Plan Review Details - Permit 07100743
Plan Review Stops For Permit 07100743
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2008-01-07 Cont ID  
Sent By lursu Date 2008-01-07 Time 14:31 Rev Time 0.00
Received By lursu Date 2008-01-07 Time 14:31 Sent To  
Notes
2008-01-07 14:35:09PAGE C-1 INCLUDED WITH THE PLANS REPRESENT THE INTERIOR
 ROAD AND THE LOCATION JOB IS INDEED EAST OF N JOG RD AT
 5920 N JOG RD.
  
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2007-12-31 Cont ID  
Sent By lursu Date 2007-12-31 Time 11:24 Rev Time 0.00
Received By lursu Date 2007-12-31 Time 14:31 Sent To  
Notes
2007-12-31 11:27:51BASED ON THE LOCATION MAP THE PERMIT SHOULD READ 6501 N
 JOG RD ,PLEASE MAKE CORRECTIONS ON THE SITE PLANS AND
 APPLICATION .
  
 QUESTIONS/COMMENTS:
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-01-07 Cont ID  
Sent By shill Date 2007-12-28 Time 18:58 Rev Time 0.00
Received By shill Date 2007-12-28 Time 17:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-11-09 Cont ID  
Sent By shill Date 2007-11-09 Time 16:29 Rev Time 0.00
Received By shill Date 2007-11-09 Time 16:28 Sent To  
Notes
2007-11-09 16:30:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS FS471.025.SOME SHEETS WERE NOT SIGNED OR
 SEALED, OTHERS NOT SEALED BUT SIGNED AND DATED.PLEASE
 SUBMIT ALL SHEETS SIGNED, SEALED AND DATED.
  
 2.S1, INCLUDE 2007 AMENDMENTS IN GOVERNING CODE
 EFFECTIVE 7/1/2007.
  
 3.PROVIDE TWO ORIGINAL SIGNED, SEALED, DATED SETS OF
 THE SOILS REPORTS REFERRED TO ON S2.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-12-22 Cont ID  
Sent By dpalmer Date 2007-12-22 Time 13:45 Rev Time 0.00
Received By dpalmer Date 2007-12-22 Time 13:45 Sent To  
Notes
2007-12-22 13:50:31ALL CONNECTIONS ON 5KV SHALL BE 90C RATED PER 110.14,
 VEROFIED BY THE ENGINEER ON E-MAIL DATED 12/20/07

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-11-26 Cont ID  
Sent By dpalmer Date 2007-11-26 Time 16:38 Rev Time 0.00
Received By dpalmer Date 2007-11-26 Time 16:24 Sent To  
Notes
2007-11-26 16:38:21** DENIED**
  
  
  
 1) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS
 WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES
 PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE.
 PLEASE SEE THAT THIS SHALL INCLUDE 2006/2007 REVISIONS
 TO THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70.
 PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY
 AFFECT DESIGNS FOR ALL TRADES.
 PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS
 REVIEWER AT A MINIMUM.
 2004 FBC W/ 2006/07 REVISIONS
 2005 NFPA-70
  
 2) NOTE:PLEASE SEE ADDRESS OF LOCATION AS APPLIED IS
 7501 JOG RD., YET OUR SYSTEM AS APPLIED ADDRESS IS
 6501. THE PLANS AND DOCUMENTS HAVE BEEN ROUTED TO
 ADDRESSING FOR REVIEW AND COORDINATION. PLEASE KNOW
 ONCE THE ADDRESS HAS BEEN DETERMINED; PLEASE ADJUST
 TITLE BLOCKS OF PLANS FOR LOCATION.
 FAC 61G15-23.002, FBC ADMIN SECTION 106.1.2, 110.2
 PLEASE BE SURE TO ADJUST ALL PLANS, AND SUPPORTING
 DOCUMENTATION.
  
 3) NOTE: PLEASE SEE THE CONDUCTORS TO NEW 1K
 TRANSFORMER ARE ONLY RATED FOR 175AMPS YET OVER CURRENT
 PROTECTION IS 200AMPS.
 PLEASE SEE 240.4, 310.16, AND 240.6 AND ADJUST. (3/0
 MIN. REQUIRED).
 110.14.
  
 4) NOTE: PLEASE SEE PLANS ON E-2 MENTIONS 4/0 FOR
 GROUND LOOP HOWEVER SOME SECTIONS ON E-4 ARE 2/0 AND
 4/0?
 PLEASE CLARIFY.
 250.50, 250.64
  
 PLEASE KNOW, STRUCTURAL REVIEW WILL BE DONE BY BUILDING
 REVIEWER.
 PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-01-08 Cont ID  
Sent By mwennerg Date 2008-01-08 Time 10:52 Rev Time 0.00
Received By mwennerg Date 2008-01-08 Time 10:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-11-27 Cont ID  
Sent By mawillia Date 2007-11-27 Time 12:53 Rev Time 0.00
Received By mawillia Date 2007-11-27 Time 12:39 Sent To  
Notes
2007-11-27 12:45:53*****UNSAT*****
  
 1.PLEASE EXPLAIN/CLARIFY THE FLARE CONTROL
 PANEL/FLARE SKID AND HOW IT WOULD IMPACT FIRE AND LIFE
 SAFETY CONCERNS.
  
 2.THE PROJECT SITE ADDRESS SHALL BE IN THE TITLE
 BLOCK OF EACH SUBMITTED PLAN SHEET.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2008-01-16 Cont ID  
Sent By kstevens Date 2008-01-16 Time 11:04 Rev Time 0.00
Received By kstevens Date 2008-01-16 Time 11:04 Sent To  
Notes
2008-01-16 11:06:19MAIN GAS LINE FROM LANDFILL TO COMPRESSOR. ALL
 CONNECTIONS FROM COMPRESSOR, DRYER, CHILLER TO BE
 PREFABED FLANGED SECTIONS.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-12-07 Cont ID  
Sent By kstevens Date 2007-12-07 Time 18:47 Rev Time 0.00
Received By kstevens Date 2007-12-07 Time 18:47 Sent To  
Notes
2007-12-07 19:01:43DENIED
 REFERENCE: FBC-2004 FUEL GAS
 FBC-2004 CHAPTER 1
  
 1. MORE INFORMATION IS REQUIRED. PLEASE INDICATE WHAT
 OUTLET PRESSURE IS THE PIPING DESIGNED FOR DOWNSTREAM
 OF THE COMPRESSOR.--PLEASE INDICATE THE METHOD OF
 PIPING THE DIFFERENT SKID EQUIPMENT, SUCH AS THE
 COMPRESSOR, DRYER, FLARE ETC. IF THE METHOD IS WELD
 PIPE, THEN THE WELDING PROCEDURE AND WELDING
 CERTIFICATIONS WILL BE REQUIRED PRIOR TO ISSUING THE
 PERMIT. A PICTURE IDENTIFICATION WILL BE REQUIRED ALONG
 WITH THE CERTIFICATIONS. SECTION 106.1.2.
  
 2. PLEASE PROVIDE MANUF. SPECIFICATION SHEETS FOR THE
 COMPRESSOR, DRYER, ETC. SECTION 106.1.2.
  
 3. THE ADDRESS ON THE APPLICATION DOES NOT REFLECT THE
 ADDRESS IN OUR SYSTEM. ONCE THE CORRECT ADDRESS IS
 DETERMINED, ALL PLAN TITLE BLOCKS AND SHALL SHOW THE
 CORRECT ADDRESS PER SECTION 106.1.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-12-20 Cont ID  
Sent By mmiller Date 2007-12-20 Time 18:00 Rev Time 0.00
Received By mmiller Date 2007-12-20 Time 18:00 Sent To  
Notes
2007-12-20 18:00:34SENT TO COMMERCIAL BOARD # 59 MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-12-10 Cont ID  
Sent By kstevens Date 2007-12-10 Time 07:10 Rev Time 0.00
Received By kstevens Date 2007-10-25 Time 14:26 Sent To  
Notes
2007-11-13 09:28:01TO "COMM" BD#16
2007-10-25 14:27:05WAITING FOR "COMM" BD

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-01-16 Cont ID  
Sent By kstevens Date 2008-01-16 Time 11:03 Rev Time 0.00
Received By kstevens Date 2008-01-16 Time 11:03 Sent To  
Notes
2008-01-16 11:04:06CONDENSATE LINE FROM DRYER TO DRAIN.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-12-27 Cont ID  
Sent By eschneid Date 2007-12-27 Time 10:47 Rev Time 0.00
Received By eschneid Date 2007-12-27 Time 10:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-10-30 Cont ID  
Sent By eschneid Date 2007-10-30 Time 19:16 Rev Time 0.00
Received By eschneid Date 2007-10-30 Time 19:16 Sent To  
Notes
2007-10-30 19:18:51FAILED
  
 1) THE PERIMETER OF THE GAS COMPRESSION SKID SYSTEM
 SHALL BE SCREENED BY HEDGE MATERIAL.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.