Plan Review Details - Permit 07110219
| Plan Review Stops For Permit 07110219 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-10 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-10 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-02-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-08 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-08 |
Time |
10:22 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-02-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-05 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-05 |
Time |
09:23 |
Sent To |
P |
|
| Notes |
| 2008-02-05 09:48:45 | | | | | | | | | | APPLICATION #07110219 | | | ELECTRICAL PLAN REVIEW | | | 218 ALMERIA ROAD | | | 2/5/08 | | | WEST PALM BEACH, FL. | | | | | | THESE ARE REPEAT COMMENTS FROM THE 11/29/07 REVIEW, | | | THAT PREVIOUSLY WERE RESPONDED TO. NOW REAPPEAR WITH | | | THE LAST RESUBMITTAL. SEE ASTERISK FOR FURTHER | | | COMMENT. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | | | | 1} PLEASE LOCATE ALL SERVICE AND GENERATOR EQUIPMENT ON | | | A SITE PLAN, NOT THE SURVEY, METER ENCLOSURE, | | | DISCONNECTS, ATS AND PANELS, SO THAT COMPLIANCE WITH | | | ARTICLES 225, 250 AND 230 CAN BE REVIEWED. *THE SITE | | | PLAN SP1, INDICATES "125 AMPBOX", SHEET E3 INDICATES | | | ALL PANELS ARE 100 AMP. CORRELATE THE DRAWINGS TO | | | REFLECT THE PROPOSED EQUIPMENT , LABEL AND LOCATE | | | SAME. | | | | | | 2} PROVIDE A LOAD CALCULATION FOR THE LOAD INTENDED TO | | | BE SERVED. 215.5. 702.5, 2005NEC. * THECALCULATION FOR | | | THAT PANEL WERE NOT RESUBMITTED.WITH THE 1/10/08 | | | RESUBMITTAL. | | | | | | 3} PROVIDE A PANEL SCHEDULE FOR THE GENERATOR PANEL. | | | 106.3.5.4 FBC AS AMENDED.* THIS SCHEDULE WAS NOT | | | RESUBMITTED.WITH THE 1/10/08 RESUBMITTAL | | | | | | 5} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE | | | GENERATOR INDICATING RECOMMENDED SETBACKS FROM | | | STRUCTURES.* THOSE SPECIFICATIONS HAVE BEEN SUBMITTED | | | INDICATING A 18" SETBACK. THE NOTE ON SP1 INDICATES | | | "GENERATOR 13" FROM HOUSE", WHICH IS WHAT GENERATED | | | THIS COMMENT ORIGINALLY. | | | | | | 6} THERE ARE REFERENCES TO "8/0 AND 12/0" CONDUCTORS ON | | | THE RISER DIAGRAM. THESE ARE NOT LISTED AWG SIZES.* THE | | | "8/0" GROUND APPEARS IN ALL FEEDS, SHEET E3.ALSO NOTE | | | THE 3/0 FEEDERS, ALL PANELS, FOR A 100 AMP PANEL. | | | INDICATE WHAT THE NOTE "1-1/4"C. #4GROUNDING ELECTRODE | | | CONDUCTOR" IS IN REFERENCE TO, SITE ARTICLE TO | | | REFERENCE HE INTENT OF THAT NOTE. | | | | | | 7} THERE IS A "GROUNDING ELECTRODE CONDUCTOR" (250.66, | | | SEE DEFINITION) IN THE FEED FROM THE TRANSFER SWITCH TO | | | THE EM PANEL, AND ALL PANELS FED FROM THE MAIN. THIS | | | SHOULD BE AN EQUIPMENT GROUNDING CONDUCTOR (250.122), | | | AND SHOULD BE SIZED TO INDICATE COMPLIANCE. SEE | | | PREVIOUS COMMENT, SAME CONDITION STILL EXISTS. | | | | | | PLEASE CHECK ALL DOCUMENTS ARE CORRECTED AND PRESENT IN | | | THE PACKAGE THAT IS RESUBMITTED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-24 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-24 |
Time |
12:25 |
Sent To |
P |
|
| Notes |
| 2008-01-24 14:14:35 | | | | | | | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | THIS COMMENT WAS FROM THE PREVIOUS TWO REVIEW. | | | | | | 5} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE | | | GENERATOR INDICATING RECOMMENDED SETBACKS FROM | | | STRUCTURES.NOTE: HAVE NEVER SEEN GENERAC SPECIFY | | | ANYTING LESS THAN18". | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-01-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-11 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-11 |
Time |
10:27 |
Sent To |
P |
|
| Notes |
| 2008-01-11 10:47:11 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | | | | THIS COMMENT WAS FROM THE PREVIOUS REVIEW. | | | | | | 5} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE | | | GENERATOR INDICATING RECOMMENDED SETBACKS FROM | | | STRUCTURES. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-29 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-29 |
Time |
12:47 |
Sent To |
M |
|
| Notes |
| 2007-11-29 13:23:32 | | | | | | | APPLICATION #07110219 | | | ELECTRICAL PLAN REVIEW | | | 218 ALMERIA ROAD | | | 11/29/07 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | | | | 1} PLEASE LOCATE ALL SERVICE AND GENERATOR EQUIPMENT ON | | | A SITE PLAN, NOT THE SURVEY, METER ENCLOSURE, | | | DISCONNECTS, ATS AND PANELS, SO THAT COMPLIANCE WITH | | | ARTICLES 225, 250 AND 230 CAN BE REVIEWED. | | | | | | 2} PROVIDE A LOAD CALCULATION FOR THE LOAD INTENDED TO | | | BE SERVED. 215.5. 702.5, 2005NEC | | | | | | 3} PROVIDE A PANEL SCHEDULE FOR THE GENERATOR PANEL. | | | 106.3.5.4 FBC AS AMENDED. | | | | | | 4} PROVIDE SPECIFICATIONS FOR THE TRANSFER SWITCH. | | | | | | 5} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE | | | GENERATOR INDICATING RECOMMENDED SETBACKS FROM | | | STRUCTURES. | | | | | | 6} THERE ARE REFERENCES TO ?8/0 AND 12/0? CONDUCTORS ON | | | THE RISER DIAGRAM. THESE ARE NOT LISTED AWG SIZES. | | | | | | 7} THERE IS A ?GROUNDING ELECTRODE CONDUCTOR? (250.66, | | | SEE DEFINITION) IN THE FEED FROM THE TRANSFER SWITCH TO | | | THE EM PANEL, AND ALL PANELS FED FROM THE MAIN. THIS | | | SHOULD BE AN EQUIPMENT GROUNDING CONDUCTOR (250.122), | | | AND SHOULD BE SIZED TO INDICATE COMPLIANCE | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2008-02-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-02-08 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-02-08 |
Time |
13:49 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2008-02-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-02-05 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-02-05 |
Time |
11:58 |
Sent To |
PC |
|
| Notes |
| 2008-02-05 13:05:32 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | GAS PLAN REVIEW: | | | DENIED 4TH TIME: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE STILL | | | REQUIRED FOR GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | **PREVIOUS COMMENTS** | | | | | | 1. **OK** COMMENT ADDRESSED. | | | | | | 2. **OK** COMMENT ADDRESSED. | | | | | | 3. **OK** COMMENT ADDRESSED. | | | | | | 4. **OK** COMMENT ADDRESSED | | | | | | 5. **OK** COMMENT ADDRESSED. | | | | | | 6. **NO, COMMENT NOT ADDRESSED | | | **OK** COMMENT ADDRESSED, HOWEVER THE GAS PLANS FOR | | | THE GENERATOR ARE TO BE SUBMITTED SEPERATELY AS A | | | REVISION TO GAS PERMIT NUMBER 07020476 WITH FEES PAID | | | AND SUBMITTED WITH THE GENERATOR PERMIT. | | | | | | ****UNTIL GAS PLANS ARE SUBMITTED AS A REVISION TO GAS | | | PERMIT #07020476 WITH REVISION FEES PAID AS REQUSTED IN | | | THE PREVIOUS PLAN REVIEW DATED 1/25/08, THERE WILL NOT | | | BE A GAS PLAN REVIEW. ALSO PLEASE REFERENCE A COPY OF | | | THE NOTARIZED LETTER FROM "GUARANTEED PLUMBING INC." | | | CLOSING OUT GAS PERMIT #07110221 ATTACHED TO THESE | | | COMMENTS INDICATING THE NEED FOR THE GAS BE SUBMITTED | | | AS A REVISION. | | | | | | 7. **OK** COMMENT ADDRESSED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-01-25 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-01-25 |
Time |
11:16 |
Sent To |
PC |
|
| Notes |
| 2008-01-25 11:17:35 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | GAS PLAN REVIEW: | | | DENIED 3RD TIME: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE STILL | | | REQUIRED FOR GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | **PREVIOUS COMMENTS** | | | | | | 1. **OK** COMMENT ADDRESSED. | | | | | | 2. **OK** COMMENT ADDRESSED. | | | | | | 3. **OK** COMMENT ADDRESSED. | | | | | | 4. **NO** COMMENT NOTED HOWEVER. | | | PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE | | | GENERATOR INDICATING RECOMMENDED SETBACKS FROM | | | STRUCTURES. | | | | | | **THERE WERE NO MANUFACTURER'S SPECIFICATIONS | | | SUBMITTED FOR THE PROPOSED GENERATOR INDICATING | | | RECOMMENDED SETBACKS FROM STRUCTURES. | | | | | | ***NOTE: REFERENCE THE GENERAC "NEW INSTALLATION | | | GUIDELINES FOR GENERAC STATIONARY GENERATORS" ATTACHED | | | TO THE GAS COMMENTS THAT STATES GENERATOR AT A MINIMUM | | | IS 18" AND COMPLY. | | | | | | 5. **OK** COMMENT ADDRESSED. | | | | | | 6. **OK** COMMENT ADDRESSED, HOWEVER THE GAS PLANS FOR | | | THE GENERATOR ARE TO BE SUBMITTED SEPERATELY AS A | | | REVISION TO GAS PERMIT NUMBER 07020476 WITH FEES PAID | | | AND SUBMITTED WITH THE GENERATOR PERMIT. | | | | | | 7. **OK** COMMENT ADDRESSED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-01-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-01-14 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-01-14 |
Time |
13:59 |
Sent To |
PC |
|
| Notes |
| 2008-01-14 14:45:20 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | GAS PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE STILL | | | REQUIRED FOR GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | **PREVIOUS COMMENTS** | | | | | | 1. **OK** COMMENT ADDRESSED. | | | | | | 2. **OK** COMMENT ADDRESSED. | | | | | | 3. **OK** COMMENT ADDRESSED. | | | | | | 4. **NO** COMMENT NOTED HOWEVER. | | | PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE | | | GENERATOR INDICATING RECOMMENDED SETBACKS FROM | | | STRUCTURES. | | | | | | **THERE WERE NO MANUFACTURER'S SPECIFICATIONS | | | SUBMITTED FOR THE PROPOSED GENERATOR INDICATING | | | RECOMMENDED SETBACKS FROM STRUCTURES. | | | | | | 5. **OK** COMMENT ADDRESSED. | | | | | | 6. **NO** COMMENT NOTED HOWEVER. | | | NOTE: THERE IS AN OPEN GAS PERMIT #07020467 PRINTED FOR | | | THIS ADDRESS FOR "GUARANTEED PLUMBING INC.". PLEASE | | | CLARIFY WHY THE SUBMITTED GAS FOR THE GENERATOR WAS NOT | | | SUBMITTED AS A REVISION TO THAT PERMIT. IS IT THE | | | INTENT TO VOID OUT THAT PERMIT? PLEASE SUBMIT AN | | | ORIGINAL NOTARIZED LETTER BY SAID CONTRACTOR INDICATING | | | WHICH PERMIT IS TO BE VOIDED. | | | | | | **NOTE: UNTIL A NOTARIZED LETTER FROM SAID CONTRACTOR | | | IS SUBMITTED INDICATING WHICH GAS PERMIT IS TO BE | | | VOIDED THE GENERATOR PERMIT WILL NOT BE PRINTED. | | | | | | 7. **OK** COMMENT ADDRESSED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-04 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-04 |
Time |
10:51 |
Sent To |
B |
|
| Notes |
| 2007-12-04 11:32:19 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS | | | TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | GAS PLAN REVIEW: | | | DENIED: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. PER THE SUBMITTED MANUFACTURER'S SPECIFICATION | | | SHEETS THE GENERATOR BTU'S ARE INDICATED WRONG AS | | | 107,000. THE CORRECT BTU LOAD FOR THE GENERATOR IS | | | 315,000. PLEASE CORRECT THIS ON THE RESUBMITTAL. | | | | | | 2. THE TOTAL BTU'S FOR THE GAS SYSTEM ARE BEING | | | INDICATED WRONG AS 207,000. THE CORRECT TOTAL BTU LOAD | | | FOR THE GAS SYSTEM IS 415,000. PLEASE CORRECT THIS ON | | | THE RESUBMITTAL. | | | | | | 3. PER FUEL GAS TABLE 402.4(2) THE SCHEDULE 40 | | | METALLIC PIPE NEEDS TO BE INCREASED FROM 1" TO 1-1/4" | | | FROM THE METER TO THE GENERATOR. PLEASE CORRECT THIS ON | | | THE RESUBMITTAL. | | | | | | 4. PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE | | | GENERATOR INDICATING RECOMMENDED SETBACKS FROM | | | STRUCTURES. | | | | | | 5. CLEARLY INDICATE THE GENERATORS LOCATION ON A SITE | | | PLAN OR SURVEY INDICATING DIMENSIONS FROM PROPERTY | | | LINES AND DISTANCES FROM ADJACENT DWELLING STRUCTURES. | | | | | | 6. NOTE: THERE IS AN OPEN GAS PERMIT #07020476 PRINTED | | | FOR THIS ADDRESS BY GUARANTEED PLUMBING INC.. PLEASE | | | CLARIFY WHY THE SUBMITTED GAS FOR THE GENERATOR WAS NOT | | | SUBMITTED AS A REVISION TO THAT PERMIT. IS IT THE | | | INTENT TO VOID OUT THAT PERMIT? PLEASE SUBMIT AN | | | ORIGINAL NOTARIZED LETTER BY SAID CONTRACTOR INDICATING | | | WHICH PERMIT IS TO BE VOIDED. | | | | | | 7. FBC-2004 CHAPTER 1,SECTION 106.3.4.3: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-07 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-07 |
Time |
08:54 |
Sent To |
E |
|
| Notes |
| 2008-02-07 08:55:14 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-15 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-15 |
Time |
16:22 |
Sent To |
E |
|
| Notes |
| 2008-01-15 16:22:44 | TO "BTROBAUG" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-10 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2008-01-10 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2008-01-10 |
Time |
16:03 |
Sent To |
E |
|
| Notes |
| 2008-01-10 16:03:42 | SENT TO BT'S DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-10 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-09 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2007-11-09 08:32:06 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-30 |
Time |
12:07 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-11-30 |
Time |
12:07 |
Sent To |
G |
|
| Notes |
| 2007-11-30 12:10:24 | *** PROVISO *** | | | 1) PER 2004 FBC, FUEL GAS - POWERED EQUIPMENT | | | PERMANENTLY INSTALLED EQUIPMENT POWERED BY INTERNAL | | | COMBUSTION ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND NFPA | | | 37. | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: 4.1.4ENGINES | | | (GENERATORS) LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT | | | FROM OPENINGS IN WALLS & AT LEAST 5 FT FROM STRUCTURES | | | HAVING COMBUSTIBLE WALLS.A MINIMUM CLEARANCE IS NOT | | | REQUIRED WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF | | | ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, | | | AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. INFORMATIVE: A.8.2.3.1 | | | EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER STRUCTURES | | | OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO THE VENTILATION | | | INTAKES. | | | 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS | | | LOCATED BELOW AN ADJACENT ROOF STRUCTURE, THE | | | TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF | | | STRUCTURE. | | | PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL | | | EQUIPMENT TO ENCROACH 4 FT INTO THE REQUIRED SETBACK, | | | GENERATORS SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED | | | CLEARANCES TO THE ADJACENT PROPERTY STRUCTURES, I.E. | | | FENCE, BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | FOLLOW MANUFACTURER'S RECOMMENDED CLEARANCES | | | AROUND EQUIPMENT FOR SERVICING,AND PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS AT THE JOBSITE | | | FOR THE FIELD INSPECTOR. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-14 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-14 |
Time |
13:35 |
Sent To |
E |
|
| Notes |
| 2007-11-14 13:35:54 | ***APPROVED*** | | | | | | | | | SENT TO "E" - GEN. BOX |
|
|
|