| Plan Review Stops For Permit 07110531 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-01-15 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-01-15 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-12-01 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-12-01 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2007-12-01 15:54:50 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07110531 | | | ADD: 8989 OKEECHOBEE BLVD | | | CONT: COHEN INC. | | | TEL: (561)362-4271 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST 12/1/07 | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 REVISIONS. | | | | | | 2)2004 FBC EXISTING301.5 A DESIGN PROFESSIONAL OR AN | | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | | THIS CODE. | | | | | | 3)FBC 11-7.2(2)(I)A PORTION OF THE MAIN COUNTER | | | SHALL BE A MINIMUM OF 36 INCHES IN LENGTH AND A MAXIMUM | | | OF 36 INCHES HIGH. | | | | | | 4)THE BREAK ROOM SINK SHALL MEET THE REQUIREMENTS OF | | | FBC 11-4.24. SHOW THE KNEE CLEARANCE WILL BE ACHIEVED. | | | THE CABINET DOORS IN FRONT OF THE SINK CANNOT HINDER | | | THE REQUIREMENTS OF THIS SECTION. SUBMIT AN ELEVATION | | | DETAIL DRAWING MEETING ALL DIMENSIONS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-24 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-22 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-22 |
Time |
13:43 |
Sent To |
PC |
|
| Notes |
| 2008-01-22 14:15:19 | | | | | | | | | | | | | PROVISO | | | | | | THIS SHEET MUST BE REVISED TO SHOE THE AUTOMATIC SPACE | | | CONTROLS REQUIRED BY 13-415.1.ABC.1.2 FBC, PRIOR TO | | | FIRST ELECTRICAL INSPECTION. THE REVISED SHEET STAMPED | | | BY THIS OFFICE MUST BE ON SITE. ALLOW AT LEAST A WEEK | | | FOR THE REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-29 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-29 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2007-11-29 09:21:24 | | | | | | | | | | APPLICATION #07110531 | | | ELECTRICAL PLAN REVIEW | | | 8989 OKEECHOBEE BLVD | | | 11/29/07 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | | | | 13-400.0.C.4 RENOVATED BUILDINGS. | | | RENOVATED BUILDINGS SHALL, WHEN APPLICABLE (SEE SECTION | | | 202), MEET THE EFFICIENCIES LISTED ON FORM 400C FOR | | | COMPONENTS BEING CHANGED OR SHALL COMPLY WITH THE | | | ENVELOPE OR SYSTEMS CRITERIA IN METHOD B OF FLA/COM FOR | | | THE COMPONENTS BEING CHANGED. EXISTING BUILDINGS NOT | | | MEETING THE DEFINITION OF A RENOVATION IN WHICH NEW | | | HEATING, COOLING, WATER HEATING, ELECTRICAL OR LIGHTING | | | SYSTEMS ARE INSTALLED SHALL MEET THE BASIC PRESCRIPTIVE | | | MINIMUM EFFICIENCIES LISTED IN THIS CODE FOR THE | | | SYSTEM(S) BEING CHANGED. SUBMIT DENSITY CALCULATIONS. | | | THE FIXTURE SCHEDULE MUST REFLECT THE TYPE AND COUNT | | | USED FOR COMPLIANCE. | | | | | | 13-415.1.ABC.1.2 SPACE CONTROL. | | | EACH SPACE ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL | | | HAVE AT LEAST ONE CONTROL DEVICE TO INDEPENDENTLY | | | CONTROL THE GENERAL LIGHTING WITHIN THE SPACE. EACH | | | MANUAL DEVICE SHALL BE READILY ACCESSIBLE AND LOCATED | | | SO THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING. | | | INDICATE COMPLIANCE ON THE PLAN. SEE SUBCHAPTER FOR | | | MORE INFORMATION REGARDING REQUIREMENTS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-01-16 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-16 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-12-12 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-12-12 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2007-12-12 12:44:53 | ***DENIED*** | | | | | | 1) MERCANTILE OCCUPANCY IS REFERENCED FOR INTERIOR WALL | | | AND CEILING FINISHES, AND THE OCCUPANT LOAD IS BASED ON | | | BUSINESS. PLEASE CORRELATE ALL INFORMATION USING THE | | | CORRECT OCCUPANCY CLASSIFICATION FOR THIS SPACE. | | | | | | 2) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION. | | | | | | 3) THE BREAKROOM EXIT DOOR SHALL NOT BE OBSTRUCTED BY | | | TYPICAL BREAKROOM FURNITURE. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS ARE REQUIRED FOR | | | FIRE SPRINKLER AND FIRE ALARM REMODEL IF APPLICABLE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-10 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2008-01-10 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2008-01-10 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2008-01-10 09:21:59 | TO "BOB" # 17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-12-12 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-11-26 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2007-11-28 11:49:53 | TO "BOB"#7 | | 2007-11-26 15:18:34 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-03 |
Time |
10:52 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-12-03 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-14 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-14 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-11 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-11 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2007-12-11 08:45:25 | DENIED; | | | 1. PAGE A-6.0 BREAK SINK DETAIL. NO CABINET DOORS | | | PERMITED. SEE FBC BUILDING CHAPTER 11 SECTION 11-4.24.3 | | | KNEE CLEARANCE UNDER SINK.SHOW ON DETAIL ALL | | | MEASUREMENTS REQUIRE TO COMPLY WITH SECTIONS 11-4.24.1 | | | THRU 11-4.24.7. | | | 2. DRINKING FOUNTAIN ON FLOOR PLAN PAGE A-1.1. | | | 3. WATER HEATER ON WATER RISER DIAGRAM SHOW THE | | | TERMINATION POINTS FOR RELIEF LINE AND PAN DRAIN. SEE | | | FBC-PLUMBING SECTIONS 504.6 AND 504.7.2. | | | 4. SHOW THERMAL EXPANTION CONTROL TO BE USED , SEE | | | SECTION 607.3. SHOW ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-28 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-28 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2007-11-28 15:10:27 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|