Plan Review Details - Permit 07110328
| Plan Review Stops For Permit 07110328 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-10 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-12-10 |
Time |
07:37 |
Sent To |
PC |
|
| Notes |
| 2007-12-10 08:00:17 | RESIDENTIAL ALTERATION BUILDING REVIEW CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- PROVIDE CLEAR DRAWINGS DRAWN TO SCALE AND SHOWING | | | ALL SCOPE OF WORK IN DETAIL, INCLUDING DIMENSIONS AS | | | REQUIRED BY SEC. 106.1.1 AND SEC. 106.1.3 OF CITY | | | AMENDMENTS TO FBC 2004. PERSON RESPONSIBLE FOR THE | | | DESIGN SHALL PROVIDE HIS/HERNAME AND SIGN DRAWINGS. | | | | | | 2- PROVIDE COMPLETEFRAMING DETAILS FORNEW FRENCH | | | DOORS AS REQUIRED BY SEC. R301.1 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 3- PROVIDE NOTICE OF COMMENCEMENT AS REQUIRED BY SEC. | | | 713.13 FLORIDA STATUTE. | | | | | | 4- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | | (561)233-5115)TO VERIFY IF IMPACT FEES ARE DUE WHEN | | | CHANGINGUSE FROM GARAGE TO LIVING AREA. BRING BACK | | | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE | | | DUE. | | | | | | 5- VALUATION STATEDIN THE PERMIT APPLICATION IS TOO | | | LOW.UPDATE VALUATION TO INCLUDE ALL MATERIALS AND | | | LABOR. OTHERWISE VALUATION WILL BE UPGRADED AS REQUIRED | | | BY SEC. 108.3 OF CITY AMENDMENTS TO FBC 2004. | | | | | | 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72 | | | FOR: | | | A) NEW FRENCH DOORS. | | | | | | B) ALL SIMPSON OR USP STRUCTURAL CONNECTORS | | | SPECIFIED ON NEW DOOR FRAMING DETAILS. | | | | | | C) STORM SHUTTERS IF FRENCH DOORS DON'T HAVE IMPACT | | | WINDOWS. AND PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | SEE ATTACHED SAMPLE. AND, CLEARLY IDENTIFY | | | INSTALLATION TYPE (EG: WALL MOUNTED, ETC.) AND SPECIFIC | | | ANCHOR TYPE AND SPACING TO BE USED. | | | | | | 7- PROVIDE SPECIFICATIONS IN PLANS SHOWINGTYPE OF | | | WOOD TO BE USED IN ORDER TO COMPLY WITH SEC. R319.1(5) | | | OF 2004 FLORIDA RESIDENTIAL CODE TO PROVIDE PROTECTION | | | AGAINST WOOD DECAY. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-20 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-20 |
Time |
13:13 |
Sent To |
P |
|
| Notes |
| 2007-11-20 13:27:05 | | | | | | | APPLICATION #07110328 | | | ELECTRICAL PLAN REVIEW | | | 920 ALMERIA RD. | | | 11/20/07 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | | | 2} A GROUNDING ELECTRODE CONDUCTOR IS REQUIRED AT THE | | | SEPARATE STRUCTURE PER 250.32, SIZED PER 250.66. | | | PROVIDE A RISER DIAGRAM OF THE SERVICE EQUIPMENT. | | | 215.5. | | | | | | 3} PLEASE PROVIDE A PANEL SCHEDULE SO THAT | | | BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT | | | PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC | | | AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-10 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-11-14 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2007-11-14 12:57:20 | TO "SFR" "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-04 |
Time |
09:03 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-12-04 |
Time |
09:03 |
Sent To |
Z |
|
| Notes |
| 2007-12-04 09:11:00 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLANS MAY NOT BE DONE IN PENCIL OR PEN, PLEASE MAKE | | | COPIES AND SUBMIT THE COPIES. SEE 2004 WPB AMEND. | | | 106.1.3. | | | | | | 2) BE ADVISED A MECHANICAL PERMIT (A/C) WILL BE NEEDED | | | FOR THE BATHROOM EXHAUST FAN. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-03 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-03 |
Time |
15:14 |
Sent To |
M |
|
| Notes |
| 2007-12-03 15:36:35 | DENIED; | | | 1.CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF WORK | | | PROPOSED AND SHOW IN DETAIL.SEE FBC BUILDING CHAPTER | | | 1 SECTION 106.1.1. RISER DIAGRAM IS NOT CLEAR AND DOES | | | NOT MATCH FLOOR PLAN FLAT PLAN. SHOW THE DIMENSIONS OF | | | THE 1/2 BATH, MUST HAVE 30" BETWEEN THE CENTER OF W/C | | | AND CENTER OF LAV. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-04 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-04 |
Time |
09:35 |
Sent To |
B |
|
| Notes |
| 2007-12-04 09:36:09 | ***APPROVED*** | | | | | | | | | SENT TO "B" - MISC. 3 |
|
|
|