Plan Review Details - Permit 07100789
Plan Review Stops For Permit 07100789
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-01-22 Cont ID  
Sent By shill Date 2008-01-22 Time 15:30 Rev Time 0.00
Received By shill Date 2008-01-22 Time 15:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2008-01-15 Cont ID  
Sent By shill Date 2008-01-15 Time 10:26 Rev Time 0.00
Received By shill Date 2008-01-15 Time 10:26 Sent To  
Notes
2008-01-15 10:50:46****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.THE MIAMIDADE NOA PROVIDED IS INCOMPLETE AND IS
 ILLEGIBLE.PRODUCT APPROVALS MAY BE AVAILABLE AT
 WWW.BUILDINGCODEONLINE.COM OR WWW.FLORIDABUILDING.ORG.
  
 2.THE ANCHOR PROPOSED IS NOT INCLUDED IN THE PRODUCT
 APPROVAL PROVIDED, WEATHERGUARD BUILDING PRODUCTS. SPEC
 SHEETS WERE PROVIDED BUT THEY ARE FOR A DIFFERENT
 PRODUCT, POMA CORPORATION.SEE PAGE 4 OF 5 OF THE
 PRODUCT APPROVAL.THE INSTALLATION SCHEDULE REFERS TO
 A WINDOW PRODUCT APPROVAL.IT IS NOT CLEAR WHAT
 PRODUCT YOU ARE INSTALLING; THEREFORE, CODE COMPLIANCE
 CANNOT BE DETERMINED.
  
 3.SEE SHEET 4.SOME ANCHORS ARE NOT PERMITTED FOR
 THE WEATHERGUARD PRODUCT INTO A CONCRETE BLOCK
 SUBSTRATE.ANCHOR SPACING SHOULD BE COMPLIANT WITH
 THIS SHEET, NOT WITH A SPEC SHEET FROM ANOTHER
 PRODUCT.
  
 4.WHEN REFERRING TO THE SHUTTER CONNECTION MOUNTING
 TYPE, COLUMN 4, PLASE REFER TO C1 THROUGH C5 TO
 CORRELATE WITH THE ANCHOR SCHEDULE.IT APPEARS THAT
 YOU ARE USING A C1 CONNECTION; THEREFORE, "C1" SHOULD
 BE STATED AS THIS COLUMN (RATHER THAN "WALL MOUNT").
  
 5.ANCHOR SIZE ON TH CHART IS NOTED AS 7/8" IN LENGTH.
 PLEASE NOTE THAT THIS IS AN EMBEDMENT REQUIREMENT;
 THEREFORE AN ANCHOR OF THIS LENGTH WILL NOT MEET THE
 EMBEDMENT REQUIREMENT IF THE BUILDING HAS STUCCO.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-12-28 Cont ID  
Sent By shill Date 2007-12-28 Time 15:25 Rev Time 0.00
Received By shill Date 2007-12-28 Time 15:25 Sent To  
Notes
2007-12-28 15:47:02****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.THE VALUE OF THE JOB IS TO INCLUDE LABOR (NOTE THAT
 FEES ARE CHARGED BASED ON VALUE, NOT COST).$4800 HAS
 BEEN ADDED AS A LABOR COST TO REMOVE AND INSTALL 16
 WINDOWS, INSTALL 16 SHUTTERS.
  
 2.PLEASE KEEP THE PRESTORM PREPARATION PLAN IN THE
 PERMIT PACKAGE (REQUIRED FOR PERMIT ISSUANCE).
  
 3.ALL CHANGES TO THE PLAN ARE TO BE CLOUDED AND
 MARKED WITH A REVISION NUMBER.FAILURE TO DO THIS
 CAUSES FURTHER DELAYS.SEE CORRECTION #4.
  
 4.SOME WINDOWS HAVE NOW BEEN MARKED "EXISTING
 EGRESS".IT IS NOT CLEAR WHY THIS LANGUAGE HAS BEEN
 ADDED; IT DOES NOT APPEAR ON THE PLAN DATED 12/6/07.
 THE WINDOWS DO NOT COMPLY WITH EMERGENCY EGRESS
 REQUIREMENTS APPLICABLE TO DAY CARE ROOMS.THE
 RESPONSE LETTER STATES THAT EMERGENCY EGRESS IS NOT
 REQUIRED.WHY HAS THE PLAN BEEN REVISED IN THIS WAY?
  
 ALSO, THIS CHANGE HAS NOT BEEN CLOUDED.HAS ANYTHING
 ELSE ON THE PLAN BEEN REVISED AND NOT SHOWN AS A
 REVISION?PLEASE REMOVE THIS LANGUAGE FROM THE PLAN OR
 REVISE THE PLAN TO COMPLY WITH EGRESS REQUIREMENTS.
  
 5.THE SCOPE OF WORK IS NOT CLEAR.THE APPLICATION
 STATES "REMOVAL & INSTALLATION OF 11 WINDOWS".WINDOWS
 ARE MARKED 1, 2, "EXISTING EGRESS" OR "EXISTING".THE
 SHUTTER INSTALLATION SCHEDULE INCLUDES INFORMATION FOR
 OPENING TYPES 1 AND 2.
  
 A.REVISE INSTALLATION SCHEDULE TO CORRELATE WITH EACH
 OPENING.YOU MAY USE ONE LINE FOR SEVERAL OPENINGS BUT
 THE INFORMATION MUST BE CORRECT.THE OPENING SIZE ON
 THE INSTALLATION SCHEDULE SHOULD BE THE OPENING SIZE,
 NOT THE WINDOW SIZE.
  
 B.AREN'T THE WINDOWS IN OPENINGS "EXISTING EGRESS"
 AND "EXISTING" BEING REPLACED?SHUTTERS OVER THESE
 WINDOWS WAS AN ISSUE IN PREVIOUS PLAN REVIEWS, BUT THE
 PLAN NOW DOESN'T SHOW THEM AS HAVING SHUTTERS
 INSTALLED.CLARIFY WHICH WINDOWS ARE BEING REPLACED,
 WHICH OPENINGS WILL HAVE SHUTTERS INSTALLED.
  
 C.APPLICATION STATES 11 WINDOWS;PLAN SHOWS 16
 WINDOWS, 7 OPENINGS.THE PLAN SHOWS A LOT OF
 INFORMATION WHICH IS NOT REQUIRED, YET DOES NOT INCLUDE
 THE INFORMATION REQUIRED FOR PERMIT ISSUANCE.THE
 PERMIT APPLICATION SHOULD BE CONSISTENT WITH THE SCOPE
 OF WORK AND THE PLAN.PLEASE REVISE.
  
 6.FOR THE WINDOWS, SHUTTERS, AND MULLIONS, THE
 FOLLOWING IS REQUIRED:
  
 A.FLORIDA STATE OR LOCAL PRODUCT APPROVAL,
 WWW.FLORIDABUILDING.ORG
  
 B.EVALUATION REPORT
  
 C.INSTALLATION INSTRUCTIONS
  
 PREVIOUSLY, A MIAMIDADE NOA WAS SUBMITTED.NOAS
 INCLUDE THE EVALUATION REPORT AND THE INSTALLATION
 INSTRUCTIONS IN ONE DOCUMENT.HOWEVER, FLORIDA STATE
 PRODUCT APPROVAL WAS NOT SUBMITTED.NOW, ONLY
 MIAMIDADE NOA FOR THE SINGLE HUNG WINDOW HAS BEEN
 PROVIDED ALONG WITH TWO COPIES OF THE FLORIDA STATE
 PRODUCT APPROVAL, A SPEC SHEET FOR THE SHUTTERS (NO
 PRODUCT APPROVAL), AND NOTHING FOR THE MULLIONS.
 PLEASE PROVIDE ALL REQUIRED PAPERWORK FOR EACH ITEM;
 TWO SETS.
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-12-11 Cont ID  
Sent By shill Date 2007-12-11 Time 10:32 Rev Time 0.00
Received By shill Date 2007-12-11 Time 10:32 Sent To  
Notes
2007-12-11 10:48:36****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 COMMENTS FROM PREVIOUS LIST, NOT ADDRESSED:
  
 1.PROVIDE A REASONABLE VALUATION FOR THIS JOB.
  
 2.COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR
 PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED.
  
 3.PRESTORM SHUTTER INSTALLATION PLAN PENDING.
  
 4-5.ADDRESSED.
  
 6.PLEASE ADDRESS THE USE OF THE WORDS "ARCHITECTURE"
 AND "INTERIOR DESIGN".AN INDIVIDUAL LICENSE IS
 REQUIRED, FS481.A SET HAS BEEN RETAINED AND MAY BE
 FILED WITH A COMPLAINT TO FBPE AND FLORIDA BOARD OF
 ARCHITECTS.DOCUMENTS PREPARED BY AN ARCHITECT OR
 INTERIOR DESIGNER AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED, DATED ORIGINALS FS481.
  
 IT APPEARS THAT, DESPITE WARNINGS FROM AND
 CONVERSATIONS WITH TWO DIFFERENT REVIEWERS ON TWO
 SEPARATE PROJECTS REGARDING THIS ISSUE, CONTRACTOR IS
 STILL USING "ARCHITECTURE" AND "INTERIOR DESIGN"
 WITHOUT A LICENSE.CONTRACTOR STILL SHOWS THIS NAME
 WITH THE DBPR WEBSITE, HAS USED THIS NAME ON
 LETTERHEAD, AND MAINTAINS AN ACTIVE CORPORATION.
 CONTRACTOR'S AGREEMENT WITH THE PLAN REVIEWERS WAS TO
 DISCONTINUE USE OF THE TERMINOLOGY OR THE MATTER WOULD
 BE FORWARDED TO FLORIDA BOARD OF ARCHITECTS.THIS
 COMMENT DOES NOT APPEAR TO HAVE BEEN ADDRESSED.
  
 7.ADDRESSED.
  
 8.SEE FBC1025.4.1 AND SHOW COMPLIANCE ON THE PLAN.
  
 THE ENGINEER HAS A STATEMENT ON THE PLAN, "2 EXIT DOORS
 IN EACH ROOM, NO EGRESS WINDOWS REQUIRED".THE "EXIT
 DOORS" DO NOT QUALIFY AS EXITS, SEE FBC1002
 DEFINITIONS.SEE FBC EB 505, YOU CANNOT REDUCE THE
 LEVEL OF SAFETY FOR MEANS OF EGRESS UNLESS IT COMPLIES
 WITH FBC CHAPTER 10.AS WINDOWS FOR EMERGENCY RESCUE
 IS REQUIRED, FBC1033.6 AND FBC1025.4.1, YOU ARE
 REDUCING THE LEVEL OF SAFETY BY INSTALLING HURRICANE
 SHUTTERS.
  
 9--10.ADDRESSED.
  
 11. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED IN
 ADDITION TO THE NOAS SUBMITTED, FAC9B72,
 WWW.FLORIDABUILDING.ORG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-11-05 Cont ID  
Sent By shill Date 2007-11-05 Time 09:43 Rev Time 0.00
Received By shill Date 2007-11-05 Time 09:43 Sent To  
Notes
2007-11-05 10:36:38****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.PROVIDE A REASONABLE VALUATION FOR THIS JOB.
  
 2.COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR
 PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED.
  
 3.USE OF REMOVABLE SHUTTERS ON COMMERCIAL BUILDINGS
 REQUIRES APPROVAL BY THE BUILDING OFFICIAL.AN
 INSTALLATION PLAN IS REQUIRED; SEE ATTACHED POLICY,
 ITEM 13.PLEASE DO NOT RESUBMIT THE PLAN SHOWING
 HURRICANE SHUTTERS UNLESS APPROVED BY THE BUILDING
 OFFICIAL.THE INSTALLATION PLAN MAY BE SUBMITTED VIA
 EMAIL OR AT THE FRONT COUNTER AT CONSTRUCTION SERVICES
 PRIOR TO RESUBMITTAL OF THIS PLAN.FAILURE TO ADDRESS
 THIS COMMENT WILL RESULT IN PERMIT DELAYS.
  
 4.CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE
 ARCHITECTURE THROUGH A COMPANY, FS481.219(2).
  
 5.THE CERTIFICATE OF AUTHORIZATION FOR THE
 ARCHITECTURE FIRM IS TO BE PRINTED ON EACH SHEET,
 FAC61G16-23.002, 003.
  
 6.PLEASE ADDRESS THE USE OF THE WORDS "ARCHITECTURE"
 AND "INTERIOR DESIGN".AN INDIVIDUAL LICENSE IS
 REQUIRED, FS481.A SET HAS BEEN RETAINED AND MAY BE
 FILED WITH A COMPLAINT TO FBPE AND FLORIDA BOARD OF
 ARCHITECTS.DOCUMENTS PREPARED BY AN ARCHITECT OR
 INTERIOR DESIGNER AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED, DATED ORIGINALS FS481.
  
 7.PROVIDE INFORMATION AS TO HOW THE ENGINEER IS
 CERTIFYING THE STRUCTURE, SEE THE NOTE ON THE PLAN.
  
 8.SEE FBC1025.4.1 AND SHOW COMPLIANCE ON THE PLAN.
  
 9.LEVEL 2 ALTERATION IS DECLARED.PLEASE CLARIFY, AS
 THE APPLICATION IS FOR WINDOW REPLACEMENT.SEE FBC EB
 CHAPTER 3.
  
 10. IT IS NOT CLEAR WHY THE FIRE ALARM AND LIFE SAFETY
 INFORMATION WAS PROVIDED ON THE PLAN FOR A WINDOW
 REPLACEMENT JOB.PLEASE CLARIFY SCOPE OF WORK.OTHER
 REVIEWS (FIRE, ELECTRIC) MAY BE REQUIRED WHEN
 RESUBMITTING.
  
 11. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED IN
 ADDITION TO THE NOAS SUBMITTED, FAC9B72,
 WWW.FLORIDABUILDING.ORG.
  
 12. PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER OF
 RECORD (SHOP DRAWING REVIEW STAMP OR LETTER),
 FBC*106.3.3.
  
 13. THE TERMINOLOGY ON THE PLAN IS NOT CORRECT;
 CATEGORY IS NOT VB, SEE FBC CHAPTER 5 AND FBC CHAPTER
 16."ENCLOSED" IS RELATED TO WIND, FBC CHAPTER 16, NOT
 OCCUPANCY CLASSIFICATION FBC CHAPTER 3.
  
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-10-26 Cont ID  
Sent By swurafti Date 2007-10-26 Time 15:38 Rev Time 0.00
Received By swurafti Date 2007-10-26 Time 15:38 Sent To  
Notes
2007-10-26 15:47:26HISTORIC APPROVED BY GJUDGE

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-01-18 Cont ID  
Sent By adarroug Date 2008-01-18 Time 14:15 Rev Time 0.00
Received By adarroug Date 2008-01-18 Time 14:15 Sent To  
Notes
2008-01-18 14:15:17TO "COMM" BD#33

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-01-08 Cont ID  
Sent By adarroug Date 2008-01-08 Time 16:22 Rev Time 0.00
Received By adarroug Date 2008-01-08 Time 16:22 Sent To B
Notes
2008-01-08 16:22:25TO "SHILL' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-12-19 Cont ID  
Sent By adarroug Date 2007-12-19 Time 13:47 Rev Time 0.00
Received By adarroug Date 2007-12-19 Time 13:47 Sent To B
Notes
2007-12-19 13:48:47TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-12-07 Cont ID  
Sent By adarroug Date 2007-12-07 Time 14:28 Rev Time 0.00
Received By adarroug Date 2007-12-07 Time 14:28 Sent To B
Notes
2007-12-07 14:29:12TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-12-11 Cont ID  
Sent By shill Date 2007-11-05 Time 13:48 Rev Time 0.00
Received By shill Date 2007-10-26 Time 16:04 Sent To  
Notes
2007-10-26 16:04:56TO "MISC" BOX#1