Plan Review Details - Permit 07110133
| Plan Review Stops For Permit 07110133 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-03-27 |
|
|
Cont ID |
|
| Sent By |
wlehnhar |
Date |
2008-03-27 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
wlehnhar |
Date |
2008-03-27 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2008-03-27 09:12:50 | PASSED REVIEW PER D V PALMER |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-03-07 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-03-07 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2008-03-07 15:05:34 | PLANS OK | | | | | | CONTRACTOR TO SUBMIT (3) COPIES OF CALCULATION SHEETS | | | ON TUESDAY 3/11/08. AT THAT TIME, PERMIT CAN BE PRINTED | | | AND ISSUED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-11-21 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-11-21 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2007-11-21 11:15:11 | ***DENIED*** | | | | | | 1) THE ADDRESS ON THE PERMIT APPLICATION REFLECTS 800 | | | CLEMATIS ST. AND THE PLANS INDICATE 111 S. SAPODILLA | | | AVE. PLEASE CORRELATE AND ADD CORRECT ADDRESS TO ALL | | | APPLICABLE DOCUMENTS, IE. DRAWINGS, HYDRAULIC | | | CALCULATIONS, SPECIFICATION SHEETS ETC. | | | | | | 2) CALCULATION SHEETS INDICATE REQUIRED AND AVAILABLE | | | PRESSURE. PLEASE ADD THE WORD SAFETY MARGIN TO CALC | | | SHEETS IF THAT IS BEING REFERENCED. | | | | | | 3) DETAILS HAVE BEEN PROVIDED FOR A FIRE PUMP. PLEASE | | | INCLUDE MANUFACTURER SPECIFICATION OR CUT SHEETS FOR | | | EQUIPMENT. | | | | | | 4) STANDPIPE CONNECTIONS OR FDV'S TO BE 2 1/2"- 1 1/2" | | | REDUCER WITH CHAINS. PLEASE ADD TO DRAWINGS. | | | | | | 5) NEW FIRE DEPARTMENT CONNECTIONS TO BE SECURED WITH | | | KNOX LOCKING CAPS. | | | | | | 6) IF SPRINKLER SYSTEM CONNECTS TO A NEW DOUBLE | | | DETECTOR CHECK ASSEMBLY, PLEASE PROVIDE INFORMATION AND | | | DETAIL ON SPECIFIC EQUIPMENT. A NEW 6" FIRE DEPARTMENT | | | SERVICE IS SHOWN ON SHEET FP-1. IN ADDITION TO | | | ELECTRONIC SUPERVISION, CONTROL VALVES TO BE SECURED | | | WITH CHAIN AND LOCK. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-27 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-27 |
Time |
15:48 |
Sent To |
FIRE |
|
| Notes |
| 2008-02-27 15:48:32 | TO "F" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-11-21 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-11-08 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2007-11-08 10:53:01 | TO "F" BOX |
|
|
|