Plan Review Details - Permit 07100326
Plan Review Stops For Permit 07100326
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-06-26 Cont ID  
Sent By mjacobs Date 2008-06-26 Time 12:14 Rev Time 0.00
Received By mjacobs Date 2008-06-26 Time 11:08 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-03-17 Cont ID  
Sent By mjacobs Date 2008-03-17 Time 13:22 Rev Time 0.00
Received By mjacobs Date 2008-03-17 Time 11:50 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-11-10 Cont ID  
Sent By mjacobs Date 2007-11-10 Time 07:36 Rev Time 0.00
Received By mjacobs Date 2007-11-10 Time 06:27 Sent To  
Notes
2007-11-10 07:36:54BUILDING PLAN REVIEW
 PERMIT: 07100326
 ADD: 1801 S. FLAGLER DR. #302
 CONT: RCX TILT UP CONSTRUCTION INC.
 TEL: (561)386-6032
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
 **NO RESPONSE NOT ADDRESSED**
 1)WPB AMENDMENTS 106.1.2PROVIDE A FRAMING WALL
 DETAIL FOR THE NEW WALL. THE BUILDING OFFICIAL MAY
 REQUIRE DETAILS AND OTHER DATA NECESSARRY TO DESCRIBE
 THE CONSTRUCTION OF THE PROJECT. INDICATE THE STUD
 SPACING AND ALL MATERIALS FOR THE NEW WALL.IF ANY
 PORTION OF THE TENANT SEPERATION WALL IS DEMOED,
 CLEARLY INDICATE HOW THE RATING OF THE NEW WALL WILL
 MEET THE TENANT SPEREATION REQUIREMENTS. PER FBC 708.
 *******************************************************
  
 **A UL ASSEMBLY OF THE NEW FRAME WALLS SHALL BE
 INDICATED ON THE PLANS.** WHAT TYPE OF MATERIALS WILL
 BE USE TO CONSTRUCT THEOPENING FOR THE NEW DOOR.
 SUBMIT AN EXISTING AND PROPOSED LAYOUT OF THE AREA OF
 PRPOPOSED WORK. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THE CODE. FBC.
 106.1.1
  
 **A CROSS SECTION DETAIL DRAWING OF THE NEW SHOWER
 FLOOR IS REQUIRED TO SHOW THE MATERIALS AND THE
 CONSTRUCTION OF THE FLOOR. IS THE 3/4 INCH FIRE RATED
 PLYWOOD USED TO CONSTRUT THE SHOWER FLOOR?**
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-23 Cont ID  
Sent By mjacobs Date 2007-10-23 Time 10:03 Rev Time 0.00
Received By mjacobs Date 2007-10-23 Time 07:50 Sent To  
Notes
2007-10-23 10:03:34BUILDING PLAN REVIEW
 PERMIT: 07100326
 ADD: 1801 S. FLAGLER DR. #302
 CONT: RCX TILT UP CONSTRUCTION INC.
 TEL: (561)386-6032
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)WPB AMENDMENTS 106.1.2PROVIDE A FRAMING WALL
 DETAIL FOR THE NEW WALL. THE BUILDING OFFICIAL MAY
 REQUIRE DETAILS AND OTHER DATA NECESSARRY TO DESCRIBE
 THE CONSTRUCTION OF THE PROJECT. INDICATE THE STUD
 SPACING AND ALL MATERIALS FOR THE NEW WALL.IF ANY
 PORTION OF THE TENANT SEPERATION WALL IS DEMOED,
 CLEARLY INDICATE HOW THE RATING OF THE NEW WALL WILL
 MEET THE TENANT SPEREATION REQUIREMENTS. PER FBC 708.
  
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-06-23 Cont ID  
Sent By btrobaug Date 2008-06-23 Time 14:15 Rev Time 0.00
Received By btrobaug Date 2008-06-23 Time 14:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-03-14 Cont ID  
Sent By dpalmer Date 2008-03-14 Time 10:17 Rev Time 0.00
Received By dpalmer Date 2008-03-14 Time 10:17 Sent To  
Notes
2008-03-14 10:31:24 
 *** REDLINED PLANS ONCE AGIN.
  
 INCORRECT NFPA-70 REFERENCED, SHOULD BE 2005 NOT 2004
 SA PER R313

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-11-07 Cont ID  
Sent By dpalmer Date 2007-11-07 Time 15:37 Rev Time 0.00
Received By dpalmer Date 2007-11-07 Time 15:37 Sent To  
Notes
2007-11-07 15:39:05NEW ELECTRICAL SHEETS.
  
 INCORRECT NFPA-70 REFERENCED, SHOULD BE 2005 NFPA-70

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-10-16 Cont ID  
Sent By dpalmer Date 2007-10-16 Time 12:02 Rev Time 0.00
Received By dpalmer Date 2007-10-16 Time 11:59 Sent To  
Notes
2007-10-16 12:03:08** REDLINED PLANS.
  
  
 1) RECEPTACLE IN BATH NOT SHOWN AS GFI AS REQUIRED PER
 210.8A1
 2) VERIFY SA'S PER R313, NFPA-72. (MAY USE EXCEPTION
 FOR BATTERY IF 120V ARE NOT ALREADY PRESENT.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2008-06-26 Cont ID  
Sent By mawillia Date 2008-06-26 Time 11:54 Rev Time 0.00
Received By mawillia Date 2008-06-26 Time 11:51 Sent To  
Notes
2008-06-26 11:53:14*****REVISION APPROVED*****
  
  
 REVISED PLAN SHEET STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-03-14 Cont ID  
Sent By mwennerg Date 2008-03-14 Time 15:45 Rev Time 0.00
Received By mwennerg Date 2008-03-14 Time 15:45 Sent To  
Notes
2008-03-14 15:46:17NEW SHEET STAMPED

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-11-09 Cont ID  
Sent By mwennerg Date 2007-11-09 Time 15:50 Rev Time 0.00
Received By mwennerg Date 2007-11-09 Time 15:50 Sent To  
Notes
2007-11-09 15:51:00PLANS APPROVED ON 10/23/07. NEW SHEET STAMPED ON THIS
 DATE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-10-23 Cont ID  
Sent By mwennerg Date 2007-10-23 Time 13:17 Rev Time 0.00
Received By mwennerg Date 2007-10-23 Time 13:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-06-18 Cont ID  
Sent By adarroug Date 2008-06-18 Time 15:02 Rev Time 0.00
Received By adarroug Date 2008-06-18 Time 15:02 Sent To  
Notes
2008-06-18 15:03:02TO "BOB"#13

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-03-11 Cont ID  
Sent By adarroug Date 2008-03-11 Time 17:00 Rev Time 0.00
Received By adarroug Date 2008-03-11 Time 17:00 Sent To  
Notes
2008-03-11 17:02:15TO "BOB"#3

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-06 Cont ID  
Sent By adarroug Date 2007-11-06 Time 10:31 Rev Time 0.00
Received By adarroug Date 2007-11-06 Time 10:31 Sent To  
Notes
2007-11-07 11:08:34TO "BOB"#15
2007-11-06 10:32:03WAITING FOR "BOB"--NEW SHEETS FOR ALL TRADES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-24 Cont ID  
Sent By jleech Date 2007-10-24 Time 14:48 Rev Time 0.00
Received By jleech Date 2007-10-11 Time 12:18 Sent To  
Notes
2007-10-16 11:05:50TO "BOB"#18
2007-10-11 12:19:03WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-11-09 Cont ID  
Sent By tgordon Date 2007-11-09 Time 09:11 Rev Time 0.15
Received By tgordon Date 2007-11-09 Time 09:11 Sent To  
Notes
2007-11-09 09:12:13BATHROOM FAN EXISTING.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-10-18 Cont ID  
Sent By tgordon Date 2007-10-18 Time 08:14 Rev Time 0.25
Received By tgordon Date 2007-10-18 Time 08:14 Sent To  
Notes
2007-10-18 08:32:13PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) THE BATHROOM WILL NEED AN EXHAUST FAN, SEE 2004
 FBC/EXISTING 609.1 AND FBC/R R303.3 EXCEPT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-06-26 Cont ID  
Sent By jleech Date 2008-06-26 Time 11:45 Rev Time 0.00
Received By jleech Date 2008-06-26 Time 11:45 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-03-20 Cont ID  
Sent By jleech Date 2008-03-14 Time 07:58 Rev Time 0.00
Received By jleech Date 2008-03-14 Time 07:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-11-17 Cont ID  
Sent By jleech Date 2007-11-17 Time 12:47 Rev Time 0.00
Received By jleech Date 2007-11-17 Time 12:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-10-24 Cont ID  
Sent By jleech Date 2007-10-24 Time 14:48 Rev Time 0.00
Received By jleech Date 2007-10-24 Time 14:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2007-10-17 Cont ID  
Sent By choops Date 2007-10-17 Time 15:41 Rev Time 0.00
Received By choops Date 2007-10-17 Time 15:41 Sent To  
Notes
2007-10-17 15:41:44*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.