Plan Review Details - Permit 07110377
| Plan Review Stops For Permit 07110377 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-13 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-13 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2007-12-13 16:32:42 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.ADDRESSED. | | | | | | 2.SEE SHEET 10.-75PSF REQUIRES 12" SPACING, | | | INSTALLATION SCHEDULE SPECIFIES 13.5". | | | | | | ANCHOR SPACING NOT COMPLIANT FOR DESIGN PRESSURES | | | SPECIFIED. | | | | | | 3.SHUTTER CONNECTION MOUNTING TYPE STATES TAPCON, | | | SHOULD CORRELATE WITH ANCHOR SCHEDULES, SECTIONS 1 | | | THROUGH 13, OR ALTERNATIVE SECTIONS 1 THROUGH 14. | | | | | | 4.WHAT IS THE SUBSTRATE?THE INSTALLATION SCHEDULE | | | STATES "WOOD - CBS".DOES THIS MEAN THAT IT IS CBS ON | | | THE BOTTOM, WOOD ON THE TOP? | | | | | | 5.AN EDGE DISTANCE OF LESS THAN 3 1/2" FOR CBS | | | REQUIRES USE OF A FACTOR, SEE SHEET 16. | | | | | | EDGE DISTANCE OF 1/2" AND 1 1/4" NOT ALLOWED.PLEASE | | | SEE PRODUCT APPROVAL, SHEET 10, AND REVISE INSTALLATION | | | SCHEDULE. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2007-11-14 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2007-11-19 16:28:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.TWO COMPLETE COLLATED SETS REQUIRED FOR PERMIT | | | ISSUANCE. | | | | | | 2.SEE SHEET 10.-75PSF REQUIRES 12" SPACING, | | | INSTALLATION SCHEDULE SPECIFIES 13.5". | | | | | | 3.SHUTTER CONNECTION MOUNTING TYPE STATES TAPCON, | | | SHOULD CORRELATE WITH ANCHOR SCHEDULES, SECTIONS 1 | | | THROUGH 13, OR ALTERNATIVE SECTIONS 1 THROUGH 14. | | | | | | 4.WHAT IS THE SUBSTRATE?THE INSTALLATION SCHEDULE | | | STATES "WOOD - CBS".DOES THIS MEAN THAT IT IS CBS ON | | | THE BOTTOM, WOOD ON THE TOP? | | | | | | 5.AN EDGE DISTANCE OF LESS THAN 3 1/2" FOR CBS | | | REQUIRES USE OF A FACTOR, SEE SHEET 16. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-07 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-07 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
| 2007-12-07 14:01:14 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-19 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-15 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2007-11-15 10:38:11 | TO "MISC" BOX#1 |
|
|
|