| Plan Review Stops For Permit 07110196 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2010-07-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-07-20 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-07-20 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2010-07-20 15:57:14 | NEW GARAGE FLAT ROOF PRODUCT APPROVAL SUBMITTED UNDER | | | PERMIT NUMBER 10070494. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-08-18 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-08-18 |
Time |
09:30 |
Sent To |
PC |
|
| Notes |
| 2008-08-18 14:13:40 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- FLAT ROOF SYSTEM: | | | A) SPECIFYWHICH APPROVED ASSEMBLY OF NA 08-0512.06 | | | IS GOING TO BE USED. | | | B) ON SELECTED ASSEMBLY SPECIFY WHICHBASE SHEET | | | FASTENING OPTION IS GOING TO BE USED.COORDINATE WITH | | | THE RAS 117 C CALCULATIONS SUBMITTED. | | | C) ENGINEERWHO PERFORMED THE RAS 117 CALCULATIONS | | | NEEDS TO PROVIDE ALL HIS INFORMATION AS REQUIRED BY | | | CHAPTER 471 FLORIDA STATUTE AND SEC. 61G15-23.002 | | | FLORIDA ADMINISTRATIVE CODE. | | | D) RAS 117 CALCULATIONS SUBMITTED: CLARIFY WHERE IS | | | SECTION 10.4 FBC 2004 TAKEN FROM? | | | | | | 2- ENERGY CALCULATIONS FOR GARAGE BUILDING: | | | A) SUBMITREVISED FORM 600C-04R. | | | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | | | | C) COMPLETE ALL INFORMATION ON BACK OF FORM. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-24 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-24 |
Time |
13:19 |
Sent To |
PC |
|
| Notes |
| 2008-06-24 13:20:54 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-VERIFY THAT 5'-0" SPIRAL STAIRS IS INSTALLED. | | | 2- SOIL TEST REPORT STATESSOILBEARING CAPACITY OF | | | 2,000PSF.ENGINEER OF RECORD REQUIRES 2,500 PSF SOIL | | | BEARING CAPACITY. SEE FOUNDATION NOTES ON SHEET S-5. | | | REVISE AS REQUIRED. | | | 3- PROVIDE COMPLETE PRODUCT APPROVAL FOR UNDERLAYMENT | | | USED IN BALCONY ASSEMBLY.SEE SHEET A3.4. | | | 4- PROVIDE PRODUCT APPROVAL FOR FLAT ROOF IF DOING ANY | | | FLAT ROOF RE-ROOFING. SEE SHEET A2.2.. | | | 5- REVISE ENERGY CALCULATIONS FOR GARAGE BUILDINGTO | | | SHOWR-VALUE INSULATION ON WALLS AND CEILINGS. SEE | | | ARCHITECTURAL DRAWINGS. | | | 6- TRUSS PACKAGE TO HAVE NAME OF ENGINEER OF RECORD ON | | | INDEX SHEET AS REQUIRED BYSEC. 61G15-31.003(5). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-04-25 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-25 |
Time |
17:28 |
Sent To |
PC |
|
| Notes |
| 2008-04-25 19:00:54 | RESIDENTIAL (R3) ADDITION AND ALTERATION, BUILDING | | | REVIEW SECOND CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP | | | TO AVOID EXPIRATION OF DOCUMENT. | | | | | | 2- NEED TO PROVIDE COPY OF IMPACT FEES PAID RECEIPT. | | | (REPEAT COMMENT).ONLY PLANS WITH IMPACT FEES STAMP | | | WAS SUBMITTED THIS TIME.NEED TO PROVIDE BOTH. | | | | | | 3-ACCORDING TOSPIRAL STAIRS INFORMATION SUBMITTED, | | | ONLY 5'-0" DIAMETER STAIRS OR LARGER COMPLY WITH THE | | | MINIMUM REQUIREMENTS.ARCHITECTURAL PLANS SHOW 4'-9" | | | DIAMETER FOR STAIR OPENING. PLANS NEED TO BE REVISED AS | | | REQUIRED TO ACCOMMODATEMIN. 5'-0" DIAMETER STAIRS. TO | | | COMPLY WITH SEC. R311.5.8.1 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | SPECIFY TOTAL NUMBER OF RAISERS REQUIRED TO VERIFY | | | COMPLIANCE WITH MAXIMUM RISER HEIGHT. | | | | | | 4- PROVIDE COMPLETE DETAILS/SPECS FOR ORNAMENTAL | | | GUARDRAIL TO VERIFY COMPLIANCE WITH TABLE R301.5 AND | | | SEC. R312.2 OF 2004 FLORIDA RESIDENTIAL CODE. | | | INFORMATION SUBMITTEDFROM RAILING WORKS IS ONLYFOR | | | GENERALINFORMATION AND DOESN'T PROVIDEINFORMATION | | | FOR ACTUAL PROPOSED ORNAMENTAL RAILING. | | | | | | 5- PROVIDE PRODUCT APPROVALS AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) POLYFOAM USED FOR ROOF TILE. (REPEAT COMMENT). | | | SEE ROOF TILE PRODUCT APPROVAL FOR LISTED POLYFOAM. | | | | | | B) FLAT ROOF: NEED TO SPECIFY WHICH APPROVED | | | ASSEMBLY AND SPECIFIC FASTENING OPTION IS GOING TO BE | | | USED. ALSO, NEED TO PROVIDE THE RAS 117 CALCULATIONS | | | FOR NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7.SEE GENERAL | | | LIMITATIONS ON LAST PAGE OF NOA 07-0111.03 SUBMITTED. | | | (REPEAT COMMENT). | | | | | | C) ARCHED DOORS AS SHOWN ON GARAGE EXTERIOR | | | ELEVATIONS. (REPEAT COMMENT). | | | | | | D) DOUBLE HUNG WINDOWS.MARVIN WINDOWS AND DOORS | | | FLORIDA PRODUCT APPROVAL FL4765-R0 IS MISSING THE | | | DRAWINGS SHOWING THE WINDOWS.PROVIDE COMPLETE | | | DRAWINGS. | | | | | | E) MULLIONS. CLEARLY MARK SPECIFIC MULLION SIZE AND | | | ANCHORING TO BE USED TO VERIFY COMPLIANCE WITH THE | | | CALCULATED DESIGN PRESSURES. | | | | | | ***NOTE:THERE ARE PRODUCT APPROVALSFOR DOORS AND | | | WINDOWS FROM PGT AND FROM MARVIN WINDOWS AND DOORS. | | | PROVIDE ONLY THE PRODUCTAPPROVALFOR SPECIFIC | | | PRODUCT THAT IS GOING TO BE INSTALLED.PGT OR MARVIN. | | | | | | 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY | | | AMENDMENTS TO FBC 2004. SOME PRODUCT APPROVALS ARE | | | MISSING THE ARCHITECT'S REVIEW STAMP. | | | | | | 7- PROVIDE COMPLETE SPECIFICATIONS FOR RAISED WOOD | | | FLOOR IN GARAGE AREAAND RAISED WOOD FLOOR IN NEW | | | ADDITION AREA TO SHOW COMPLIANCE WITH SECTIONS R319 | | | (PROTECTION AGAINST DECAY)AND SEC. R408.1 THRU | | | R408.3 OF 2004 FLORIDA RESIDENTIAL CODE (UNDER-FLOOR | | | SPACE VENTILATION AND ACCESS).(REPEAT COMMENT). THERE | | | ARE NO SPECS PROVIDED TO SHOW COMPLIANCE WITH SEC. | | | R319. AND, LOCATION OF VENTILATION OPENINGSNEED TO BE | | | BETWEEN 3' OF EACH CORNER AS REQUIRED BY SEC. R408.1. | | | REVISEPLANS AS REQUIRED. | | | | | | 8- ENERGY CALCULATIONS: | | | A) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | | | | B) COMPLETE INFORMATION ON TOP OF FORM. (REPEAT | | | COMMENT). | | | | | | 9-SOIL TEST REPORT SHOWS SOIL BEARING CAPACITY OF | | | 2000 PSF AND RECOMMENDS MINIMUM FOOTING WIDTH OF 24". | | | STRUCTURAL PLANS REQUIRE 2500PSF SOIL BEARING CAPACITY | | | AND FOOTING WIDTH IS LESS THAN THE ONE RECOMMENDED ON | | | THE SOIL TEST REPORT.STRUCTURAL ENGINEER TO | | | COORDINATEWITH GEO-TECHNICAL ENGINEER AND REVISE | | | EITHER ONE THE SOIL TEST REPORT OR STRUCTURAL DRAWINGS | | | AS REQUIRED. | | | | | | 10- SHEET A5.0:REVISE NAIL TYPETO BE USED FOR ROOF | | | SHEATHING ON DETAIL #18.SEC. R803.2.3.1 REQUIRES MIN. | | | 8D RING SHANK NAILS. REVISE AS REQUIRED. | | | | | | 11- SHEET A6: REVISE INSULATION SPECIFICATIONS ON ALL | | | WALL ASSEMBLIES SHOWN ON THE WALL SCHEDULE. COORDINATE | | | WITH THE ENERGY CALCULATIONS AND REVISE AS REQUIRED. | | | (REPEAT COMMENT). | | | | | | 12- SHEET S-4:REVISE ALL INFORMATION ON DETAIL C | | | REGARDING THE ROOF SHEATHING FASTENER TYPE AND SPACING. | | | SEE SEC. R803.2.3.1 FOR MINIMUM TYPE OF NAIL AND | | | SPACING REQUIRED INCLUDING ON ROOF ZONE #3. | | | | | | 13- TRUSS PACKAGE: | | | A) ENGINEER OF RECORD NEEDS TO REVIEW AND APPROVE | | | TRUSS PACKAGE PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | B) TRUSS DRAWINGS NEED TO HAVE ENGINEER'S ORIGINAL | | | SIGNATURE AS REQUIRED BY SEC. 61G15-23.002 FLORIDA | | | STATUTE. AND CHAPTER 472 FLORIDA STATUTE. | | | | | | C) TRUSS COVER SHEET IS MISSING THE INFORMATION | | | REGARDING THE ENGINEER OF RECORD. PROVIDE THIS | | | INFORMATION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-11-19 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-11-19 |
Time |
15:26 |
Sent To |
P |
|
| Notes |
| 2007-11-19 15:30:14 | RESIDENTIAL ADDITION BUILDING REVIEW CHECKLIST. | | | REVIEW DONE UNDER EXISTING BUILDING CODE 2004, FLORIDA | | | RESIDENTIAL CODE 2004 AND FBC 2004 WITH 2007 | | | REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | | | | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO | | | VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS | | | AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | | | | | 3-A) NEW ADDITION NEEDS TO COMPLY WITH SEC. R302.1 | | | AND R302.2 OF 2004 FLORIDA RESIDENTIAL CODE REGARDING | | | WALL FIRE RATING, ROOF PROJECTIONS AND NO OPENINGS | | | ALLOWED ON EAST WALL. | | | | | | B) SAME COMMENT APPLIES TO GARAGE RENOVATION AND | | | ALTERATION ON WEST WALL. | | | | | | 4- PROVIDE SPECIFICATIONS FOR GARAGE SWING DOOR LEADING | | | TO THE WORKROOM AREA FOR COMPLIANCE WITH SEC. R309.1 OF | | | 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 5- PROVIDE DETAILS/SPECS FOR SPIRAL STAIRS SHOWING | | | COMPLIANCE WITHSEC. R311.5.8.1 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 6- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. 106.1.1.2 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | NOTE: ATTACHMENT METHOD MUST MEET THE DESIGNER'S | | | CALCULATED UPLIFT MOMENT. SEE PRODUCT APPROVAL. | | | | | | 7- PROVIDE COMPLETE DETAILS/SPECS FOR ORNAMENTAL | | | GUARDRAIL TO VERIFY COMPLIANCE WITH TABLE R301.5 AND | | | SEC. R312.2 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) ROOF TILE. | | | | | | B) ROOF TILE ADHESIVE IFSPECIFIED BY THE DESIGNER | | | OF RECORD ON ITEM 6 ABOVE. SEE TILE PRODUCT APPROVAL | | | FOR SPECIFICADHESIVE TO BE USED. | | | | | | C) FLAT ROOF. AND, CLEARLY SPECIFY WHICH APPROVED | | | ASSEMBLY IS GOING TO BE INSTALLED.IF MORE THAN ONE | | | FASTENING OPTION IS LISTED IN THE SELECTED APPROVED | | | ASSEMBLY, THEN SPECIFY SELECTED FASTENING OPTION. ALSO, | | | PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT THE | | | PERIMETER AND CORNER AREAS. SEE GENERAL LIMITATION #7 | | | ON PRODUCT APPROVAL.IF CALCULATIONS NEED TO BE DONE | | | AND SEALED BY ARCHITECT OR ENGINEER, THEN PROVIDE SUCH | | | CALCULATIONS. | | | | | | D) ARCHED DOORSAS SHOWN ON EXTERIOR ELEVATIONS. | | | | | | 9- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 10- PROVIDE COMPLETE SPECIFICATIONS FOR RAISED WOOD | | | FLOOR IN GARAGE AREA AND RAISED WOOD FLOOR IN NEW | | | ADDITION AREA TO SHOW COMPLIANCE WITH SECTIONS R319 | | | (PROTECTION AGAINST DECAY),AND SEC. R408.1 THRU | | | R408.3 OF 2004 FLORIDA RESIDENTIAL CODE (UNDER-FLOOR | | | SPACE VENTILATION AND ACCESS). | | | | | | 11- ENERGY CALCULATIONS: | | | A) PROVIDE SEPARATE ENERGY CALCULATIONS FOR GARAGE | | | AND FOR NEW ADDITION AS REQUIRED BY SEC. 13-101.2.5.1 | | | FBC 2004. | | | NOTE: MAKE SURE CORRESPONDING A/C AREA IS USED FOR EACH | | | BUILDING. | | | | | | B) NEED TO USE REVISED FORM 600A-200R. | | | | | | C) COMPLETE ALL INFORMATION ON TOP OF FORM. | | | | | | D) MAKE SURE CORRECT OVERHANG HEIGHT AND LENGTH IS | | | USED. SEE ARCHITECTURAL PLANS AND REVISE AS REQUIRED. | | | | | | E) MAKE SURE CORRECT R-VALUES AE SHOWN FOR EXTERIOR | | | WALLS. SEE SEC. 13-602.1.ABC.1 OF FBC 2004. | | | | | | 12- PROVIDE SOIL TEST REPORT.TWO COPIES. SEC. R401.4 | | | OF 2004 FLORIDA RESIDENTIAL CODE. | | | NOTE: PLEASE MAKE SURE SOIL TEST REPORT HAS ENGINEER'S | | | ORIGINAL SEAL AND SIGNATURE AND ENGINEERING FIRM | | | CERTIFICATE OF AUTHORIZATION NUMBER IS PROVIDED AS | | | REQUIRED BY SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE | | | CODE TO AVOID DELAYS. | | | | | | 13- SHEET A3.2: WALL SECTIONS CALLS FOR NEW 3/4" STUCCO | | | ON PLAYWOOD ON METAL STUD FRAMED WALLS, WHILE | | | STRUCTURAL DRAWINGS CALL FOR WOOD FRAMING. REVISE AS | | | REQUIRED. | | | NOTE: THIS COMMENT APPLIES TO WALL SECTIONS ON SHEETS | | | A3.3,A3.4AND A3.5ALSO. | | | REVISE AS REQUIRED. | | | | | | 14- SHEET A3.4:PROVIDE COMPLETE DETAIL/SPECS FOR | | | INSTALLATION OF 1" BRICK PAVERS SET ON FLOATING WOOD | | | DECK IN BALCONY.SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004 IN REFERENCE TO WIND LOADS SEC. R301 OF 2004 | | | FLORIDA RESIDENTIAL CODE. | | | | | | 15- SHEET A5.0: PROVIDECOMPLETE SPECIFICATION FOR ALL | | | FASTENERS TO BE USED ON SECTION/DETAIL 18 FOR CANOPY | | | INSTALLATION. | | | | | | 16- SHEET A6.0:REVISE INSULATION SPECIFICATIONS ON | | | ALL WALL ASSEMBLIES SHOWN ON THE WALL SCHEDULE. | | | COORDINATE WITH ENERGY CALCULATIONS AND REVISE AS | | | REQUIRED. | | | | | | 17- SHEET S-4: | | | A) REVISE LOCATION OF ZONE 3 SHOWN ON DETAILB. SEE | | | FIGURE 6-11C OF ASCE 7-02AND REVISE AS REQUIRED. | | | | | | B) DETAIL C : INFORMATION FOR ZONE 1,2 & 3 DOESN'T | | | MATCH INFORMATION SHOWN BY 2X4 BLOCKING. ALSO, SEE SEC. | | | R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE FOR MINIMUM | | | TYPE OF NAIL AND NAIL SPACING TO BE USED, INCLUDING | | | NAIL SPACING IN ZONE 3 AREAS. REVISE ALL INFORMATION ON | | | THIS DETAIL AS REQUIRED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-18 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-31 |
Time |
07:59 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-14 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-14 |
Time |
12:13 |
Sent To |
M |
|
| Notes |
| 2007-11-14 16:20:37 | | | | | | | APPLICATION #07110196 | | | ELECTRICAL PLAN REVIEW | | | 711 CLAREMORE DRIVE | | | 11/14/07 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | | | | 1} REFERENCING THE RISER DIAGRAM FOR THE HOUSE SUBPANEL | | | ON SHEET E3, THE FEEDER TO THAT PANEL MUST HAVE AN | | | EQUIPMENT GROUND (#8 MINIMUM) PER 250.122. | | | | | | 2} THE HOUSE SUBPANEL CANNOT BE LOCATED IN THE BATHROOM | | | AS INDICATED ON SHEET E1, 1ST FLOOR ELECTRICAL PLAN. | | | SEE ARTICLE 240.24(E). | | | | | | 3} SHEET E2, THE RISER FOR THE CABANA INDICATES THAT | | | SERVICE IS EXISTING, THE CABANA PANELBOARD INDICATES | | | ?NEW?. CLARIFY IF NEW OR EXISTING, INDICATE THE | | | GROUNDING ELECTRODE CONDUCTOR SIZE PER 250.66, MINIMUM | | | #6. | | | | | | 4} THE 1? CONDUIT CONTAINING 3#1/0 CONDUCTORS FOR THE | | | CABANA PANEL FEED IS IN VIOLATION OF THE CONDUIT FILL | | | REQUIREMENTS. SEE ANNEX ?C? OR CALCULATE FROM TABLE | | | #8. | | | | | | 5} THE CABANA PANEL LOCATION APPEARS NOT TO HAVE THE 3? | | | CLEARANCE REQUIRED PER 110.26. PLEASE VERIFY. | | | | | | 6} THE LOAD CALCULATIONS ARE NOT PER 220.82 OR 220.83 | | | AS THEY SHOULD BE FOR AN EXISTING RESIDENCE. THERE ARE | | | LOADS ON THE PANEL SCHEDULES NOT PART OF THE | | | CALCULATIONS IG; WARMER, WATER HEATER, RANGE IN PANEL | | | ?H?.ALSO THERE ARE LOADS FROM THE CABANA SERVICE | | | LISTED IN THE HOUSE SERVICE CALCULATIONS. THESE | | | SERVICES MUST BE CALCULATED AND LISTED SEPARATELY AS | | | THEY ARE FROM SEPARATE SERVICES NOT SEPARATE PANELS ON | | | THE SAME SERVICE. | | | | | | 7} REGARDING THE CABANA FLOOR PLAN SHEET E1, LOCATE THE | | | WASHER AND DRYER LISTED ON THE PANEL SCHEDULE. | | | | | | 8} THE BATHROOM IN THE CABANA IS REQUIRED TO HAVE A | | | CIRCUIT FOR THE RECEPTACLE SEPARATE PER 210 52(D). IT | | | IS ON WITH OTHER RECEPTACLES OUTSIDE OF THAT ROOM. | | | | | | 9} THE LOFT BATHROOM MUST COMPLY WITH 210.52(D) | | | RECEPTACLE REQUIREMENT. | | | | | | 10} THE LAUNDRY OFF THE MASTER BEDROOM MUST COMPLY WITH | | | 210.11(C)(2), LAUNDRY BRANCH CIRCUIT. PANEL MUST BE | | | LABELED INDICATING SAME PER 408.4. | | | | | | 11} ALL BEDROOM OUTLETS MUST COMPLY WITH 210.12 ARC | | | FAULT PROTECTED. INDICATE IN THE PANELS. | | | | | | 12} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS | | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | | INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE | | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE | | | ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE | | | LOCATIONS OF REQUIRED ALARMS ON THE PLANS AND NOTE THE | | | REQUIREMENT FOR INTERCONNECTING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2008-01-29 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2008-01-29 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2008-01-29 10:54:04 | HISTORICAL APPROVAL PER FRIEDERIKE MITTNER | | 2007-11-08 10:22:30 | NO HISTORIC FEE & OK PER G JUDGE 11-8-07 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-14 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-14 |
Time |
15:28 |
Sent To |
M |
|
| Notes |
| 2008-08-14 15:29:16 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-06-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-13 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-13 |
Time |
13:23 |
Sent To |
M |
|
| Notes |
| 2008-06-13 13:23:29 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-16 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-16 |
Time |
13:45 |
Sent To |
E |
|
| Notes |
| 2008-04-16 13:45:27 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-29 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-29 |
Time |
14:18 |
Sent To |
Z |
|
| Notes |
| 2008-01-29 14:18:56 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-27 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-08 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2007-11-08 14:07:38 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-15 |
Time |
10:19 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-08-15 |
Time |
10:19 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-16 |
Time |
10:15 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-06-16 |
Time |
10:15 |
Sent To |
B |
|
| Notes |
| 2008-06-16 10:17:18 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) 2) AS NOTED IN LAST TWO REVIEWS 11/15/07 AND 4/18/08 | | | NOTE #2. PROVIDE FOR RETURN AIR FOR THE NEW LOFT, SEE | | | 2004 FBC/R M1602.2. ENGINEERS RESPONSE WAS, THE STAIR | | | TO THE LOFT IS OPEN AT THE CEILING ETC. PLEASE SEE THAT | | | THE STAIR TO THE LOFT IS CLOSED OFF AT THE BOTTOM FROM | | | THE RETURN AIR GRILL IN THE MASTER BEDROOM BY A WALL | | | AND A DOOR SO RETURN AIR CAN NOT RETURN TO THE AIR | | | HANDLER. PLEASE CORRECT. | | | | | | 2) MECHANICAL PLAN M1 NOW SHOWS 6"X6" METAL CURB | | | (SLEEPERS) AND PLAN A5.0 DETAIL 19, SHOWS 8" METAL CURB | | | (SLEEPERS). PER 2004 FBC TABLE 1509.7 CLEARANCE BELOW | | | RAISED ROOF MOUNTED MECHANICAL UNITS. THE MINIMUM | | | CLEARANCE ABOVE ROOF SURFACES IS 14" PLEASE CHECK THE | | | TABLE AS THE UNIT YOU ARE INSTALLING MAY REQUIRE MORE | | | CLEARANCE. SEE 2004 FBC/R M1301.1, FBC/M 306.5, AND | | | FBC1509.7. PLEASE CORRECT. | | | | | | 3)AS NOTED IN LAST TWO REVIEWS 11/15/07 AND 4/18/08 | | | NOTE #4. PLEASE SUBMIT PRODUCT APPROVAL OR AN NOA FOR | | | PER-ENGINEERED A/C CONDENSER STANDS (IF USED), SEE FS | | | 553.842(1) AND FAC RULE 9B-72, 9B-72.005, AND FAC | | | 9B-72.010(31)(G). | | | | | | 6) SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING FOUR | | | TIMES THE FEE. | | | | | | *** PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | *** WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL | | | (A SHOP REVIEW STAMP AND SIGNATURE WILL MEET THIS | | | REQUIREMENT). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-18 |
Time |
10:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-18 |
Time |
10:33 |
Sent To |
P |
|
| Notes |
| 2008-04-18 10:49:22 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 11/15/07 NOTE #1. PLEASE | | | SUBMITCOOLING LOAD CALCULATIONS (MANUAL J | | | CALCULATIONS) SEE 2004 FBC 13-607.1.ABC.1. ONE SET OF | | | THE ENERGY CALCULATIONS FOR THE CABANA HAS A ONE SHEET | | | SUMMARY SHEET '?' SEE THE EXCEPTION TO 13-607.1.ABC.1. | | | | | | 2) AS NOTED IN LAST REVIEW 11/15/07 NOTE #2. PROVIDE | | | FOR RETURN AIR FOR THE NEW LOFT, SEE 2004 FBC/R | | | M1602.2. | | | | | | 3)AS NOTED IN LAST REVIEW 11/15/07 NOTE #3. PLAN M4 | | | CONDENSER UNIT ROOF DETAIL, SHOWS A 6'X6' P.T. SLEEPER. | | | PER 2004 FBC/M 301.13 THE USE OF WOOD SLEEPERS SHALL | | | NOT BE PERMITTED. PLEASE CORRECT. | | | | | | 4)AS NOTED IN LAST REVIEW 11/15/07 NOTE #4. PLEASE | | | SUBMIT PRODUCT APPROVAL OR AN NOA FOR PER-ENGINEERED | | | A/C CONDENSER STANDS (IF USED), SEE FS 553.842(1) AND | | | FAC RULE 9B-72, 9B-72.005, AND FAC 9B-72.010(31)(G). | | | | | | 5) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-103.3. | | | | | | 6) SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING FOUR | | | TIMES THE FEE. | | | | | | *** PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | *** WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL | | | (A SHOP REVIEW STAMP AND SIGNATURE WILL MEET THIS | | | REQUIREMENT). | | | | | | **** UNDER 2004 FBC 13-407.1.ABC.1 " EXCEPTIONS" A | | | SUMMARY SHEET MAY BE SUBMITTED WHEN SIGNED AND SEALED | | | BY THE ENGINEER AND HAS THE MINIMUM INFORMATION ON IT. | | | **PROJECT NAME/OWNER... **PROJECT ADDRESS... **SIZING | | | METHOD USED... **AREA IN SQUARE FEET... **OUTDOOR DRY | | | BULB USED... **OUTDOOR WET BULB USED... **RELATIVE | | | HUMIDITY... **INDOOR DRY BULB.... **TOTAL HEATING | | | REQUIRED WITH OUTSIDE AIR... **TOTAL SENSIBLE GAIN... | | | **TOTAL LATENT GAIN... **GRAINS WATER (DIFFERENCE)... | | | **TOTAL COOLING REQUIRED WITH OUTSIDE AIR. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-31 |
Time |
09:00 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-11-15 |
Time |
14:15 |
Sent To |
P |
|
| Notes |
| 2007-11-15 14:50:11 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLEASE SUBMITCOOLING LOAD CALCULATIONS (MANUAL J | | | CALCULATIONS) SEE 2004 FBC 13-607.1.ABC.1. | | | | | | 2) PROVIDE FOR RETURN AIR FOR THE NEW LOFT, SEE 2004 | | | FBC/R M1602.2. | | | | | | 3) PLAN M4 CONDENSER UNIT ROOF DETAIL, SHOWS A 6'X6' | | | P.T. SLEEPER. PER 2004 FBC/M 301.13 THE USE OF WOOD | | | SLEEPERS SHALL NOT BE PERMITTED. PLEASE CORRECT. | | | | | | 4) PLEASE SUBMIT PRODUCT APPROVAL OR AN NOA FOR | | | PER-ENGINEERED A/C CONDENSER STANDS (IF USED), SEE FS | | | 553.842(1) AND FAC RULE 9B-72, 9B-72.005, AND FAC | | | 9B-72.010(31)(G). | | | | | | *** PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | *** WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL | | | (A SHOP REVIEW STAMP AND SIGNATURE WILL MEET THIS | | | REQUIREMENT). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-21 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-21 |
Time |
07:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-27 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-27 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2007-11-27 15:05:25 | DENIED; | | | 1. CABANA SANITARY RISER DIAGRAM; THE SINK SHALL | | | DISCHARGE DOWN STREAM OF THE BATHROOM GROUP. SEE FBC | | | PLUMBING SECTION 909.1. | | | 2. 1ST FLOOR SANITARY RISER DIAGRAM; THE AUTOMATIC | | | CLOTHES WASHER SHALL DISCHARGE INTO A 3"BRANCH DRAIN. | | | SECTION 406.3. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-30 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-30 |
Time |
16:21 |
Sent To |
E |
|
| Notes |
| 2008-01-30 16:28:21 | ***APPROVED - RESUB #1*** | | | | | | PROVISO:1) HEIGHT OF PROPOSED ADDITION SHALL NOT | | | EXCEED 30', MEASURED FROM GRADE TO THE MIDPOINT OF THE | | | ROOF'S PITCH. 2) AS THE EXISTING ACCESSORY GARAGE | | | STRUCTURE IS DIMENSIONALLY NONCONFORMING WITH RESPECT | | | TO ITS SETBACKS FROM THE WEST SIDE AND REAR PROPERTY | | | LINES, THOSE NONCONFORMITIES SHALL NOT BE INCREASED NOR | | | SHALL ANY NEW NONCONFORMITIES BE CREATED.3) ROOF | | | OVERHANGS SHALL NOT PROJECT INTO ANY REQUIRED SETBACK | | | MORE THAN 3'. | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-08 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-08 |
Time |
16:01 |
Sent To |
E |
|
| Notes |
| 2007-11-08 16:02:58 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF AN UPDATED SURVEY | | | (WITHIN THE LAST YEAR) | | | | | | 2)INDICATE HEIGHT OF PROPOSED ADDITION ON ELEVATIONS | | | FROM GRADE TO THE MIDPOINT OF THE ROOF'S PITCH. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|