| Plan Review Stops For Permit 07110460 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-11 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-11 |
Time |
16:13 |
Sent To |
PC |
|
| Notes |
| 2008-06-11 16:15:24 | REMAINDER:COMPLY WITH PROVISO DATED 2-12-08 TO AVOID | | | DELAYS IN CERTIFICATE OF OCCUPANCY. SEE ATTACHED COPY | | | OF PROVISO. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-04-02 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-02 |
Time |
13:40 |
Sent To |
E |
|
| Notes |
| 2008-04-02 13:44:37 | BUILDING REVISION APPROVED. THE FOLLOWING ARE | | | INFORMATIONAL NOTES: | | | | | | 1-PLANS SENT TO ELECTRICAL BECAUSE REVISED ELECTRICAL | | | PLAN WAS SUBMITTED. | | | | | | 2- REMAINDER: PROVIDE INFORMATION REQUESTED ON PROVISO | | | DATED 02/12/08 TO AVOID DELAYS. SEE ATTACHED COPY. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-02-12 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-02-12 |
Time |
14:17 |
Sent To |
Z |
|
| Notes |
| 2008-02-12 14:24:07 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-SURVEY NEEDSTO HAVE ORIGINAL SIGNATURE, NOT | | | RUBBER STAMP, AS REQUIRED BYCHAPTER 472 FLORIDA | | | STATUTE AND SEC. 61G17-7.0025 FLORIDA ADMINISTRATIVE | | | CODE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-04 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-01-17 |
Time |
16:56 |
Sent To |
PC |
|
| Notes |
| 2008-01-17 17:01:14 | BUILDING REVIEW APPROVED WITH PROVISO. | | | | | | 1-ARCHITECT TO SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. 106.1.1.2OF CITY AMENDMENTS TO FBC | | | 2004. IFUSING NAILS OR SCREWS, THENSPECIFY SIZE AND | | | NUMBER. IF USING POLYFOAM, THEN PROVIDE PRODUCT | | | APPROVAL AS REQUIRED BY DCA RULE 9B-72.SEE TILE | | | PRODUCT APPROVAL FOR LISTED FOAM TO BE USED. | | | | | | ***NOTE:PROVIDE INFORMATION PRIOR TO INSTALLATION TO | | | AVOID CONFLICTS OR DELAYS. | | | | | | 2- SURVEY: | | | A) REVISE DIMENSIONS TO MATCH ARCHITECTURAL SITE | | | PLAN AND FOUNDATION PLAN. NO HAND WRITEN DIMENSIONS. | | | | | | B) NEED ORIGINAL SURVEYOR'S SIGNATURE AS REQUIRED BY | | | CHAPTER 472 AND FLORIDA ADMINISTRATIVE CODE SEC. | | | 61G17-7.0025. COPY OF SIGNATURE IS NOT ALLOWED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-10 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-12-10 |
Time |
12:59 |
Sent To |
PC |
|
| Notes |
| 2007-12-10 13:03:49 | RESIDENTIAL ADDITION BUILDING REVIEW CHECKLIST. REVIEW | | | DONE UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | | (561)233-5115) TO VERIFY IF IMPACT FEES ARE DUE. BRING | | | BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE | | | DUE. | | | | | | 2- SHEET T1.0: | | | A) SPECIFY ATTIC LIVE LOAD AS REQUIRED BY TABLE | | | R301.5 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | B) CODE TO BE REFERENCED IS FBC 2004 WITH 2007 | | | REVISIONS, NOT 2006. UPDATE AS REQUIRED. | | | | | | C) COMPONENTS & CLADDING DESIGN WIND PRESSURES DON'T | | | MATCH THE DESIGN PRESSURES SPECIFIED ON SHEET A3.0. | | | REVISE AS REQUIRED TO MATCH. | | | | | | D) CONSULTING ENGINEER "STRUCTURAL SYSTEMS, INC" TO | | | SIGN AND SEAL DRAWINGS AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTE AND SEC. 61G15-23.002(2) OF FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | E) REVISE MASONRY NOTE ON STRUCTURAL NOTES AND ON | | | CONCRETE UNIT MASONRY NOTE F.SEE SEC. R606.4 OF 2004 | | | FLORIDA RESIDENTIAL CODE REGARDING THE MINIMUM MASONRY | | | UNIT ALLOWABLE STRESS. | | | | | | F) UPDATE THERMAL MOISTURE PROTECTION NOTE A. SEE | | | CHAPTER 13 FBC 2004 FOR CORRECT REFERENCE TO BE USED. | | | | | | 3- PROVIDE SOIL TEST REPORT.SEC. R401.4 OF 2004 | | | FLORIDA RESIDENTIALCODE.TWO COPIES WITH ORIGINAL | | | SIGNATURE AND SEAL. AND, ENGINEERING FIRM CERTIFICATE | | | OF AUTHORIZATION NUMBER. SEC. 61G15-23.002(2) OF | | | FLORIDA ADMINISTRATIVE CODE. | | | | | | 4- DESIGNEROF RECORD TO SPECIFY ROOF TILE FASTENING. | | | SEESEC. 106.1.1.2 CITY AMENDMENTS TO FBC 2004. IF | | | USING POLYFOAM, THEN PROVIDE PRODUCT APPROVAL AS | | | REQUIRED BY DCA RULE 9B-72. | | | IN ADDITION, MAKE SURE THAT TILE ADHESIVE IS TESTED AND | | | APPROVED TO BE USED WITH GRACE ICE UNDERLAYMENT, WHICH | | | IS THE TYPE OF UNDERLAYMENT THAT WAS SUBMITTED WITH | | | THIS PACKAGE. PROVIDE TECHNICAL INFORMATION AS REQUIRED | | | TO SHOW COMPATIBILITY WITH THE PROPOSED INSTALLATION. | | | ON THE OTHER HAND, IF USING NAILS OR SCREWS, THEN | | | CLEARLY SPECIFY TYPE AND NUMBER TO VERIFY COMPLIANCE | | | WITH THE UPLIFT RESISTANCE SHOWN ON THE PRODUCT | | | APPROVAL. | | | | | | 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) FIXED WINDOW SIZE AS SHOWN ON PLANS. | | | | | | B) WINDOW MULLIONS. | | | | | | C) ALL SIMPSON OR USP CONNECTORS SPECIFIED ON PLANS. | | | PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER PAGE | | | AND PAGE WHERE CONNECTOR IS SHOWN. | | | | | | D) PRECAST LINTELS. | | | | | | E) GRACE ICE UNDERLAYMENT.INFORMATION SUBMITTED | | | NEED TO HAVE THE INSTALLATION SPECIFICATIONS. | | | COORDINATE INFORMATION WITH ITEM 4 ABOVE. | | | | | | F) SINGLE HUNG WINDOWS. PROVIDE INFORMATION THAT | | | MATCHES INFORMATION GIVEN ON FL #2769.3. IT SHOWS 7/16 | | | GLAZING. INFORMATION SUBMITTED DOESN'T MATCH. | | | | | | | | | 6- PROVIDE STRUCTURAL WINDOW BUCK DETAILUSING 2X BUCK | | | TO SHOW COMPLIANCE WITH PRODUCT APPROVAL SUBMITTED FOR | | | SINGLE HUNG WINDOWS.PRODUCT APPROVAL SUBMITTEDONLY | | | SHOWS ATTACHMENT TO 2X STRUCTURAL BUCK.SEC. 106.1.2 | | | CITY AMENDMENTS TO FBC 2004. | | | | | | 7- SHEET D1.0: REVISE TYPE OF NAIL TO BE USED IN ROOF | | | SHEATHING. SEE SEC. R803.2.3.1 OF 2004 FLORIDA | | | RESIDENTIAL CODE.REQUIRES 8D RING SHANK NAILS. | | | | | | 8- OWES $7.26 FOR RADON FEES. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-07 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-07 |
Time |
07:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-15 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-15 |
Time |
08:17 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-02-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-04 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-04 |
Time |
07:01 |
Sent To |
B |
|
| Notes |
| 2008-02-04 09:13:58 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} PROVIDE LOAD CALCULATIONS PER 220.83 INCLUDING | | | EXISTING AND ADDED LOADS.106.3.5.4(8) FBC AS AMENDED. | | | | | | 2} LOCATE THE NEW 125 AMP PANEL ON THE PLANS SO THAT | | | COMPLIANCE WITH 230.70, 225.32 MAY BE REVIEWED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-10 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-10 |
Time |
10:24 |
Sent To |
M |
|
| Notes |
| 2008-01-10 14:06:46 | | | | | | | | | | APPLICATION # 07110460 | | | ELECTRICAL PLAN REVIEW | | | 10301 HERONWOOD LANE | | | 1/10/08 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. SHEET E-1, UNLESS OTHERWISE NOTED. | | | | | | 1} THE RISER DIAGRAM INDICATES A 225 AMP MAIN BREAKER | | | AND 3/0 COPPER FEEDERS, WHICH ARE CORRECT FOR THAT | | | BREAKER PER 310.15(B)(6). THE LOAD CALCULATIONS ARE | | | SHOWN AS 246 AMPS, AND ALTHOUGH THE NOTE AT THE BOTTOM | | | OF THE CALCULATION INDICATES A 300 AMP SERVICE, THAT | | | DOES NOT CORRELATE WITH THE RISER. SERVICE-LATERAL | | | CONDUCTORS SHALL HAVE SUFFICIENT AMPACITY TO CARRY THE | | | CURRENT FOR THE LOAD AS CALCULATED IN ACCORDANCE WITH | | | ARTICLE 220 AND SHALL HAVE ADEQUATE MECHANICAL | | | STRENGTH. THE SERVICE SIZE MUST BE INCREASED TO SERVE | | | THE LOAD, OR BE RECALCULATED TO INDICATE THE DEMAND IS | | | LESS THAN 225 AMPS. SEE 220.83. | | | | | | 2} THE 6/0 FEEDERS INDICATED ON THE RISER DO NOT | | | CORRELATE WITH AWG SIZES IN THE NEC. | | | | | | 3} THE DISCONNECT FOR THE A/C UNIT DOES NOT COMPLY WITH | | | 110.26 CLEARANCE REQUIREMENTS. * THIS COMMENT IS MADE | | | AGAIN BECAUSE OF THE "CONCRETE EQUIPMENT PAD"IN FRONT | | | OF THE DISCONNECT. SEE 110.26. | | | | | | NOTE: ITEMS 2 AND 3 COULD HAVE BEEN REDLINED AND FIELD | | | CORRECTED WITH A REVISION. THE LOAD CALCULATION AND | | | SERVICE SIZE CANNOT BE REDLINED, SO ITEMS 2 AND 3 | | | SHOULD BE CORRECTED AT THIS TIME TO SAVE REVISION | | | FEES. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-20 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-20 |
Time |
13:31 |
Sent To |
M |
|
| Notes |
| 2007-11-20 14:12:04 | | | | | | | APPLICATION #07110460 | | | ELECTRICAL PLAN REVIEW | | | 10301 HERONWOOD LANE | | | 11/20/07 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | ALL COMMENTS RELATE TO SHEET E1.0, UNLESS OTHERWISE | | | NOTED. | | | | | | 1} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III, | | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. | | | THIS IS TO VERIFY THE TOTAL LOAD IS IN COMPLIANCE WITH | | | 220.83, TOTAL LOAD DOES NOT EXCEED THE SERVICE RATING. | | | | | | 2} THE RISER DIAGRAM FEEDERS AND PANEL RATING ARE NOT | | | CONSISTENT WITH THE PLANS. THE PLAN INDICATES A 60 AMP | | | PANEL, THE RISER A 50 AMP. THE 6/0 FEEDERS INDICATED ON | | | THE RISER DO NOT CORRELATE WITH AWG SIZES IN THE NEC. | | | | | | 3} CIRCUIT #9 ON THE PANEL SCHEDULE INDICATES EXTERIOR | | | RECEPTACLES ON THE SAME CIRCUIT WITH THE BATH IN | | | VIOLATION OF 210.11(C)(3). | | | | | | 4} THE DISCONNECT FOR THE A/C UNIT DOES NOT COMPLY WITH | | | 110.26 CLEARANCE REQUIREMENTS. INDICATE IF THIS IS A | | | NEW OR RELOCATED SYSTEM. | | | | | | PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH | | | CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM | | | SEPARATELY TO EXPEDITE THE REVIEW PROCESS. RESPOND TO | | | REVIEW COMMENTS IN WRITING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-09 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-09 |
Time |
10:56 |
Sent To |
Z |
|
| Notes |
| 2008-06-09 10:56:49 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-29 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-29 |
Time |
11:10 |
Sent To |
M |
|
| Notes |
| 2008-04-29 11:12:40 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-26 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-26 |
Time |
16:12 |
Sent To |
Z |
|
| Notes |
| 2008-03-26 16:12:45 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-01 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-01 |
Time |
15:34 |
Sent To |
E |
|
| Notes |
| 2008-02-01 15:35:18 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-08 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-08 |
Time |
16:42 |
Sent To |
Z |
|
| Notes |
| 2008-01-08 16:43:39 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-10 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-11-19 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2007-11-19 10:26:42 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-30 |
Time |
08:44 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-30 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2008-04-30 08:44:59 | REVISION TO MECH. PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-01-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-11 |
Time |
09:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-01-11 |
Time |
09:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-28 |
Time |
15:20 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-11-28 |
Time |
15:19 |
Sent To |
P |
|
| Notes |
| 2007-11-28 15:25:17 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) MECHANICAL PERMIT #07110463 HAS BEEN APPLIED FOR AND | | | AN A/C SYSTEM IS BEING INSTALLED, BUT NO MECHANICAL | | | PLANS WERE SUBMITTED FOR REVIEW. PLEASE SUBMIT | | | MECHANICAL PLANS FOR REVIEW, PER 2004 FBC CITY OF WPB | | | AMEND. 106.3.5.4 (10). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-16 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-16 |
Time |
08:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-04 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-04 |
Time |
07:26 |
Sent To |
B |
|
| Notes |
| 2007-12-04 07:37:33 | DENIED; | | | ADD NOTE TO PAGE A-2, " REMOVE ALL PIPING FROM 1/2 BATH | | | BACK TO THE BUILDING DRAIN. NO DEAD ENDS PERMITED. | | | INSPECTION REQUIRED". SEE FBC PLUMBING SECTION 704.5. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2008-06-10 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-10 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-10 |
Time |
14:46 |
Sent To |
B |
|
| Notes |
| 2008-06-10 14:46:40 | ***APPROVED - REVISION - ADDING PRIVACY WALL AROUND A/C | | | UNIT, STEEL DETAILS FOR RACK BEAM CHANGE | | | (STRUCTURAL)*** | | | | | | | | | | | | | | | | | | SENT TO "B" - JG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2008-03-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-28 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-28 |
Time |
12:01 |
Sent To |
B |
|
| Notes |
| 2008-03-28 12:04:07 | ***FAILED - REVISION - ADDING PRIVACY WALL AROUND A/C | | | UNIT, STEEL DETAILS FOR RACK BEAM CHANGE | | | (STRUCTURAL)*** | | | | | | | | | 1)PRIVACY WALL DETAIL (SHEET A1.0) SHOWS PRIVACY | | | WALL TO BE 6 FEET IN HEIGHT, ALL OTHER PLANS SHOW | | | PROPOSED PRIVACY WALL AT 5 FEET IN HEIGHT.PLEASE | | | CLARIFY. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | | | | SENT TO "B" - JG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-12 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-12 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2008-02-12 15:17:03 | ***APPROVED - RESUB #2*** | | | | | | RESTAMPED PLANS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-09 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-09 |
Time |
11:32 |
Sent To |
E |
|
| Notes |
| 2008-01-09 11:32:30 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-19 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-19 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
| 2007-11-19 13:31:51 | ***FAILED*** | | | | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY. | | | | | | 2)INDICATE SETBACK DIMENSIONS FROM THE PROPOSED A/C | | | EQUIPMENT TO THE PROPERTY LINES.PURSUANT TO SECTION | | | 94-305(B)(4) OF THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS):MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN 4' INTO A REQUIRED | | | SETBACK. | | | | | | NOTE:ADDITION MUST MAINTAIN INTERIOR ACCESS WITH | | | EXISTING STRUCTURE. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|