, MODEL NUMBER, AND A LISTING FROM A NATIONALLY
 RECOGNIZED TESTING LABORATORY (NRTL). PER *106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS AND 106.1.2
 ADDITIONAL DATA.
  
 3. SHEET A-1 AND E-1 TITLE BLOCKS: THE TITLE BLOCKS
 ARE INDICATING "ADDITION FOR". THE PROPOSED WORK DOES
 NOT APPEAR TO BE AN ADDITION. PLEASE CLARIFY THIS PER
 FBC-2004, EXISTING BUILDING, SECTION *301.5.
  
 4. NOTE: PLEASE REFERENCE BUILDING PLAN REVIEW COMMENT
 #3 ON VALUE BEING LOW. PER *108.3 BUILDING PERMT
 VALUATION.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2007-12-04 Cont ID  
Sent By choops Date 2007-12-04 Time 09:25 Rev Time 0.00
Received By choops Date 2007-12-04 Time 09:25 Sent To  
Notes
2007-12-04 09:25:22*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.