Plan Review Details - Permit 07100224
| Plan Review Stops For Permit 07100224 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-16 |
Time |
14:37 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2007-11-16 |
Time |
14:37 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-11 |
Time |
12:23 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-10-11 |
Time |
12:09 |
Sent To |
PC |
|
| Notes |
| 2007-10-11 12:35:21 | BUILDING PLAN REVIEW | | | PERMIT: 07100224 | | | ADD: 1301 SUMMIT BLVD | | | CONT: JUPITER ROOFING | | | TEL: (561)248-8612 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)THE MASTER PERMIT INDICATES THE FINISHED ROOFING | | | WILL BE CORRAGATED METAL, NO PRODUCT APPROVALS WERE | | | SUBMITTED FOR THE CORRAGATED ROOFING SYSTEM. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 2) THETAMKO PRODUCT APPROVALS SUBMITTED IN EACH SET | | | OF DOCUMENTS HAVE DIFFERENT SYSTEMS CIRCLED, ONE HAS | | | SHEET 16 CIRCLED WHILE THE OTHER HAS SHEET 18 CIRCLED, | | | PLEASE CORRECT AND SUBMITT ONLY ONE SUB-SYSTEM. NOTE | | | SHEET 18 THE MAXIMUM DESIGM PRESSURE REFERENCES THE | | | TILE MANUFACTURER'S NOA FOR THE MAXIMUM DESIGN | | | PRESSURE. | | | | | | 3) THE OTHER SYSTEM THAT IS CIRCLED ON SHEET 16 IN THE | | | SECOND PACKET HAS TWO OPTIONS BOTH OPTIONS WILL END UP | | | WITH LOW PRESSURES IN ZONES 2 & 3 PROVIDE THE | | | RAS 117 CALCULATIONSFOR ENHANCED FASTENING. | | | | | | 4)WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-11 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-10-09 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2007-10-09 16:11:12 | TO "JWITMER" DESK |
|
|
|