Plan Review Details - Permit 07110480
| Plan Review Stops For Permit 07110480 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-14 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-14 |
Time |
08:20 |
Sent To |
PC |
|
| Notes |
| 2008-07-14 08:25:18 | REVISION: "OK" NEW LONGEST LENGTH OF 300'. (SEE RED | | | LINE CHANGES TO CSST IN ATTIC) | | | | | | ****************PROVISO**************** | | | IF WATER HEATER ROOM IS A CONFINED | | | SPACE, OPENINGS REQUIRED PER SECTION | | | 304.5 OR SECTION 304.6 SHALL BE | | | INSTALLED. | | | MINIMUM 3,750 CUBIC FEET REQUIRED. | | | | | | FUTURE GENERATOR GAS PIPING AT OWN RISK, SEPERATE | | | GEN/RES PERMIT REQUIRED WITH ZONING APPROVAL OF | | | GENERATOR PLACEMENT. | | | NOTE: PER FBC-2004 FUEL GAS SECTION, 404.12 OUTLET | | | CLOSURES. GAS OUTLETS THAT DO NOT CONNECT TO APPLIANCES | | | SHALL BE CAPPED GAS TIGHT. IF GAS DELIVERY PRESSURE IS | | | 2 PSI OR GREATER MP REGULATORS SHALL BE INSTALLED PRIOR | | | TO FINAL INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-05 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-05 |
Time |
08:51 |
Sent To |
PC |
|
| Notes |
| 2007-12-05 09:03:39 | ****************PROVISO**************** | | | IF WATER HEATER ROOM IS A CONFINED | | | SPACE, OPENINGS REQUIRED PER SECTION | | | 304.5 OR SECTION 304.6 SHALL BE | | | INSTALLED. | | | MINIMUM 3,750 CUBIC FEET REQUIRED. | | | | | | FUTURE GENERATOR GAS PIPING AT OWN RISK, SEPERATE | | | GEN/RES PERMIT REQUIRED WITH ZONING APPROVAL OF | | | GENERATOR PLACEMENT. | | | NOTE: PER FBC-2004 FUEL GAS SECTION, 404.12 OUTLET | | | CLOSURES. GAS OUTLETS THAT DO NOT CONNECT TO APPLIANCES | | | SHALL BE CAPPED GAS TIGHT. IF GAS DELIVERY PRESSURE IS | | | 2 PSI OR GREATER MP REGULATORS SHALL BE INSTALLED PRIOR | | | TO FINAL INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-10 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-10 |
Time |
15:17 |
Sent To |
G |
|
| Notes |
| 2008-07-10 15:18:06 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-05 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-11-19 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2007-11-19 13:44:32 | TO "G" BOX |
|
|
|