| 2007-11-02 13:05:44 | DENIED |
| | REFERENCE: |
| | ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. |
| | ** FBC-2004 CHAPTER 1, THE CITY OF |
| | WEST PALM BEACH AMENDMENTS. |
| | ** FLORIDA ADMINISTRATIVE CODE (FAC). |
| | ** FLORIDA STATUTES (FS). |
| | |
| | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: |
| | |
| | 1. MORE INFORMATION IS REQUIRED DUE TO THE FACT THAT A |
| | PLUMBING PERMIT HAS BEEN APPLIED FOR PROPOSED PLUMBING |
| | TO A NEW LAUNDRY BOX. PLEASE PROVIDE THE FOLLOWING |
| | INFORMATION AS IT PERTAINS TO YOUR JOB. |
| | |
| | *** IF THE NEW PROPOSED PLUMBING FLOOR PLAN LAYOUT IS |
| | DIFFERENT FROM THE EXISTING FLOOR PLAN LAYOUT PLEASE |
| | SUBMIT THE FOLLOWING INFORMATION ON SEPERATE DRAWINGS. |
| | |
| | |
| | A) EXISTING FLOOR PLAN LAYOUT. |
| | |
| | B) NEW PROPOSED FLOOR PLAN LAYOUT AND PLEASE FOLLOW |
| | WHAT IS REQUIRED IN COMMENT #2. |
| | |
| | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 |
| | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A |
| | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING |
| | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT |
| | LOCATIONS OF THE PROPOSED PLUMBING TO THE NEW LAUNDRY |
| | BOX IS REQUIRED. |
| | |
| | 3. THE FOLLOWING INFORMATION IS REQUIRED FOR THE |
| | PROPOSED PLUMBING TO THE NEW LAUNDRY BOX |
| | |
| | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND |
| | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES |
| | WASHER SHALL BE A MINIMUM OF 2 INCHES |
| | (51MM) IN DIAMETER. THE AUTOMATIC |
| | CLOTHES WASHER FIXTURE DRAIN SHALL |
| | CONNECT TO A BRANCH DRAIN OR DRAINAGE |
| | STACK A MINIMUM OF 3 INCHES (76MM) IN |
| | DIAMETER. |
| | |
| | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY |
| | TRAPPED. STANDPIPES SHALL |
| | EXTEND A MINIMUM OF 18 INCHES (457MM) |
| | AND A MAXIMUM OF 42 INCHES (1066MM) |
| | ABOVE THE TRAP WEIR. ACCESS SHALL BE |
| | PROVIDED TO ALL STANDPIPES AND DRAINS |
| | FOR RODDING. |
| | |
| | (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL |
| | BE THE SAME NOMINAL SIZE AS THE PIPE |
| | THEY SERVE UP TO 4 INCHES (102MM) |
| | **NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE THREE |
| | INCH (3"). |
| | |
| | (D) 708.9 ACCESS. ACCESS SHALL BE |
| | PROVIDED TO ALL CLEANOUTS. |
| | **NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE |
| | LOCATED AT FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.). |
| | |
| | 4. FBC-2004 CHAPTER 1,SECTION 106.3.4.3: |
| | THE PERSON RESPONSIBLE FOR THE DESIGN OF |
| | THE DRAWING SHALL CLEARLY PRINT AND SIGN |
| | NAME, AND ALSO DATE DRAWING. PLEASE DO |
| | THIS PRIOR TO RESUBMITTING. |
| | |
| | **NOTE: PLEASE REFERENCE THE EXAMPLE SANITARY ISOMETRIC |
| | RISER DIAGRAM ATTACHED TO THE PLUMBING COMMENTS THAT |
| | REFLECTS THE FLOOR PLAN AND IS CODE COMPLIANT: |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY: MIKE PERSON |
| | PLUMBING PLANS EXAMINER |
| | (561) 805-6730 |
| | FAX (561) 805-6731 |
| | E-MAIL: [email protected] |