Plan Review Details - Permit 07100355
| Plan Review Stops For Permit 07100355 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-31 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-31 |
Time |
15:18 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-24 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-24 |
Time |
13:55 |
Sent To |
I |
|
| Notes |
| 2007-10-24 14:08:04 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} HAND DRAWN PLANS IN PENCIL ARE NOT ACCEPTABLE FOR | | | RECORD RETENTION OR CLARITY IN THE FIELD. 106.1.3 FBC | | | AS AMENDED. | | | | | | 2} TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR | | | REVIEW PER 106.1 FBC AS AMENDED. | | | | | | 3} THE SCOPE OF WORK ON THEAPPLICATION INDICATES | | | REPLACING THE DISCONNECT, BUT A COMPLETE REWIRE WAS | | | SUBMITTED. IF THE REWIRE IS TO BE PART OF THIS PERMIT, | | | CHANGE THE SCOPE ON THE APPLICATION TO REFLECT SAME AND | | | INCREASE THE PROJECT VALUE TO ENCOMPASS ALL WORK. | | | | | | 4} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT | | | CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE | | | EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS | | | EQUAL TO OR GREATER THAN THE AVAILABLE FAULT. | | | | | | 5 } PROVIDE CONDUIT AND CONDUCTOR SIZE AND TYPE TO THE | | | EQUIPMENT TO BE INSTALLED. SEE METER TO DISCONNECT ON | | | RISER. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-31 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-31 |
Time |
12:33 |
Sent To |
E |
|
| Notes |
| 2007-10-31 12:34:13 | TO "BTROBAUGH" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-24 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-12 |
Time |
09:44 |
Sent To |
PC |
|
| Notes |
| 2007-10-12 09:44:49 | TO "E" BOX |
|
|
|